Titan 5V0002UL0AL00B Dimensions Guide

Type
Dimensions Guide

This manual is also suitable for

Titan 5V0002UL0AL00B is a device designed to provide protection against electrical hazards and power surges. Its primary function is to monitor incoming electrical current and automatically disconnect the power supply in the event of an overvoltage or short circuit, safeguarding connected equipment from damage. Additionally, it offers the following capabilities:

  • Surge Protection: The device absorbs and diverts excess voltage caused by power surges, preventing it from reaching and harming sensitive electronic devices.

  • Overvoltage Protection: It monitors electrical current and triggers a shutdown if the voltage exceeds a safe level, protecting connected equipment from damage due to abnormally high voltage.

Titan 5V0002UL0AL00B is a device designed to provide protection against electrical hazards and power surges. Its primary function is to monitor incoming electrical current and automatically disconnect the power supply in the event of an overvoltage or short circuit, safeguarding connected equipment from damage. Additionally, it offers the following capabilities:

  • Surge Protection: The device absorbs and diverts excess voltage caused by power surges, preventing it from reaching and harming sensitive electronic devices.

  • Overvoltage Protection: It monitors electrical current and triggers a shutdown if the voltage exceeds a safe level, protecting connected equipment from damage due to abnormally high voltage.

PRODUCT MEASURING GUIDE
This guide contains procedures and instructions for proper
measurement before installing a security screen door. If a circumstance
comes up that is not covered in this guide, please contact us for help at:
Unique Home Designs
973 N. Colorado Street, Gilbert AZ. 85233
or
VIEW INSTALLATION VIDEOS
AND LATEST INFORMATION AT
Getting Started
1
Inspect Your Entryway for Obstructions: Check for any
obstructions above and around your entryway that may
prevent the outward swing of your new security door, and/
or its installation, such as: light xtures, door bell, low
overhang, door handle of your existing door, and trees,
bushes, or hanging plants.
The security door will require a minimum mounting surface of 1" on the trim above and on both sides of the entry door
(1" depth also required for recessed mount). Mounting screws must be secured to a stud in the wall. Review Figures
1-5 to determine which mounting method you can and wish to use and the rough opening measurement.
Determine Mounting Method and Rough Opening Measuring Points
2
MK1359 01232020
Advanced Screen Systems
Advanced Screen Systems
Advanced Screen Systems
Advanced Screen Systems
Advanced Screen Systems
Advanced Screen Systems
Meshtec Co. logo from them Recreated for UHD use
Advanced Screen Systems
Advanced Screen Systems
Advanced Screen Systems
Advanced Screen Systems
Advanced Screen Systems
Typical Recessed Mount
The security door will be mounted on a corner of the
door jamb trim.
Recessed Mount
Surface Mount
Security Door
Security Door
Security Door
Security Door
Entry Door
SSA
MESHTEC
1-1/2”
2-5/8”
Entry Door
Recessed Mount
Surface Mount
Security Door
Entry Door
1-1/2”
2-5/8”
Entry Door
Security Door
Security Door
Security Door
1" mounting
surface
1" mounting
surface
Figure 1 Brick Molding - Recessed Mount
Brick
moulding trim
StudStud
Entry Door Jamb
Entry Door
Minimum 2-5/8"
1" minimum mounting surface
Entry Door
StudStud
Entry Door Jamb
Flat Trim
Minimum 2-5/8"
Figure 2 Flat Trim - Recessed Mount
1" minimum mounting surface
Figure 3 Sloped Trim - Recessed Mount
StudStud
Entry Door
Entry Door Jamb
Sloped Trim
1" minimum
mounting
surface
1" minimum
mounting
surface
Minimum 2-5/8"
Additional sloped trim may be added in the reverse direction to
create at surface OR Sloped trim may be removed or replaced
with at trim to properly mount your new security door
Figure 4 Stucco - Recessed Mount
Entry Door
StudStud
Entry Door Jamb
Stucco
Pop-out
Minimum 2-5/8"
1" minimum mounting surface
rough opening width
rough opening width
rough opening width
rough opening width
Figure 1 Brick Molding - Surface Mount
Brick
moulding trim
StudStud
Entry Door Jamb
Entry Door
1" minimum mounting surface
Minimum 2-3/8"
Entry Door
StudStud
Entry Door Jamb
Flat Trim
Minimum 2-3/8"
Figure 2 Flat Trim - Surface Mount
1" minimum mounting surface
Figure 3 Sloped Trim - Surface Mount
Additional sloped trim may be added in the reverse direction to
create at surface OR Sloped trim may be removed or replaced
with at trim to properly mount your new security door
StudStud
Entry Door
Entry Door Jamb
Sloped Trim
1" minimum
mounting
surface
1" minimum
mounting
surface
Minimum 2-3/8"
Entry Door
StudStud
Entry Door Jamb
Stucco
Pop-out
Minimum 2-3/8"
1" minimum mounting surface
Figure 4 Stucco 1 - Surface Mount
Entry Door
StudStud
Entry Door Jamb
Stucco
Pop-out
Minimum 2-3/8"
mounted to front surface of stucco pop-outs
This application will require 6" screws (sold separately)
1" minimum mounting surface
Figure 5 Stucco 2 - Surface Mount
rough opening width
rough opening width
rough opening width
rough opening width
rough opening width
Recessed Mount
Surface Mount
Security Door
Security Door
Security Door
Security Door
Entry Door
SSA
MESHTEC
1-1/2”
2-5/8”
Entry Door
Recessed Mount
Surface Mount
Security Door
Entry Door
1-1/2”
2-5/8”
Entry Door
Security Door
Security Door
Security Door
Typical Surface Mount
The security door will be mounted on front surface
of the existing trim.
1" mounting
surface
1" mounting
surface
2-3/8"
ULTIMATE SCREEN DOOR
Advanced Screen Systems
Advanced Screen Systems
Advanced
Screen Systems
Advanced
Screen Systems
Advanced
Screen Systems
Advanced
Screen Systems
Measure for Rough Opening Height
3
Measuring Width
5
Measure for Rough Opening Width
Measure for the rough opening you
identified in Step 2 (Figures 1-5). Measure
the top, middle and the bottom of the
door opening. The smallest of the three
measurements will be your rough opening
width. Enter that measurement on the
measurement worksheet and follow the
instructions to determine if a standard size
door will fit.
W1
W2
W3
W1
W2
W3
Measure for Rough Opening Height
Measure from the bottom edge of the
mounting surface to the existing threshold of
your entry door and enter on the measurement
worksheet on the following page.
Check for Hardware Interference
4
Recessed Mount
Measure the depth from the corner of your mounting
surface to your existing entry door hardware. If this
measurement is 2-5/8" or greater there is no potential
for hardware interference. If the measurement is less
than 2-5/8", measure from the edge of the mounting
surface on top of the door to the top and bottom
edge of the part of your existing hardware that
intrudes into the 2-5/8" clearance. If either of these
two measurements falls between 40-1/4" and 44-
1/4", the security door and existing door hardware
will interfere with each other. You can either build
your mounting surface out to create the clearance
required or mount your security door with an
opposite swing to your main entry door.
Hinge-side
jamb
Entry Door
Premium Security Door w/ Meshtec Screen
Lock-side
jamb
Minimum 2-5/8"
Surface Mount
Measure the depth from the corner of your mounting
surface to your existing entry door hardware. If this
measurement is 2-3/8" or greater there is no potential
for hardware interference. If the measurement is less
than 2-3/8", measure from the edge of the mounting
surface on top of the door to the top and bottom
edge of the part of your existing hardware that
intrudes into the 2-3/8" clearance. If either of these
two measurements falls between 39-1/4" and 43-
1/4", the security door and existing door hardware
will interfere with each other. You can either build
your mounting surface out to create the clearance
required or mount your security door with an
opposite swing to your main entry door.
Hinge-side
jamb
Entry Door
Premium Security Door w/ Meshtec Screen
Lock-side
jamb
Minimum 2-3/8"
Door Size
* Rough Opening
Width Fit Range
Rough Opening Width
Overall
Width
* Rough Opening
Height Fit Range
Rough Opening Height
Overall
Height
32" x 80"
31-3/4" - 32-3/8"
34"
80" - 80-7/8"
82"
36" x 80"
35-3/4" - 36-3/8"
38"
60" x 80"
63-3/4" - 64-3/8"
65-3/4"
72" x 80"
71-3/4" - 72-3/8"
73-3/4"
Instructions:
Determine which t range your measurements fall within and order that standard size door.
Standard size door
* Wider rough opening measurements within the t range may require shimming or ller wood.
Door Size
* Rough Opening
Width Fit Range
Rough Opening Width
Overall
Width
* Rough Opening
Height Fit Range
Rough Opening Height
Overall
Height
32" x 80"
31-7/8" - 32-3/8"
34-1/2"
79-3/4" - 81-3/4"
81.5/8"
36" x 80"
35-7/8" - 36-3/8"
38-1/2"
64" x 80"
64-5/8" - 65-5/8"
67-11/16"
72" x 80"
72-5/8" - 73-5/8"
75-11/16"
36" X 96"
35-7/8" - 36-3/8"
38-1/2"
95-3/4" - 97-3/4"
97.5/8"
SURFACE MOUNT
RECESSED MOUNT
Note: If a custom size is necessary, add 2-7/8" to width and 1-7/16" to height to get overall frame dimension.
Note: Custom size is NOT available for recessed mount doors
  • Page 1 1
  • Page 2 2
  • Page 3 3

Titan 5V0002UL0AL00B Dimensions Guide

Type
Dimensions Guide
This manual is also suitable for

Titan 5V0002UL0AL00B is a device designed to provide protection against electrical hazards and power surges. Its primary function is to monitor incoming electrical current and automatically disconnect the power supply in the event of an overvoltage or short circuit, safeguarding connected equipment from damage. Additionally, it offers the following capabilities:

  • Surge Protection: The device absorbs and diverts excess voltage caused by power surges, preventing it from reaching and harming sensitive electronic devices.

  • Overvoltage Protection: It monitors electrical current and triggers a shutdown if the voltage exceeds a safe level, protecting connected equipment from damage due to abnormally high voltage.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI