#8-32 x 3/4"
with Gasket
Socket Head Cap (9/64" Hex)
Machine Screw (6x)
(Hex Key/Bit Not Included)
#8-32 x 3/8"
Flat Head Phillips
Machine Screw (4x)
Part of
Dome Kit
Part of Dome Kit
Dome Kit
#8 Washer (6x)
Part of
Dome Kit
Part of Dome Kit
Dome Kit
Auxiliary Strobe
Mounting Screw (3x)
#8 x 5/16" Pan Head Phillips
SEMs Machine Screw
Network Connector Here
Three (3) Provided
Adapter Plate
Conduit (Not Shown &
Backbox
Clear Cover
Auxiliary Strobe
3/4" NPT Hub
Part of
Dome Kit
Not Provided)
Rotate Backplate and/or
Dome Kit Adapter Plate for
Desired Conduit Mounting Directions
Keyed Edge
Only three (3) screws are being
Remote Strobe Cable
Part of
Auxiliary Strobe
used. Make sure that the mount
is located correctly or interference
will occur.
Part of
Auxiliary Strobe
3
for Alignment
Keyed Edge
for Alignment
(J1)
Mounting Holes
7
7
7
1 & 5
2
6
2
2
Backplate
2
4
2
Not Used
1. Remove the backplate from the VoIP Strobe
by removing the three Mounting Screws.
See the section called, "Removing the
Auxiliary Strobe Backplate to Install the
Dome Kit" on the front page.
2. Install the Backplate to the Dome Kit
Adapter Plate with the three
#8 x 5/16-inch Pan-Head Phillips
Machine Screws.
Note Only three screws are being
used. Make sure that the mount
is located correctly or interference
will occur.
3. Install the Dome Kit Backbox onto
the wall with the Wall Mounting Kit.
4. Run the network cable (not provided)
through the conduit (not provided), NPT
Hub, Adapter Plate, and then through the
Backplate into the network
connector (J1).
5. Secure the Backplate with
the three Mounting Screws
that were removed in Step 1.
6. Secure the Adapter Plate with
the Flat-Head Machine Screws.
7. Install the Clear Cover
with the Socket Head Cap
Screws and Washers.