PELHAM & WHITE PW82079-W Installation guide

Type
Installation guide
Owner’s Manual & Installation Guide
Contemporary Tubs
Tub Filler Faucets
Note: Read all instructions before proceeding with installation. All specifications are
subject to change without notice.
2
Giagni
Warranty
Pelham & White warrants, to the initial consumer purchaser, the surfaces of the bathtub and acrylic plinths to be free of defects in material and
workmanship during normal residential use for a period of 25 years from the date of purchase. This warranty does not cover normal wear and
tear or damage to the surface caused by the use of chemicals that break the structural bonds in the acrylic material (see cleaning & maintenance
page). Damage caused by accident, misuse, or abuse is not covered by this warranty.
If any defects develop under the warranty from the date of purchase, we will, at our discretion, consider repairing or replacing the defective
part(s). Improper use or installation will immediately void the warranty. No other liability or obligation is to be assumed. Proof of purchase (original
sales receipt) must be provided to Pelham & White with all warranty claims. Pelham & White will not be responsible for labor charges and installation
or any other consequential costs. In no event shall the responsibility of Pelham & White exceed the purchase price of the product.
Faucets
Pelham & White faucets come with a limited lifetime warranty. The warranty applies to defects in workmanship and finish. The above warranty does not
apply to damages resulting from shipping, misuse, tampering, abuse or ordinary wear and tear. Warranty for finish is void if proper care is not
demonstrated.
Drains, Feet, Plinths, & Cradles
Pelham & White drains, feet, plinths, cradles, and components are guaranteed to be free from defects in material, workmanship, and finish at the time of
shipment. Should any defects develop within 5 years from the date of purchase, we will, at our discretion, consider repairing or replacing the
defective part(s).
This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. Some states do not allow the
exclusions of limitations of incidental or consequential damages, so the above limitations or exclusions may not apply to you. For warranty claims
or questions, contact Pelham & White at (855)-561-5222.
In event of a defect
In the event of a defect covered by the limited warranties contained herein, you must notify your authorized Pelham & White representative within 30 days
after the date of the occurrence of the defect, and such representative will repair or otherwise correct the defect within a reasonable time in
accordance with and after subject to the terms and conditions set forth herein. Pelham & White shall not be liable for (a) the cost of shipping or otherwise
transporting parts and materials necessary to correct any defect and (b) any direct, indirect, incidental or consequential damages, (c) all tubs are
thoroughly inspected for defects prior to shipment and a follow up inspection is required after receiving the tub. Thus, the Pelham & White warranty will not
cover the cost associated with the removal and reinstallation of a defective bathtub.
Non-Transferrable
The limited warranties contained herein are not transferable or enforceable by any party other than the original purchases (user).
Transportation & Delivery
The limited warranties contained herein shall not apply to damage or any problem caused by improper handling of the tub to the purchaser or any
subsequent movement of the tub by the purchaser. Purchaser is responsible for all warranty related freight charges.
Property Damage
The limited warranties contained herein shall not cover property damage due to water. The responsibility of water damage is solely that of the
installer or owner as we recommend a pre-install water test in our installation section.
Disclaimer
Authorized Pelham & White representatives are not agents of Pelham & White, and no agent, dealer, or representative, salesperson or other person
is authorized to change, modify, expand or extend the limited warranties contained herein, or to bind Pelham & White or any of its authorized representatives
to be held for injury or damage to any person or property for any claim, regardless of manner in which claims arise.
All measurements are approximations and should be used for reference only. Pelham & White reserves the right to make specification changes without
notice or obligation, and to change or discontinue models and finishes. All rights reserved. © Pelham & White 2023
3
Before you begin:
Observe all local plumbing/building codes and ensure flooring support is adequate. Installation of
backflow prevention must comply with local codes and regulations. In certain states models with
handshower must be installed with a listed inline anti-scald device.
Before you begin work, carefully uncrate and inspect the tub for any damage. If there is a
problem, do not install the tub. Immediately report the problem to the dealer.
Ensure the floor will support 1200 lbs. (This is the approximate weight of the tub filled with water
and bather.)
Carefully plan the moving of the bath into the installation area. These bathtubs may not easily fit
through doorways.
Before installation, ensure proper access to the final plumbing connections.
Safety instructions:
To reduce the risk of injury:
Do not permit children to use this unit unless they are closely supervised by an adult at all times.
Supervision is also required when the bath is used by an elderly or handicapped individual.
Use this unit only for its intended use as described in this manual. Do not use attachments not
recommended by the manufacturer.
Since excessive water temperatures have a high potential for causing fetal damage during
the early months of pregnancy, pregnant or possibly pregnant women should limit bath water
temperatures to 38° C (100° F).
The use of drugs or alcoholic beverages before or during bath use may lead to unconsciousness
with the possibility of drowning.
Persons with a medical history of heart disease, low or high blood pressure, circulatory system
problems, or diabetes should consult a physician before using the bath.
Persons using medication should consult a physician before using the bath since medication may
induce drowsiness while other medication may affect heart rate, blood pressure and circulation.
DANGER: To reduce the risk of injury, enter and exit the bath slowly.
WARNING: Never operate electrical devices in or near the bath. Never drop or insert any object into
any opening within the bath.
To avoid the possibility of personal injury and discoloration of the acrylic surface, the inlet water
temperature should not exceed 60° C (140° F) and the bath should be drained after each use.
FREESTANDING TUB INSTALLATION
4
Assemble bath on a mat to protect
against damage to bath surface.
Ensure legs are adjusted in line with the base
of bath.
Check that bath sits flat; if required
adjust legs to compensate for floor level.
Place tub in desired location, being sure to
accommodate any plumbing needed for the
faucet and drain. Mark the perimeter of the
tub with a pencil or painter’s tape.
1
3
2
FREESTANDING TUB INSTALLATION SUPPLEMENT
5
Install the Brass Tub Drain to the tub. Make the necessary alterations to the floor to accommodate
the tub drain and drain pipe, and enable the drain pipe to be connected to the drainage system as
required by local code.
4
Use appropriate silicone for surface
type.
Apply a thick bead of silicone within bath
outline.
Place tub back in the desired position,
carefully pressing downward to allow the
tub feet to contact the floor and the silicone
to seal the low spots. Clean up the silicone
bead.
Do not touch or ll the tub for 24 hours to let
the silicone fully cure.
5 6
Make the nal connections from the tub drain pipe to the home’s drainage system
per local code.
7
STEP 5
INSTALLING THE FAUCET
There are three styles and two faucet mounting methods.
Please refer to the appropriate page for your application.
FLOOR MOUNT
see page 7
SINGLE-POST TUBE
see page 11
SINGLE-POST SQUARE
see page 11
WALL MOUNT
see page 9
CONTEMPORARY STYLE
SINGLE-POST FILLER STYLE
6
7
CONTEMPORARY FLOOR MOUNT TUB FAUCET
3
7
(Allen Wrench)
1
Step 1- Install #1 spout into
faucet body by pushing straight
down. Align spout facing forward
then tighten with #3 allen screw
(packaged separately with #7 allen
wrench). Do Not Over Tighten.
Step 3- Attach hot and cold risers
C-FRSR to union nuts on back of
faucet body using one #10 rubber
gasket on each riser.
Step 2- Screw #16 handle hub
onto hot/cold cartridges #9 & #17.
Disassemble handle by unscrewing
spokes and install onto cartridge
by securing with screw included.
Reassemble handle.
1
10
C-FRSR
Union Nut
C-HLVR
17
9C-HCRS
16
16
Screw
Spokes
Spokes
Tub
Drain
Washer
C-FB1
C-FRSR
Floor Flange (26)
MIN. 3-3/4"
MAX. 5-1/2"
Decorative
Escutcheon (25)
C-FRSR
Step 4- Drill (2) 1-1/8 holes into floor on 8
centers for hot and cold water supplies (see
fig. 5 next page). Supply holes should be
drilled at 3 ¾ minimum to 5 ½ maximum
from drain outlet (center to center).
Step 5- Slide #25 decorative escutcheon onto
bottom of risers C-FRSR and push part way
up. Screw #26 floor flange onto threaded
portion of each riser until it stops.
Step 6- Insert risers into hole in floor and
secure floor flanges with appropriate screws/
bolts for your flooring type. (Hardware not
included)
Notes:
1. Faucet is not for use on concrete floors.
2. Please ensure all local plumbing codes are observed during installation
3. Water supply lines must be roughed in on 8” centers.
8
CONTEMPORARY FLOOR MOUNT TUB FAUCET (cont.)
Step 9- Attach small end of #18 handshower
hose with #30 washer to outlet below diverter
faucet handle.
Step 10- Attach large end of #18 hand shower
hose to #16 handshower with #30 washer and
place in holder.
Step 11- Connect preferred ½” pipe (supplied by
installer) into female threaded riser C-FRSR from
under flooring. Make hot/cold water connections.
Turn on water and check all connections for leaks.
16
18
30
30
FIGURE 5 Supply line spacing
8"
Step 7- Slide #25 decorative escutcheon down
to cover floor flange.
Step 8- Tighten optional support bracket to
risers and drain
9
CONTEMPORARY WALL MOUNT TUB FAUCET
3
7
(Allen Wrench)
1
Step 1- Install #1 spout into faucet
body by pushing straight down. Align
spout facing forward then tighten with
#3 allen screw (packaged separately
with #7 allen wrench). Do Not Over
Tighten.
Step 2- Screw #16 handle hub
onto hot/cold cartridges #9 & #17.
Disassemble handle by unscrewing
spokes and install onto cartridge
by securing with screw included.
Reassemble handle.
C-HLVR
17
9C-HCRS
16
16
Screw
Spokes
Spokes
Notes:
1. Please ensure all local plumbing and building codes are observed when installing
these faucets.
2. Mounting location depends on tub design and location. Be sure to identify tub height
when determining faucet location.
3. There must be a minimum of 2" gap between top of tub rim and bottom of the faucet
spout to comply with plumbing codes.
4. Water supply lines must be roughed in on 8” centers.
10
CONTEMPORARY WALL MOUNT TUB FAUCET (cont.)
Step 6- Attach small end of #18 handshower
hose with #30 washer to outlet below diverter
faucet handle.
Step 7- Attach large end of #18 hand shower
hose to #16 handshower with #30 washer
and place in holder.
Step 8- Turn on water and check all
connections for leaks.
16
18
30
30
Finished Wall
Decorative
Flange (28)
Pipe Nipple
C-WLBO (29)
3/8"-1/2"
Washer (10)
C-FB1
Union Nut
Step 3: Rough-in #29 C-WLBO
flush to finished wall. Hot/Cold
supplies should be roughed
in on 8” centers and 1/2” pipe
should extend 3/8” to 1/2
beyond the finished wall.
Step 4: Screw #28 decorative
flange included with C-WLBO
onto rough portion of #29.
Step 5: Attach faucet to wall by
screwing the union nuts onto the
C-WLBO wall elbows with #10
washers.
Finished Wall
Decorative
Flange
Pipe Nipple
TPN 41 - 2/1
SINGLE CONTROL FREESTANDING TUB FILLER
INSTALLATION GUIDE
Note:
Carefully read this entire installation guide before installing and using this product.
Parts Identication
1. Spout
2. Aerator
3. Faucet Body
4. Diverter Button
5. Main Tube
6. Floor Escutcheon
7. Supply Hoses (2)
8. Floor Bracket
9. Handshower
10. Handshower Hose
MODELS:
PW82424
PW82425
PW82426
MODELS:
PW82427
PW82428
PW82429
11
2
345
SINGLE CONTROL FREESTANDING TUB FILLER (CONT.)
FAUCET ASSEMBLY
1
Slide the Floor Escutcheon (6) over the
externally threaded end of the Main
Tube (5) as shown.
Screw the Main Tube (5) onto the Floor
Bracket (8). Hand-tighten as firmly as
possible.
Feed the Supply Hoses (7)
up through the Main Tube
(5) as shown.
Thread the HOT supply hose all
the way into the threaded hole
in the bottom of the faucet body
nearest the hand spray holder,
and the COLD supply hose in
the far hole. The connections
on the Faucet Body are also
marked H and C. Hand tighten
or apply light torque with pliers.
No need to overtighten.
Connect main tube to faucet body
ROUND BODIES: Screw the Main
Tube (5) onto the Faucet Body (3)
and tighten firmly by hand.
SQUARE BODIES: Slide the Faucet
Body (3) fully into the end of Main
Tube (5) that has the two setscrews.
Orient the faces of the two pieces so
that the two setscrews are directed to-
ward where the faucet will be viewed
the least. Secure by tightening the
two setscrews. Do not over-tighten.
12
SINGLE CONTROL FREESTANDING TUB FILLER (CONT.)
MOUNTING FAUCET TO FLOOR
Due to the various materials and conditions that may exist surrounding this installation, it will be the responsibility of
the installer to select the location of the faucet, the appropriate fasteners to secure the faucet to the oor, and the
roughing-in of the supply piping.
Be sure to orient the faucet so that the spout is in the correct direction and at the location that will enable the
spout to ow water into the tub without hitting the rim of the tub.
6
9
12 13
7
10
8
11
Orient the faucet in correct posi-
tion in relation to the tub.
Secure the Floor Bracket (8) to
the oor using the appropriate
fasteners.
Unscrew and remove the Aerator
(2) at the end of the spout.Turn
the faucet o.
Place Handshower Hose (10) in
an empty bucket and secure.
Re-install the aerator at the
end of the spout. Be sure
the black rubber washer is
in place. Hand-tighten rmly.
Slide the Floor Escutcheon (4)
down to the oor and seal with
silicone caulk.
Connect the Supply Hoses (7)
to the roughed-in hot and cold
piping. Be sure the black rubber
washers are in place. The thread
on the hose swivel nuts is ½ x
14TPI.
TEST & FLUSH
LINES
Turn on the water supplies.
Check for leaks.
Turn the faucet on (hot and
cold) and ush the lines of
debris.
Hold the Handshower
Hose in a bucket, push the
diverter button and ush
that line.
Connect the Handshower Hose
(10) to the Faucet Body (3). Be
sure the black rubber washer is
in place. Hand-tighten as rmly
as possible. Do not connect the
Handspray yet.
Connect the Handshower Hose
(8) to the Handshower (7).
Be sure the black rubber washer
is in place. Hand-tighten rmly.
13
CLEANING & MAINTAINING YOUR BATHTUB
Cleaning:
 


 
 
   

  

 

NOTE:   
  
 




®  
@  
14
Contact information
Pelham & White
548 South Columbus Avenue
Mount Vernon, New York 10550
Phone: 855-561-5222
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15

PELHAM & WHITE PW82079-W Installation guide

Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI