Kidde 21026042 User manual

Category
Carbon monoxide (CO) detectors
Type
User manual

This manual is also suitable for

Combination
Smoke and
Carbon Monoxide
Alarm
Manual P/N 820-1417 Rev. C 2505-7231-01
For questions concerning your Smoke and Carbon Monoxide
Alarm, please call our Consumer Hotline at 1-800-880-6788.
User’s Guide for Model KN-COSMXTR-B
• Nuisance Alarm Reduction
• Advanced Ion Fire
Detection
• Battery Operated
• 2-LED Display
• Hush
®
• Peak Level Memory
For your convenience, write down the following information. If you call
our consumer hotline, these are the first questions you will be asked:
Alarm Model Number
(located on back of the alarm):
Date of Manufacture
(located on back of the alarm):
Date of Purchase:
Where Purchased:
ATTENTION: Please take a few minutes to thoroughly read this user’s
guide which should be saved for future reference and passed on to any
subsequent owner.
Introduction............................... 1
Product View.............................. 2
Features .................................. 4
Operating/Installation Instructions
Step 1: Installing Batteries ................... 8
Step 2: Installation Instructions:
A. Recommended Installation Locations....... 9
B. Where Not to Install ................... 12
C. How to Install ........................ 13
D. Tamper Resist Feature .................. 15
Step 3: Testing the Alarm ................... 16
Step 4: Hush
®
Control Feature ................ 17
Step 5: Peak Level Memory .................. 17
What to do if the Alarm Sounds
Smoke Alarm............................. 18
Carbon Monoxide Alarm .................... 20
Alarm Response Times ...................... 21
Battery Replacement ....................... 21
General Alarm Maintenance ................. 22
Carbon Monoxide Safety Information
General CO Information .................... 23
Possible Sources........................... 23
CO Safety Tips............................ 24
Symptoms of CO Poisoning .................. 24
Fire Safety Information
Escape Plan .............................. 25
Fire Prevention............................ 26
Industry Safety Standards
National Fire Protection Association ............ 27
California State Fire Marshall ................. 27
Consumer Product Safety Commission ......... 28
NRC.................................... 28
Warranty and Service Information ............ 29
Table of Contents
Thank you for purchasing the Kidde Combination Smoke and
Carbon Monoxide Alarm model KN-COSMXTR-B. This alarm
has a seven-year limited warranty. Please take a few minutes
to thoroughly read this user’s guide, and save for future
reference. Teach children how to respond to the alarms, and
that they should never play with the unit.
Your Kidde Smoke/CO Alarm was designed to detect
both smoke and carbon monoxide from any source
of combustion in a residential environment. It is not
designed for use in a recreational vehicle (RV) or boat.
If you have any questions about the operation or installation
of your alarm, please call our toll free Consumer Hotline
at 1-800-880-6788. The guide on page 26 will help you
determine the correct location of safety products that will
help keep your home a safer place.
1
Introduction
FRONT
Test/Reset/Hush
Button
Red LED
(Light Emitting Diode)
Green LED
(Light Emitting Diode)
Alarm Sounder
2
Product View
BACK
Battery Chamber
Battery Placement
3
3
2
1
INST ALL
THIRD
INST ALL
SECOND
INST ALL
FIRST
W ARNING:
BA TTERIES
HA VE BEEN
REMOVED
AA Battery
AA
AA
Battery
Battery
Product View
• Permanentindependentsmokeandcarbonmonoxide
sensors.
• Smoke alarm takes precedence when both smoke
and carbon monoxide are present.
• Alarm/Voicemessagewarningsystemthatalertsyouof
the following conditions in the manner described
below, thus eliminating any confusion over which
alarm is sounding:
FIRE: The alarm/voice pattern is three long alarm
beeps followed by the verbal warning message
“FIRE! FIRE!”. This pattern is repeated until the
smoke is eliminated. The red LED light will flash
while in alarm/voice mode.
CARBON MONOXIDE: The alarm/voice pattern is
four short alarm beeps followed by the verbal
warning message “WARNING! CARBON
MONOXIDE!”. After four minutes the alarm/voice
pattern will sound once every minute until the
unit is reset, or the CO eliminated. The red LED
light will flash while in alarm/voice mode.
LOW BATTERY: When the batteries are low and
need replacing the red LED light will flash and the
unit will “chirp” one time, followed by the warning
message “LOW BATTERY”. This cycle will occur once
every minute for the first hour. After the first hour
the red LED light will continue to flash every minute
accompanied by the “chirp” only sound. The voice
message “LOW BATTERY” will sound once every
fifteen minutes during the “chirp” only cycle.
This will continue for at least seven days.
• One“chirp”every30secondsisanindicationthat
the alarm is malfunctioning. If this occurs call the
Consumer Hotline at 1-800-880-6788.
• After seven (7) years of cumulative power up, this unit
will “chirp” twice every 30 seconds. This is an “opera-
tional end of life” feature which will indicate that it is time
to replace the alarm.
4
Features
• Loud85decibelalarm
• Nuisancealarmreduction
• Advancedionfiredetection
• Oversizedtestbuttonforeasyactivation
• Testbuttonperformsthefollowingfunctions:
Tests the units electronics and verifies proper unit
operation
Resets the unit during CO alarm
Peak Level Memory (see page 16)
Activates or Cancels Hush
®
Feature (see page 16)
• Mountingbracketdesignedforeasyorientation
of the unit
• GreenandredLEDlightsthatindicatenormal
operation and alarm status
Green Light: The green LED light flashes every 30
seconds to indicate the unit is operating properly
and once every 2 seconds to indicate the unit is in
HUSH
®
mode. The green light also flashes before a
CO reading is taken and when any button is
pressed.
Red Light: When a dangerous level of smoke or
carbon monoxide is detected the red LED light will
flash and the corresponding alarm pattern
(depending on the source) will sound. If the unit
malfunctions, the red LED light will flash and the
unit will chirp every 30 seconds indicating a system
problem.
• Poweredbythree(3)AAbatteries
• Batterylockoutsystemthatprohibitsinstallation
without using three batteries
• TamperResistFeaturethatdeterschildrenandothers
from removing the alarm
5
Features
Smoke Alarm
The smoke alarm monitors the air for products of combustion
that are produced when something is burning or smoldering.
When smoke particles in the smoke sensor reach a specified
concentration, the alarm/voice message warning system will
sound, and be accompanied by the flashing red LED light.
The smoke alarm takes precedence when both smoke
and carbon monoxide are present.
NFPA 72 states: Life safety from fire in residential occupancies
is based primarily on early notification to occupants of the
need to escape, followed by the appropriate egress actions
by those occupants. Fire warning systems for dwelling units
are capable of protecting about half of the occupants in
potentiallyfatalfires.Victimsareoftenintimatewiththefire,
too old or young, or physically or mentally impaired such that
they cannot escape even when warned early enough that
escape should be possible. For these people, other strategies
such as protection-in-place or assisted escape or rescue are
necessary.
•Smokealarms are devices that can provide early warn
ing of possible fires at a reasonable cost; however,
alarmshavesensinglimitations.Ionizationsensing
alarms may detect invisible fire particles (associated
with fast flaming fires) sooner than photoelectric
alarms. Photoelectric sensing alarms may detect visible
fire particles (associated with slow smoldering fires)
soonerthanionizationalarms.Homefiresdevelopin
different ways and are often unpredictable. For
maximum protection, Kidde recommends that both
IonizationandPhotoelectricalarmsbeinstalled.
•Abatterypoweredalarmmusthaveabatteryofthe
specified type, in good condition and installed properly.
•ACpoweredalarms(withoutbatterybackup)willnot
operate if the AC power has been cut off, such as by
an electrical fire or an open fuse.
•Smokealarms must be tested regularly to make sure
the batteries and the alarm circuits are in good
operating condition.
6
Smoke Alarm Features
•Smokealarmscannotprovideanalarmifsmokedoes
not reach the alarm. Therefore, smoke alarms may not
sense fires starting in chimneys, walls, on roofs, on the
other side of a closed door or on a different floor.
•Ifthealarmislocatedoutsidethebedroomorona
different floor, it may not wake up a sound sleeper.
•Theuseofalcoholordrugsmayalsoimpairone’s
ability to hear the smoke alarm. For maximum
protection, a smoke alarm should be installed in each
sleeping area on every level of a home.
•Althoughsmokealarmscanhelpsavelivesby
providing an early warning of a fire, they are not a
substitute for an insurance policy. Home owners and
renters should have adequate insurance to protect their
lives and property.
Carbon Monoxide (CO) Alarm
The carbon monoxide (CO) alarm monitors the air for the
presence of CO. It will alarm when there are high levels
of CO present, and when there are low levels of CO
present over a longer period of time. When a CO condition
matches either of these situations, the alarm/voice message
warning system will sound, and be accompanied by the
flashing red LED light. The carbon monoxide sensor uses an
electrochemical technology.
CAUTION: This alarm will only indicate the presence of
carbon monoxide gas at the sensor. Carbon monoxide
gas may be present in other areas.
Individuals with medical problems may consider using
warning devices which provide audible and visual signals for
carbon monoxide concentrations under 30 ppm.
7
Carbon Monoxide Alarm Features
Step 1: Installing Batteries
Batteries were not installed at the factory and must
be installed for the unit to operate! Install the three (3)
AA batteries in the back of the Smoke/CO Alarm.
•Themountingplatemustberemovedfromthebackof
the unit to install batteries. To remove, hold the
mounting plate and twist counterclockwise (left).
•
The battery polarity markings
on the bottom of the battery
compartment must be adhered to.
•Batteriesmustbeinstalledinthe
sequence shown. If the batteries
seem difficult to install, they’re
not being installed in the proper
sequence.
•Smoke/COAlarmwillnotengagetobracketunless
all three batteries are installed. Removal of any or all
batteries will render the Smoke/CO Alarm inoperative!
•Afterthebatteriesarecorrectlyinstalledtheunit
will beep once and the red LED light will flash. After
20-30 seconds the green LED light will flash indicating
the unit is now operational.
CAUTION: Your Smoke/CO Alarm is sealed and the
cover is NOT removable!
Operating and Installation Instructions
8
Batteries Must Be Installed in Order Shown Below:
Install
First
Install
Second
Install
Last
3
2
1
INST ALL
THIRD
INST ALL
SECOND
INST ALL
FIRST
W ARNING:
BA TTERIES
HA VE BEEN
REMOVED
AA Battery
AA
AA
Battery
Battery
3
2
1
Step 2: Installation Instructions
IMPORTANT: THIS ALARM MUST BE MOUNTED ON A
CEILING OR WALL. IT WAS NOT DESIGNED FOR USE
AS A TABLETOP DEVICE! INSTALL ONLY AS DETAILED!
A. Recommended Installation Locations:
Kidde recommends the installation of a Smoke/CO Alarm
in the following locations. For maximum protection we
suggest an alarm be installed on each level of a multilevel
home, including every bedroom, hallways, finished attics
and basements. Put alarms at both ends of bedroom,
hallway or large room if hallway or room is more than
30 ft. (9.1m) long. If you have only one alarm, ensure it is
placed in the hallway outside of the main sleeping area, or
in the main bedroom. Verify the alarm can be heard in all
sleeping areas.
Locate an alarm in every room where someone sleeps with
the door closed. The closed door may prevent an alarm not
located in that room from waking the sleeper. Smoke, heat
and combustion products rise to the ceiling and spread
horizontally.Mountingthealarmontheceilinginthecenter
of the room places it closest to all points in the room. Ceiling
mounting is preferred in ordinary residential construction.
When mounting an alarm on the ceiling, locate it at a
minimum of 4” (10cm) from the side wall (see diagram
A). If installing the alarm on the wall, use an inside wall
with the top edge of the alarm at a minimum of 4” (10cm)
and a maximum of 12” (30.5cm) below the ceiling (see
Diagram A).
Operating and Installation Instructions
9
Sloped Ceiling Installation:
The following information is from the National Fire Protection
Association and is listed in Fire Code 72. Install Smoke Alarms
on sloped, peaked or cathedral ceilings at, or within 3 ft
(0.9m)ofthehighestpoint(measuredhorizontally).NFPA72
states “Smoke alarms in rooms with ceiling slopes greater
than1ftto8ft(.3m-2.4m)horizontallyshallbelocatedon
the high side of the room”. NFPA 72 states “A row of alarms
shall be spaced and located within 3 ft (0.9 m) of the peak of
theceilingmeasuredhorizontally”(Seefigure2).
10
FIGURE 1
Operating and Installation Instructions
Mobile Homes:
Modern mobile homes have been designed and built to be
energy efficient. Install Smoke/CO alarms as recommended
above (refer to Recommended Installation Instructions and
figure 1). In older mobile homes that are not well insulated,
extreme heat or cold can be transferred from the outside
to the inside through poorly insulated walls and roof. This
may cause a thermal barrier, which can prevent smoke from
reaching an alarm mounted on the ceiling. In such mobile
homes install your Smoke/CO Alarm on an inside wall with
the top edge of the alarm at a minimum of 4 inches (10cm)
and a maximum of 12 inches (30.5cm) below the ceiling
(See figure 1). If you are not sure about the insulation in
your mobile home, or if you notice that the outer walls and
ceiling are either hot or cold, install your alarm on an inside
wall ONLY!
THIS EQUIPMENT SHOULD BE INSTALLED IN
ACCORDANCE WITH THE NATIONAL FIRE PROTECTION
ASSOCIATION’S STANDARD 72 (National Fire Protection
Association, Batterymarch Park, Quincy, MA 02269).
11
FIGURE 2
Operating and Installation Instructions
B. Where Not to Install:
Do not install in garages, kitchens, furnace rooms or
bathrooms! INSTALL AT LEAST 5 FEET AWAY FROM
ANY FUEL BURNING APPLIANCE.
Do not install within 3 ft (.9m) of the following: The door
to a kitchen, or a bathroom that contains a tub or shower,
forced air supply ducts used for heating or cooling, ceiling or
whole house ventilating fans, or other high air flow areas.
Avoid excessively dusty, dirty or greasy areas. Dust, grease or
household chemicals can contaminate the alarm’s sensors,
causing it to not operate properly.
Place the alarm where drapes or other objects will not block
the sensors. Smoke and CO must be able to reach the sensors
to accurately detect these conditions. Do not install in peaks
of vaulted ceilings, “A” frame ceilings or gabled roofs (see
diagram A). Keep out of damp and humid areas.
12
WARNING - This product is intended
for use in ordinary indoor locations of
family living units. It is not designed to
measure compliance with Occupational
Safety and Health Administration (OSHA)
commercial or industrial standards.
!
Operating and Installation Instructions
Install at least one (1) foot away from fluorescent lights,
electronic noise may cause nuisance alarms. Do not place
in direct sunlight and keep out of insect infested areas.
Extreme temperatures will effect the sensitivity of the Smoke/
CO Alarm. Do not install in areas where the temperature
is colder than 40 degrees Fahrenheit (4.4 Celsius) or hotter
than 100 degrees Fahrenheit (37.8 Celsius), such as garages
and unfinished attics. Do not install in areas where the
relative humidity (RH) is above 85%. Place away from doors
and windows that open to the outside.
Smoke alarms are not to be used with detector guards unless
the combination (alarm and guard) has been evaluated and
found suitable for that purpose.
C. How to Install:
To help identify the date to replace the unit, a label has been
affixed to the side of the alarm. Write the “Replace by”
date (7 years from initial power up) in permanent marker
on the label. See Alarm Replacement section for additional
information.
Remove mounting plate from the back of the unit by holding
the rim of the mounting plate and twisting counterclockwise
(left). See Diagram C. Hold the mounting plate against the
selected installation location (wall or ceiling) and mark the
center of the holes with a pencil.
13
Install
Remove
Mounting
Plate
DIAGRAM C
Operating and Installation Instructions
Drill a hole through the pencil
marks and use the enclosed
screws and anchors (see
diagram E) to secure (use 3/16”
drill bit for anchor holes). Align
the Smoke/CO Alarm with the
mounting plate and rotate
clockwise (right) until the unit
is aligned. Screw and anchor
accessories are supplied.
To ensure aesthetic alignment of the alarm with the hallway
or wall, the “A” line on the mounting plate should be parallel
withthehallwaywhenceilingmounting,orhorizontalwhen
wall mounting. See Diagram D.
14
Two labels are included with your alarm. They have important
information on what to do in case of an alarm. Add the
phone number of your emergency provider (Fire Department
or 911) in the space provided. Place one label next to the
alarm after it is mounted, and one label near a fresh air
source such as a door or window.
DIAGRAM D
DIAGRAM E
Operating and Installation Instructions
D. Tamper Resist Feature:
To make your smoke alarm tamper resistant, a tamper
resist feature has been provided. Activate the tamper resist
feature by breaking off the four posts in the square holes
in the trim ring (see figure A). When the posts are broken
off, the tamper resist tab on the base is allowed to engage
the mounting bracket. Rotate the alarm onto the mounting
bracket until you hear the tamper resist tab snap into place,
locking the alarm on the mounting bracket. Using the
tamper resist feature will help deter children and others
from removing the alarm from bracket. NOTE: To remove the
alarm when the tamper resist tab is engaged, press down on
the tamper resist tab, and rotate the alarm off of the bracket
(see figure B).
15
FIGURE A
FIGURE B
A
A
Posts
Operating and Installation Instructions
Step 3: Testing the Alarm
The test button has four purposes. It tests the unit’s elec-
tronics, resets the alarm, activates the Hush® feature, and
activates the peak level memory.
CAUTION: Due to the loudness (85 decibels) of the
alarm, always stand an arms length away from the
unit when testing.
• To test: Press and release the test/reset button and a
series of beeps will sound, followed by the message
“Fire! Fire!”, then another two series of beeps and the
message “Warning! Carbon Monoxide”, followed by 4
additional short beeps.
• Reset: If the Smoke/CO Alarm is sounding a CO alarm,
pressing the test/reset button will silence the alarm. If the
CO condition that caused the alert continues, the alarm
will reactivate. Reactivation times depend on the amount
of CO present. See page 21.
• Hush
®
: If the Smoke/CO Alarm is sounding a Smoke
alarm, pressing the test/reset button will temporarily
silence the alarm. If the smoke level continues to build,
the alarm will reactivate. See Step 4: Hush
®
Control
Feature.
• Peak Level Memory: If the green LED is blinking once
every16seconds,theunithasdetectedahazardous
condition. If the unit has detected a CO level of 100
PPM or greater, pushing the Test/Reset button will result
in a voice message “Caution, carbon monoxide previ-
ously detected”. Peak level also happens if the unit
detects smoke and then comes out of alarm. However,
there is no voice message if the unit is in peak level due
to smoke. When the Test/Reset button is pushed, the
unit exhibits a normal PTT if in peak level due to smoke.
Weekly testing is required! If at anytime it does not
perform as described, verify the three batteries are i nstalled
correctly and that they don’t need replacing. Clean dust and
other buildup off the unit. If it still doesn’t operate properly
call the Consumer Hotline at 1-800-880-6788.
16
Operating and Installation Instructions
Step 4: Hush
®
Control Feature
The Hush
®
featurehasthecapabilityoftemporarilydesensitizing
the smoke alarm circuit for approximately 10 minutes. This
feature is to be used only when a known alarm condition,
such as smoke from cooking, activates the alarm. You can put
your Smoke/CO Alarm in Hush
®
mode by pushing the test/
reset button. The unit will give a voice message “Hush mode
activated.” If the smoke is not too dense, the alarm will silence
immediately and the green LED light will flash every 2 seconds
for approximately 10 minutes. This indicates that the smoke
alarmisinatemporarilydesensitizedcondition.YourSmoke/CO
Alarm will automatically reset after approximately 10 minutes.
When the unit returns to normal operation after being in Hush
®
mode the alarm will sound if smoke is still present. The Hush
®
feature can be used repeatedly until the air has been cleared
of the condition causing the alarm. While the unit is in Hush
®
mode, pushing the test/reset button on the alarm will also end
the Hush
®
period. The unit will give a voice message “Hush
mode cancelled.”
NOTE: DENSE SMOKE WILL OVERRIDE THE HUSH
®
CONTROL FEATURE AND SOUND A CONTINUOUS ALARM.
CAUTION: BEFORE USING THE ALARM HUSH
®
FEATURE,
IDENTIFY THE SOURCE OF THE SMOKE AND BE CERTAIN
A SAFE CONDITION EXISTS.
Step 5: Peak Level Memory
If the green LED is blinking once every 16 seconds, the unit has
detectedahazardouscondition.IftheCOsensorhasdetecteda
CO level of 100 PPM or higher since last reset, it will be recorded
by the Peak Level Memory function. To access the Peak Level
Memory press the test/reset button. If a reading of 100 PPM
or higher has been recorded the unit will give a voice message
“Caution, Carbon Monoxide previously detected.” If you’ve
been away from home this feature allows you to check if there
was a CO reading of 100 PPM, or higher, during your absence.
Pushing the test/reset button resets the memory. It’s also reset
when the batteries are removed. There is no voice message
associated with peak level due to smoke. When the test/reset
button is pushed, the unit exhibits a normal PTT if the peak level
is due to smoke.
17
Operating and Installation Instructions
NEVER IGNORE THE SOUND OF THE ALARM!
Determining what type of alarm has sounded is easy
with your Kidde Combination Smoke/CO Alarm. The voice
message warning system will inform you of the type of
situation occurring. Refer to the Features section on page 4
for a detailed description of each alarm pattern.
When the smoke alarm sounds:
Smoke alarms are designed to minimize false alarms.
Cigarette smoke will not normally set off the alarm, unless
the smoke is blown directly into the alarm. This unit contains
advanced technology designed to reduce nuisance alarms,
such as from cooking particles. However, large quantities
of combustible particles from spills or broiling could still
cause the unit to alarm. Careful location of the unit away
from the kitchen area will give the maximum nuisance alarm
protection. Combustion particles from cooking may set off
the alarm if located too close to the cooking area. Large
quantities of combustible particles are generated from spills
or when broiling. Using the fan on a range hood which vents
to the outside (non- recirculating type) will also help remove
these combustible products from the kitchen.
If the alarm sounds, check for fires first. If a fire is discovered
follow these steps. Become thoroughly familiar with these
items, and review with all family members!
•Alertsmallchildreninthehome.Childrensleepvery
sound and may not be awakened by the sound of the
smoke alarms.
• Leaveimmediatelyusingoneofyourplannedescape
routes (see page 25). Every second counts, don’t stop
to get dressed or pick up valuables.
• Beforeopeninginsidedoorslookforsmokeseepingin
around the edges, and feel with the back of your hand
If the door is hot use your second exit. If you feel it’s
safe, open the door very slowly and be prepared to
close immediately if smoke and heat rush in.
• Iftheescaperouterequiresyoutogothroughsmoke,
crawl low under the smoke where the air is clearer.
18
What To Do When The Alarm Sounds!
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32