D13695.01 Page 2
Conguration
To do the initial conguration of the IP-address of the System Controller Board and Media Board through the
Front Panel, follow the instructions below:
1. Switch on the TANDBERG MPS 200 by pressing the power switch button on the back to ‘1’.
The system is ready for conguration when the Power and Active LED’s on the Media Processing Boards
are green and the menu appears at the LCD.
2. Press the up arrow button to get to the start menu.
3. Press the conrm button ‘V’ to start Parameter Cong.
4. Press the conrm button ‘V’ to start the SC IP Cong.
5. Use the arrow buttons to set the following parameters:
• IP: Denes the static IP address of the System Controller Board
• SNM: Denes the static IP Subnet Mask for the network
• GW: Denes the static IP Gateway address
• IF Speed: Denes the Ethernet speed
6. Use the arrow buttons to select Media IP Cong and press the conrm button ‘V’.
7. Press the conrm button ‘V’ to start the Media 1 IP Cong.
8. Use the arrow buttons to set the following parameters:
• IP: Denes the static IP address of the Media board
• SNM: Denes the static IP Subnet Mask for the network
• GW: Denes the static IP Gateway address
• IF Speed: Denes the Ethernet speed
9. Restart the TANDBERG MPS 200.
Accessing the TANDBERG MPS 200
After conguring the IP-address of the System Controller Board, you may access the TANDBERG MPS 200 by
entering the IP-address of the System Controller Board in a standard WEB-browser. You will then be asked to
enter a password. It is not necessary to enter ‘User Name’. The default password for the TANDBERG MPS 200
is ‘TANDBERG’. Remember that the password is case sensitive.
Connecting Cables (rear)
Power cable and power switch at the rear of the MPS 200.
Power
SERIAL 3/4
ENET 2 ENET 1
COM 1
KB/MS