Cardinal Health Kangaroo Joey Enteral Feeding Pump User guide

Type
User guide

Cardinal Health Kangaroo Joey Enteral Feeding Pump is designed to provide precise and reliable enteral nutrition delivery to patients in a variety of care settings. With its advanced features, this pump offers flexibility and ease of use for both patients and caregivers:

  • Accurate feeding: Delivers nutrition at precise rates, ensuring consistent and controlled feeding.

  • Versatile feeding options: Accommodates a wide range of enteral feeding formulas and medications, meeting individual patient needs.

  • Easy to use: Intuitive controls and clear display simplify programming and monitoring, enhancing user-friendliness.

Cardinal Health Kangaroo Joey Enteral Feeding Pump is designed to provide precise and reliable enteral nutrition delivery to patients in a variety of care settings. With its advanced features, this pump offers flexibility and ease of use for both patients and caregivers:

  • Accurate feeding: Delivers nutrition at precise rates, ensuring consistent and controlled feeding.

  • Versatile feeding options: Accommodates a wide range of enteral feeding formulas and medications, meeting individual patient needs.

  • Easy to use: Intuitive controls and clear display simplify programming and monitoring, enhancing user-friendliness.

QUICK
REFERENCE
GUIDE
Do not use feeding sets for longer than 24 hours.
Kangaroo™ Joey enteral pump loading and feeding set rinsing
A. Distal end of feeding set
B. Feed only feeding set
C. Feed and ush feeding set
D. Pump
B C D
A
A
10. CAUTION — For proper accu-
racy, the uid level in the feed-
ing set bag must be 6 inches
above the top of the feeding
pump when the feeding cycle
is initiated.
4. Fill the feed bag with water to
approximately half of the total
capacity. Properly seal the bag
and shake for 5 to 10 seconds.
5. Empty the feed bag and repeat
the last step until the bag
contains clean water.
6. Power on the pump. Select
“Keep Settings” to continue
with previous setting or “Clear
Settings” to start programming
new pump settings.
Proper loading
and unloading
of feeding pump
1. Grasp thumb tab on valve and
insert into left pocket — ensure
valve is fully seated. Thumb tab
should align with slot in blue door.
2. Grasp black ring retainer, gently
wrap tubing around rotor and insert
retainer directly into right pocket.
Do not overstretch tubing.
3. To properly unload a pump set,
power off the pump and wait
10 seconds before removing
the feeding set.
8. Press and hold the “Hold to
Prime” button until only clean
water ows through the tubing.
Once the rotor starts this takes
between 1 and 2 minutes.
9. Empty bag of water. Prime to
remove any remaining water
from the feeding set.
7. Press the “Prime Pump button to
enter the “Prime Pump screen.
Proper rinsing
of feeding set
3. Empty contents of feed bag.
1. Disconnect feeding set from
patient before rinsing. The
feeding set must remain loaded
during the rinsing procedure.
2. CAUTION — If set is removed
from the pump while in
operation, it may damage the
set and prevent use, negatively
affecting the system accuracy.
15 Hampshire Street 800.962.9888
Mansfield, MA 02048 508.261.8000
© 2018 Cardinal Health. All Rights Reserved. CARDINAL HEALTH, the Cardinal Health LOGO and
Kangaroo are trademarks or registered trademarks of Cardinal Health and may be registered in the US
and/or in other countries. Patent www.cardinalhealth.com/patents. Lit. No. 2PATR18-764311 (10/2018)
For additional operations
and information, see the
Operating Manual for the
Kangaroo™ Joey Enteral
Feed and Flush Pump with
Pole Clamp, Programmable
  • Page 1 1
  • Page 2 2

Cardinal Health Kangaroo Joey Enteral Feeding Pump User guide

Type
User guide

Cardinal Health Kangaroo Joey Enteral Feeding Pump is designed to provide precise and reliable enteral nutrition delivery to patients in a variety of care settings. With its advanced features, this pump offers flexibility and ease of use for both patients and caregivers:

  • Accurate feeding: Delivers nutrition at precise rates, ensuring consistent and controlled feeding.

  • Versatile feeding options: Accommodates a wide range of enteral feeding formulas and medications, meeting individual patient needs.

  • Easy to use: Intuitive controls and clear display simplify programming and monitoring, enhancing user-friendliness.