at this stage and keep the job clean and free from dust.
Top boards first row
The top boards are laid in the same direction as the baseboards, but with the adhesive side down. The rst board of this
row is full size and positioned into the corner overlapping both the rst and second rows of baseboards. If the board ts
neatly into the corner no trimming is required, in which case it can be lifted out and the plastic lm can be peeled back
from the baseboards that it will cover. Avoid removing more lm than is necessary to accommodate the top board on the
adhesive. The top board is carefully repositioned and adjusted for alignment, at the same time the baseboards should
be checked for any gaps and adjusted if required; nally the top board is xed in place by tapping down with the rubber
mallet.
Top boards second row (Picture 2)
For the best result it is important to keep the joints
between the top boards as tight as possible.
The easiest way to achieve this is by starting the
second row of top boards with a half-length piece,
followed by a full board and pushing all the edges
tightly together before tapping down. Adding
further boards, alternately, to the rst two rows
keeps the lines straight and so prevents gaps from
developing.
Due to possible inuences of air humidity, glue the
oor covering on the Rointe Dual Overlay no later
than 48 hours.
Every room should be tted separately, leaving an
expansion gap of at least 8 -10 mm and 16mm
in door openings when Rointe Dual Overlay is
continued in the adjoining area.
If the oor covering is to be glued onto the total
surface and should not to exceed the edges of the
Rointe Dual Overlay Boards.
This method of installation will provide a stable
surface for the oor nish to rest on and avoid any
joints showing through the nal oor nish.
Now you have installed the Rointe Dual Overlay boards you can either glue your nal oor nish to the boards as a nal
layer or simply lay it freely upon them. Before installing the nal oor nish test the Rointe foil heater(s) and oor sensor to
ensure that no damage has occurred during the installation.
NOTE: If the oor nish is to be glued the underoor heating system must not be switched back on until the glue has
completely set. Temperatures should then be increased gradually.
If you need any further assistance regarding
the product all installation or operation of the
heaters please contact the Rointe Technical
Support help line on (UK) 0203 321 5928 or
(IRELAND) 01 553 0523.
Insulated Underlay
Model / Modelo / Modèle / Model
Under Carpet / Vinyl installation
Copyright © Rointe Heating 2021.
All rights reserved. As part of our policy of continuous improvement, we reserve the right to alter or modify
any product or specifications without prior notice. This also applies to products that have already been
ordered, provided that such alterations can be made without subsequent changes to the already agreed
specifications. We cannot accept responsibility for any errors in catalogues or other printed materials.
IMDIO21V1-ENG