  • Hello! I am an AI chatbot trained to assist you with the Vicks Fever InSight Thermometer Operating instructions. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Fever InSight
®
Thermometer
Model V916C-AUS
* Uses CR1225 or equivalent battery
READ AND KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE
Thank you for purchasing the Vicks® Fever InSight® Thermometer with large screen display and Fever InSight® feature, a professional accurate instrument for faster and
easier temperature taking. Please read these instructions carefully to ensure accurate temperature measurements and safe operation. When used properly, this high
quality product will give you years of accurate, dependable service.
IMPORTANT SAFETY INFORMATION
• High,prolongedfeverrequiresmedicalattentionespeciallyforyoungchildren.Pleasecontactyourphysician.
• Donotallowchildrentotaketheirtemperaturesunattended.
• Donotallowchildrentowalkorrunduringtemperaturetaking.
• Thethermometerisonlysuitableforthemeasurementofbodytemperature.Theuseofthisthermometerisnotintendedasasubstitutefor
 consultationwithyourdoctor.
• Thethermometerisinitiallycalibratedatthetimeofmanufacture.Ifthisthermometerisusedaccordingtotheuseinstructions,the
 accuracyofmeasurementswillnotbeaffected.
TEMPERATURE READINGS
Temperaturereadingsvaryfrompersontoperson.Althoughthereisnoone“normal”temperaturereading,atemperature,takenorally,
rangingbetween36.1°C/97°Fand37.7°C/100°Fisconsiderednormal.Arectaltemperatureisgenerally0.5°C/1°Fhigherandanunderarm
(axillary)temperaturewillbe0.5°C/1°Flower.
Thebestmethodtodetermineyourownnormaltemperatureistousethethermometerwhenyouarefeelingwell.Recordyourreadingtwice
aday(earlymorningandlateafternoon).Taketheaverageofthetwotemperatures.Thisisconsideredyournormalbodytemperature.Any
variationfromitmayindicatesomesortofillnessandyoushouldconsultyourphysician.
BEFORE USE
YourVicks
®
FeverInSight
®
Thermometerisa3-in-1thermometerfororal,rectal,orunderarmuse.Whichevermethodisused,it
isrecommendedthatfor15minutespriortouse,youavoideatingordrinking,exercising,takingshowersorbathsorsmoking.
OPERATING YOUR VICKS
®
FEVER INSIGHT
®
THERMOMETER
1. TURNING THE THERMOMETER ON
 • TurnthermometeronbypressingtheOn/Offbutton(Fig. 1).
 • AbeepsignalwillsoundandthedisplaywillashRed/Yellow/Greenfor1second.
 • Waitforthethermometertogetready
  –Thedisplaywillshowatestvalue(Fig. 2).
  –Thedisplaywillshowlastmeasurementfor2seconds (Fig. 3).
  –Afterabout5seconds,thedisplaywillshowit’sready(Fig. 4).
2. SELECTING WHERE TO TAKE THE TEMPERATURE
Oral Use
• Itisimportanttoplacethetipofthethermometerwellunderthetonguetogetagood,accurate
reading.(Fig. 5) Placesensortipinareasmarkedwith“4”.
Keepmouthclosedandsitstilltohelpensureanaccuratemeasurement.
 • Whenthepeaktemperatureisreached(usuallywithin12seconds),5beepsignalswillsound
andthe“°C/°F”signwillstopashing.Thetemperaturemeasurementisnowreadytoreadand
willnotchangewhenthethermometerisremoved.
 • Washthethermometerasrecommended
Under-the-arm (Axillary) Use
 Thismethodcanbeusedforbabiesandyoungchildren.
 • Wipetheunderarmwithatowel.
•
Placetheprobetipunderthearmsothetipistouchingtheskinandpositionthearmnexttothebody(Fig. 6).
  Withayoungchild,itissometimeshelpfultohugthechildtokeeptheirarmnexttotheirbody.
  Thisensuresthattheroomairdoesnotaffectthereading.
 • Whenthepeaktemperatureisreached(usuallywithin11secondsbutsometimeslongerforthis
method),5beepsignalswillsoundandthe“°C/°F”signwillstopashing.Thetemperature
measurementisnowreadytoreadandwillnotchangewhenthethermometerisremoved.
Note: This method produces a temperature reading 0.5°C / 1°F lower than if the temperature were
taken orally.
 • Washthethermometerasrecommended.
Rectal Use
 Commonlyusedforbabies,youngchildren,orwhenitisdifculttotakeanoralorunderarmtemperature.
 • Laythepatientonhis/herside.Forababy,theproperpositionistolayonitsstomachwithlegshanging
down,eitheracrossyourkneesorattheedgeofabedorchangingtable.Thispositionstheinfant’s
rectumforsafeandeasyinsertionofthethermometer.
 • GentlyinsertthetipofthethermometerNOMORETHAN1cmintotherectum.Ifyoudetectresistance,
stop.Holdthethermometerinplaceduringmeasurement.
 • Whenthepeaktemperatureisreached(usuallywithin10seconds)5beepsignalswillsoundandthe
“°C/°F”signwillstopashing.Thetemperaturemeasurementisnowreadytoreadandwillnotchange
whenthethermometerisremoved.
NOTE: This method produces a temperature reading 0.5°C / 1°F higher than if the temperature were
taken orally.
 • Washthethermometerasrecommended.
3. READING THE MEASUREMENT: FEVER INSIGHT
®
FEATURE
 TheVicks
®
FeverInSight
®
Thermometercomeswiththepatented“FeverInSight
®
”featurewhichoffersacolorindicator
 withthetemperaturereading.Thisfeaturewillhelpyouexplaintoyourchildthemeaningoftemperature.Italsohelps
 bydistractingyourchildfrompossiblefearassociatedwithtemperaturetaking,especiallywithyoungchildren.
 • Forreadingsbetween36.1-37.1°C/97-98.8°F,thescreenwilldisplaygreenasthebacklightcolorindicatingthetemperatureis
  withinthe“normal”range.
 • Forreadingsbetween37.2-38.2°C/99-100.7°F,thescreenwilldisplayyellowasthebacklightcolorindicatingaslightelevation
  intemperature.
 • Forreadings38.3°C/101°Fandabove,thescreenwilldisplayredasthebacklightcolorindicatingpossiblefever.
 TheFeverInSight
®
featurecontinuesforabout5seconds.
4. TURNING THE THERMOMETER OFF
 TurnthethermometeroffbypressingtheOn/Offbutton.Ifyouforgettoturnitoff,thethermometerwillautomaticallyturnoffafter
 approximately11/2minutes.
CHANGING TEMPERATURE SCALE FROM °C TO °F OR °F TO °C
Whenthepowerisoff,pressandholdtheOn/Offbuttonfor4seconds,whenthe“M”symboldisappears,releasethebuttonandpressthe
buttontoswitchfrom°Cto°For°Fto°C.After3secondsidle,thethermometerentersintotheready-for-measurementmode.
CLEANING INSTRUCTIONS
• Cleanthethermometerbywashingitwithsoapandwarmwaterorrubbingalcohol(70%isopropylalcohol).
• Wipedrywithsoftcloth.
• DONOTBOILORWASHINDISHWASHER.Thiswillcausethethermometertonolongerfunctionandwillvoidthewarranty.
• Donotwashwithanythinnerorchemicalsolvent.
SPECIFICATION
Type: DigitalThermometer(Predictive)
BatteryLife: morethan300measurementsorapproximately2yearsifusedeveryotherday.
Accuracyinwaterbath: +/-0.1°Cbetween35.5-41.6°Catroomtemperatureof21.6°C.
+/-0.2°Fbetween96.0-107°Fatroomtemperatureof71°F
TemperatureRange: 32.0-42.9°C.Iflessthan32.0°C“Lo”isdisplayed.Ifmorethan42.9°C“Hi”isdisplayed.
89.6-109.9°F.Iflessthan89.6°F“Lo”isdisplayed.Ifmorethan109.9°F“Hi”isdisplayed.
OperatingTemperature: +10°Cto+40°C(50°F-104°F),15%to95%RH
StorageTemperature: –25°Cto+60°C(-13°F-140°F),15%to95%RH
Ifthedeviceisnotusedwithinspeciedtemperatureandhumidityrangesthetechnicalaccuracyofthe
measurementcannotbeguaranteed.
Beeper: Thethermometerwillbeepforapproximately8secondswhenpeaktemperatureisreached.
Fortemperaturesover38.3°C/101°F,theaudibleFeverAlertwillsound5times.
ErrorMessages: Thedisplaywillread“Err”whenamalfunctionoccursandthethermometerwillpoweroff.
•EN12470-3 •ASTME1112
•IEC60601-1 •IEC60601-1-2
TEST PROTOCOL
(Laboratory use only)
1. Placethermometerintoastableliquidbathwithtemperaturesetabove35°C(95°F).Thetipofthethermometershouldbe
approximately0.8inches(2cm)belowthesurface.
2. Waitfor10seconds,thenturnthermometeronbypressingtheblue“On/Off”button.
3. Whenthemeasurementiscompleted(approximately8seconds),recordthetemperaturereading.
CHANGING THE BATTERIES
TheVicks
®
FeverInSight
®
Thermometerfeaturesalonglifebattery.Whenthe“
”appearsandashesinthecentertopofthedisplay,the
batteryisexhaustedandneedsreplacing.
1.Usingacoin,unlockthebatterycoverandcarefullyremovethebatterywithanon-metallicinstrument.
2.Replacethebatterywitha3V,CR1225lithiumtypeorequivalent.Insertthenewbatterywiththepositive(+)sidefacingthebatterycover.
3.Carefullyputthebatterycoverbackinplaceand,usingacoin,tightenthecover.
4.Properlydisposeoftheoldbattery.Keepoutofreachofyoungchildren,elderlyandpets.
LIFETIME WARRANTY
Thisproducthasbeenproducedwiththegreatestcarefornormal,householduse.Followingdirectionscarefullywillensuredependableoperation.Iffor
anyreason(otherthanmisuseornormalbatteryoperation)youaredissatisedwithyourVicks
®
FeverInSight
®
Thermometer,wewillrepairorreplaceit,
atouroption,atnochargeduringthelifetimewarrantyperiod.Modicationtotheproductbytheconsumerisnotauthorisedandvoidsthewarranty.
Ifthethermometerdoesnotfunctionproperly,rstcheckthebattery.Replaceifnecessary.Batteriesandpackagingareexcludedfromthewarranty.
Ifyouexperienceunsatisfactoryoperation,pleasecontactFeltonGrimwade&Bosisto’s.Ifrepairisrequiredunderthewarrantyperiod,theproduct
shouldbereturnedwithproofofpurchasetoFeltonGrimwade&Bosisto’sservicecentre.
Thepurchaserassumesresponsibilityforthepropercareanduseoftheproductinaccordancewiththeprintedoperatingmanual.Thepurchaseror
usermustmakehisorherjudgmentastowhentousetheproductandthelengthofuse.Keeptheoperationmanualavailableasitisyourguidetosafe,
efcientoperation.
OurgoodscomewithguaranteesthatcannotbeexcludedundertheAustralianConsumerLaw.Youareentitledtoareplacementorrefundforamajor
failureandforcompensationforanyotherreasonablyforeseeablelossordamage.Youarealsoentitledtohavethegoodsrepairedorreplacedifthe
goodsfailtobeofacceptablequalityandthefailuredoesnotamounttoamajorfailure.
Probe Tip
On/O Button
Large Display with
Fever InSight® backlight
Battery
Compartment
(on back side)
Important: Before first use,
remove label from the display.
Fig. 1
Fig. 2
Fig. 3 Fig. 4
Fig.5
Fig.6
P/N:31IMV916191 DATE:05SEP12
Distributedby:FeltonGrimwade&Bosisto’sPty.Ltd.
61-81ClarindaRoad(PoBox74),OakleighSouth,
Victoria3167,Australia
Freecall:1800655841 E-mail:[email protected]
Website:www.fgb.com.au
BFTypeappliedpart.  ConsultInstructionsforUse
ThestipulationsofEU-Directive93/42/EECfor
MedicalDevicesClassIIahavebeenfullled.
0044
Manufacturing Quality Healthcare Products for Over 75 Years
ThisproductismanufacturedbyKazUSA,Inc.underlicensefromTheProcter
&GambleCompany.VicksandotherassociatedtrademarksareownedbyThe
Procter&GambleCompany. ©2012KazUSA,Inc. Allrightsreserved.
MadeandprintedinChina www.kaz.com/vicks
Pleasedonotdisposeoftheproductanditsbatteriesinthe
householdwasteattheendofitsusefullife.
/