Eaton i-on30EXDL Installation guide

Category
Security access control systems
Type
Installation guide

This manual is also suitable for

i-on30EXL
i-on30EXDL
Security System
Installation Guide
Issue 3
i-on30EXL/EXDL
Page ii
© Eaton’s Security Business. 2014
IN NO EVENT WILL EATON’S SECURITY BUSINESS BE LIABLE FOR ANY SPECIAL, CONSEQUENTIAL , OR INDIRECT LOSS OR
DAMAGE, INCIDENTAL DAMAGES, STATUTORY DAMAGES, EXEMPLARY DAMAGES, LOSS OF PROFITS, LOSS OF REVENUE,
LOSS OF ANTICIPATED SAVINGS, LOSS OF BUSINESS OR OPPORTUNTIY, LOSS OF GOODWILL OR INJURY TO
REPUTATION, LIQUIDATED DAMAGES OR LOSS OF USE, EVEN IF INFORMED OF THE POSSIBILITY OF SUCH DAMAGES.
EATON’S SECURITY BUSINESS’S LIABILITY FOR DAMAGES ARISING OUT OF OR RELATED TO A PRODUCT SHALL IN NO
CASE EXCEED THE PURCHASE PRICE OF THE PRODUCT FROM WHICH THE CLAIM ARISES. TO THE EXTENT PERMITTED
BY APPLICABLE LAW, THESE LIMITATIONS AND EXCLUSIONS WILL APPLY WHETHER EATON’S SECURITY BUSINESS’S
LIABILITY ARISES FROM BREACH OF CONTRACT, BREACH OF WARRANTY, TORT (INCLUDING BUT NOT LIMITED TO
NEGLIGENCE), STRICT LIABILITY, BY OPERATION OF LAW, OR OTHERWISE.
Every effort has been made to ensure that the contents of this book are correct. The contents of this book
are subject to change without notice.
This manual applies to the i-on30EXL and i-on30EXDL control units with version 4.04 software.
For Your Safety
This book contains several passages alerting you to potential problems or hazards. Each of these are
marked by the words Note, Caution or WARNING.:
Note:
Describes conditions that may affect the proper functioning of the equipment (but will not
damage the equipment).
Caution:
Describes actions that will physically damage the equipment and prevent its proper
function.
WARNING:
Describes actions that are hazardous to health, or cause injury or death.
Please pay particular attention to these marked passages.
Other Publications for the i-on30EXL/EXDL:
The following guides are available from the Eaton’s Security Business website: www.coopersecurity.co.uk
Quick User Guide
Brief instructions for setting and unsetting alarm systems based on i-
on control units.
i-onEX Range Engineering Guide
A detailed description of the Installer’s programming options
available for i-on control units.
i-onEX Range Administrator and
User’s Guide
Detailed notes for the system administrator of an alarm system
based on the i-on40, i-on30EX/EXD, i-on30EXL/EXDL, i-
on50EX/EXD and i-on160EX.
Eaton’s Security Business
Downloader Quick Guide
Instructions for how to installer Eaton’s Security Business
Downloader on your PC or laptop, and connect to i-on Control Units.
i-on Updater Utility Installation and
User Guide
Instructions on how to install i-on Updater on your PC and use it to
update the software on your i-on control unit.
i-on30EXL/EXDL
Page iii
CONTENTS
1. Introduction ....................................................... 1
Communications ................................................. 1
Part Setting or Partitioned System ..................... 1
Installer Programming Interface ......................... 2
About this Guide ................................................. 2
2. Before You Begin .............................................. 3
Preparation ......................................................... 3
Radio Site Survey .......................................... 3
Siting the Control Unit and Wired Zone
Expanders ...................................................... 3
Siting Keypads ............................................... 3
Siting Wireless Zone Expanders .................... 3
Guided Tour ........................................................ 4
Opening the Control Unit Case ...................... 4
i-kp01 Controls and Displays ......................... 7
Opening the i-kp01 Keypad ........................... 7
KEY-K01/KP01/KPZ01 Controls and Displays
....................................................................... 8
Opening the KEY-K01/KP01/KPZ01 .............. 8
Expanders ...................................................... 9
Power Availability ............................................. 12
Bus Cabling Requirements ............................... 12
Cable Type ................................................... 12
Cable Segregation ....................................... 12
Cable Configuration and Length .................. 12
Bus Termination ........................................... 13
Voltage Drop ................................................ 13
3. Installation ....................................................... 15
Caution: Static Electricity ............................. 15
Step 1. Fit the Control Unit Case...................... 15
Mark Fixing Points and Back Tamper .......... 15
Fitting Plastic Feet and Tamper Sleeve ....... 15
Fitting tamper Shroud .................................. 15
Fitting Case Back to Wall ............................. 15
Fitting the PCB ............................................. 15
Installing the Lid/Back Tamper..................... 16
Step 2. Run Bus Cable ..................................... 17
Step 3. Fit and Connect the Keypad(s) ............ 17
Siting the Keypad(s) ..................................... 17
Fitting Keypads ............................................ 17
Keypad Addressing ...................................... 17
Backlight Control for i-KP01 ......................... 18
Backlight Control for KEY-K01/KP01/KPZ01 18
Tone Volume All Keypads......................... 20
Engineering Keypad ..................................... 20
Step 4. Fit and Connect Expanders ................. 20
Connecting an Expander to the Bus ............ 21
Addressing Expanders ................................. 21
Expander Loudspeakers .............................. 21
Step 5. Connect Control Unit to Mains ............. 21
Mains Cabling .............................................. 21
Step 6. Connect Wired Zones .......................... 21
Four Wire Closed Circuit Connections ......... 21
Two-Wire Closed Circuit Connections ......... 22
Fully Supervised Loop Connections ............ 22
Step 7. Connect Wired Outputs........................ 24
Control Unit Wired Outputs .......................... 24
Wired External Sounders (Optional) ............ 24
Wired Outputs on Expanders ....................... 24
Wired External Sounders on Expanders ...... 24
Remote Loudspeakers (Optional) ................ 25
Output on KEY-KPZ01 ................................. 25
Step 8. Connect the Internal Communicator (i-
on30EXD only) ................................................. 26
Statutory Information .................................... 26
Safety Notice .................................................... 26
Connecting the Telephone Line ................... 27
Fit ADSL Filter .............................................. 27
Step 9. Fit a Plug-By Communicator ................ 28
Step 10. Fit and Connect Battery ..................... 29
Step 11. Initial Power-Up ...................................... 29
Transferring to Another Keypad ................... 30
Leaving the Installer Menu ........................... 30
Important! Saving Changes ......................... 31
Alerts After Leaving Installer Mode .............. 31
Re-Entering the Installer Menu .................... 31
Defaulting Access Codes ............................. 32
Restoring Factory Defaults Only .................. 32
Step 12. Commission the System .................... 33
Install Detectors and Other Peripherals ....... 33
Program the System .................................... 33
Handover to the User ................................... 33
Installer Menu ................................................... 34
4. Maintenance .................................................... 36
Replacing or Removing Wired Keypads ...... 36
5. Technical Specification .................................. 37
General ............................................................. 37
Capacities ......................................................... 37
Security ............................................................. 37
Power Supply ................................................... 37
EN50131-6 ratings ....................................... 38
Electromagnetic Compatibility .......................... 38
Outputs ............................................................. 38
Sounder Volume Levels (at 1m) .................. 38
Fuses ................................................................ 38
Electrical Safety ................................................ 38
Other ................................................................. 38
Radio Expander and Keypads ..................... 38
Compliance Statements ................................... 39
Compatible Equipment ..................................... 40
HUD ............................................................. 40
Detectors ...................................................... 40
Sounders ...................................................... 40
Setting / Unsetting Keypads ...................... 40
Setting / Unsetting - Fobs ............................ 40
Communicators ............................................ 40
Accessories .................................................. 40
i-on30EXL/EXDL
Page iv
This page is intentionally blank.
i-on30EXL/EXDL
Page 1
1. Introduction
The i-on30EXL/EXDL is a control unit for a hybrid
wired/wirefree alarm system intended for
commercial or large domestic use.
The control unit comprises a steel case containing
the control unit PCB (printed circuit board), power
supply and space for a 17Ah backup battery.
The control unit PCB provides terminals for a
single bus. The bus allows you to connect up to
10 devices using standard four wire alarm cable.
The bus devices can be any mixture of keypads,
zone expanders (for wireless or wired detectors)
or remote power supplies. Note that only two of
the 10-zone expanders connected to the system
can have detectors associated with them.
Similarly, only one 30-zone expander can have up
to 20 zones allocated to it.
The control unit PCB also provides a range of
connectors for outputs, communicators, and up to
10 Fully Supervised Loop (FSL), or 10 two-wire
Closed Circuit Loop (CCL) or five four-wire CCL
zones.
The i-on30EXL/EXDL at release 4.04 uses
keypads with software revision 2.0 and above.
The keypads allow end users to set and unset the
system, and the installer to configure the control
unit.
Note that to work correctly the i-on30EXL or i-
on30EXDL must be fitted with at least one wired
keypad.
The following types of keypad available for
connection to the i-on30EXL/EXDL:
i-kp01
This keypad contains an integral
proximity tag reader, allowing end
users to control the system without
having to remember access codes.
KEY-K01
This keypad has no internal prox
reader, and is supplied in a square
format case.
KEY-KP01
This keypad contains an internal
prox reader, and has the same
square format case as the KEY-
K01.
KEY-KPZ01
This product, supplied in the same
case as the KEY-K01, has an
internal prox reader and also
provides terminals for up to two
zones, a programmable output, and
an external prox reader KEY-EP
A range of wireless peripherals is available for
operation with the wireless expanders. The range
includes a door contact/universal transmitter, a
passive infra red detector, smoke detector,
external siren, 4 button remote control, and
remote radio keypad.
This control unit is designed and approved to be
used as part of a Security Grade 2 system.
Communications
The i-on30EXDL version of the control unit
contains a built-in ATS2 communicator, allowing it
to comply with EN50131 at Security Grade 2.
The i-on30EXL/EXDL also provides sockets for an
add-on communication module. The available
modules are:
A switched telephone network
(PSTN) module that allows the
control unit to report alarm
information using standard
protocols such as Fast Format, SIA
and Contact ID, and can also send
text messages over the Public
Switched Telephone Network
(PSTN). The i-dig02 also allows
remote maintenance using Eaton’s
Security Business Downloader
software.
A speech dialler and PSTN module
that allows the control unit to send
recorded speech messages and
report alarm information using
standard protocols such as Fast
Format, SIA and Contact ID. The
module can also send text
messages over the PSTN. The i-
sd02 also allows remote
maintenance using Eaton’s Security
Business Downloader software.
A GSM module that allows alarm
reporting, speech messaging and
SMS text messaging over the
mobile phone network. Note that a
SIM card is not included with the
module.
Note: Fitting a plug on module disables the
internal communicator in the i-on30EXDL.
The control unit also provides outputs that can be
used to fit a “plug by” communicator.
Part Setting or Partitioned
System
The i-on30EXL/EXDL offers two basic ways of
behaving as an alarm system:
Part Setting. In a Part Setting system the i-
on30EXL/EXDL can set in one of four ways: either
Full set or three varieties of Part Set. In Full set
the control unit pays attention to all detectors. In
each of the three Part Sets the control unit ignores
detectors that do not have the appropriate Part
Set attribute.
Partitioned System. In a Partitioned system the i-
on30EXL/EXDL provides the equivalent of 4,
Introduction i-on30EXL/EXDL
Page 2
smaller, independent alarm systems. Each system
is a “Partition” of the i-on30EXL/EXDL. You can
allocate any zone to each Partition. Each zone
can also belong to more than one Partition. Each
Partition can have a Full Set level and one Part
Set level. During installation the installer can
allocate keypads, sounders or outputs to any of
the partitions.
For a detailed description of the Installer’s
programming menu please read i-on Range
Engineering Guide available from
www.coopersecurity.co.uk.
Installer Programming
Interface
Once fitted and powered up, you can program the
control unit through any wired keypad connected
to the bus cable. The Installer Menu allows you to
specify all the operating parameters for an
individual installation.
If you wish, you can also connect a PC or laptop
to the mini USB port on the control unit PCB and
use Eaton’s Security Business’s Downloader
software to program the control unit.
Note: Some programming options can make the
installation non-compliant with EN50131. The
relevant options are noted in the “Installer Menu”
section of the i-on Range Engineering Guide.
About this Guide
This guide shows the simple procedure required
to physically install the control unit, connect
keypads, expanders and power supplies and
power up the system for the first time.
When you have completed the physical
installation please consult the i-on Range
Engineering Guide for details of configuring the
system to meet your customer’s requirements. For
your convenience page 34 of this installation
guide contains a condensed reference table of the
Installer menu.
i-on30EXL/EXDL
Page 3
2. Before You Begin
Preparation
Before installation you should carry out a survey
of the site. You need to know how many and what
kind of detectors will be monitored by the control
unit. You also need to assess where any radio
expanders must be placed in order to receive
radio signals from their detectors successfully.
Radio Site Survey
If you intend to fit radio expanders you should
conduct signal strength tests. Eaton’s Security
Business produces the Scantronic 790r hand held
signal strength meter and 734r-01 test transmitter
for this purpose. Please read the 790r manual for
details.
Please be aware of the following:
The 790r signal strength meter readings
should be used only as an guide when initially
checking the site.
A reading of four green LEDs or higher
indicates an acceptable signal strength.
Once you have installed the alarm system you
should put the control unit in the Installer test
menu and test the received signal strength
from each radio transmitter.
A signal strength reading of two or more units
by the control unit from each transmitter
should provide reliable operation in the
installed system. (Note: if you take the signal
strength using i-on Downloader or the web
server while the panel is in user mode then
the minimum acceptable signal strength is
four units. Ensure that the control unit is in
Installer mode when reading signal strengths
remotely.)
When you record the signal strength readings
for later inspection, you should record the
readings taken from the control unit of the
installed system while it is in the Installer
Menu.
Please be aware that the signal strength received
from a transmitter can change after installation
because of local environmental changes. For
example, users switching on laptops nearby, or
moving metal cabinets from their original position
can all affect the signal from a transmitter. Please
read Eaton’s Security Business publication
”Guidance Notes for Wireless Alarm System
Installations” obtainable from
www.coopersecurity.co.uk for more information
about the factors affection radio signal strength.
Siting the Control Unit and Wired Zone
Expanders
Do site the unit:
Upright, battery at the bottom. (This does not
apply to the wired zone expander.)
Within a protected zone.
Do NOT site the unit:
In the entry or exit zones, or outside the area
covered by the alarm system.
Next to electronic equipment, particularly
computers, photocopiers or other radio
equipment, CAT 5 data lines or industrial
mains equipment.
Where the cable run will exceed the capacity
of the bus, see page 12.
Siting Keypads
Do site the keypad:
Within the area protected by the alarm
system.
At a convenient height and location for the
user.
Out of sight of potential intruders.
Do NOT site the keypad:
Next to electronic equipment, particularly
computers, photocopiers or other radio
equipment, CAT 5 data lines or industrial
mains equipment.
Where the cable run will exceed the capacity
of the bus, see page 12.
If fitting two or more keypads make sure that you
place the keypads more than one metre apart
from each other, or from any other type of prox
reader. (At less than one meter separation the
proximity tag readers will interfere with each
other.) Remember not to place keypads or
external prox readers on opposite sides of the
same wall.
If you intend to fit external prox reader KEY-EP to
a KEY-KPZ01/KP01, then do not site the external
prox reader itself closer than one meter to any
other keypad or other type of prox reader.
Siting Wireless Zone Expanders
Do site the unit:
Upright.
Within a protected zone.
As high as possible. However, do make sure
that the unit is on a similar level to the
transmitters or receivers.
More than 10m from another radio expander.
Do NOT site the unit:
In the entry or exit zones, or outside the area
covered by the alarm system.
Before You Begin i-on30EXL/EXDL
Page 4
Close to or on large metal structures.
Closer than one metre to mains wiring, metal
water or gas pipes, or other metal surfaces.
Lower than two metres from the floor (ideally).
Inside metal enclosures.
Next to electronic equipment, particularly
computers, photocopiers or other radio
equipment, CAT 5 data lines or industrial
mains equipment.
Note: Some window glasses, especially those
sold as “insulating” or “energy conserving” may be
coated with thin metal or conducting films. These
glasses are particularly poor at transmitting radio
waves.
Guided Tour
CAUTION: All printed circuit boards for the i-
on30EXL/EXDL, its expanders and keypads have
been tested for Electromagnetic Compatibility
(EMC). However, when handling the PCBs you
must take the standard precautions for handling
static sensitive devices.
Opening the Control Unit Case
To gain access to the interior of the control unit
undo the screw at the bottom of the lid. Slide the
lid vertically up, then swing the bottom of the lid
out before moving the lid down and away from the
case.
Figure
1
Opening the Control Unit.
WARNING: When connected to the mains with
power applied mains voltages are present on the
shrouded heads of the terminal screws of the
mains connector.
i-on30EXL/EXDL Before You Begin
Page 5
0V 1 2V A B OP1 0V 12V AUX
-L S + STB BELLTR
Z0 Z1 Z2 Z3 Z4 Z5 Z6 Z7 Z 8 Z9
A B
PSTN
12V
BELL
0V
1
2
8
2
2
4
2
12
10
11
7
6
5
3 2
9
1. Case back.
2. Fixing holes.
3. Cable entry holes for detector
and keypad wiring.
4. Transformer.
5. Fused mains connector.
6. Mains cable anchor point.
7. Cable entry hole for mains
supply.
8. Hole for back tamper fitting.
9. Space for batteries (one 17Ah).
10. Cable entry holes for
loudspeakers, siren/strobes and
communicators.
11. Printed circuit board (PCB).
12. Plastic PCB tray.
Figure
2
Control Unit
0V 12V A B OP1 0V 12V AUX
- LS + STB BELLTR
Z0 Z1 Z2 Z3 Z4 Z5 Z6 Z7 Z8 Z9
A B
PSTN
12V
BELL
0V
1
11
9
10
8
13
15 1416
4
17
18
3
2
6
5
7
12
1. Connectors for system bus.
2. Zone-, output-, and Aux power
connectors.
3. Plug by output connectors.
4. Tamper switch connector.
5. ADSL filter pins. (i-on30EXDL only.)
6. On board communicator connections.
(i-on30EXDL only.)
7. Off-hook LED. (i-on30EXDL only.)
8. USB socket (Mini B).
9. Sockets for plug on module.
10.Loudspeaker, Bell and Strobe
connectors.
11. Comms activity LED. (i-on30EXDL
only.)
12. Reset Codes pins.
13. Heartbeat LED.
14. Kickstart pins.
15. Battery connectors.
16. RS485 terminator.
17. Engineering keypad connector.
18. 20Vac connector.
Figure
3
Control Unit Printed Circuit Board
Before You Begin i-on30EXL/EXDL
Page 6
1. Built-in communicator telephone
line connector. (i-on30EXDL only.)
2. Siren and strobe.
3. Loudspeaker.
4. Bus cable connector.
5. Output (transistorised).
6. Aux power.
7. Wired zone connectors.
Figure
4
Control Unit Main Connectors
i-on30EXL/EXDL Before You Begin
Page 7
i-kp01 Controls and Displays
2
3
4
6
5
8
7
1
1. LCD display (2 x 20 characters).
2. Programming keys.
3. Navigation keys
4. Alert LEDs
5. Setting and unsetting keys.
6. Programmable HUA keys.
7. Number/text keys.
8. Set/Unset LEDs.
Figure
5
Controls and Displays
Opening the i-kp01 Keypad
Note: For EN50131-3:2009, 8.7 the keypad is a
type B ACE, fixed.
To open the keypad first gently prise off the trim
on the front and remove the two screws. Next,
carefully lever the front of the keypad (containing
the PCB and display) away from the keypad rear
housing.
1
2
3
4
Figure
6
Opening the Keypad
2
4
3
3
1
1. Central keyhole.
2. Rear tamper shroud.
3. Cable entry.
4. Fixing holes.
Figure
7
Keypad Rear Housing
1. Sounder.
2. Sounder volume control.
3. Tamper switch.
4. Jumpers for LED function:
5. RS485 termination jumper
6. Connector for control unit (note that the ET
terminals are inactive).
Figure
8
Keypad PCB
Before You Begin i-on30EXL/EXDL
Page 8
KEY-K01/KP01/KPZ01 Controls and Displays
2
3
65 5
4
7
1
1. LCD display
2. Programming keys.
3. Navigation keys. This key has built-in alert
LEDs.
4. Setting and unsetting keys. The ABCD
keys have built-in status LEDs that can show
the setting status of a part setting system.
These LEDs can be disabled, see page 18.
5. Plastic caps covering screws (shown
closed and open).
6. Hold Up Alarm (HUA) keys.
7. Number/text keys.
Figure
9
KEY-K01/KP01/KPZ01 Controls and
Displays
Opening the KEY-K01/KP01/KPZ01
To open the unit, unclip the caps covering the
screws on the front. (You may need to gently push
the bottom edge of the caps in with the end of a
small screwdriver to start them.) Remove the two
screws hidden underneath (see Figure 9). Gently
swing the lower side of the front out from the back
box by about 10mm and then slide the front
upwards to disengage the top catches. (Be careful
not to pull the lower side of the front more than
about 25mm away from the back while the top
catches are engaged, or you may break the
catches.)
1
2
3
Figure
10
Opening the Keypad
1. Central keyhole.
2. Fixing holes.
3. Cable entry.
4. Tamper block
Figure
11
Keypad Rear Housing
1. Jumpers for addressing and LED function:
1a Addressing (not used for i-onEX)
1b LED functions
2. Sounder volume control.
3. Tamper switch.
4. Sounder.
5. Connector for control unit.
Figure
12
KEY-K01 Keypad PCB
1. Tamper switch.
2. Sounder.
3. Connector for KEY-EP.
4. Sounder volume control.
5. Connector for control unit bus.
6. Jumpers for:
i-on30EXL/EXDL Before You Begin
Page 9
6a Addressing (not used in i-onEX
control units).
6b LED functions and RS485 bus
termination.
Figure
13
KEY-KP01 Keypad PCB
2
3
4
BRIGHT
TERM
0V 12V A B
0V 12V D0 D1 LED
EXT READER
Z1 Z2
OP
1
6a
6b
3
4
5
6
2
1. Tamper switch.
2. Sounder.
3. Connector for KEY-EP. Terminals for
zones
4. Sounder volume control
5. Connector for data bus and output
terminal.
6. Jumpers for addressing and LED function:
6a Addressing (not used in i-onEX
control units)
6b LED functions and RS485 bus
termination.
Figure
14
KEY-KPZ01 Keypad PCB
Expanders
To open any of the expander cases undo the
single screw, pull the top of the lid away from the
case and then lift out.
Figures 15, 16 and 17 show the interior of the
wired and radio expanders.
Before You Begin i-on30EXL/EXDL
Page 10
1
1
2
3
1
8
7
5
6
4
10
9
11 12 13
10
1
16
15
14
1
17
18
19
1. Cable entry (also behind PCB).
2. Central keyhole.
3. PCB.
4. Relay card (i-rc01) connector.
5. Aux power.
6. Link to enable/disable front/rear
tamper switch.
7. Lid tamper (rear tamper behind pcb).
8. Zone connectors
9. Bus termination jumper.
10. Fixing holes.
11. Addressing button.
12. Engineering keypad connector
13. Bus cable connector.
14. Sounder.
15. Zone connectors.
16. Bus address display.
17. Aux power.
18. Loudspeaker connectors.
19. Outputs.
Figure
15
EXP-W10 Wired Expander
1
1
2
3
1
8
7
5
6
4
10
9
11 12 13
10
1
16
15
14
1
17
18
19
1. Cable entry (also behind PCB).
2. Central keyhole.
3. PCB.
4. Relay card (i-rc01) connector.
5. Aux power.
6. Link to enable/disable front/rear
tamper switch.
7. Lid tamper (rear tamper behind pcb).
8. Zone connectors
9. Bus termination jumper.
10. Fixing holes.
11. Engineering keypad connector.
12. Addressing button.
13. Bus cable connector.
14. Sounder.
15. Zone connectors.
16. Bus address display.
17. Aux power.
18. Loudspeaker connectors.
19. Outputs.
Figure
16
EXP-WCC Wired Expander
i-on30EXL/EXDL Before You Begin
Page 11
1
4
3
2
1
5
6
1
8
7
9
10
11
9
12
13
1
14
1
1. Cable entry (also behind PCB).
2. Antenna.
3. Central keyhole.
4. PCB.
5. Link to enable/disable front/rear
tamper switch.
6. Lid tamper (rear tamper behind
PCB).
7. Bus termination jumper.
8. Addressing button.
9. Fixing holes.
10. Engineering keypad connector
11. Bus cable connector.
12. Sounder.
13. Loudspeaker terminals.
14. Bus address display.
Figure
17
EXP-R10/30 Radio Expander
Before You Begin i-on30EXL/EXDL
Page 12
Power Availability
Before connecting any external devices to the
control unit, you must make sure that the control
unit can provide sufficient current to power the
system during a mains failure for the time required
to meet the appropriate standard.
EN51031-1 Grade 2 and PD6662 Grade 2 both
require 12 hours standby time.
Note: When calculating the average load during
the standby time period you must allow for at least
two periods in alarm. To take the worst case these
two periods of alarm should each be 15 minutes
long, the maximum permitted in EN50131-1
section 8.6.
The amount of current available from the control
unit depends on the size of battery fitted and its
health. The current taken by the control unit PCB,
communicator and keypads is given in Technical
Specifications EN50131-6 Ratings on page 37.
The following calculation shows a simplified
example: in an alarm system with an i-
on30EXL/EXDL control unit, two i-kp01 keypads,
and 15 wired PIRs the system takes the following
total quiescent current:
Device
Current
Control unit PCB
100mA
15x PIRs at 15mA each
225mA
15 wired door contacts @2mA
each
30mA
2 x (wired expander @ 40mA
each)
40mA
4 x i-kp01 at 30mA each
(backlights off)
120mA
4 x Sirens (quiescent) at 25mA
each
100mA
Total
615mA
During an alarm, these figures become:
Device
Current
Control unit PCB
120mA
15 x PIRs at 15mA each
225mA
15 wired door contacts @2mA
each
30mA
2 x (wired expander)
40mA
4 x i-kp01 at 60mA each
(backlights off)
240mA
4 x Sirens (in alarm) at 400mA
each
1600mA
Total
2255mA
The total amp hours required =
(0.615 A x 11.5h) + (2.255A x 0.5h) = 8.2Ah
One new, fully charged,17Ah battery can provide
the charge required by the example system and
would meet the Grade 2 requirements.
Note: All current drawn from the Aux terminals
(12V) must be included in the overall calculation.
CAUTION: Ensure that the system does not
demand more than the maximum current available
from the control unit during an alarm, see page
37.
Bus Cabling Requirements
Cable Type
In general, the control unit requires standard 7/0.2
un-screened four core alarm cable for wiring the
bus.
For maximum performance in harsh environments
use twisted pair screened cable with a
characteristic impedance of 100-120ohms eg:
Belden 8132 or cable designed for RS485.
Use one pair for data lines A and B. Use the other
pair for 12V and 0V. For optimum performance
the voltage at the keypads and expanders should
be greater than 12V.
Screened cable may prove necessary if the
installation site has equipment that produces high
levels of R.F. (Radio Frequencies). For example,
welding equipment is known to produce a large
amount of radio interference. If screened cable is
required, you should keep to the following
guidelines:
1. Avoid earth loops by connecting the screen on
the cable to mains earth at the control unit but
nowhere else.
2. The continuity of the cable screen is most
important and screens MUST be continuous
along the full length of the cable.
3. Where the cable enters any metal enclosure,
ensure the screen is isolated from the case.
Cable Segregation
Segregate the bus cabling from any other wiring,
such as mains supply cables, telephone cables,
computer network cables and R.F. cables. Use
cable ties to keep cables separated.
Keep the bus cable clear of cables supplying
sounders, extension loudspeakers or any other
high current devices.
Cable Configuration and Length
You can connect up to 10 devices to the control
unit bus. You may connect the devices either in
daisy chain (serially), or in star (parallel)
configuration at the control unit connector.
i-on30EX Before You Begin
Page 13
Figure
18
Bus Wiring Configurations
For star configurations the cable length from
control unit to the most distant bus device should
be kept short, and should not exceed 100m.
There should be no more than four arms in the
star.
For a daisy chain configuration the total cable
length should not exceed 1,000m.
Bus Termination
The i-on30EXL/EXDL bus uses the RS485
interface. Because of this the ends of the line in
some configurations may be terminated to
improve performance in electrically noisy
environments or where there are long cable runs.
The control unit. expanders and keypads have a
termination link on their PCBs (see 16 in Fig 3 for
the control unit, 5 in Fig 8 for the keypad, 12 in Fig
15 for the wired expander and 11 in Fig 17 for the
radio expander). Fitting a jumper to the pins adds
a termination to the cable.
In a daisy chain configuration fit the termination
jumpers in the devices at each end of the chain
(see Fig 18 ).
In a star configuration:
If there are only two arms on the star then this
is the same as a daisy chain configuration
(see “Daisy Chain 1” in Figure 18). If required
fit the termination jumper at the devices on
the end of each arm.
If there are more than two arms AND two
cables are long while the remaining cables
are short (less than 10m) then it is possible to
terminate at the two devices on the ends of
the long cables.
If there are more than two arms BUT each
cable is more than 10m then DO NOT fit the
termination jumpers on any of the devices.
Voltage Drop
In order for the system to work correctly, the
voltage at each device must NOT drop below
10.5V even when running on the standby battery.
Eaton’s Security Business recommends that the
voltage at each device should stay above 12V.
Standard 7/0.2 alarm cable has a resistance of 8
Ohms per 100m per core. The voltage drop is
calculated using the following formula: V Drop =
Current drawn x cable length x 0.08 x 2.
Table 1 shows the voltage drop against the
current drawn and cable length.
The shaded area shows where the voltage drop
would cause the bus voltage to fall from 13.8V to
below 12.0V when using a single core.
Before You Begin i-on30EXL/EXDL
Page 14
Table 1. Voltage Drop
Current
Drawn
Cable Length (Standard 7/0.2 alarm cable)
10m
20m
30m
40m
50m
60m
70m
80m
90m
100m
60mA
0.10V
0.19V
0.29V
0.38V
0.48V
0.58V
0.67V
0.77V
0.86V
0.96V
80mA
0.13V
0.26V
0.38V
0.51V
0.64V
0.79V
0.90V
1.02V
1.15V
1.28V
100mA
0.16V
0.32V
0.48V
0.64V
0.80V
0.96V
1.12V
1.28V
1.44V
1.60V
120mA
0.19V
0.38V
0.58V
0.79V
0.96V
1.15V
1.34V
1.54V
1.74V
1.92V
140mA
0.22V
0.45V
0.67V
0.90V
1.12V
1.34V
1.57V
1.79V
2.02V
2.24V
160mA
0.26V
0.51V
0.77V
1.02V
1.28V
1.54V
1.79V
2.05V
2.30V
2.56V
180mA
0.29V
0.58V
0.86V
1.15V
1.44V
1.73V
2.02V
2.30V
2.59V
2.88V
200mA
0.32V
0.64V
0.96V
1.28V
1.60V
1.92V
2.24V
2.56V
2.88V
3.20V
220mA
0.35V
0.70V
1.06V
1.41V
1.76V
2.11V
2.46V
2.82V
3.17V
3.52V
240mA
0.38V
0.79V
1.15V
1.54V
1.92V
2.30V
2.69V
3.07V
3.46V
3.84V
260mA
0.42V
0.83V
1.25V
1.66V
2.08V
2.50V
2.91V
3.33V
3.74V
4.16V
280mA
0.45V
0.90V
1.34V
1.79V
2.24V
2.69V
3.14V
3.58V
4.03V
4.48V
300mA
0.48V
0.96V
1.44V
1.92V
2.40V
2.88V
3.36V
3.84V
4.32V
4.80V
320mA
0.51V
1.02V
1.55V
2.05V
2.56V
3.07V
3.58V
4.10V
4.61V
5.12V
340mA
0.54V
1.09V
1.63V
2.18V
2.72V
3.26V
3.81V
4.35V
4.90V
5.44V
360mA
0.58V
1.15V
1.73V
2.30V
2.88V
3.46V
4.03V
4.61V
5.18V
5.76V
380mA
0.61V
1.22V
1.82V
2.43V
3.04V
3.65V
4.26V
4.86V
5.47V
6.08V
400mA
0.64V
1.28V
1.92V
2.56V
3.20V
3.84V
4.48V
5.12V
5.76V
6.40V
Reducing Voltage Drop - Method 1:
Double up the supply connections (12V and 0V),
which will halve the resistance on each core and
therefore halve the voltage drop. When using
Table 1 to calculate the expected voltage drop,
simply divide the voltage drop for a single core by
two.
Reducing Voltage Drop - Method 2:
Supply the detection devices from the Aux output
on separate cores. This is the preferred method of
reducing voltage drop as detectors generally
operate at lower voltages (9.5V). When using this
method, the bus cable must have at least two
spare cores.
Remote Power Supplies
When you cannot reduce voltage drops by
method 1 or 2, or the demand on the control unit
power supply exceeds its capacity (see Technical
Specifications page 37), you should install one or
more remote power supplies. The supply must
have a "floating zero Volt rail" if connected to the
bus, otherwise an earth fault will occur. Eaton’s
Security Business recommends the EXP-PSU.
When installing a remote power supply, fit it close
to the equipment it is powering.
Figure 19 shows the recommended method of
connecting a remote power supply.
Control unit
Device 1
12V
0V
0V 12V
Bus
Device 2
Remote PSU
Device 4
Device 3
Figure
19
. Connecting Remote Power Supply Units
i-on30EXL/EXDL
Page 15
3. Installation
Note: The installation steps listed below assume
that you have already decided on the required
number and location for all keypads, expanders
and power supplies.
Caution: Static Electricity
Like many other electronic products, the control
unit, keypads and expanders contain components
that are sensitive to static electricity. Try not to
handle their PCBs directly. If you must handle a
PCB, take the standard precautions against
damage by static electricity.
Step 1. Fit the Control Unit
Case
Mark Fixing Points and Back Tamper
To prevent access to the inside of the control unit
through the holes in the rear of the case you must
mount the control unit on a wall or other flat
surface.
The case must be vertical, as shown in Figure 2.
Locate and mark the position of at least three
fixing holes. Figure 2 shows the fixing holes and
cable entries.
WARNING Ensure that the wall is strong enough
to support the weight of the control unit, its lid and
17Ah lead acid battery. The total weight of the
control unit plus batteries can be up to 11kg.
Also, mark the position where the lid/back tamper
bracket touches the wall. There must be enough
space around this point to fit the supplied tamper
shroud (see Figure 21).
Fitting Plastic Feet and Tamper Sleeve
The control unit is supplied from the factory with
four plastic feet and one plastic tamper sleeve. Fit
these onto the outside of the case back, as shown
in Figure 20. Fit feet only to the fixing holes that
you intend to use.
Fitting tamper Shroud
The tamper shroud is intended to prevent an
intruder sliding a tool between case and wall to
interfere with the tamper bracket. When fitted the
shroud must surround the tamper sleeve and the
point where the tamper bracket touches the wall.
see Figure 21
Figure
20
Fitting Feet and Tamper Sleeve.
Figure
21
Fitting Tamper Shroud.
Fitting Case Back to Wall
Use No14/M6 screws at least 50mm long,
inserted into wall anchors appropriate for the type
of wall.
WARNING Ensure that the fixings are strong
enough to support the weight of the control unit,
its lid and 17Ah lead acid battery. The total weight
of the control unit plus batteries can be up to
11kg.
Protect the unit from dust and drilling debris when
drilling the fixing holes.
Fitting the PCB
The control unit PCB is supplied in a separate
carton designed to store it safely if you wish to fit
the pcb some time after you have fitted the case.
Clip the plastic PCB carrier into the holes
provided, see Figures 22 to 24.
Installation i-on30EXL/EXDL
Page 16
Figure
22
Insert Tabs
Figure
23
. Push Home Clips
Figure
24
Fit Securing Screw
When the PCB is in place, connect the wires from
the transformer to the 20Vac connector on the
PCB (11 in Figure 3).
Installing the Lid/Back Tamper
Figure
25
Lid/Back Tamper
Fit combined lid/back tamper bracket and switch
(provided). Ensure that the switch is oriented as
shown in Figure 25.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44

Eaton i-on30EXDL Installation guide

Category
Security access control systems
Type
Installation guide