Warning: Installation of any components must be performed using appropriate anti-static devices. If unavailable, dis-
charge body static by touching a grounded metallic object before opening any covers on the hand-held.
WA9302 back cover includes:
• Torx T6 screws (x6)
• Flex cable (PN 1050450)
Important: Always disconnect the unit from all power sources (battery & A/C power) before servicing components.
1. Remove the battery and back cover (x6 screws).
2. Install the separate flex cable (PN 1050450) included with the WA9302 back cover into the 1D scanner con-
nector on the hand-held, and push down on the connector latch to lock the flex cable in place.
3. Install the other end of the flex cable into the top connector on the back cover, and push the connector latch
down to lock the flex cable in place
4. Connect the end-cap flex cable into the bottom connector on the WA9302 back cover.
5. Secure the WA9302 back cover using the 6 screws included. Torque to 2.5 in-lbs.
6. Install the battery and battery cover.
Flex cable
End-cap
PN 1050450
flex cable
1D scanner
connector
WA9302 back cover
top connector
Bottom
connector
(WA9302)
End-cap
flex cable
© 2015 Symbol Technologies, Inc.
Zebra and the Zebra head graphic are registered trademarks of ZIH Corp. The Symbol logo is a registered trademark of Symbol Technologies,
Inc., a Zebra Technologies company.
February 27, 2015
8000314-001 A
BACK COVER WITH SWITCH (WA9302) INSTALLATION SHEET
COMPANY HEADQUARTERS SUPPORT SERVICES
Zebra Technologies Corporation Contact the Zebra Global Customer Support at:
Lincolnshire, IL U.S.A. http://www.zebra.com/support.
http://www.zebra.com