MGF Euramco Ramfan Ventilator User guide

Type
User guide
USER GUIDE: EURAMCO RAMFAN
VENTILATOR
mgf.co.uk
WARNINGS
WARNING – Do not try to modify or
change the equipment in any way as this
could void any warranty or cause damage
to this equipment or persons using it
WARNING – Do not drop or throw the
unit as this may damage the internal
components
ALWAYS – Ensure the switch is in the OFF
position before connecting the blower to a
power supply
ALWAYS – Run the blower on a stable
surface
ALWAYS – Keep out of water
ALWAYS – Keep air intakes clear
PLEASE READ & UNDERSTAND THIS USER GUIDE
PRIOR TO COMPILING A SAFE SYSTEM OF WORK
AND USING THE EQUIPMENT SUPPLIED
For the latest version of this document visit mgf.co.uk
E: safety@mgf.ltd.uk | W: mgf.ltd.uk
HEAD OFFICE
GRANT HOUSE
LOCKETT ROAD
ASHTON IN
MAKERFIELD
WIGAN
WN4 8DE
ENGINEERING
CENTRE
FOUNDATION HOUSE
WALLWORK ROAD
ASTLEY
MANCHESTER
M29 7JT
mgf.co.uk
enquiries@mgf.co.uk
0808 163 7672
NORTH EAST  DURHAM
DEPOT
Thistle Road, Littleburn Ind.
Est., Langley Moor, County
Durham, DH7 8HJ
T: 01913 782100
YORKSHIRE 
CASTLEFORD DEPOT
Allerton Bywater Business
Park, Newton Lane
Castleford, WF10 2AL
T: 01977 521930
NORTH WEST 
ASTLEY DEPOT
Wallwork Road
Astley
Manchester
M29 7JT
T: 01942 896282
EAST ANGLIA 
STANTON DEPOT
Unit 5, O’Brien Ind.
Est., Grove Lane
Stanton, Bury St.
Edmunds, Suffolk
IP31 2BF
T: 01359 252204
LONDON 
DARTFORD DEPOT
Ray Lamb Way
Manor Road
Erith, Kent, DA8 2LB
T: 01322 344520
SOUTH EAST  TRING
DEPOT
Units 21 & 22, Airfield Ind.
Est., Cheddington Lane
Long Marston, Tring
Hertfordshire, HP23 4QR
T: 01296 663250
SOUTH WEST  EXETER
DEPOT
Unit 58, Greendale Business
Park, Woodbury Salterton
Exeter, EX5 1EW
T: 01395 233194
SOUTH WEST 
BRISTOL DEPOT
Severn Road
Chittening
Avonmouth
Bristol, BS11 0YL
T: 01179 820706
MIDLANDS 
RUGELEY DEPOT
Redbrook Lane
Brereton, Rugeley
Staffordshire
WS15 1QU
T: 01889 574777
WEST LOTHIAN 
LIVINGSTON DEPOT
Letham Road, Houstoun Ind.
Est. Livingston, West Lothian
EH54 5BY
T: 01506 535556
E) Set switch to ON.
F) Check for proper operation before leaving the
unit unattended.
G) Do not move or carry the blower while it is
running.
7. STORAGE AND CARE
The RamFan should be stored in a clean, cool,
dry area, in the storage box provided by MGF.
8. DISCLAIMER
Failure to adhere to the instructions supplied
with the equipment may invalidate any claims
with respect to damage, death or injury due to
the misuse or malfunctioning of the apparatus.
1. IMPORTANT NOTES
For the use of MGF supplied equipment only.
Ensure users are fully trained in the operation
of this equipment and a site specific safe
system of works is in place and adhered to.
It is essential that site specific risk
assessments are undertaken.
Do not try to modify or change the equipment in
any way as this could void any warranty or
cause damage to equipment or persons using
it.
If in doubt concerning the integrity of any part
of the equipment DO NOT USE IT
2. EURAMCO RAMFAN VENTILATOR
You have been supplied with a Euramco
RamFan, this is a powerful yet portable air-
mover which is ideal for use in confined spaces.
The double-wall, polyethylene casing is light-
weight, hard-wearing, and corrosion and
chemical resistant.
This fan comes in two sizes: 8”/20cm (UB20) or
12”/30cm (UB30).
Your fan can be supplied with standard ducting,
or a quick-release canister containing 7.6m of
ducting.
3. ACCESSORIES
We can provide a number of accessories with
the RamFan if required:
M.E.D. Manhole entry system
- Allows workers to enter and exit small man-
size openings while maintaining continuous
ventilation. Without such a device, duct fills the
manhole opening, preventing rapid entry and
exit.
mgf.co.uk
Extended Duct System – (Turbo-Couple)
Quickly connects two or more RamFan UB20
blowers in series to increase airflow up to 50%
when blowing through long and windy duct
runs. Long, windy duct runs need more power
and pressure to deliver sufficient airflow.
The Turbo-Couple delivers what is needed by
quickly joining two or more UB20’s in series.
4. MGF EXAMINATION AND TESTING
• Upon return to MGF the equipment will be
cleaned, inspected and function tested by a
competent and trained MGF safety technician.
5. VISUAL INSPECTION/FUNCTIONAL TEST -
PRIOR TO USE
Before the start of each use ensure that the
equipment is clean and free from debris and
there are no obvious defects.
• Ensure that the item has a green tag, stating
when it was last inspected.
• Each item comes with a unique ID number,
please ensure this can be found.
6. USING THE EURAMCO RAMFAN
A) Wear both eye and ear protection.
B) Position the fan on a level service.
C) Note the airflow direction arrow on the external
housing.
D) Ensure switch is in the OFF position, plug in to
a standard outlet with the correct voltage and
amperage set.
  • Page 1 1
  • Page 2 2

MGF Euramco Ramfan Ventilator User guide

Type
User guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI