Flashing Dots & LED Displayed
Turn breaker off then on again to reset the system.
If 3 flashing dots and LED disappear, wait until they are displayed again on keypad.
Power may remain On.
c- If error condition persists, re-
place probe (if replaceable only)
and reset breaker
.
d- If problem is not solved, replace
Spa Pack. (Refer to "How to Re
-
place the Spa Pack" section of this
manual.)
3•
Proceed to following page if key-
pad display shows incorrect tem-
perature.
1•
Take water temperature with a
digital thermometer.
2• If keypad display shows correct
temperature:
a- Check if heater barrel feels hot.
If it's hot, verify if anything is
obstructing the flow of water
(closed valves or dirty filter).
b- If it's not, verify if hi-limit probe
is properly connected (check
probe only if replaceable).
Try to clean probe connector
pins. Even a small coating of film
may cause a bad connection.
Reconnect probe and reset
breaker.
The three flashing dots and LED error condition is related to the Hi-Limit
sensor or temperature probe.