Luminaire
Manual
Labels for 3 & 8 hours duration
Lens Accessories
Mounting Accessories
General
Package Contents
Indications
Installation Instructions
Lens Installation
Anti-Panic
Escape Route
923795001_09_001 923795001_09_001
2
4
1
In order to place the proper lens (Anti - Panic or Escape Route), first be sure that the luminaire is
not connected in the mains power supply and the battery is disconnected. Place the proper lens
and retaining cover on the luminaire. Be careful not touch the LED with your hand.
In order to change the lens, be sure that the luminaire is not connected to the mains power
supply and the battery is disconnected. Use a flat bladed screwdriver to remove the retaining
cover, remove the placed lens and insert the new one with its retaining cover.
Be careful not to touch the LED with your hand.
Dimensions
3
110mm 40mm 70mm
The arrows show the light direction
for Escape Route Lens
Dip Switch Positions (DS1)
ON
1 2 3 4
ON
1 2 3 4
ON
1 2 3 4
1h
(default position) 3h 8h
Place a flat blade screwdriver on the 5 marked positions and swift it, pull up gently the
bottom cover and remove it.
Mount the bottom cover on the ceiling, make sure that the light direction is correct (marked
in bottom cover).
Pass the mains cable through the hole and connect
them to the terminal blocks. L for live wire N for
neutral. The ground terminal is for termination
purposes only. To connect the luminaire with the
addressable panel, pass the 2 signal cables and
connect them on the C1 and C2 terminals, minding
the correct polarity. Set the luminaire address via
the dip switch. For the different address dip switch
settings, see the extra leaflet.
The user can select one of the 3 available minimum autonomy
durations: 1 hour, 3 hours and 8 hours. The selection must be
done while the luminaire is disconnected from AC and battery
supplies. The selection is achieved through Switches 2 & 3 of
DS1. Switches 1 and 4 are not used.
Two additional labels are included in the package, one for 3 hours duration (180) and one for
8 hour duration (480). Depending on the selected duration, the installer must cover the
default 1 hour (60) printing with one label that has the required duration. Please take notice
of the orientation of the label.
Red LED
(Battery/Lamp Fault)
Green LED
(Charge)
Automatic Operational Test
o
These devices are used indoors (ta 40 C) in places
where emergency light is needed. Each device must
be permanently connected to mains power supply.
In normal operation the battery is charging. In case
of a mains power supply failure, the device enters
emergency mode and the illumination LED turns on.
When the mains power supply is restored the
device turns to normal operation.
Automatic Autonomy Test
This test is conducted automatically every 15 days
and lasts 3 seconds. The light source and the
emergency circuit of the device are tested. The test
can be conducted only if the mains power supply
and the battery are connected. During this test
period the light source will light up and the green
LED will flash quickly. The battery must have
adequate charge.
The Automatic Autonomy Test is conducted every 6
months and measures the device’s back up
operation and emergency duration. In order to be
performed, the mains power supply should be
connected and the battery should be fully charged.
During this test period the light source will light up
and the green LED will flash quickly. This test lasts for
the stated duration. In case the test shows a battery
fault, then the battery needs to be replaced. After
the replacement, the luminaire will charge the
battery. When the charge is finished, the luminaire
will perform an automatic autonomy test which lasts
for the stated duration. If the battery is in good
condition then the LED indicator will turn off.
The luminaire has the ability to be connected to the
Olympia Electronics addressable panels. In order to
do so, the luminaire’s address has to be unique in
the same bus. For the different address dip switch
settings, see the extra leaflet.
ΑΤΤΕΝΤΙΟΝ!!!
1. Operations for installation, maintainance or
testing must be done by authorized personnel
only.
2. Always use in any case round mains cable, with a
diameter of 5-10mm (H05RN-F type 2x1mm² or
any other type, at least equal to it’s mechanical
and electrical properties). ATTENTION!! The cable
must not be deformed in any way (This
requirement is important to ensure the ΙΡ rating).
3. The device must be connected to the mains
power supply through a circuit breaker that is
depends on the total line’s power load.
4. In case of battery replacement, it must be
replaced by the same type, by the manufacturer
or a competent person.
5. In case of inactive use for a period greater than 2
months, disconnect the battery by pulling out the
battery’s connector.
6. I s not allowed to discard batteries into t i
common trash bins, they must be discarded
only in battery recycling points. Do not
incinerate.
Addressable Communication
Indications LED Status
Description
GREEN
(charge)
Normal
Charging
(battery test not possible whilte charging)
Mains off
(battery not connected or charger fault)
Light Source Test (Duration: 3s)
Light Source Fault
Battery Test (Duration: 1h, 3h, 8h)
Battery Fault
Battery Fault & Light Source Fault
RED
(Batt./Lamp
Fault)
Note:
Permanently
ON
Fast Blink
Slow Blink
Off
Power & Communication Connections
N for Neutral, L for Live wire
Dip Switch Settings
N
L
B-C2
A-C1
NLPEC1C2
From the
Panel