  • Hello! I am an AI chatbot trained to assist you with the TOA RS-442 Intercom Switch Board User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
4P removable terminal plug
(supplied with the N-8400RS)
N-8400RS Substation interface unit
To line 2 (Red)
Two pairs of
twisted pair cable
To handset
(
refer to the following figure)
Frame
ground
Switch input for
the call button 3
(momentary)
Switch input for
the call button 2
(momentary)
Switch input for
the call button 1
(momentary)
To line 1 (Brown)
To line 4 (Yellow)
(Green)
(Blue)
(Black)
RS-442
To line 3 (Orange)
8 Ω speaker output
(Red)
+
-
(Black)
(Gray)
(White)
(Brown)
(White)
(Blue)
(White)
*Open collector output: 24 V DC, Max. 30 mA
Control output
*
External
power supply
Relay
Diode
24 V DC
GND
+
-
Microphone
INSTALLATION MANUAL
SWITCH BOARD RS-442
Thank you for purchasing TOA’s Switch Board.
Please carefully follow the instructions in this manual to ensure long, trouble-free use of your equipment.
1. GENERAL DESCRIPTION
The RS-442 is a Switch board to be connected to the N-8400RS 4-wire system Substation Interface Unit.
It is equipped with 1 microphone input (with a microphone unit), 3 switch inputs for call buttons, and 1 speaker
output, enabling you to make a switch panel suitable for applications.
By assigning a different master station as a calling destination to each Call button, you can call one of them
and make a conversation.
2. CONNECTION
RS-442
Handset joint
cables
Handset cables
Wall surface
RS-481
RS-442 (Bottom)
Note
When using the RS-481 Option handset, cut the
jumper wire next to the handset joint cables on
the circuit board as illustrated below.
If not cut, sound comes out from the RS-442's
speaker and returns back to the handset’s
microphone, resulting in acoustic feedback.
Jumper wire
Handset joint cables
[RS-442 and RS-481 connections]
Note
Cut out unused wires to avoid short-circuiting.
3. INSTALLATION
3.1. Installation Completion Drawing
Unit: mm
[Front] [Side] [Rear]
88.1
91.2
130 – 150 130 – 150
28.1 67.5
3.2. When Making Operation Panel for Flush-Mount Installation
Put the RS-442 in the YC-302 2-Gang Electrical Box mounted in the wall.
Then, connect the cables from RS-442 to the switches mounted on the operation panel separately prepared.
Note: When using the PA paging function, keep the operation panel as far away from the PA paging speaker
as possible to avoid acoustic feedback.
4. SPECIFICATIONS
Call Button Wiring 6 cables (for 3 momentary switches)
Rated Input 1 W
Control Output Open collector, Maximum controlled voltage: 30 V DC
Control current: 30 mA
Microphone Electret condenser microphone
Wiring Twisted pair cables (2 pairs)
Transmission Range 1 km/ø0.5 mm (AWG24)
1.5 km/ø0.65 mm (AWG22)
2 km/ø0.9 mm (AWG19)
Operating Temperature 0 to 40 ºC
Weight 140 g
Note: The design and specications are subject to change without notice for improvement.
URL: http://www.toa.jp/
133-21-00014-00
Traceability Information for Europe
Manufacturer:
TOA Corporation
7-2-1, Minatojima-Nakamachi, Chuo-ku, Kobe, Hyogo, Japan
Authorized representative:
TOA Electronics Europe GmbH
Suederstrasse 282, 20537 Hamburg, Germany
Wall surface
RS-442
Operation panel (separately prepared)
YC-302
2-Gang Electrical Box
(option)
Tip
YC-822 Indoor Wall-Mount Box
can also be used.
/