Mitsubishi Electric FR-A7NS User manual

Category
Power adapters & inverters
Type
User manual
1
FR-A7NS INSTRUCTION MANUAL
C
INVERTER
INSTRUCTION MANUAL
INVERTER
2
3
4
5
6
7
8
9
INVERTER
Plug-in option
HEAD OFFICE: TOKYO BUILDING 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
FR-A7NS
SSCNET III communication function
PRE-OPERATION INSTRUCTIONS
INSTALLATION
WIRING
IB(NA)-0600308ENG-C(1110) MEE Printed in Japan Specifications subject to change without notice.
RESTRICTIONS ON THE
FUNCTIONS
PRECAUTIONS
ALARM INDICATION DEFINITIONS
AND CORRECTIVE ACTIONS
INVERTER SETTING AND
DISPLAY
SSCNET III COMMUNICATION
STATUS
TROUBLESHOOTING
A-1
Thank you for choosing this Mitsubishi Inverter plug-in option.
This instruction manual gives handling information and
precautions for use of this equipment. Incorrect handling might
cause an unexpected fault. Before using the equipment, please
read this manual carefully to use the equipment to its optimum.
Please forward this manual to the end user.
1. Electric Shock Prevention
This section is specifically about
safety matters
Do not attempt to install, operate, maintain or inspect this
product until you have read through this instruction manual and
appended documents carefully and can use the equipment
correctly. Do not use this product until you have a full
knowledge of the equipment, safety information and
instructions.
In this instruction manual, the safety instruction levels are
classified into "WARNING" and "CAUTION".
Assumes that incorrect handling may
cause hazardous conditions, resulting
in death or severe injury.
Assumes that incorrect handling may
cause hazardous conditions, resulting
in medium or slight injury, or may
cause physical damage only.
Note that even the level may lead to a serious
consequence according to conditions. Please follow the
instructions of both levels because they are important to
personnel safety.
WARNING
CAUTION
CAUTION
SAFETY INSTRUCTIONS
WARNING
While power is on or when the inverter is running, do not
open the front cover. You may get an electric shock.
Do not run the inverter with the front cover or wiring cover
removed. Otherwise, you may access the exposed high-
voltage terminals and charging part and get an electric shock.
If power is off, do not remove the front cover except for wiring
or periodic inspection. You may access the charged inverter
circuits and get an electric shock.
Before starting wiring or inspection, check to make sure that
the indication of the inverter operation panel is off, wait for at
least 10 minutes after the power supply has been switched off,
and check that there are no residual voltage using a tester or
the like. The capacitor is charged with high voltage for some
time after power off and it is dangerous.
Any person who is involved in the wiring or inspection of this
equipment should be fully competent to do the work.
Always install the plug-in option before wiring. Otherwise,
you may get an electric shock or be injured.
Do not touch the plug-in option with wet hands. Otherwise
you may get an electric shock.
Do not subject the cables to scratches, excessive stress,
heavy loads or pinching. Otherwise you may get an electric
shock.
A-2
2. Injury Prevention
3. Additional Instructions
Also note the following points to prevent an accidental failure,
injury, electric shock, etc.
1) Transportation and mounting
2) Trial run
3) Usage
4) Maintenance, inspection and parts replacement
5) Disposal
6) General instruction
CAUTION
Apply only the voltage specified in the instruction manual to
each terminal. Otherwise, burst, damage, etc. may occur.
Ensure that the cables are connected to the correct terminals.
Otherwise, burst, damage, etc. may occur.
Always make sure that polarity is correct to prevent damage, etc.
Otherwise, burst, damage may occur.
While power is on or for some time after power-off, do not touch
the inverter as it is hot and you may get burnt.
CAUTION
Do not install or operate the plug-in option if it is damaged or
has parts missing.
Do not stand or rest heavy objects on the product.
Check that the mounting orientation is correct.
Prevent other conductive bodies such as screws and metal
fragments or other flammable substance such as oil from
entering the inverter.
CAUTION
Before starting operation, confirm and adjust the parameters.
A failure to do so may cause some machines to make
unexpected motions.
WARNING
Do not modify the equipment.
Do not perform parts removal which is not instructed in this
manual. Doing so may lead to fault or damage of the inverter.
CAUTION
When parameter clear or all parameter clear is performed,
reset the required parameters before starting operations.
Each parameter returns to the initial value.
For prevention of damage due to static electricity, touch
nearby metal before touching this product to eliminate static
electricity from your body.
CAUTION
Do not test the equipment with a megger (measure insulation
resistance).
CAUTION
Treat as industrial waste.
All illustrations given in this manual may have been drawn with
covers or safety guards removed to provide in-depth
description. Before starting operation of the product, always
return the covers and guards into original positions as specified
and operate the equipment in accordance with the manual.
I
CONTENTS
1 PRE-OPERATION INSTRUCTIONS 1
1.1 Inverter Type ......................................................................................................................................1
1.2 Unpacking and Product Confirmation .............................................................................................2
1.2.1 Packing confirmation ......................................................................................................................................7
1.2.2 Parts ...............................................................................................................................................................8
1.3 Caution................................................................................................................................................9
1.4 Operation Overview .........................................................................................................................10
2 INSTALLATION 12
2.1 Pre-Installation Instructions ...........................................................................................................12
2.2 Shaft number Setting.......................................................................................................................13
2.3 Installation Procedure .....................................................................................................................14
3 WIRING 16
3.1 System configuration (when FR-A7AP is used)............................................................................16
3.2 Wiring example (when FR-A7AP is used)......................................................................................18
3.3 SSCNET III cable ..............................................................................................................................20
3.3.1 SSCNET III cable laying ...............................................................................................................................24
3.4 Wiring................................................................................................................................................26
4 SSCNET III COMMUNICATION STATUS 32
II
5 INVERTER SETTING AND DISPLAY 35
5.1 Parameter List ..................................................................................................................................35
5.2 Operation Mode Setting ..................................................................................................................36
5.2.1 Operation mode indication............................................................................................................................36
5.2.2 Operation mode switchover method.............................................................................................................37
5.3 Operation at Communication Error Occurrence...........................................................................40
5.3.1 Alarm and measures ....................................................................................................................................40
5.4 Inverter Reset ...................................................................................................................................41
5.5 Setting SSCNET III communication function ................................................................................42
5.5.1 Pr.499 SSCNET III operation selection ........................................................................................................42
5.5.2 Pr.379 SSCNET III rotation direction selection.............................................................................................47
5.5.3 Pr.449 SSCNET III input filter setting ...........................................................................................................48
5.5.4 Pr.52 DU/PU main display data selection.....................................................................................................48
5.5.5 Pr.185 JOG terminal function selection........................................................................................................49
5.5.6 Pr.800 Control method selection ..................................................................................................................49
6 RESTRICTIONS ON THE FUNCTIONS 50
6.1 Function Restriction List.................................................................................................................50
6.2 Inverter Parameter List....................................................................................................................53
6.3 Inverter I/O Terminal Function List ................................................................................................69
6.3.1 Input terminal function ..................................................................................................................................69
6.3.2 Output terminal function ...............................................................................................................................72
III
7 PRECAUTIONS 74
8 ALARM INDICATION DEFINITIONS AND CORRECTIVE ACTIONS 75
9 TROUBLESHOOTING 79
1
1
1 PRE-OPERATION INSTRUCTIONS
1.1 Inverter Type
The inverter type, 55K and 75K stated in this Instruction Manual differs according to each -NA, -EC, -CH(T)
versions. Refer to the following correspondence table for each inverter type. (Refer to the instruction manual
of each inverter for the inverter type.)
For example, "for the 75K or more" indicates "for the FR-A740-01440-NA or more" in the case of FR-A740
of NA version.
NA EC CH
A700
FR-A720-55K FR-A720-02150-NA ⎯⎯
FR-A720-75K FR-A720-02880-NA ⎯⎯
FR-A740-55K FR-A740-01100-NA FR-A740-01800-EC FR-A740-55K-CHT
FR-A740-75K FR-A740-01440-NA FR-A740-02160-EC FR-A740-75K-CHT
2
PRE-OPERATION INSTRUCTIONS
1.2 Unpacking and Product Confirmation
Take the plug-in option out of the package, check the unit name, and confirm that the product is as you
ordered and intact.
This product is a plug-in option for the FR-A700 series inverter assembled in and after January 2007.
Refer to the table below to check the SERIAL (Serial No.) indicated on the inverter rating plate or package.
(1) NA specification
z200V class
Inverter Type
Label on
Product
Package
Identification
Symbol
Lower Third
and Second
Number of
TC Number
on Rating
Plate
SERIAL
(Upper
Three
Numbers of
SERIAL)
FR-A720-00030-NA
Without G5
Q71
FR-A720-00050-NA P71
FR-A720-00080/
00110-NA
Without G5 Q71
<G> G7 D71
FR-A720-00175-NA
Without G5 R71
<G> G7 D71
FR-A720-00240/
00330-NA
Without G5
Q71
FR-A720-00460-NA P71
FR-A720-00610 to
00900-NA
R71
FR-A720-01150 to
01750-NA
Q71
FR-A720-02150-NA P71
FR-A720-02880/
03460-NA
M71
Inverter Type
Label on
Product
Package
Identification
Symbol
Lower Third
and Second
Number of
TC Number
on Rating
Plate
SERIAL
(Upper
Three
Numbers of
SERIAL)
3
PRE-OPERATION INSTRUCTIONS
1
z400V class
Inverter Type
Label on
Product
Package
Identification
Symbol
Lower Third
and Second
Number of
TC Number
on Rating
Plate
SERIAL
(Upper
Three
Numbers of
SERIAL)
FR-A740-00015 to
00310-NA
Without G5 Q71
<G> G7 E71
FR-A740-00380/
00440-NA
Without G5 Q71
<G> G7 F71
FR-A740-00570 to
00860-NA
Without G5 P71
<G> G7 E71
FR-A740-01100-NA
Without G5 P71
<G> G7 D71
FR-A740-01440
to 02660-NA
Without G5 M71
<G> G7 E71
FR-A740-03250-NA
Without G5 N71
<G> G7 F71
FR-A740-03610-NA
Without G5 M71
<G> G7 F71
FR-A740-04320/
04810-NA
Without G5 M71
<G> G7 E71
FR-A740-05470-NA
Without G5 N71
<G> G7 E71
FR-A740-06100-NA
Without G5 M71
<G> G7 D71
FR-A740-06830-NA
Without G5 J71
<G> G7 D71
FR-A740-07700/
08600-NA
Without G5 M71
<G> G7 D71
FR-A740-09620-NA
Without G5 N71
<G> G7 D71
Inverter Type
Label on
Product
Package
Identification
Symbol
Lower Third
and Second
Number of
TC Number
on Rating
Plate
SERIAL
(Upper
Three
Numbers of
SERIAL)
4
PRE-OPERATION INSTRUCTIONS
(2) EC specification
* For the FR-A740-00770 to 12120-EC
Check the SERIAL indicated on the Serial number sticker shown below.
To check the SERIAL, the front cover must be removed.
For the removal of the front cover, refer to the inverter manual.
Inverter Type
Label on
Product
Package
Identification
Symbol
Lower Third
and Second
Number of
TC Number
on Rating
Plate
SERIAL
(Upper
Three
Numbers of
SERIAL)
FR-A740-00023 to
00126-EC
Without G5 or G6 M71
<G> G7 or G8 F71
FR-A740-00170/
00250-EC
Without G5 or G6 N71
<G> G7 or G8 F71
FR-A740-00310/
00380-EC
Without G5 or G6 M71
<G> G7 or G8 F71
FR-A740-00470/
00620-EC
Without G5 N71
<G> G7 G71
FR-A740-00770 to
12120-EC*
⎯⎯
L71 or F71
Inverter Type
Label on
Product
Package
Identification
Symbol
Lower Third
and Second
Number of
TC Number
on Rating
Plate
SERIAL
(Upper
Three
Numbers of
SERIAL)
VUW
FR-CA70-EC 71
SERIAL
Control unit type
SERIAL (Serial No.)
Month
Serial number sticker example
The SERIAL consists of 1 version symbol, 2 numeric characters
or 1 numeric character and 1 alphabet letter indicating year and
month, and 3 numeric characters indicating control number.
Month is indicated as 1 to 9, X (October), Y (November), and Z
(December).
Year
Symbol
5
PRE-OPERATION INSTRUCTIONS
1
(3) CHT specification
Inverter Type
Label on
Product
Package
Identification
Symbol
Lower Third
and Second
Number of
TC Number
on Rating
Plate
SERIAL
(Upper
Three
Numbers of
SERIAL)
FR-A740-0.4K/
0.75K-CHT
Without G5 or G6 S71
<G> G7 or G8 E71
FR-A740-1.5K to
15K-CHT
Without G5 or G6 T71
<G> G7 or G8 E71
FR-A740-18.5K/
22K-CHT
Without G5 or G6 U71
<G> G7 or G8 F71
FR-A740-30K to
45K-CHT
Without G5 or G6 Q71
<G> G7 or G8 E71
FR-A740-55K-CHT
Without G5 or G6 Q71
<G> G7 or G8 D71
FR-A740-75K to
132K-CHT
Without G5 M71
<G> G7 E71
FR-A740-160K-CHT
Without G5 N71
<G> G7 F71
FR-A740-185K-CHT
Without G5 M71
<G> G7 F71
FR-A740-220K/
250K-CHT
Without G5 M71
<G> G7 E71
FR-A740-280K-CHT
Without G5 N71
<G> G7 E71
FR-A740-315K-CHT
Without G5 M71
<G> G7 D71
FR-A740-355K-CHT
Without G5 K71
<G> G7 D71
FR-A740-400K-CHT
Without G5 M71
<G> G7 D71
FR-A740-450K-CHT
Without G5 M71
FR-A740-500K-CHT
Without G5 N71
Inverter Type
Label on
Product
Package
Identification
Symbol
Lower Third
and Second
Number of
TC Number
on Rating
Plate
SERIAL
(Upper
Three
Numbers of
SERIAL)
6
PRE-OPERATION INSTRUCTIONS
z SERIAL number check
Refer to the inverter manual for the location of the rating plate.
Rating plate example
7 1 {{{{{{
SERIAL (Serial No.)
Symbol Year Month Control number
TC{{{A{{{G{{ TC number
The SERIAL consists of 1 version symbol, 2 numeric characters or 1 numeric character
and 1 alphabet letter indicating year and month, and 6 numeric characters indicating
control number.
Month is indicated as 1 to 9, X (October), Y (November), and Z (December).
Bar code
Input rating
71
Identification Symbol
Inverter Type
SERIAL (Serial No.)
The SERIAL (Serial No.) indicated on the
label of the product package consists of
six digits including the first three digits of
the control number and a symbol.
Label on the product package
7
PRE-OPERATION INSTRUCTIONS
1
1.2.1 Packing confirmation
Check the enclosed items.
Plug-in option
......................................... 1
Mounting screw (M3 × 6mm)
............ 2 (Refer to page 14.)
Hex-head screw for option
mounting (5.5mm)
............. 1 (Refer to page 14.)
FR-A7AP connection cable
............ 1 (Refer to page 15.)
Cable clamp
............ 4 (Refer to page 31.)
Cable tie
............ 4 (Refer to page 31.)
Microsoft and Windows are registered trademark or trademark of Microsoft Corporation in the United States and/or
other countries.
The formal name of Windows
®
2000 is Microsoft
®
Windows
®
2000 operating system.
The formal name of Windows
®
XP is Microsoft
®
Windows
®
XP operating system.
Company and product names herein are the trademarks or registered trademarks of their respective owners.
5.5mm
8
PRE-OPERATION INSTRUCTIONS
1.2.2 Parts
SW1
O
N
1
2
FR-A7NS_B
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
FR-A7NS
FR-A7NS_T
Switch for manufacturer
setting
Do not change from initially-
set status (1: ).
SSCNET III cable connector (CN1B)
Connect the following axis inverter or the servo amplifier.
For the final axis, puts a cap.
Shaft number switch
Set the shaft number.
FR-A7AP connector
Use this connector to connect to the FR-A7AP/
FR-A7AL. Connecting to the FR-A7AP/FR-A7AL
enables the inverter to receive encoder feedback
data.
SSCNET III cable connector (CN1A)
Connect the servo system controller, the preceding
axis inverter or the servo amplifier.
O
N
1
2
Front view Rear view
Mounting hole
Connector
Connect to the inverter option connector.
Mounting
hole
Mounting
hole
(Refer to page 26.)
(Refer to page 26.)
(Refer to page
15.)
(Refer to page 13.)
9
PRE-OPERATION INSTRUCTIONS
1
1.3 Caution
(1) Refer to the following manuals or software HELP for full information on the servo system controller.
y Q173DCPU/Q172DCPU user's manual ................................................... IB-0300133
y Q173DCPU/Q172DCPU motion controller (SV13/SV22)
programming manual (real mode version)................................................ IB-0300136
y Q173DCPU/Q172DCPU motion controller
programming manual (common mode version)........................................ IB-0300134
y Q173DCPU/Q172DCPU motion controller (SV13/SV22)
programming manual (Motion SFC version)............................................. IB-0300135
y Q173DCPU/Q172DCPU motion controller (SV22)
programming manual (virtual mode version)............................................ IB-0300137
(2) Servo System Controller NETwork ΙΙΙ is abbreviated to SSCNET ΙΙΙ in this manual.
10
PRE-OPERATION INSTRUCTIONS
1.4 Operation Overview
In communication with the Mitsubishi servo system controller, the inverter operation (speed control or
position control or torque control under vector control with encoder) or monitoring can be performed from a
program on the servo system controller.
Application of optical communication method greatly improved the communication speed and noise
resistance of the SSCNET ΙΙΙ as compared with the conventional SSCNET. In addition, 50m of the
maximum wiring length between stations is realized.
Encoder
FR-A700
Torque command
Speed monitor/feedback pulse monitor
Emergency stop
output shutoff
IM
Speed command
Position
command
Current
monitor
FR-A7NS
FR-A7AP/
FR-A7AL
Position command
Speed command
Torque command
*2
Control command
Emergency stop
*1
Monitor data
Parameter
Servo system controller
*1 When the emergency stop signal is input, the inverter shuts off the output and the motor coasts.
*2 Please contact your sales representative when performing torque control.
Motion control
SSCNETΙΙΙ
interface
SSCNETΙΙΙ
interface
Encoder
interface
Position
control
Speed
control
Torque
control
*2
11
PRE-OPERATION INSTRUCTIONS
1
CAUTION
y Mounting both the FR-A7NS and FR-A7AP/FR-A7AL and performing vector control enables SSCNET ΙΙΙ
communication.
When operating the inverter with the FR-A7NS mounted and without FR-A7AP/FR-A7AL, option alarm
(E.OPT) occurs. (Refer to page 77.) Also option alarm (E.OPT) occurs when the FR-A7AP and FR-A7NS are not
connected with the FR-A7AP connection cable (the FR-A7AL and FR-A7NS are not connected with the FR-
A7NS connection cable) during a stop of the inverter. (Refer to page 77.) (In those conditions, however, option
fault (E.OPT) does not occur when Pr.800 Control method selection = "9" (vector control test operation) (refer to
page 49) or when Pr.499 SSCNET III operation selection = "9999" (operation invalid). (refer to page 42))
y An alarm such as overcurrent shut off (E.OC3) and position error large (E.OD) may occur depending on the
status of the motor current and droop pulses during inverter operation.
12
2 INSTALLATION
2.1 Pre-Installation Instructions
Make sure that the input power of the inverter is off.
CAUTION
With input power on, do not install or remove the plug-in option. Otherwise, the inverter and
plug-in option may be damaged.
For prevention of damage due to static electricity, touch nearby metal before touching this
product to eliminate static electricity from your body.
13
INSTALLATION
2
2.2 Shaft number Setting
ySetting with shaft number switch
Set the shaft number between "0H to FH" using shaft number switches on the FR-A7NS (refer to page 8).
The setting is reflected at the next power-on or inverter reset.
Set the arrow (×) of the corresponding switches to the number and alphabet to set a desired shaft
number.
No. Definition No. Definition
0 1st axis 8 9th axis
1 2nd axis 9 10th axis
2 3rd axis A 11th axis
3 4th axis B 12th axis
4 5th axis C 13th axis
5 6th axis D 14th axis
6 7th axis E 15th axis
7 8th axis F 16th axis
CAUTION
y Set the shaft number switch to the switch number (alphabet) position correctly. If
the switch is set between numbers, normal data communication can not be
made.
y You cannot set the same shaft number to other devices on the network. (Doing so disables proper
communication.)
y Set the inverter shaft number before switching on the inverter and do not change the setting while
power is on. Otherwise you may get an electric shock.
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
Initial status
Good
example
Bad
example
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
14
INSTALLATION
2.3 Installation Procedure
1)Remove the inverter front cover.
2)Mount the hex-head screw for option
mounting into the inverter screw hole
(on earth plate). (size 5.5mm,
tightening torque 0.56Nm to 0.75Nm)
3)Securely fit the connector of the plug-in
option to the inverter connector along
the guides.
4)Securely fix the both right and left sides
of the plug-in option to the inverter with
the accessory mounting screws.
(Tightening torque 0.33Nm to
0.40Nm) If the screw holes do not line-
up, the connector may not have been
plugged snugly. Check for loose
plugging.
REMARKS
y Remove a plug-in option after removing two screws on both left and right sides.
(The plug-in option is easily removed if the control circuit terminal block is removed before.)
4) Mounting
screws
Inverter side
option
connector
Screw hole for
option mounting
Screw hole for
option mounting
(on earth plate)
Hex-head screw
for option mounting
1)
2)
3)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87

Mitsubishi Electric FR-A7NS User manual

Category
Power adapters & inverters
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI