LG LW6017R Owner's manual

Type
Owner's manual
www.lg.com
OWNER’S MANUAL
Please read this manual carefully before operating
your set and retain it for future reference.
TYPE :
WINDOW
AIR
CONDITIONER
MODELS LW6017R
NORSK SUOMI DANSK
P/NO : MFL69381604
Before Operation
7
15
18
Safety Precautions
Introduction
Electrical Safety
Installation
Operating Instructions
Maintenance and Service
Do not store flammables like
gasoline benzene thinner
etc. near the air conditioner.
No correlation between fan
usage and oxygen depletion.
Unplug the unit when not
using it for a long time.
Hold the plug by the head
it out.
not the cable when taking
Never touch the metal parts
of the unit when removing
the filter.
Install the product so the exhaust and noise
are not aimed directly at the neighbors.
When gas leaks, open the
window for ventilation before
operating the unit.
Be considerate.
Follow installation instructions exactly.
For inner cleaning, contact an Authorized Service Center or a dealer.
Do not use harsh detergent that causes corrosion or damage on the unit.
Harsh detergent may also cause failure of prod
uct, fire, or electric shock.
y
You will feel better.
Do not use this appliance for
special purposes such as
cooling pets
foods
precision
machinery or objects of art
If the liquid from the battery gets onto your skin
or clothers
wash it well with clean water. Do
not use the remote if the battery has leaked.
Instead of running air conditioning
constantly
open a window
for fresh air occasionally.
You will feel better.
y
If you eat the liquid from the battery,brush
your teeth and see doctor.Do not use the
remote if the battery has leaked.
2. No correlation between fan usage and oxygen depletion.
3.
CABINET
AIR FILTER
HORIZONTAL
AIR DEFLECTOR
FRONT GRILLE
RESET
TEST
Avoid shock hazard. This unit cannot
be user-serviced. Do NOT open the
tamper-resistant sealed portion.
All warranties and performance will
be voided. This unit is not intended
to be used as an ON/OFF switch.
USE OF EXTENSION CORDS
RISK OF FIRE could cause serious injury or death
DO NOT use an extension cord with this window
air conditioner
DO NOT use surge protectors or multi-outlet
adapters with this window air conditioner
should
be
This product contains chemicals
known to the State of California to cause cancer
and birth defects or other reproductive harm.
Wash hands after handling.
WARNING:
10
Phillips head
screwdriver
Scissors or
knife
J
Left Guide Panel
Right Guide Panel
Curtain
11
Clearance
and
12
drawing
in the drawing.
(Type A)
Screws
upper and bottom guide
with 4 screws (Type A) on each side.
(Type A)
Screws
5.
5-1
5-2
Screws
1. Install the upper guide(Tpye H) with
the case.
Curtain
(Type D)
Left Guide panel
Right Guide panel
Bottom Guide
3 screws(Tpye A) from the outside of
Upper Guide
(Type H)
1-1. Set the air conditioner in the window
so that is centered. Place the air
conditioner so that front edge of the
bottom guide is against the back
edge of the sill.
(Type G)
4
(2 Type B and 2 Type C) to secure
them.
1-2. Bring the window down so that the
front edge of the upper guide is in
front of the window. Make sure that
air conditioner is level or tilting
slightly to the outside.
CAUTION:
To prevent broken glass or
damage to windows, on vinyl or
other similarly constructed
windows, attach the window
locking bracket to the window
side jamb with one Type A screw.
Window Frame
Upper Guide
About
Bottom Guide
Bracket
Bracket
Type
Type
Type
Sash Seal
(Type F)
FAN SPEED SELECTOR
ON/OFF TIMER
OPERATION MODE SELECTOR
POWER
Operation starts when this button is pressed and stops when you press
the button again.
Use to set the fan speed to
to 24 hours at its previous mode and fan settings.
Approximately every 3 minutes the fan will turn on and check the room air temperature
if cooling is needed.
desired temperature and circulation fan speed
Push the MODE button to rotate between Energy Saver / Cool / Fan / Dry.
to 24 hours.
Low (F1), MED (F2), High (F3).
- when the air conditioner is off, it can be set to auto matically turn on from 1
Delay ON
- when the air conditioner is on, it can be set to auto matically turn off from 1
Delay OFF
- The fan stops when the compressor stops cooling.
Energy Saver
- Compressor runs and cools the room. Use the and FAN buttons to set the
Cool
desired fan speed
- Fan circulates air but compressor dose not run. Use the FAN button to set the
FAN
7
18
Slinger Fan
liquid wax
19
call 1-800-243-0000.
20
an outlet of the proper
voltage and amperage.
Water drip from the rear of the unit
Normal Sound
Today’s high efficiency compressors
may have a high pitched chatter
during the cooling cycle.
Unit may vibrate and
make noise because of poor
wall or window construction
At the front of the unit, you may
hear the sound of rushing air
being moved by the fan.
“Gurgling or hissing” noise may be
heard due to refrigerant passing
through evaporator during normal
operation.
Droplets of water hitting condenser
during normal operation may cause
“pinging or swishing” sounds
See
the section on Slinger Fan, page 16)
High pitched Chatter
Gurgle/Hiss
Pinging or Swishing
or incorrect installation.
Vibration
Sound of Rushing Air
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44

LG LW6017R Owner's manual

Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI

in other languages