OKM GeoSeeker is an advanced 3D ground scanner with versatile applications in archaeology, geology, and civil engineering. With its cutting-edge technology, it offers a wide range of scanning modes and configurations, empowering you to tailor your surveys to specific needs.

  • Accurate and in-depth ground analysis: GeoSeeker employs active and passive scanning modes to provide highly detailed and precise measurements. Its variable depth range and resolution settings allow you to customize scans based on your objectives.
  • Comprehensive data visualization: The intuitive software seamlessly integrates with the GeoSeeker, enabling real-time data visualization during scans. This allows you to monitor progress, identify anomalies, and make informed decisions on-site.

OKM GeoSeeker is an advanced 3D ground scanner with versatile applications in archaeology, geology, and civil engineering. With its cutting-edge technology, it offers a wide range of scanning modes and configurations, empowering you to tailor your surveys to specific needs.

  • Accurate and in-depth ground analysis: GeoSeeker employs active and passive scanning modes to provide highly detailed and precise measurements. Its variable depth range and resolution settings allow you to customize scans based on your objectives.
  • Comprehensive data visualization: The intuitive software seamlessly integrates with the GeoSeeker, enabling real-time data visualization during scans. This allows you to monitor progress, identify anomalies, and make informed decisions on-site.
QUICK START GUIDE
GEOSEEKER
Messung eines einzelnen Punktes.
Measurement of a single point only.
Messung einer einzelnen Bahn (längs).
Scan of a single line (lengthwise).
Messung einer einzelnen Bahn (quer).
Scan of a single line (crosswise).
SCAN MODI SCAN MODES
SCAN PROFILE | SCAN PROFILES
Sehr detaillierte Messung Maximaler Zeitaufwand.
Very precise measurement – Most time consuming.
AKTIVE MESSUNG (Exakt)
ACTIVE SCAN (Accurate) Messung einer rechteckigen Fläche.
Measurement of a rectangular field.
VOLLSTÄNDIGE MESSUNG
COMPLETE MEASUREMENT
Schnelle Messung Limitierte Messfeldgröße und Messtiefe,
geringer Zeitaufwand.
Quick measurement – Less accurate and with limited depth and
dimensions, less time consuming.
AKTIVE MESSUNG (Schnell)
ACTIVE SCAN (Quick)
AKTIVE MESSUNG (Schnell)
Wird verwendet, wenn fließendes Wasser im Untergrund vermutet wird.
Empfohlen für sehr abschüssiges Gelände.
Useful if you expect floating water in the underground.
Recommended for very sloping terrain.
PASSIVE MESSUNG
PASSIVE SCAN
EINZELPUNKTMESSUNG
SINGLE MEASUREMENT
LÄNGSMESSUNG
LENGTHWISE MEASUREMENT
QUERMESSUNG
CROSSWISE MEASUREMENT
SCAN MODI SCAN MODES
SCAN MODI | SCAN MODES
SSID / Name: OKM_GeoSeeker
Password: GeoSeeker
Static IP: 192.168.143.42
Gateway: 192.168.143.1
DNS 1: 192.168.143.1
WLAN-Verbindung zwischen Tablet und Controller herstellen.
GeoSeeker App und Neue Messung starten. Projekttitel eingeben.
Connect Tablet and Controller via WLAN.
Start GeoSeeker App, New Measurement and enter a project title.
333
333
333
Tiefenbereich (Start und Ende), Messpunktabstand
und Messfeldgröße (Länge und Breite) festlegen.
Set the Depth Range (start and end depth), Resolution (distance
between the scan points) and Field Dimensions (length and width).
111
222
2
2
2
222
222
Scan Modus und Scan Profil wählen:
Wir empfehlen Aktive Messung (Exakt) und Vollständige Messung.
Choose Scan Mode and Scan Profile:
We recommend Active Scan (Accurate) and Complete Measurement.
444
444
444
↗ Messung vorbereiten
und den Anweisungen in der App folgen.
Prepare Scan
and follow the App instructions.
MESSUNG KONFIGURIEREN | CONFIGURE SCAN
MESSUNG KONFIGURIEREN
ACHTUNG! CAUTION!
Stromführende Teile
während der Messung
NICHT BERÜHREN!
DO NOT TOUCH
electrical components
during the measurement!
CONFIGURE SCAN
MESSUNG KONFIGURIEREN
444
444
444
444
SCAN FIELD SETUP
MESSFELD-AUFBAU | SCAN FIELD SETUP
MESSFELD-AUFBAU
MESSFELD-AUFBAU
|
SCAN FIELD SETUP
Messfeld vorbereiten:
Länge und Breite bestimmen
und Messpunkte setzen.
Prepare scan field:
Determine width and length
and set single scan points .
Messfeld vorbereiten:
111
Power Box und Controller am
ersten Messpunkt platzieren
und beide einschalten.
Place Power Box and
Controller at the first scan
point and switch on both.
Power Box und Controller am
222
GeoSeeker App starten und
↗ Messung konfigurieren:
Aktive Messung (Exakt).
Start GeoSeeker App
and ↗ Configure Scan:
Active Scan (Accurate).
GeoSeeker App starten und
333
Kabeltrommeln und Elektroden
für linke und rechte Seite
platzieren
↗ Messung vorbereiten
Prepare Scan for the left
and right side by placing
Cable Drums and Electrodes.
Kabeltrommeln und Elektroden
444
Akkus in Power Box und Controller
vor der Messung laden!
Charge Power Box and Controller
batteries before scanning!
1 m
SCAN FIELD SETUPMESSFELD-AUFBAU
Power Box am Messpunkt platzie-
ren, öffnen und Antenne ausklappen.
Place the Power Box at the current
scan point, open it and unfold antenna.
Strom-Elektroden an Markierung
platzieren, Kabeltrommel verbinden.
Place Power Electrodes and connect
with Cable Drum via Extension cable.
Strom-Kabeltrommeln verbinden
(rote Stecker/Buchsen).
Connect the Power Drums
(red plugs/sockets).
Controller mit 1 m Abstand zur
Power Box am Messpunkt platzieren.
Place the Controller at the scan point
1 m (3 ft) in front of the Power Box.
Power Box am Messpunkt platzie-
111
111
111
Strom-Kabeltrommeln verbinden
222
222
222
Strom-Kabeltrommeln bis zur an-
gezeigten Markierung (App) ausrollen.
Unroll Power Drums until you reach
the cable markers (see App).
Strom-Kabeltrommeln bis zur an-
333
333
333
Strom-Elektroden an Markierung
444
444
444
Kabelenden zurückführen bis zur
angezeigten Markierung (App).
Make a U-turn and return the
cable ends to its markers (see App).
Spannungs-Elektroden platzieren
und verbinden (schwarze Stecker).
Place and connect the Voltage
Electrodes (black plugs/sockets).
Spannungs-Kabeltrommeln
vollständig abrollen.
Unroll the Voltage Drum cables
completely.
Controller mit 1 m Abstand zur
555
555
555
Spannungs-Kabeltrommeln
666
666
666
Kabelenden zurückführen bis zur
777
777
777
Spannungs-Elektroden platzieren
888
888
888
MESSUNG VORBEREITEN | PREPARE SCAN
PREPARE SCANMESSUNG VORBEREITEN
Die Kabeltrommeln und Elektroden müssen jeweils links und rechts vom aktuellen Messpunkt platziert werden: APP-ANWEISUNGEN FOLGEN!
Place the Cable Drums and Electrodes left and right of the current scan point: FOLLOW APP INSTRUCTIONS!
PREPARE SCANMESSUNG VORBEREITEN
WWW.OKMDETECTORS.COM
OKM GmbH | Julius-Zinkeisen-Str. 7 | 04600 Altenburg | Germany
+49 3447 499 300 0 | info@okmdetectors.com
WEITERE INFOS & SUPPORT
FURTHER INFORMATION & SUPPORT
www.okmdetectors.com/downloads
HANDBUCH | USER MANUAL
SUPPORT
Bei weiteren Fragen wenden Sie sich bitte an
Ihren Händler oder direkt an OKM GmbH.
For further questions please contact your
dealer or directly OKM GmbH in Germany.
VIDEOS & TUTORIALS
www.okmdetectors.com/geoseeker-videos
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

OKM GeoSeeker User guide

Type
User guide

OKM GeoSeeker is an advanced 3D ground scanner with versatile applications in archaeology, geology, and civil engineering. With its cutting-edge technology, it offers a wide range of scanning modes and configurations, empowering you to tailor your surveys to specific needs.

  • Accurate and in-depth ground analysis: GeoSeeker employs active and passive scanning modes to provide highly detailed and precise measurements. Its variable depth range and resolution settings allow you to customize scans based on your objectives.
  • Comprehensive data visualization: The intuitive software seamlessly integrates with the GeoSeeker, enabling real-time data visualization during scans. This allows you to monitor progress, identify anomalies, and make informed decisions on-site.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI

in other languages