Danfoss BasicRail, floor heating in heated screed User guide

Type
User guide
Floor Heating in Heated
Screed
Edge zone installation 1 (EZ 1)
Pipe distance: 88 mm Rails in cement screed (CT): 1.00 m per m²
Composite pipes: 11.25 m per m² Rails in liquid screed (CAF): 1.50 m per m²
Edge zone installation 2 (EZ 2)
Pipe distance: 120 mm Rails in cement screed (CT): 1.00 m per m²
Composite pipes: 8.33 m per m² Rails in liquid screed (CAF): 1.50 m per m²
Comfort zone installation 1 (CZ 1)
Pipe distance: 200 mm Rails in cement screed (CT): 1.00 m per m²
Composite pipes: 5.00 m per m² Rails in liquid screed (CAF): 1.50 m per m²
Application Sheet
BasicRail Heating System
Danfoss Heating Solutions VACTQ202 © Danfoss 11/2010 1
Comfort zone installation 2 (CZ 2)
Pipe distance: 250 mm Rails in cement screed (CT): 1.00 m per m²
Composite pipes: 4.00 m per m² Rails in liquid screed (CAF): 1.50 m per m²
Comfort zone installation 3 (CZ 3)
Pipe distance: 300 mm Rails in cement screed (CT): 1.00 m per m²
Composite pipes: 3.50 m per m² Rails in liquid screed (CAF): 1.50 m per m²
Application Sheet BasicRail Heating System
Danfoss A/S
Heating Solutions
Haarupvaenget 11
8600 Silkeborg
Denmark
Phone:+45 7488 8000
Fax: +45 7488 8100
www.heating.danfoss.com
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products
already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective
companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
2 VACTQ202 © Danfoss 11/2010 Danfoss Heating Solutions
  • Page 1 1
  • Page 2 2

Danfoss BasicRail, floor heating in heated screed User guide

Type
User guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI