ICP DAS USA tM-R5 is a 5-channel Form A power relay output data acquisition module. It provides 5 channels of Form A type relay output. Options are provided for configuring power-on and safe digital output values. 4 kV ESD protection and 3750 VDC intra-module isolation are also provided. It comes with Free EZ Data Logger Control and Monitoring software to help you easily set up a data acquisition system. Here are some of the possible use cases for the ICP DAS USA tM-R5:

  • Industrial automation: The tM-R5 can be used to control a variety of industrial equipment, such as motors, pumps, and valves.

ICP DAS USA tM-R5 is a 5-channel Form A power relay output data acquisition module. It provides 5 channels of Form A type relay output. Options are provided for configuring power-on and safe digital output values. 4 kV ESD protection and 3750 VDC intra-module isolation are also provided. It comes with Free EZ Data Logger Control and Monitoring software to help you easily set up a data acquisition system. Here are some of the possible use cases for the ICP DAS USA tM-R5:

  • Industrial automation: The tM-R5 can be used to control a variety of industrial equipment, such as motors, pumps, and valves.
tM-R5 5-channel Form A Power Relay Output DAQ module - QuickStart (Feb/2016)
ICP DAS USA, Inc. | www.icpdas-usa.com | 1-310-517-9888 | 24309 Narbonne Ave. Suite 200. Lomita, CA 90717
1
tM-R5
5-channel Form A Power Relay Output
Data Acquisition module
Quick Start Guide
Product Website:
http://www.icpdas-usa.com/tm_r5.html
1. Introduction
This quick start manual will guide users to implement the tM-R5
module into their applications in a quick and easy way. This will only
provide with the basic instructions. For the more detailed information,
please refer to the tM-R5 user’s manual located on the ICPDAS CD-ROM
or from ICP DAS web site:
http://www.icpdas-usa.com/documents/tM-Series_DIO_User_Manual.pdf
The tM-R5 is a 5 channel relay output data acquisition module. It provides
5 channels of Form A type relay output. Options are provided for
configuring power-on and safe digital output values. 4 kV ESD protection
and 3750 VDC intra-module isolation are also provided. It comes with Free
EZ Data Logger Control and Monitoring software to help you easily set up a
data acquisition system.
Figure 1-1: tM-R5 Module
tM-R5 5-channel Form A Power Relay Output DAQ module - QuickStart (Feb/2016)
ICP DAS USA, Inc. | www.icpdas-usa.com | 1-310-517-9888 | 24309 Narbonne Ave. Suite 200. Lomita, CA 90717
2
2. Terminal Assignment
3. Block Diagram
tM-R5 5-channel Form A Power Relay Output DAQ module - QuickStart (Feb/2016)
ICP DAS USA, Inc. | www.icpdas-usa.com | 1-310-517-9888 | 24309 Narbonne Ave. Suite 200. Lomita, CA 90717
3
4. Wiring
5. Default Settings
Default settings for the tM DIO modules are as follows:
Protocol: Modbus RTU
Module Address: 01
DIO Type: Type 40
Baud Rate: 9600 bps
6. Configuration
1. Booting the tM-R5 in Init mode.
Make sure the switch placed in the “init” position.
tM-R5 5-channel Form A Power Relay Output DAQ module - QuickStart (Feb/2016)
ICP DAS USA, Inc. | www.icpdas-usa.com | 1-310-517-9888 | 24309 Narbonne Ave. Suite 200. Lomita, CA 90717
4
2. Connecting to the PC and the Power Supply
tM-R5 5-channel Form A Power Relay Output DAQ module - QuickStart (Feb/2016)
ICP DAS USA, Inc. | www.icpdas-usa.com | 1-310-517-9888 | 24309 Narbonne Ave. Suite 200. Lomita, CA 90717
5
tM-R5 5-channel Form A Power Relay Output DAQ module - QuickStart (Feb/2016)
ICP DAS USA, Inc. | www.icpdas-usa.com | 1-310-517-9888 | 24309 Narbonne Ave. Suite 200. Lomita, CA 90717
6
3. Open DCON utility pro
click on COM port(first icon).
It can select multi-options such as Baud Rate, Protocol, Checksum, and Format to
search module. The default settings for the module can be found in Section 3. Click OK
after selecting the COM port setting.
tM-R5 5-channel Form A Power Relay Output DAQ module - QuickStart (Feb/2016)
ICP DAS USA, Inc. | www.icpdas-usa.com | 1-310-517-9888 | 24309 Narbonne Ave. Suite 200. Lomita, CA 90717
7
5. DCON utility pro will search for the selected COM port according the setting
previously set. DCON Utility Pro supports DCON and Modbus protocol for all ICPDAS
and the others modules.
6. Configuration I/O module setting on PC
tM-R5 5-channel Form A Power Relay Output DAQ module - QuickStart (Feb/2016)
ICP DAS USA, Inc. | www.icpdas-usa.com | 1-310-517-9888 | 24309 Narbonne Ave. Suite 200. Lomita, CA 90717
8
7. Rebooting the tM-R5 module in normal mode
Make sure the INIT switch is placed in the “Normal” position
8. Starting the module operation
After rebooting the tM-R5 module, search for the module to make sure the settings have
been changed. You can double click on the name of the module in the list to open the
configuration dialog box.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

ICP tM-R5 Quick Start

Type
Quick Start

ICP DAS USA tM-R5 is a 5-channel Form A power relay output data acquisition module. It provides 5 channels of Form A type relay output. Options are provided for configuring power-on and safe digital output values. 4 kV ESD protection and 3750 VDC intra-module isolation are also provided. It comes with Free EZ Data Logger Control and Monitoring software to help you easily set up a data acquisition system. Here are some of the possible use cases for the ICP DAS USA tM-R5:

  • Industrial automation: The tM-R5 can be used to control a variety of industrial equipment, such as motors, pumps, and valves.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI