6
M Blower Motor Bearing Access and
Ventilation Hole
(Figure 7, 8 & 9)
1. Disconnect unit from power source and
allow to cool thoroughly before proceeding
with this service operation.
2. Remove top cover. Remove lexan panels,
merchandising panels and flourescent
bulb from area involved.
3. Remove 10 sheet metal screws securing
cover to air box assembly and remove
cover. (Figure 7)
4. Remove the 2 sheet metal screws secur-
ing blower motor to side of unit. (Figure
7)
5. Lift blower motor up and move away from
corner of unit. Do NOT disconnect any
wiring from motor.
6. CAUTION: To prevent debris from getting
into the food chamber, completely cover
warm air return hole in component plate
with a piece of duct tape. (Figure 8)
7. Using a hole saw or Greenly punch, place
a 2-1/8” diameter hole into side of unit as
shown in Figure 8.
8. IMPORTANT: REMOVE TAPE FROM
AIR RETURN HOLE and clean out any
debris from area before returning blower
motor to original position.
9. Return blower motor to original position
and reattach to side of unit. Replace air
box cover.
10. Remove the rubber plug in the blower
motor bearing and add 1 drop of SAE 20
non-detergent oil. Replace rubber plug.
(Figure 9)
11. Replace fluorescent bulb, lexan panels,
merchandising panels and top cover.
NOTE: PERIODIC LUBRICATION OF THE
BEARING IS NECESSARY. THIS SHOULD
BE INCLUDED WITH ANY PREVENTATIVE
MAINTENANCE PROGRAM.