Daewoo DSA-245L Specification

Category
Split-system air conditioners
Type
Specification

This manual is also suitable for

Manual de servicio
Split Acondicionador de Aire
Modelo:
Aviso:
En este manual,algunas partes pueden cambiar sin previo aviso en la lista 
de partes si usted necesita la ultima informacion por favor dirigirse a 
PPL(Parts Price List)Centro de informacion de 
servicio(http.//svc.dwe.co.kr).
http;//svc.dwe.co.kr Dic 2005
DSA-095L
DSA-125L,125P
DSA-185L,185P
DSA-245L,245P
CONTENTS
1. Specifications..........................................................................................................2
2. Outline and Dimensions.........................................................................................6
3. Operation ..............................................................................................................14
4. Wiring Diagram.....................................................................................................25
5. Control Block Diagram.........................................................................................28
6. Electric Circuit Diagram........................................................................................31
7. Trouble Shooting ..................................................................................................33
8. PCB Driving Description.......................................................................................39
9. Key Components of Electronic Circuit.................................................................63
10. Disassembly Instructions .....................................................................................66
1) Indoor Unit........................................................................................................66
2) Outdoor Unit.....................................................................................................70
3) Exploded Diagram (Indoor Unit)......................................................................73
4) Exploded Diagram (Outdoor Unit)...................................................................81
5) Control Box Assembly......................................................................................89
Contents
2
MODEL DSA-095L
ITEM
Function Cooling
Class T1
Power AC 230V/ 60Hz
Capacity KJ/h 9,000
Btu/h 8,531
Dehumidification l/h 1.1
Running Current A 3.6
Power Input W 800
Type Rotary
Model QK125KB(LGE)
Capacitor 25µF / 400VAC
Indoor Unit Outdoor Unit
Type Cross flow fan Propeller fan
Capacitor 1.0µF 400VAC 2.0µF 400VAC
Motor Model Number YDK-8-4A(Xiang Ming) YDK-35-6A(Xiang Ming)
Sound Level (Hi) dB(A) 39 48
Fan Speed (Hi) RPM 1,350 880
Control Capillary
Charge Q'ty g 680
Type Flare
OD
(Liquid/Suction)
in(mm) 1/4 (6.35) 3/8 (9.52)
Dimensions (W x H x D) mm 750 x 245 x 179 654 x 549 x 256
Net Weight kg 7.0 34
Electrical
Data
Compressor
Fan
Motor
Refrigerant
(R22)
Connection
DSA-095L
1. SPECIFICATIONS
3
MODEL DSA-125L, 125P
ITEM
Function Cooling
Class T1
Power AC 230V/ 60Hz
Capacity KJ/h 12,500
Btu/h 11,848
Dehumidification l/h 1.35
Running Current A 4.7
Power Input W 1,010
Type Rotary
Model QK156KA(LGE)
Capacitor 35µF/ 370VAC
Division Indoor Unit Outdoor Unit
Type Cross flow fan Propeller fan
Capacitor 1.2µF 400VAC 3µF 400VAC
Motor Model Number RP-13B(Welling) YDK-50-6A(Xiang Ming)
Sound Level (Hi) dB(A) 42 52
Fan Speed (Hi) RPM 1,300 870
Control Capillary
Charge Q'ty g 1,000
Type Flare
OD
(Liquid/Suction)
in(mm) 1/4 (6.35) 3/8 (9.52)
Dimensions (W x H x D) mm 815 x 285 x 195 800 x 615 x 320
Net Weight kg 9.2 50
Electrical
Data
Compressor
Fan
Motor
Refrigerant
(R22)
Connection
DSA-125L, 125P
4
MODEL DSA-185L, 185P
ITEM
Function Cooling
Class T1
Power AC 230V/ 60Hz
Capacity KJ/h 17,500
Btu/h 16,588
Dehumidification l/h 2.0
Running Current A 7.2
Power Input W 1,620
Type Rotary
Model QJ250KA(LGE)
Capacitor 35µF/ 370VAC
Division Indoor Unit Outdoor Unit
Type Cross flow fan Propeller fan
Capacitor 1.2µF 400VAC 3µF 400VAC
Motor Model Number YDK-20-4A(Xiang Ming) YDK-50-6A(Xiang Ming)
Sound Level (Hi) dB(A) 48.1 56
Fan Speed (Hi) RPM 1,370 870
Control Capillary
Charge Q'ty g 1,070
Type Flare
OD
(Liquid/Suction)
in(mm) 1/4 (6.35) 1/2 (12.7)
Dimensions (W x H x D) mm 1035 x 322 x 205 800 x 615 x 320
Net Weight kg 11.7 50
Electrical
Data
Compressor
Fan
Motor
Refrigerant
(R-22)
Connection
DSA-185L, 185P
5
MODEL DSA-245L, 245P
ITEM
Function Cooling
Class T1
Power AC 230V/ 60Hz
Capacity KJ/h 23,500
Btu/h 22,275
Dehumidification l/h 2.7
Running Current A 10.0
Power Input W 2,220
Type Rotary
Model QP325KBB (LGE)
Capacitor 40µF/ 400VAC
Division Indoor Unit Outdoor Unit
Type Cross flow fan Propeller fan
Capacitor 1.2µF 400VAC 3µF 400VAC
Motor Model Number IC-9430DWKF7A(Sung shin) A2929GS010(DMI)
Sound Level (Hi) dB(A) 48.5 57
Fan Speed (Hi) RPM 1,300 950
Control Capillary
Charge Q'ty g 1,850
Type Flare
OD
(Liquid/Suction)
in(mm) 3/8 (9.52) 5/8 (15.9)
Dimensions (W x H x D) mm 1080 x 298 x 200 872 x 675 x 325
Net Weight kg 14.7 64
Electrical
Data
Compressor
Fan
Motor
Refrigerant
(R-22)
Connection
DSA-245L, 245P
6
750
Plate Mounting
REMOCON
Connecting Pipe
Grille Insert
179
245
REMOTE CONTROLLER
Frame Grille
Body
Plate Mounting
2. OUTLINE AND DIMENSIONS
1
INDOOR UNIT
DSA-095L
MODE
SLEEP
ON/OFF
TIMER
ENTER/
CANCEL
FAN SPEED
TURBO/MILD
FAN DIR.
REMOCON
7
Insert Grille
Frame Grille
Body
Connecting Pipe
Plate Mounting
815
195
285
DSA-125L, 125P
MODE
SLEEP
ON/OFF
TIMER
ENTER/
CANCEL
FAN SPEED
TURBO/MILD
FAN DIR.
REMOCON
8
DSA-185L, 185P
1035
205
322
453
¿‹ Æ˘˜ ˙`
”fi `⁄˘˙
`⁄„«…–‚fi‚ ˜
‰˙‡»– ‚Ø– ‚–
‰˙‡»– ‚ ˆ…
Connecting Pipe
Filter-L Filter-R
Grille Insert
Body
Plate
Mounting
453
1035
MODE
SLEEP
ON/OFF
TIMER
ENTER/
CANCEL
FAN SPEED
TURBO/MILD
FAN DIR.
REMOCON
9
Connecting Pipe
Body
Frame Grille
Grille Insert
Plate Mounting
430
710
1080
Filter-L Filter-R
REMOCON
DSA-245L, 245P
200
298
MODE
SLEEP
ON/OFF
TIMER
ENTER/
CANCEL
FAN SPEED
TURBO/MILD
FAN DIR.
REMOCON
10
INSTALLING THE INSTALLATION PLATE
Unit : mm
• DSA-245L, 245P
• DSA-185L, 185P
• DSA-125L, 125P
• DSA-095L
11
2
OUTDOOR UNIT
DSA-095L
Outlet
Foot Cushion
Cabinet Front Cabinet Side Panel Top Guide Support
SVC Cover
Servise Valve
Inlet
Outlet
Inlet
256
286
324
539
549
460
654
12
DSA-125L, 125P, 185L, 185P
Inlet
Outlet
Outlet
Foot Cushion
Cabinet Front Cabinet Side Panel Top Guide Support
SVC Cover
Servise Valve
580
800
320
360
400
589
615
Inlet
13
DSA-245L, 245P
Inlet
325
350
380
673
697
Outlet
Outlet
Foot Cushion
Cabinet Front Cabinet Side Panel Top Guide Support
SVC Cover
Servise Valve
Inlet
549
872
14
1
NAME AND FUNCTION OF PARTS
Indoor Unit
3. OPERATION
DSA-095L
MODE
SLEEP
ON/OFF
TIMER
ENTER/
CANCEL
FAN SPEED
TURBO/MILD
FAN DIR.
REMOCON
15
Indoor Unit
DSA-125L, 125P
Removes small dust and
generates (-) ions.
(DSA-125P)
Electrostatic Filter
Removes dust particles
from the air
(DSA-125L)
Electric Dust Collector
(Air clean Plasma)
Air Cleaning Filters
Removes dust and
prohibits germs.
Emergency/Remote
Switch
Slide to select the
desired position.
Indicators
Indicate the setting
Deodorizing Filter
Removes bad smells
from the air.
Fan Direction
(Up/Down)
Indoor Cover
Power Plug
Cold Air
Air In
ONOFFENTERCANCEL
TIMERRESET
FAN DIR.
FAN SPEED
MODE
SLEEP
ON/OFF
TEMP.
LCD Remote Controller
Connection Cover
Remove cover to access
the AC connection from
this unit to the outdoor unit.
Remote
Sensor
MODE
SLEEP
ON/OFF
TIMER
ENTER/
CANCEL
FAN SPEED
VAPS
TURBO/MILD
FAN DIR.
REMOCON
16
Indoor Unit
DSA-185L, 185P
Indoor Cover
Deodorizing Filter
Removes bad smells
from the air.
Test/Emergency/
Remote Switch
Slide to select
the desired position.
Indicators
Indicate the
AC setting.
Remote Sensor
Power PlugLCD Remote Controller
Air Cleaning
Filters
Removes dust
and prohibits
germs. Cold Air
Air In
Fan Direction
(Up/Down)
ON OFF ENTER CANCEL
TIMER RESET
FAN DIR.
FAN SPEED
MODE
SLEEP
ON/OFF
TEMP.
Removes small dust and
generates (-) ions.
(DSA-185P)
Electrostatic Filter
Removes dust particles
from the air
(DSA-185L)
Electric Dust Collector
(Air clean Plasma)
MODE
SLEEP
ON/OFF
TIMER
ENTER/
CANCEL
FAN SPEED
VAPS
TURBO/MILD
FAN DIR.
REMOCON
17
Indoor Cover
Deodorizing Filter
Removes bad
smells from the air.
Emergency/
Remote Switch
Indicators
Indicate the
AC setting.
Remote
Sensor
Power Plug
LCD Remote
Controller
Air Cleaning Filters
Removes dust and
prohibits germs.
AIR OUT
AIR IN
Fan Direction
(Up/Down)
MODE
SLEEP
ON/OFF
TIMER
ENTER/
CANCEL
FAN SPEED
TURBO/MILD
FAN DIR.
Removes small dust and
generates (-) ions.
(DSA-245P)
Electrostatic Filter
Removes dust particles
from the air
(DSA-245L)
Electric Dust Collector
(Air clean Plasma)
DSA-245L, 245P
MODE
SLEEP
ON/OFF
TIMER
ENTER/
CANCEL
FAN SPEED
VAPS
TURBO/MILD
FAN DIR.
REMOCON
18
Name of Each Button
2
REMOTE CONTROLLER
MODE
SLEEP PLASMA
ON/OFF
TIMER
ENTER/
CANCEL
FAN SPEED
TURBO/MILD
Display
Displays information
pertaining to unit.
( DSA-125P, 185P, 245P)
TURBO/MILD
Press to be colder the unit.
PLASMA Buttons
Press to clean the polluted air.
(DSA-125P, 185P, 245P)
TIMER ENTER/CANCEL Button
Press to enter a timer setting or
to cancel timer setting
TIMER ON/OFF Button
Press to set the unit of or on time.
(0.5, 1, 1.5, 2, 2.5, 3, 4, 5, 6, 8,
10, 12, 16, 20, 24hr)
MODE Button
Press to cycle through the modes
(Auto/Quick/Cool/Fan/Dehumidifier)
SLEEP Button
Press to set the unit for
the sleep mode.
FAN DIR. Button
Press to select up/down
direction for fan.
ON/OFF Button
Press to turn the unit
on or off.
TEMPERATURE Buttons
Press to raise or lower
the desired temperature.
FAN SPEED Button
Press to select the fan speed
(High " ", Middle " ",
Low " ").
COVER
Slide down to access most
of the remote buttons.
Slide down further to
access the battery
compartment.
AUTO
FAN DIR.
19
If you set time in OFF-Timer Mode, the unit will stop at the set time.
If you set time in ON-Timer Mode, the unit will run at the set time.
(1) Range of setting temperature: 18~32°C
(2) Setting temperature: Operating temperature of compressor
(3) During the time of test operating, Fan (Indoor, Outdoor) and Compressor is running regardless of room
temperature.
If the Indoor Unit Display receive the signal of Remote Controller, you can hear the signal "beep " or "beep,
beep".
(1) In the case of receiving ON/OFF signal-"beep" "beep"
(2) And so on-"beep"
OFF-Timer
3
DESCRIPTION OF FUNCTIONS
Unit ON
Unit OFF
SET Time HOUR
ON
OFF
ON-Timer
Unit ON
Unit OFF
SET Time HOUR
ON
OFF
Control of Room Temperature
Buzzer
COMP (ON)
*RT: ROOM TEMPERATURE
DT: DESIRED TEMPERATURE
COMP (OFF)
-1°C0°C
(COOLING)
(RT-DT)
+1°C
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98

Daewoo DSA-245L Specification

Category
Split-system air conditioners
Type
Specification
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI