Mitsubishi Electric A9GT-BUS2SU type Multidrop Bus User manual

Type
User manual
A9GT-BUS2SU t
y
pe Multidrop
Bus connection interface
User’s Manual
Thank you for purchasing the MELSEC-GOT Series.
To ensure correct use of this equipment, please carefully read this
manual prior to use.
MODEL A9GT-BUS2SU-U
MODEL
CODE
1DM125
IB(NA)-0800077-C(0406)MEE
Mitsubishi Graphic Operation Terminal
DANGER
CAUTION
z SAFETY PRECAUTIONS z
(Always read before starting use)
When using Mitsubishi equipment, thoroughly read this manual and the
associated manuals introduced in the manual. Also pay careful attention to
safety and handle the module properly.
The instructions given this manual are concerned with this product. Refer to the
User
s Manual of the CPU module in use for details on the safety instructions
for the programmable logic controller system.
These
SAFETY PRECAUTIONS classify the safety precautions into two
categories: "DANGER" and "CAUTION".
Procedures which may lead to a dangerous condition
and cause death or serious injury if not carried out
properly.
Procedures which may lead to a dangerous condition
and cause superficial to medium injury, or physical
damage only, if not carried out properly.
Depending on circumstances, procedures indicated by
CAUTION
may also
be linked to serious results.
In any case, it is important to follow the directions for usage.
Store this manual in a safe place so that you can take it out and read it
whenever necessary. Always forward it to the end user.
[DESIGN PRECAUTIONS]
DANGER
z
Do not bundle control lines or communication wires together with main
circuit or power lines, or lay them close to these lines.
As a guide, separate the lines by a distance of at least 100 mm (3.94 inch)
otherwise malfunctions may occur due to noise.
[INSTALLATION PRECAUTIONS]
DANGER
z
Before mounting or dismounting this module to or from the GOT, always
shut off GOT power externally in all phases.
Not doing so can cause a module failure or malfunction.
z
Before connecting the Bus connection cable to this module, always shut off
GOT power and PLC CPU power externally in all phases.
Not doing so can cause a malfunction.
[INSTALLATION PRECAUTIONS]
CAUTION
z Use this module in the environment given in the general specifications of the GOT
User's Manual.
Not doing so can cause an electric shock, fire, malfunction or product damage or
deterioration.
z When installing this unit to the GOT, fit it to the connection interface of the GOT
and tighten the mounting screws in the specified torque range.
Undertightening can cause a drop, failure or malfunction.
Overtightening can cause a drop, failure or malfunction due to GOT or screw
damage.
[WIRING PRECAUTIONS]
CAUTION
z Insert and fit the bus connection cable into the connector of the module to be
connected until it "clicks".
After fitting, check for an unsung fit.
Not doing so can cause a malfunction due to a connection fault.
[STARTUP AND MAINTENANCE PRECAUTIONS]
DANGER
z Do not change the switch setting during power-on.
Doing so can cause a malfunction.
z Before starting cleaning, always shut off GOT power externally in all phases.
Not doing so can cause a module failure or malfunction.
CAUTION
z Do not disassemble or modify any module.
This will cause failure, malfunction, injuries, or fire.
z Do not touch the conductive areas and electronic parts of this module directly.
Doing so can cause a module malfunction or failure.
z Always secure the cables connected to the module, e.g. run them in conduits or
clamp them.Not doing so can cause module or cable damage due to dangling,
moved or accidentally pulled cables or can cause a malfunction due to a cable
contact fault.
z Do not hold the cable part when unplugging any cable connected to the module.
Doing so can cause module or cable damage or a malfunction due to a cable
contact fault.
z Before handling the unit, touch a grounded metal or similar object to discharge the
static electricity from the human body.
Failure to do so may cause the unit to fail or mulfunction.
[DISPOSAL PRECAUTIONS]
CAUTION
z Dispose of this product as industrial waste.
Manuals
The following manuals are relevant to this product.
Refer to the following list and order the required manuals.
Detailed Manuals
Manual name
Manual No.
(Model code)
A985GOT/A975GOT/A970GOT/A960GOT User’s Manual
(Available as option)
SH-4005
(1DM099)
A950GOT/A951GOT/A953GOT/A956GOT User’s Manual
(Available as option)
SH-080018
(1DM103)
Relevant Manual
For relevant manual, refer to the PDF manual stored within the drawing software.
Conformation to the EMC Directive
A9GT-BUS2SU conforms to the EMC Directive only when connected to the GOT
(with CE logo printed on the rating plate) which conforms to the EMC Directive.
For details of Conformation to the EMC Directive, refer to the using GOT User's
Manual (Hardware).
1. Overview
TThis User's Manual describes the A9GT-BUS2SU type Multidrop Bus connection
interface module (hereinafter, A9GT-BUS2SU).
The A9GT-BUS2SU is mounted on the A985GOT(-V)/A975GOT/A970GOT/A960GOT/
A956GOT/A956WGOT (hereinafter, GOT) to PLC system via a bus.
The A9GT-BUS2SU is a dedicated module for the GOT-A900 Series.
When one GOT is connected, this module can also be used. (When you are planning
to connect more than one GOT in the future, we recommend you to use this module.)
A9GT-BUS2SU
A9GT-BUSSU or
A9GT-BUS2SU
GOT Back
Main base unit/
extension base uni
t
Bus connector
conversion module
(A7GT-CNB)
GOT Back
With the A9GT-BUS2SU, the dimensions of the cable that protrudes from the bottom of
the GOT are smaller than the A9GT-BUSS/A9GT-BUS2S type bus connection interface
board (hereinafter, bus connection board) used with the conventional bus connection.
In case of A97GOT
Type A B
Bus connection
board
61
(2.4)
85
(3.35)
A9GT-BUS2SU
69
(2.72)
15
(0.59)
In case of A985GOT/A960GOT
Type A B
Bus connection
board
64
(2.52)
100
(3.9)
A9GT-BUS2SU
72
(2.83)
30
(1.18)
A
Bus connection
board used
A9GT-BUS2SU
used
B
B
A
Unit: mm (inch)
The applicable CPU and system configuration is the same as the conventional bus
connection board.
Refer to the GOT-A900 Series User's Manual (Connection System Manual) for the
configuration of the bus connection system.
The A9GT-BUS2SU cannot be used together with the bus connection board.
After opening the container, check that the following products are present.
Description Quantity
A9GT-BUS2SU 1
2. Specification
Item Specification
I/O occupied points 32 points (I/O assignment: Special 32 points)
CPU 5VDC 30.0 (220*1)Internal
consumed current
[mA]*1
GOT 5VDC Included in GOT
Weight [kg](lb) 0.18 (0.4)
*1: Supplied from the GOT side when GOT power is on.
Supplied from the PC system side when GOT power is off.
*2: State with PLC CPU power ON and GOT power OFF.
3. Name of the Parts and Outline Dimension Drawing
(1)
(5)
(2)
(5)
(8)
(7)
(3)
(6)
(4)
5
(0.2)
34
(1.34)
149(5.87)
99(3.9)
Unit: mm (inch)
No. Name Description
(1)
Extension number
setting switch
Used to set the extension number for GOT
assignment.
(Factory setting: 0)
<Setting range>
1 to 7 : Extension number
8, 9, 0: Must not be used.
(2)
I/O slot
setting switch
Used to set the I/O slot number for GOT
assignment.
(Factory setting: 0)
<Setting range>
0 to 7: I/O slot number
8, 9 : Must not be used.
(3)
Interface for connection of the bus connection
cable (IN side)
(4)
Bus connection cable
connecting interface
Interface for connection of the bus connection
cable (OUT side)
(5) mounting screw Screw for mounting to the GOT (M3 screw)
(6) Connector Connector for connection to the GOT
(7) Caution plate -
(8) Rating plate -
4. Installation Procedure
(1)
(2)
(1)
(1)
(1) Fit the communication module securing
fixtures in the GOT main unit.
(2) Mount the A9GT-BUS2SU on the GOT
interface.
(3)
(3)
(3)
(3) Tighten and fix the mounting screws (3
pcs.) of the A9GT-BUS2SU in the
specified torque range.
Warranty
Mitsubishi will not be held liable for damage caused by factors found not to be the cause of
Mitsubishi; machine damage or lost profits caused by faults in the Mitsubishi products;
damage, secondary damage, accident compensation caused by special factors
unpredictable by Mitsubishi; damages to products other than Mitsubishi products; and to
other duties.
For safe use
y This product has been manufactured as a general-purpose part for general industries,
and has not been designed or manufactured to be incorporated in a device or system
used in purposes related to human life.
y Before using the product for special purposes such as nuclear power, electric power,
aerospace, medicine or passenger movement vehicles, consult with Mitsubishi.
y This product has been manufactured under strict quality control. However, when installing
the product where major accidents or losses could occur if the product fails, install
appropriate backup or failsafe functions in the system.
U.S.A Mitsubishi Electric Automation Inc.
500 Corporate Woods Parkway Vernon
Hills, IL 60061
Tel : +1-847-478-2100
Brazil MELCO-TEC Rep. Com.e Assessoria
Tecnica Ltda.
AV. Paulista 1471, Conj. 308,
Sao Paulo City, Sao Paulo State,
Brazil
Tel : +55-11-283-2423
Germany Mitsubishi Electric Europe B.V. German
Branch
Gothaer Strasse 8 D-40880 Ratingen,
GERMANY
Tel : +49-2102-486-0
U.K Mitsubishi Electric Europe B.V. UK
Branch
Travellers Lane, Hatfield, Herts., AL10
8XB,UK
Tel : +44-1707-276100
Italy Mitsubishi Electric Europe B.V. Italian
Branch
Centro Dir. Colleoni, Pal. Perseo-Ingr.2
Via Paracelso 12, 20041 Agrate B.,
Milano, Italy
Tel : +39-039-6053344
Spain Mitsubishi Electric Europe B.V. Spanish
Branch
Carretera de Rubi 76-80
08190 - Sant Cugat del Valles,
Barcelona, Spain
Tel : +34-93-565-3131
France Mitsubishi Electric Europe B.V. French
Branch
25 Boulevard des Bouvets, F-92741
Nanterre Cedex, France
TEL: +33-1-5568-5568
South Africa Circuit Breaker Industries LTD.
Tripswitch Drive, Elandsfontein Gauteng,
South Africa
Tel : +27-11-928-2000
Hong Kong Ryoden Automation Ltd.
10th Floor, Manulife Tower, 169 Electric
Road, North Point, HongKong
Tel : +852-2887-8870
China Ryoden Automation Shanghai Ltd.
3F Block5 Building Automation
Instrumentation Plaza 103 Cao Bao Rd.
Shanghai 200233 China
Tel : +86-21-6475-3228
Taiwan Setsuyo Enterprise Co., Ltd.
6F., No.105 Wu-Kung 3rd.RD, Wu-Ku
Hsiang, Taipei Hsine, Taiwan
Tel : +886-2-2299-2499
Korea HAN NEUNG TECHNO CO.,LTD.
1F Dong Seo Game Channel Bldg.,
660-11, Deungchon-dong Kangsec-ku,
Seoul, Korea
Tel : +82-2-3660-9552
Singapore Mitsubishi Electric Asia Pte, Ltd.
307 ALEXANDRA ROAD #05-01/02,
MITSUBISHI ELECTRIC BUILDING
SINGAPORE 159943
Tel : +65-6473-2308
Thailand F. A. Tech Co.,Ltd.
898/28,29,30 S.V.City Building,Office
Tower 2,Floor 17-18 Rama 3 Road,
Bangkpongpang, Yannawa,
Bangkok 10120
Tel : +66-2-682-6522
Indonesia P.T. Autoteknindo SUMBER MAKMUR
Jl. Muara Karang Selatan Block A Utara
No.1 Kav. No.11 Kawasan Industri/
Pergudangan Jakarta - Utara 14440
Tel : +62-21-663-0833
India Messung Systems Put,Ltd.
Electronic Sadan NO:111 Unit No15,
M.I.D.C BHOSARI,PUNE-411026
Tel : +91-20-712-2807
Australia Mitsubishi Electric Australia Pty. Ltd.
348 Victoria Road, PostalBag, No 2,
Rydalmere, N.S.W 2116, Australia
Tel : +61-2-9684-7777
Country/Region Sales office/Tel
When exported from Japan, this manual does not require application to the Ministry
of Economy, Trade and Industry for service transaction permission.
Specifications subject to change without notice.
Printed in Japan on recycled paper.
HEAD OFFICE : 1-8-12, OFFICE TOWER Z 14F HARUMI CHUO-KU 104-6212, JAPAN
NAGOYA WORKS : 1-14, YADA-MINAMI 5-CHOME, HIGASHI-KU, NAGOYA, JAPAN
Country/Region Sales office/Tel
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Mitsubishi Electric A9GT-BUS2SU type Multidrop Bus User manual

Type
User manual