Installing and removing a fan tray 风扇模块的安装与拆卸
Before installing the fan tray, make sure the airflow direction marked on the fan tray meets
the ventilation requirement of the installation site. 安装风扇模块前,请根据风扇模 块的风
向指示,确认气流方向和安装环境的通风要求一致。
The switch comes with the two fan tray slots empty. You must install two fan trays of the
same model on the switch. Do not power on the switch when no or only one fan tray is
installed.交换机出厂时两个风扇插槽均为空,为保证设备的正常散热,用户必须安装两个
相同型号的风扇模块,否则禁止交换机上电运行。
If both fan trays fail when the switch is operating, finish replacing the fan trays within 2
minutes.交换机运行过程中,如果两个风扇模块均出现故障,则必须在2分钟内完成故障风
扇模块的更换。
If one fan tray fails when the switch is operating, replace the fan tray within 24 hours when
the ambient temperature is below 27°C (80.6°F). Do not remove the failed fan tray before
replacement. Replace the failed fan tray immediately when the ambient temperature is
above 27°C (80.6°F).交换机运行过程中,如果一个风扇模块出现故
障,则当环境温度不高于27℃时,必须在24小时内完成故障风扇模块的更换,且更换前必
须保持故障风扇模块在位;当环境温度高于27℃时, 请立即进行更换。
Install a filler panel to the empty power module slot to ensure good ventilation and prevent
dust from entering the chassis.若电源模块插槽没有安装电源模块,请及时安装假面板,
以保证设备的良好通风散热并防止灰尘进入交换机。
The S6800-32Q adopts the front-to-back airflow design. You can choose different fan
trays to direct airflow from port side to power module side or from power module side to
port side for different installation sites.
S6800-32Q采用前后风道设计,通过配置不同的风扇模块,可提供“端口侧到电源侧”
和“电源侧到端口侧”两种气流方向,满足不同环境下的散热要求。
Airflow direction of the switch 交换机的风向设计
6
5
Uses the LSWM1HFANSC fan tray
采用LSWM1HFANSC风扇模块
Uses the LSWM1HFANSCB fan tray
采用LSWM1HFANSCB 风扇模块
Install and remove a power module 电源模块的安装与拆卸
Install a power module安装电源 Remove a power module拆卸电源
Install and remove a fan tray风扇模块的安装与拆卸
Install a fan tray安装风扇
Remove a fan tray拆卸风扇
Remove a filler panel 拆卸假面板
Install a filler panel 安装假面板
Install and remove a filler panel 假面板的安装与拆卸
1
2
1
2
1
2