Energizer EV190 User manual

  • Hello! I am an AI chatbot trained to assist you with the Energizer EV190 User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
INDUSTRIAL HEAVY DUTY
NOT INTENDED FOR RETAIL TRADE
Chemical System:
Zinc-Manganese Dioxide (Zn/MnO
2
)
(No Added Mercury or Cadmium)
Designation: ANSI-908CD, IEC-4R25X
Battery Voltage: 6 Volts
Operating Temp: -18ºC to 55ºC (0ºF to 130ºF)
Average Weight: 589 grams (20.8 oz.)
Volume: 480 cubic centimeters (29.2 cubic inch)
Average Capacity: 11 Ah to 0.8 volts / cell
(Rated at 25k ohms continuous at 21ºC)
Cell: Four No. 60 (size "F") in series
Terminals: Coil Spring
Jacket: Plastic
INTERNAL RESISTANCE VS. TEMPERATURE
The measurement is an approximation of the
battery's actual internal resistance. It is sensitive
to the loads and operator technique.
Schedule: Background Load 600 ohms
Pulse Load 10 ohms
Pulse Duration 1 second
0ºC (32ºF)
-21ºC (-4ºF)
THIS BATTERY WILL PASS FREELY THROUGH A
CYLINDRICAL TUBE 82.6 DIAMETER x 101.6 LONG.
ENERGIZER NO. EV190
Important Notice
This data sheet contains information specific to batteries manufactured at the time of its publication.
Contents herein do not constitute a warranty.
6V
45ºC (113ºF)
Temperature
21ºC (70ºF)
Industry Standard Dimensions in mm (inches)
Typical Ri (ohms)
10.0
0.7
0.9
1.0
Copyright © Eveready Battery Co. Inc. - All Rights Reserved
CONSTANT RESISTANCE PERFORMANCE
Typical Service
1
10
100
1000
1 10 100 1000
Discharge Resistance, Ohms
Service, Hours
3.0 Cutoff Voltage
4.4
Cutoff Voltage
5.2 Cutoff Voltage
EVEREADY BATTERY CO.
Internet: www.energizer.com
1-800-383-7323 / USA
1-800-383-7323 / CANADA
CONSTANT CURRENT DISCHARGE
Typical Service
1
10
100
1000
1 10 100 1000
Discharge Current, mA
Service Hours
3.0 Cutoff Voltage
4.4
Cutoff Voltage
5.2 Cutoff Voltage
1-800-383-7323 / USA
1-800-383-7323 / CANADA
+ 44 (0) 208 920 2306 / EUROPE
Form No. EBC - 3234A Page 1 of 2
Contents herein do not constitute a warranty.
This data sheet contains information specific to batteries manufactured at the time of its publication.
Important Notice
Typical Applications
Copyright © Eveready Battery Co. Inc. - All Rights Reserved
LIGHTING
2.8
3.6
4.4
5.2
6.0
6.8
0 8 16 24 32 40 48 56
Service, Hours
Voltage, CCV
Load: 33 ohms
Schedule: 30 min. ON
30 min. OFF
8 hours/day
EVEREADY BATTERY CO.
Internet: www.energizer.com
LIGHTING
2.8
3.6
4.4
5.2
6.0
6.8
0 5 10 15 20 25 30
Service, Hours
Voltage, CCV
Load: 16 ohms
Schedule: 30 min. ON
30 min. OFF
8 hours/day
LIGHTING
2.8
3.6
4.4
5.2
6.0
6.8
0 2 4 6 8 10
Service, Hours
Voltage, CCV
Load: 9.1 ohms
Schedule: 24 hrs/day
LIGHTING
2.8
3.6
4.4
5.2
6.0
6.8
0 2 4 6 8 10 12 14
Service, Hours
Voltage, CCV
Load: 9.1 ohms
Schedule: 30 min. ON
30 min. OFF
8 hours/day
Form No. EBC - 3234A Page 2 of 2
/