Taylor Technologies K-1683 Owner's manual

Type
Owner's manual
COMPONENT SHEET
K-1683 BOILER/COOLING SYSTEM WATER TESTS
COMPONENTS:
P Alkalinity
1 x 5228 Instruction
*1 x R-0638G-C Phenolphthalein Indicator, 2 oz w/ green cap, DB
*1 x R-0687G-C Sulfuric Acid .12N, 2 oz w/ green cap, DB
Free Chelant (NTA)
2 x 2269 Cap, Dispenser, 18 mm, white
1 x 4027 Funnel, 58 mm, plastic
1 x 4030 Pipet, Calibrated (0.5 & 1.0 mL) w/ cap, plastic
1 x 5529 Instruction
1 x 6009 Filter Paper, 9.0 cm, #610, 100/box
*1 x R-0620B-I Hardness Indicator Powder, 10 g w/ blue dot
1 x R-0877-C Magnesium Chloride Reagent, 2 oz, DB
1 x R-0878-C NTA Buffer Solution, 2 oz
2 x R-0879-C NTA Cosolvent Solution, 2 oz
Chloride
1 x 5212 Instruction
1 x R-0630-C Chromate Indicator, 2 oz, DB
*1 x R-0638G-C Phenolphthalein Indicator, 2 oz w/ green cap, DB
*1 x R-0687G-C Sulfuric Acid .12N, 2 oz w/ green cap, DB
1 x R-0706C Silver Nitrate Reagent, 2 oz, DB
Total Hardness
1 x 5202 Instruction
1 x R-0619B-C Hardness Buffer, 2 oz w/ blue cap, DB
*1 x R-0620B-I Hardness Indicator Powder, 10 g w/ blue dot
1 x R-0683-C Hardness Reagent, 2 oz, DB
31 Loveton Circle, Sparks, MD 21152 U.S.A.
800-TESTKIT(837-8548) • 410-472-4340 7/16
Sodium Sulfite
1 x 5203 Instruction
*1 x R-0638G-C Phenolphthalein Indicator, 2 oz w/ green cap, DB
1 x R-0699-C Iodide Iodate Reagent, 2 oz, DB
1 x R-0725-I Acid Starch Indicator Powder, 10g
Misc.
1 x 5518 Instruction (Component Sheet)
2 x 9198 Sample Tube, Graduated (25 mL) w/ cap, plastic
*Kit includes one.
TO ORDER REPLACEMENT PARTS AND REAGENTS CALL TOLL-FREE
800-TEST KIT (800-837-8548).
Instr. #5518
DROP TEST
FREE CHELANT (1 drop = 10 ppm NTA)
COMPONENTS:
2 x 2269 Cap, Dispenser, 18 mm, white
1 x 4027 Funnel, 58 mm, plastic
1 x 4030 Pipet, Calibrated (0.5 & 1.0 mL) w/ cap, plastic
1 x 5529 Instruction
1 x 6009 Filter Paper, 9.0 cm, #610, 100/box
1 x 9198 Sample Tube, Graduated (25 mL) w/ cap, plastic
1 x R-0620B-I Hardness Indicator Powder, 10 g w/ blue dot
1 x R-0877-C Magnesium Chloride Reagent, 2 oz, DB
1 x R-0878-C NTA Buffer Solution, 2 oz
2 x R-0879-C NTA Cosolvent Solution, 2 oz
TO ORDER REPLACEMENT PARTS AND REAGENTS CALL TOLL-FREE
800-TEST KIT (800-837-8548).
PROCEDURE:
CAREFULLY READ AND FOLLOW PRECAUTIONS ON REAGENT LABELS.
KEEP REAGENTS AWAY FROM CHILDREN.
NOTE: When dispensing reagents from dropper bottles or pipets, always hold bottle/pipet
in a vertical position.
Free Chelant Test
1. Filter water to be tested to clarify.
2.Rinseandll25mLsampletube(#9198)to10mLmarkwithlteredsample.
3.Usinga1.0mLpipet(#4030),add0.5mLR-0878NTABuerSolution.Swirltomix.
31LovetonCircle,Sparks,MD21152U.S.A.
800-TESTKIT(837-8548) • 410-472-4340 7/16
Instr. #5529
4.Cap R-0879 NTA Cosolvent Solution with dispenser cap (#2269). Add R-0879 NTA
CosolventSolutionto20.5mLmark.Swirltomix.
5.Add1leveldipperR-0620BHardnessIndicatorPowder.Swirltomix.Samplewillturnblue
if chelant is present.
6.AddR-0877MagnesiumChlorideReagentdropwise,swirlingandcountingaftereachdrop,
untilcolorchangesfrombluetored.
7.MultiplydropsofR-0877MagnesiumChlorideby10.Recordaspartspermillion(ppm)free
chelantasNTA(nitrilotriaceticacid).
COMPONENTS:
1 x 5202 Instruction
1 x 9198B Sample Tube, Graduated (25 mL) w/ cap & blue dot, plastic
1 x R-0619B-C Hardness Buffer, 2 oz w/ blue cap, DB
1 x R-0620B-I Hardness Indicator Powder, 10 g w/ blue dot
1 x R-0683-C Hardness Reagent, 2 oz, DB
TO ORDER REPLACEMENT PARTS AND REAGENTS CALL TOLL-FREE
800-TEST KIT (800-837-8548).
PROCEDURE:
CAREFULLY READ AND FOLLOW PRECAUTIONS ON REAGENT LABELS.
KEEP REAGENTS AWAY FROM CHILDREN.
NOTE: When dispensing reagents from dropper bottles, always hold bottle in a
vertical position.
Total Hardness Test
1.Rinseandll25mLsampletube(#9198B)to25mLmarkwithwatertobetested
(Fig.1).
NOTE: Forresultsingrainspergallon(gpg),llto14.6mLmark.
2.Add5dropsR-0619BHardnessBuer.Swirltomix.
3.Add1dipperR-0620BHardnessIndicatorPowder.Swirluntildissolved.Sample
willturnred(Fig.2)ifhardnessispresent.
4.AddR-0683HardnessReagentdropwise,swirlingandcountingaftereachdrop,
untilcolorchangesfromredtoblue(Fig.3).
DROP TEST
TOTAL HARDNESS (1 drop = 10 ppm)
5.MultiplydropsofR-0683HardnessReagentby10.Recordaspartspermillion
(ppm)totalhardnessascalciumcarbonate.
NOTE: For14.6mLsample,recorddropsasgrainspergallon(gpg)totalhardness
ascalciumcarbonate.
Fig. 1
Fig. 2
Fig. 3
Instr. #5202
31LovetonCircle,Sparks,MD21152U.S.A.
800-TESTKIT(837-8548)•410-472-4340 7/16
COMPONENTS:
1 x 5203 Instruction
1 x 9198W Sample Tube, Graduated (25 mL) w/ cap & white dot, plastic
1 x R-0638W-C Phenolphthalein Indicator, 2 oz w/ white cap, DB
1 x R-0699-C Iodide Iodate Reagent, 2 oz, DB
1 x R-0725-I Acid Starch Indicator Powder, 10 g
TO ORDER REPLACEMENT PARTS AND REAGENTS CALL TOLL-FREE
800-TEST KIT (800-837-8548).
PROCEDURE:
CAREFULLY READ AND FOLLOW PRECAUTIONS ON REAGENT LABELS.
KEEP REAGENTS AWAY FROM CHILDREN.
NOTE: When dispensing reagents from dropper bottles, always hold bottle in a
vertical position.
Sodium Sulfite Test
NOTE: Sample must be cooled to less than 100ºF (38ºC) to prevent high test
results. Sample must be protected from air contact while cooling to prevent
low test results.
1.Collectwatertobetestedinaclean,preferablylarge-mouthed,bottletooverowing.
Immediately cap and cool to room temperature.
2.Rinseandll25mLsampletube(#9198W)to25mLmarkwithcooled(room
temperature) water to be tested (Fig. 1).
NOTE: Forresultsingrainspergallon(gpg),llto14.6mLmark.
DROP TEST
SODIUM SULFITE (1 drop = 10 ppm)
3.Add1dropR-0638WPhenolphthaleinIndicator.Swirltomix.Samplewillturn
pink(Fig.2).
4.AddR-0725AcidStarchIndicatorPowderadipperatatime,swirlingaftereach
dipper, untilcolorchanges from pinktocolorless. Add2 moredippers. Swirl
until dissolved.
5.AddR-0699IodideIodateReagentdropwise,swirlingandcountingaftereach
drop, until sample changes from colorless to a faint but permanent blue (Fig. 3).
6.Multiply drops of R-0699 Iodide Iodate Reagent by 10. Record as parts per
million(ppm)sodiumsulte.
NOTE: For14.6mLsample,recorddropsasgrainspergallon(gpg)sodiumsulte.
NOTE:Forresultsassulte,multiplysodiumsulteconcentrationby0.64.
Fig. 1
Fig. 2
Fig. 3
Instr. #5203
31LovetonCircle,Sparks,MD21152U.S.A.
800-TESTKIT(837-8548)•410-472-4340 9/16
DROP TEST
CHLORIDE (1 drop = 10 ppm)
COMPONENTS:
1 x 5212 Instruction
1 x 9198 Sample Tube, Graduated, 25 mL, plastic w/cap
1 x R-0630 Chromate Indicator, DB
1 x R-0638 Phenolphthalein Indicator, DB
* 1 x R-0686 Sulfuric Acid N, DB
* 1 x R-0687 Sulfuric Acid .12N, DB
1 x R-0706 Silver Nitrate Reagent, DB
* 1 x R-0736 Sulfuric Acid .6N, DB
* Kit may only contain one of these reagents.
TO ORDER REPLACEMENT PARTS AND REAGENTS CALL TOLL-FREE 800-TEST KIT
(800-837-8548).
PROCEDURE:
CAREFULLY READ AND FOLLOW PRECAUTIONS ON REAGENT LABELS.
KEEP REAGENTS AWAY FROM CHILDREN.
NOTE: Whensultecontentofsamplewatertobetestedexceeds10ppm,thesulteshould
beoxidizedtopreventinterferenceintest.A25mLsampleisrstadjustedtotheap-
propriatepH,then1mL(or24drops)ofR-06493%HydrogenPeroxideSolution(sold
separately)isaddedandthoroughlymixed.Continuewiththerestoftheprocedure.
1.Rinseandll25mLsampletube(#9198)to25mLmarkwithwatertobetested.
NOTE: Forresultsingrainspergallon(gpg),llto14.6mLmark.
2.Add2dropsR-0638PhenolphthaleinIndicator.Ifcolorless—proceedtoStep3.Ifred,add
R-0686SulfuricAcidN,R-0687SulfuricAcid.12N,orR-0736SulfuricAcid.6Ndropwise,
swirlingaftereachdrop,untilcolorchangesfromredtocolorless.
31LovetonCircle,Sparks,MD21152U.S.A.
800-TESTKIT(837-8548) • 410-472-4340 5/08
3.Add5dropsR-0630ChromateIndicator.Swirltomix.Sampleshouldturnyellow.
4.AddR-0706SilverNitrateReagentdropwise,swirlingandcountingaftereachdrop,untilcolor
changesfromyellowtoamilkysalmon(brick)red.Alwaysholdbottleinverticalposition.
NOTE: DonotaddenoughR-0706SilverNitrateReagenttogiveabrowncolor.Firstchange
fromyellowtoamilkysalmon(brick)redistheendpoint.
5.MultiplydropsofR-0706SilverNitrateReagentby10.Recordaspartspermillion(ppm)
chloride.For14.6mLsample,recorddropsasgrainspergallon(gpg)chloride.
Instr. #5212
DROP TEST
P ALKALINITY (1 drop = 10 ppm)
COMPONENTS:
1 x 5228 Instruction
1 x 9198 Sample Tube, Graduated, 25 mL, plastic w/cap
1 x R-0638 Phenolphthalein Indicator, DB
1 x R-0687 Sulfuric Acid .12N, DB
TO ORDER REPLACEMENT PARTS AND REAGENTS CALL TOLL-FREE 800-TEST KIT
(800-837-8548).
PROCEDURE:
CAREFULLY READ AND FOLLOW PRECAUTIONS ON REAGENT LABELS.
KEEP REAGENTS AWAY FROM CHILDREN.
1.Rinseandll25mLsampletube(#9198)to25mLmarkwithwatertobetested.
NOTE: Forresultsingrainspergallon(gpg),llto14.6mLmark.
2.Add 3 drops R-0638 Phenolphthalein Indicator. Sample will turn pink if P alkalinity is
present.
3.Ifpink,addR-0687SulfuricAcid.12Ndropwise,swirlingandcountingaftereachdrop,until
colorchangesfrompinktocolorless.Alwaysholdbottleinverticalposition.
31LovetonCircle,Sparks,MD21152U.S.A.
800-TESTKIT(837-8548) • 410-472-4340 3/90
4.MultiplydropsofR-0687SulfuricAcidNby10.Recordaspartspermillion(ppm)Palkalinity
as calcium carbonate. For 14.6 mL sample, record drops as grains per gallon (gpg) P
alkalinityascalciumcarbonate.
Instr. #5228
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

Taylor Technologies K-1683 Owner's manual