Tripp Lite PDUMH15NET, PDUMH20NET Owner's manual

  • Hello! I am an AI chatbot trained to assist you with the Tripp Lite PDUMH15NET Owner's manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
1
Warranty
Registration
Register online today for a chance
to win a FREE Tripp Lite product!
www.tripplite.com/warranty
Owner’s Manual
PDUMH15NET/PDUMH20NET
Switched Rack PDU
120V, 50/60Hz AC Input and Output
1111 W. 35th Street, Chicago, IL 60609 USA
www.tripplite.com/support
Copyright © 2011 Tripp Lite. All rights reserved.
Important Safety Instructions 2
Installation 3
Features 5
Configuration and Operation 7
Technical Support 8
Warranty and Warranty Registration 8
Español 9
Français 17
201110148-93-3042.indb 1 11/9/2011 11:21:04 AM
2
Important Safety Instructions
SAVE THESE INSTRUCTIONS
This manual contains instructions and warnings that should be
followed during the installation, operation, and storage of this
product. Failure to heed these instructions and warnings may
affect the product warranty.
•ThePDUprovidesconvenientmultipleoutlets,butitDOESNOTprovidesurgeor
line noise protection for connected equipment.
•ThePDUisdesignedforindooruseonlyinacontrolledenvironmentawayfrom
excessmoisture,temperatureextremes,conductivecontaminants,dustordirect
sunlight.
•DonotconnectthePDUtoanungroundedoutletortoextensioncordsoradapters
that eliminate the connection to ground.
•ThepowerrequirementforeachpieceofequipmentconnectedtothePDUmust
not exceed the individual outlet’s load rating.
•ThetotalpowerrequirementforequipmentconnectedtothePDUmustnotexceed
themaximumloadratingforthePDU.
•DonotdrillintoorattempttoopenanypartofthePDUhousing.Therearenouser-
serviceablepartsinside.
•DonotattempttomodifythePDU,includingtheinputplugsandpowercables.
•DonotattempttousethePDUifanypartofitbecomesdamaged.
•DonotattempttomountthePDUtoaninsecureorunstablesurface.
•Neverattempttoinstallelectricalequipmentduringathunderstorm.
•Useofthisequipmentinlifesupportapplicationswherefailureofthisequipment
canreasonablybeexpectedtocausethefailureofthelifesupportequipmentorto
significantlyaffectitssafetyoreffectivenessisnotrecommended.Donotusethis
equipmentinthepresenceofaflammableanestheticmixturewithair,oxygenor
nitrous oxide.
201110148-93-3042.indb 2 11/9/2011 11:21:04 AM
1-1
1-2
1-3
C
B
A
C
C
A
A
B
B
3
Installation
Mounting the PDU
ThePDUsupportsfourprimarymountingconfigurations:1URack,0URack(Vertical),
WallandUnder-Counter.
Note: Regardless of configuration, the user must determine the fitness of hardware and procedures before
mounting. The PDU and included hardware are designed for common rack and rack enclosure types and may
not be appropriate for all applications. Exact mounting configurations may vary. Screws for attaching the
mounting brackets and cord retention shelf to the PDU are included. Use only the screws supplied by the
manufacturer or their exact equivalent (#6-32, 3/16" flat head).
1-1
1U Rack Mounting:Use3screws
A
to attach each of the 2 longer
mountingbrackets
B
tothePDU
asshown.YoucanmountthePDU
inarecessedpositionbyattaching
themountingbracketssothey
extendbeyondthefrontpanelof
thePDU.(Ifyouplantousethe
cordretentionshelf,attachthe
mountingbracketsinarecessed
position.)MountthePDUinthe
rackbyinserting4user-supplied
screws
C
through the mounting
brackets
B
and into the mounting
holesoftherackrails.
1-2
0U Rack Mounting: Use3screws
A
to attach each of the 2 shorter
mountingbrackets
B
tothePDU
asshown.MountthePDU
verticallybyinserting2ormore
user-suppliedscrews
C
through
themountingbrackets
B
and into
mountingpointsintherackor
rackenclosure.
1-3
Wall Mounting: Use3screws
A
to attach each of the 2 shorter
mountingbrackets
B
tothePDU
asshown.MountthePDUtothe
wallbyinserting2ormoreuser-
supplied screws
C
through the
mountingbrackets
B
and into
secure mounting points.
201110148-93-3042.indb 3 11/9/2011 11:21:05 AM
1-4
1-5
2-1
2-2
A
A
B
C
B
A
PDUMH20NET
4
Installation continued
1-4
Under-Counter Mounting:Use3
screws
A
to attach each of the 2
shortermountingbrackets
B
to
thePDUasshown.Mountthe
PDUunderthecounterby
inserting2ormoreuser-supplied
screws
C
through the mounting
brackets
B
and into secure
mounting points.
1-5
Cord Retention Shelf
Attachment (Optional): Use2
screws
A
to attach the cord
retention shelf
B
to the front
panelofthePDU.
Connecting the PDU
2-1
Connect Input Plug Adapters
(Optional – PDUMH20NET Only):
ThePDUincludesanadapterthat
convertsitsL5-20Plockinginput
plugtoastandard5-20Pinput
plug. Connecting this adapter is
optional.ThePDUwillfunction
normally without connecting this
adapter.
Note: The AC power source should not share a
circuit with a heavy electrical load (such as an air
conditioner or refrigerator).
2-2
Connect Input Power Cord
(PDUMH15NET and
PDUMH20NET): Connect the
input plug
A
toacompatible
sourceofACpower,suchasa
UPSsystem,PDUorutilityoutlet.
ThePDUshouldbeprovidedwith
over-currentprotection:
PDUMH15NETwithamaximum
15Abranch-ratedprotection
device;PDUMH20NETwitha
maximum20Abranch-rated
protection device.
201110148-93-3042.indb 4 11/9/2011 11:21:06 AM
2-3
2-3
PDUMH15NET
PDUMH20NET
A
A
B
B
C
C
5
Installation continued
2-3
Equipment Power Cord
Connection: Insertpowercords
intotheNEMA5-15Routput
receptacles
A
(PDUMH15NET)or
NEMA5-15/20Routput
receptacles
A
(PDUMH20NET).
TheLED
B
near each output
receptacle illuminates when the
receptacleisreadytodistribute
live AC power. The digital load
meter
C
will display the total
connected equipment load in
amps.
Networking the PDU
ForInstructionsonnetworkingthePDU,refertotheSNMPWEBCARDQuickStart
GuideontheincludedCD-ROM.
Features
AC Input Power Cord (Model PDUMH15NET): The cord
ispermanentlyattachedtothePDUandhasaNEMA
5-15Pplug.
AC Input Power Cord (Model PDUMH20NET): The cord
ispermanentlyattachedtothePDUandhasaNEMA
L5-20Plockingplug.
AC Input Adapter (Model PDUMH20NET): The adapter
convertsaNEMAL5-20PinputplugtoaNEMA5-20P
input plug.
NEMA 5-15R Output Receptacles (PDUMH15NET):
Duringnormaloperation,theoutputreceptaclesdistribute
AC power to connected equipment. When an outlet is
live,itsassociatedLEDilluminates.
Features
201110148-93-3042.indb 5 11/9/2011 11:21:09 AM
6
Features continued
NEMA 5-15/20R Output Receptacles (PDUMH20NET):
Duringnormaloperation,theoutputreceptaclesdistribute
AC power to connected equipment. When an outlet is
live,itsassociatedLEDilluminates.
Digital Load Meter (Ammeter): The total electrical
currentdrawnbyconnectedequipmentisdisplayedon
the meter in amperes.
Cord Retention Shelf:WhenattachedtothePDU,the
cord retention shelf provides secure attachment points for
theinputcordandconnectedequipmentcords.Usethe
includedcabletiestosecurethecordstotheshelf.
Longer Mounting Brackets: Usethesebracketsto
mountthePDUhorizontallyinastandardrackorrack
enclosure.Themountingdepthcanbeadjustedby
attachingthebracketstodifferentpositionsonthePDU.
Shorter Mounting Brackets: Usethesebracketsto
mountthePDUina0Urack,wallorunder-counter
configuration.
Factory Port: Theportisreservedforconfigurationby
factoryauthorizedpersonnelonly.Donotconnect
anything to the port.
PS/2 Port: UsethisporttoconnectaTrippLite
ENVIROSENSEenvironmentalsensortoprovideremote
temperature/humidity monitoring and a dry contact
interfacetocontrolandmonitoralarm,securityand
telecomdevices.ContactTrippLiteCustomerSupportat
(773)869-1234fororderinginformation.Note: Do not
connect a keyboard or mouse to this port.
201110148-93-3042.indb 6 11/9/2011 11:21:10 AM
A B
A
B
7
Features continued
Mini-DIN Serial Port: Usethisporttoprovideadirect
terminal connection to a computer with a terminal
emulationprogram.Aserialcable(partnumber73-1025)
isincludedwiththePDU.Ifyouneedtoordera
replacementcable,contactTrippLiteCustomerSupport
at(773)869-1234.
Ethernet Port: UsethisRJ-45jacktoconnectthePDU
tothenetworkwithastandardEthernetpatchcable.The
LinkLED
A
andStatusLED
B
indicate several operating
conditions,asshowninthetablebelow.This port is not
compatible with PoE (Power Over Ethernet) applications.
Network Operating Conditions
A
LinkLEDColor
Off NoNetworkConnection
FlashingAmber 100MbpsNetworkConnection
Flashing Green 10MbpsNetworkConnection
B
StatusLEDColor
Off CardNotInitialized
SteadyGreen CardInitializedandOperational
FlashingAmber Error-CardNotInitialized
Configuration and Operation
Remote Monitoring and Control
ThePDUprovidesremotemonitoring
A
,
outlet control
B
andmoreviaWeb
browser,telnetandSNMP-based
NetworkManagementSystems.For
moreinformationaboutconfiguration
andoperationofthePDUviathe
PowerAlertWebbrowserinterface,refer
totheSNMPWEBCARDUser'sGuide,
includedontheCD-ROMbundledwith
thePDU.
201110148-93-3042.indb 7 11/9/2011 11:21:11 AM
8
Technical Support
Website:www.tripplite.com/support•E-mail:[email protected]
Warranty and Warranty Registration
LIMITED WARRANTY
Sellerwarrantsthisproduct,ifusedinaccordancewithallapplicableinstructions,tobefreefromoriginaldefectsinmaterialand
workmanship for a period of 2 years from the date of initial purchase. If the product should prove defective in material or
workmanshipwithinthatperiod,Sellerwillrepairorreplacetheproduct,initssolediscretion.ServiceunderthisWarrantycanonly
beobtainedbyyourdeliveringorshippingtheproduct(withallshippingordeliverychargesprepaid)to:TrippLite,1111W.35th
Street, Chicago, IL 60609 USA. Seller will pay return shipping charges. Visit www.tripplite.com/support before sending any
equipmentbackforrepair.
THISWARRANTYDOESNOTAPPLYTONORMALWEARORTODAMAGERESULTINGFROMACCIDENT,MISUSE,ABUSEORNEGLECT.
SELLERMAKESNOEXPRESSWARRANTIESOTHERTHANTHEWARRANTYEXPRESSLYSETFORTHHEREIN.EXCEPTTOTHEEXTENT
PROHIBITEDBYAPPLICABLELAW,ALLIMPLIEDWARRANTIES,INCLUDINGALLWARRANTIESOFMERCHANTABILITYORFITNESS,
ARE LIMITEDINDURATIONTOTHE WARRANTY PERIODSETFORTH ABOVE; ANDTHISWARRANTY EXPRESSLYEXCLUDESALL
INCIDENTALANDCONSEQUENTIALDAMAGES.(Somestatesdonotallowlimitationsonhowlonganimpliedwarrantylasts,and
somestatesdonotallowtheexclusionorlimitationofincidentalorconsequentialdamages,sotheabovelimitationsorexclusions
maynotapplytoyou.ThisWarrantygivesyouspecificlegalrights,andyoumayhaveotherrightswhichvaryfromjurisdictionto
jurisdiction).
WARNING:Theindividualusershouldtakecaretodeterminepriortousewhetherthisdeviceissuitable,adequateorsafeforthe
useintended.Sinceindividualapplicationsaresubjecttogreatvariation,themanufacturermakesnorepresentationorwarranty
astothesuitabilityorfitnessofthesedevicesforanyspecificapplication.
WARRANTY REGISTRATION
Visitwww.tripplite.com/warrantytodaytoregisterthewarrantyforyournewTrippLiteproduct.You'llbeautomaticallyenteredinto
a drawing for a chance to win a FREE Tripp Lite product!*
*Nopurchasenecessary.Voidwhereprohibited.Somerestrictionsapply.Seewebsitefordetails.
FCC Notice, Class A
Thisdevicecomplieswithpart15oftheFCCRules.Operationissubjecttothefollowingtwoconditions:(1)Thisdevicemaynot
cause harmful interference, and (2) this device must accept any interference received, including interference that may cause
undesired operation.
Note:ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassAdigitaldevice,pursuanttopart15ofthe
FCCRules.Theselimitsaredesignedtoprovidereasonableprotectionagainstharmfulinterferencewhentheequipmentisoperated
inacommercialenvironment.Thisequipmentgenerates,uses,andcanradiateradiofrequencyenergyand,ifnotinstalledand
used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the
interference at his own expense. The user must use shielded cables and connectors with this equipment. Any changes or
modificationstothisequipmentnotexpresslyapprovedbyTrippLitecouldvoidtheuser’sauthoritytooperatethisequipment.
Regulatory Compliance Identification Numbers
Forthepurposeofregulatorycompliancecertificationsandidentification,yourTrippLiteproducthasbeenassignedauniqueseries
number. The series number can be found on the product nameplate label, along with all required approval markings and
information.Whenrequestingcomplianceinformationforthisproduct,alwaysrefertotheseriesnumber.Theseriesnumbershould
notbeconfusedwiththemarkingnameormodelnumberoftheproduct.
WEEE Compliance Information for Tripp Lite Customers and Recyclers (European Union)
UndertheWasteElectricalandElectronicEquipment(WEEE)Directiveandimplementingregulations,whencustomersbuynew
electricalandelectronicequipmentfromTrippLitetheyareentitledto:
•Sendoldequipmentforrecyclingonaone-for-one,like-for-likebasis(thisvariesdependingonthecountry)
•Sendthenewequipmentbackforrecyclingwhenthisultimatelybecomeswaste
TrippLitefollowsapolicyofcontinuousimprovement.Specificationsaresubjecttochangewithoutnotice.
1111 W. 35th Street, Chicago, IL 60609 USA
www.tripplite.com/support
201110148•93-3042EN
201110148-93-3042.indb 8 11/9/2011 11:21:11 AM
9
Manual del propietario
PDUMH15NET/PDUMH20NET
PDU con tomas de corriente controlables para bastidor
120V, 50/60Hz AC Input y Output
1111 W. 35th Street, Chicago, IL 60609 USA
www.tripplite.com/support
© 2011 Tripp Lite. Todos los derechos reservados.
Instrucciones de seguridad importantes 10
Instalación 11
Características 13
Configuración y operación 15
Soporte técnico 16
Garantía 16
English 1
Français 17
201110148-93-3042.indb 9 11/9/2011 11:21:11 AM
/