Fever InSight
®
Thermometer
Model V916C-AUS
* Uses CR1225 or equivalent battery
READ AND KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE
Thank you for purchasing the Vicks® Fever InSight® Thermometer with large screen display and Fever InSight® feature, a professional accurate instrument for faster and
easier temperature taking. Please read these instructions carefully to ensure accurate temperature measurements and safe operation. When used properly, this high
quality product will give you years of accurate, dependable service.
IMPORTANT SAFETY INFORMATION
• High,prolongedfeverrequiresmedicalattentionespeciallyforyoungchildren.Pleasecontactyourphysician.
• Donotallowchildrentotaketheirtemperaturesunattended.
• Donotallowchildrentowalkorrunduringtemperaturetaking.
• Thethermometerisonlysuitableforthemeasurementofbodytemperature.Theuseofthisthermometerisnotintendedasasubstitutefor
consultationwithyourdoctor.
• Thethermometerisinitiallycalibratedatthetimeofmanufacture.Ifthisthermometerisusedaccordingtotheuseinstructions,the
accuracyofmeasurementswillnotbeaffected.
TEMPERATURE READINGS
Temperaturereadingsvaryfrompersontoperson.Althoughthereisnoone“normal”temperaturereading,atemperature,takenorally,
rangingbetween36.1°C/97°Fand37.7°C/100°Fisconsiderednormal.Arectaltemperatureisgenerally0.5°C/1°Fhigherandanunderarm
(axillary)temperaturewillbe0.5°C/1°Flower.
Thebestmethodtodetermineyourownnormaltemperatureistousethethermometerwhenyouarefeelingwell.Recordyourreadingtwice
aday(earlymorningandlateafternoon).Taketheaverageofthetwotemperatures.Thisisconsideredyournormalbodytemperature.Any
variationfromitmayindicatesomesortofillnessandyoushouldconsultyourphysician.
BEFORE USE
YourVicks
®
FeverInSight
®
Thermometerisa3-in-1thermometerfororal,rectal,orunderarmuse.Whichevermethodisused,it
isrecommendedthatfor15minutespriortouse,youavoideatingordrinking,exercising,takingshowersorbathsorsmoking.
OPERATING YOUR VICKS
®
FEVER INSIGHT
®
THERMOMETER
1. TURNING THE THERMOMETER ON
• TurnthermometeronbypressingtheOn/Offbutton(Fig. 1).
• AbeepsignalwillsoundandthedisplaywillashRed/Yellow/Greenfor1second.
• Waitforthethermometertogetready
–Thedisplaywillshowatestvalue(Fig. 2).
–Thedisplaywillshowlastmeasurementfor2seconds (Fig. 3).
–Afterabout5seconds,thedisplaywillshowit’sready(Fig. 4).
2. SELECTING WHERE TO TAKE THE TEMPERATURE
Oral Use
• Itisimportanttoplacethetipofthethermometerwellunderthetonguetogetagood,accurate
reading.(Fig. 5) Placesensortipinareasmarkedwith“4”.
Keepmouthclosedandsitstilltohelpensureanaccuratemeasurement.
• Whenthepeaktemperatureisreached(usuallywithin12seconds),5beepsignalswillsound
andthe“°C/°F”signwillstopashing.Thetemperaturemeasurementisnowreadytoreadand
willnotchangewhenthethermometerisremoved.
• Washthethermometerasrecommended
Under-the-arm (Axillary) Use
Thismethodcanbeusedforbabiesandyoungchildren.
• Wipetheunderarmwithatowel.
•
Placetheprobetipunderthearmsothetipistouchingtheskinandpositionthearmnexttothebody(Fig. 6).
Withayoungchild,itissometimeshelpfultohugthechildtokeeptheirarmnexttotheirbody.
Thisensuresthattheroomairdoesnotaffectthereading.
• Whenthepeaktemperatureisreached(usuallywithin11secondsbutsometimeslongerforthis
method),5beepsignalswillsoundandthe“°C/°F”signwillstopashing.Thetemperature
measurementisnowreadytoreadandwillnotchangewhenthethermometerisremoved.
Note: This method produces a temperature reading 0.5°C / 1°F lower than if the temperature were
taken orally.
• Washthethermometerasrecommended.
Rectal Use
Commonlyusedforbabies,youngchildren,orwhenitisdifculttotakeanoralorunderarmtemperature.
• Laythepatientonhis/herside.Forababy,theproperpositionistolayonitsstomachwithlegshanging
down,eitheracrossyourkneesorattheedgeofabedorchangingtable.Thispositionstheinfant’s
rectumforsafeandeasyinsertionofthethermometer.
• GentlyinsertthetipofthethermometerNOMORETHAN1cmintotherectum.Ifyoudetectresistance,
stop.Holdthethermometerinplaceduringmeasurement.
• Whenthepeaktemperatureisreached(usuallywithin10seconds)5beepsignalswillsoundandthe
“°C/°F”signwillstopashing.Thetemperaturemeasurementisnowreadytoreadandwillnotchange
whenthethermometerisremoved.
NOTE: This method produces a temperature reading 0.5°C / 1°F higher than if the temperature were
taken orally.
• Washthethermometerasrecommended.
3. READING THE MEASUREMENT: FEVER INSIGHT
®
FEATURE
TheVicks
®
FeverInSight
®
Thermometercomeswiththepatented“FeverInSight
®
”featurewhichoffersacolorindicator
withthetemperaturereading.Thisfeaturewillhelpyouexplaintoyourchildthemeaningoftemperature.Italsohelps
bydistractingyourchildfrompossiblefearassociatedwithtemperaturetaking,especiallywithyoungchildren.
• Forreadingsbetween36.1-37.1°C/97-98.8°F,thescreenwilldisplaygreenasthebacklightcolorindicatingthetemperatureis
withinthe“normal”range.
• Forreadingsbetween37.2-38.2°C/99-100.7°F,thescreenwilldisplayyellowasthebacklightcolorindicatingaslightelevation
intemperature.
• Forreadings38.3°C/101°Fandabove,thescreenwilldisplayredasthebacklightcolorindicatingpossiblefever.
TheFeverInSight
®
featurecontinuesforabout5seconds.
4. TURNING THE THERMOMETER OFF
TurnthethermometeroffbypressingtheOn/Offbutton.Ifyouforgettoturnitoff,thethermometerwillautomaticallyturnoffafter
approximately11/2minutes.
CHANGING TEMPERATURE SCALE FROM °C TO °F OR °F TO °C
Whenthepowerisoff,pressandholdtheOn/Offbuttonfor4seconds,whenthe“M”symboldisappears,releasethebuttonandpressthe
buttontoswitchfrom°Cto°For°Fto°C.After3secondsidle,thethermometerentersintotheready-for-measurementmode.
CLEANING INSTRUCTIONS
• Cleanthethermometerbywashingitwithsoapandwarmwaterorrubbingalcohol(70%isopropylalcohol).
• Wipedrywithsoftcloth.
• DONOTBOILORWASHINDISHWASHER.Thiswillcausethethermometertonolongerfunctionandwillvoidthewarranty.
• Donotwashwithanythinnerorchemicalsolvent.
SPECIFICATION
Type: DigitalThermometer(Predictive)
BatteryLife: morethan300measurementsorapproximately2yearsifusedeveryotherday.
Accuracyinwaterbath: +/-0.1°Cbetween35.5-41.6°Catroomtemperatureof21.6°C.
+/-0.2°Fbetween96.0-107°Fatroomtemperatureof71°F
TemperatureRange: 32.0-42.9°C.Iflessthan32.0°C“Lo”isdisplayed.Ifmorethan42.9°C“Hi”isdisplayed.
89.6-109.9°F.Iflessthan89.6°F“Lo”isdisplayed.Ifmorethan109.9°F“Hi”isdisplayed.
OperatingTemperature: +10°Cto+40°C(50°F-104°F),15%to95%RH
StorageTemperature: –25°Cto+60°C(-13°F-140°F),15%to95%RH
Ifthedeviceisnotusedwithinspeciedtemperatureandhumidityrangesthetechnicalaccuracyofthe
measurementcannotbeguaranteed.
Beeper: Thethermometerwillbeepforapproximately8secondswhenpeaktemperatureisreached.
Fortemperaturesover38.3°C/101°F,theaudibleFeverAlertwillsound5times.
ErrorMessages: Thedisplaywillread“Err”whenamalfunctionoccursandthethermometerwillpoweroff.
•EN12470-3 •ASTME1112
•IEC60601-1 •IEC60601-1-2
TEST PROTOCOL
(Laboratory use only)
1. Placethermometerintoastableliquidbathwithtemperaturesetabove35°C(95°F).Thetipofthethermometershouldbe
approximately0.8inches(2cm)belowthesurface.
2. Waitfor10seconds,thenturnthermometeronbypressingtheblue“On/Off”button.
3. Whenthemeasurementiscompleted(approximately8seconds),recordthetemperaturereading.
CHANGING THE BATTERIES
TheVicks
®
FeverInSight
®
Thermometerfeaturesalonglifebattery.Whenthe“
”appearsandashesinthecentertopofthedisplay,the
batteryisexhaustedandneedsreplacing.
1.Usingacoin,unlockthebatterycoverandcarefullyremovethebatterywithanon-metallicinstrument.
2.Replacethebatterywitha3V,CR1225lithiumtypeorequivalent.Insertthenewbatterywiththepositive(+)sidefacingthebatterycover.
3.Carefullyputthebatterycoverbackinplaceand,usingacoin,tightenthecover.
4.Properlydisposeoftheoldbattery.Keepoutofreachofyoungchildren,elderlyandpets.
LIFETIME WARRANTY
Thisproducthasbeenproducedwiththegreatestcarefornormal,householduse.Followingdirectionscarefullywillensuredependableoperation.Iffor
anyreason(otherthanmisuseornormalbatteryoperation)youaredissatisedwithyourVicks
®
FeverInSight
®
Thermometer,wewillrepairorreplaceit,
atouroption,atnochargeduringthelifetimewarrantyperiod.Modicationtotheproductbytheconsumerisnotauthorisedandvoidsthewarranty.
Ifthethermometerdoesnotfunctionproperly,rstcheckthebattery.Replaceifnecessary.Batteriesandpackagingareexcludedfromthewarranty.
Ifyouexperienceunsatisfactoryoperation,pleasecontactFeltonGrimwade&Bosisto’s.Ifrepairisrequiredunderthewarrantyperiod,theproduct
shouldbereturnedwithproofofpurchasetoFeltonGrimwade&Bosisto’sservicecentre.
Thepurchaserassumesresponsibilityforthepropercareanduseoftheproductinaccordancewiththeprintedoperatingmanual.Thepurchaseror
usermustmakehisorherjudgmentastowhentousetheproductandthelengthofuse.Keeptheoperationmanualavailableasitisyourguidetosafe,
efcientoperation.
OurgoodscomewithguaranteesthatcannotbeexcludedundertheAustralianConsumerLaw.Youareentitledtoareplacementorrefundforamajor
failureandforcompensationforanyotherreasonablyforeseeablelossordamage.Youarealsoentitledtohavethegoodsrepairedorreplacedifthe
goodsfailtobeofacceptablequalityandthefailuredoesnotamounttoamajorfailure.
Probe Tip
On/O Button
Large Display with
Fever InSight® backlight
Battery
Compartment
(on back side)
Important: Before first use,
remove label from the display.
Fig. 1
Fig. 2
Fig. 3 Fig. 4
Fig.5
Fig.6
P/N:31IMV916191 DATE:05SEP12
Distributedby:FeltonGrimwade&Bosisto’sPty.Ltd.
61-81ClarindaRoad(PoBox74),OakleighSouth,
Victoria3167,Australia
Website:www.fgb.com.au
BFTypeappliedpart. ConsultInstructionsforUse
ThestipulationsofEU-Directive93/42/EECfor
MedicalDevicesClassIIahavebeenfullled.
Manufacturing Quality Healthcare Products for Over 75 Years
ThisproductismanufacturedbyKazUSA,Inc.underlicensefromTheProcter
&GambleCompany.VicksandotherassociatedtrademarksareownedbyThe
Procter&GambleCompany. ©2012KazUSA,Inc. Allrightsreserved.
MadeandprintedinChina www.kaz.com/vicks
Pleasedonotdisposeoftheproductanditsbatteriesinthe
householdwasteattheendofitsusefullife.