Subject to changes | © 2017 SOLARWATT GmbH | AZ-TM-PME-0767 | Rev 008 | Version: 01/2017
Konguration EnergyManager Geräteinstallation Vorbereitung und Planung EN
1.4
The SOLARWATT MyReserve is a DC-coupled battery sto-
rage system installed between the photovoltaic system
and the inverter. There is no data exchange between
MyReserve and the inverter. With this DC connection,
MyReserve does not have a direct inuence on the net-
work quality. MyReserve can feed both single-phase and
three-phase inverters. Its AC Sensor records electrical po-
wer drawn from or fed into the public grid. These variab-
les are evaluated in order to determine the power output
of the battery storage. More or less power is transferred to
the inverter depending on household consumption.
As such, when the system is running entirely in battery
mode (at night), rather than feeding electrical energy into
the grid, the MyReserve will regulate the system so as to
maximize consumption of self-generated electricity. Du-
ring the day, the MyReserve will output battery power in
such a way that the system draws as little energy from the
public grid as possible, and draws in enough power to en-
sure that the battery is charged completely by sundown.
This charging and discharging behavior protects the lit-
hium ion cells and maximizes the service life of the My-
Reserve.
1.5
AC Alternating Current
DC Direct Current
ACS SOLARWATT AC Sensor 50 / AC Sensor 63
CAN Controller Area Network
PSC Power supply company
Com. Communication
LED Light-Emitting Diode
PV Photovoltaic
Battery module SOLARWATT MR Pack 2.2
1.6
The MyReserve is designed exclusively for storing electri-
cal energy generated by PV systems, and should be used
for this purpose alone. All technical data must be obser-
ved. Using the MyReserve improperly or for purposes
other than the intended one can result in product mal-
functions and/or life-threatening situations. and renders
the warranty null and void.
1.7
• Do not connect MyReserve to electrical systems that
have a building connection greater than 40 A per phase
(AC Sensor 50) or 63 A per phase (AC Sensor 63)
• Do not use MyReserve in vehicles (motor vehicles,
aircraft or ships)
• Do not use MyReserve as an uninterruptible power
supply (UPS)
• Do not connect MyReserve to PV systems in which
the negative pole and/or positive pole is grounded
• Do not use MyReserve for the operation of medical
equipment
• Do not use MyReserve to operate devices for which
functional safety must be guaranteed
• Do not use MyReserve in areas which are prone to
explosion (our dust, saw dust, etc.)
• Do not expose MyReserve to direct sunlight