Heat & Glo Cerona-36/42 User manual

Category
Fireplaces
Type
User manual
1Heat & Glo โ€ข Cerona-36, Cerona-42 โ€ข 2106-900 Rev. AF โ€ข 5/20
Ownerโ€™s Manual
Installation and Operation
DO NOT DISCARD THIS MANUAL
NOTICE
โ€ข Leave this manual with
party responsible for use
and operation.
DO NOT
DISCARD
โ€ข Important operating
and maintenance
instructions included.
โ€ข Read, understand and follow
these instructions for safe
installation and operation.
In the Commonwealth of Massachusetts installation must be
performed by a licensed plumber or gas ๎‚ฟtter.
See Table of Contents for location of additional Commonwealth
of Massachusetts requirements.
Model(s):
CERONA-36
CERONA-42
This appliance may be installed as an OEM
installation in manufactured home (USA
only) or mobile home and must be installed
in accordance with the manufacturerโ€™s
instructions and the Manufactured Home
Construction and Safety Standard, Title 24
CFR, Part 3280 in the United States, or the
Standard for Installation in Mobile Homes,
CAN/CSA Z240 MH Series, in Canada.
This appliance is only for use with the type(s)
of gas indicated on the rating plate. This
appliance is not convertible for use with other
gases, unless a certi๎‚ฟed kit is used.
โ€ข DO NOT store or use gasoline or other ๎ƒ€am-
mable vapors and liquids in the vicinity of this
or any other appliance.
โ€ข What to do if you smell gas
- DO NOT try to light any appliance.
- DO NOT touch any electrical switch. DO
NOT use any phone in your building.
- Leave the building immediately.
- Immediately call your gas supplier from
a neighborโ€™s phone. Follow the gas sup-
plierโ€™s instructions.
- If you cannot reach your gas supplier, call
the ๎‚ฟre department.
โ€ข Installation and service must be performed
by a quali๎‚ฟed installer, service agency, or the
gas supplier.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death, or
property damage.
DANGER
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
A barrier designed to reduce the risk of
burns from the hot viewing glass is provided
with this appliance and must be installed for
the protection of children and other at-risk
individuals.
๏ƒจ
Heat & Glo โ€ข Cerona-36, Cerona-42 โ€ข 2106-900 Rev. AF โ€ข 5/202
Listing Label Information/Location
Model Name: ___________________________________________ Date purchased/installed: __________________
Serial Number: __________________________________________ Location on ๎‚ฟreplace: _____________________
Dealership purchased from: _______________________________ Dealer Phone: __________________________
Notes: _______________________________________________________________________________________
_____________________________________________________________________________________________
A. Congratulations
Congratulations on selecting a Heat & Glo gas ๎‚ฟreplace, an
elegant and clean alternative to wood burning ๎‚ฟreplaces.
The Heat & Glo gas ๎‚ฟreplace you have selected is designed
to provide the utmost in safety, reliability, and e๏‚ˆciency.
As the owner of a new ๎‚ฟreplace, youโ€™ll want to read and
carefully follow all of the instructions contained in this
ownerโ€™s manual. Pay special attention to all cautions and
warnings.
This ownerโ€™s manual should be retained for future
reference. We suggest that you keep it with your other
important documents and product manuals.
The information contained in this ownerโ€™s manual, unless
noted otherwise, applies to all models and gas control
systems.
Your new Heat & Glo gas ๎‚ฟreplace will give you years of
durable use and trouble-free enjoyment. Welcome to the
Heat & Glo family of ๎‚ฟreplace products!
We recommend that you record the following pertinent
information about your ๎‚ฟreplace.
Gas and Electric
Information
Serial Number
Type of Gas
The model information regarding your speci๎‚ฟc ๎‚ฟreplace can be found on
the rating plate usually located in the control area of the ๎‚ฟreplace.
Homeowner Reference Information
Model Number
Not Not for for use use with with solid solid fuel.fuel.
((Ne Ne doit doit pas pas entre entre utilise utilise avec avec un un combustible combustible solide).solide).
This This appliance appliance must must be be installed installed in in accordance accordance with with local local codes, codes, if if any; any; if if not, not, follow follow ANSI ANSI Z223.1Z223.1
in in the the USA USA or or CAN/CGA CAN/CGA B149 B149 installation installation codes. codes. (Installer (Installer lโ€™appareil lโ€™appareil selon selon les les codes codes ou ou reglementsreglements
locaux locaux ou, ou, en en lโ€™absence lโ€™absence de de tels tels reglements, reglements, selon selon les les codes codes dโ€™installation dโ€™installation CAN/CGA-B149.)CAN/CGA-B149.)
Type Type of of Gas Gas (Sorte (Sorte De De Gaz)Gaz)::
NNAATURALTURAL GASGAS
MADE MADE IN IN USAUSA
Minimum Minimum Permissible Permissible Gas Gas Supply Supply for for Purposes Purposes of of Input Input Adjustment.Adjustment.
Approved Approved Minimum Minimum (De (De Gaz) Gaz) AcceptableAcceptable0.00.0 in in w.c.w.c. (Po. (Po. Col. Col. dโ€™eau)dโ€™eau)
Maximum Maximum Pressure Pressure (Pression)(Pression) 0.00.0 in in w.c.w.c. (Po. (Po. Col. Col. dโ€™eau)dโ€™eau)
Maximum Maximum Manifold Manifold Pressure Pressure (Pression)(Pression) 0.00.0 in in w.c.w.c. (Po. (Po. Col. Col. dโ€™eau)dโ€™eau)
Minimum Minimum Manifold Manifold Pressure Pressure (Pression)(Pression) 0.00.0 in in w.c.w.c. (Po. (Po. Col. Col. dโ€™eau)dโ€™eau)
Model:Model:
(Modele):(Modele):
SerialSerial
(Serie):(Serie):
ANSI ANSI Z21XX-XXXX Z21XX-XXXX ยท ยท CSA CSA 2.XX-MXX 2.XX-MXX
XXXXXXXXXXXXXXXX
IN IN CANADACANADA
ALTITUDE:ALTITUDE:0-0000 0-0000 FT.FT.0000-0000FT.0000-0000FT.
MAX. MAX. INPUT INPUT BTUH:BTUH: 00,00000,000 00,00000,000
MIN. MIN. INPUT INPUT BTUH:BTUH: 00,00000,000 00,00000,000
ORIFICE ORIFICE SIZE:SIZE: #XXXXX#XXXXX #XXXXX#XXXXX XXXXXXXXXXXXXXXX
Total Total Electrical Electrical Requirements: Requirements: 000Vac, 000Vac, 00Hz., 00Hz., less less than than 00 00 AmperesAmperes
Heat & Glo, a brand of Hearth & Home Technologies
7571 215th Street West, Lakeville, MN 55044
Read this manual before installing or operating this appliance.
Please retain this ownerโ€™s manual for future reference.
3Heat & Glo โ€ข Cerona-36, Cerona-42 โ€ข 2106-900 Rev. AF โ€ข 5/20
Safety Alert Key:
โ€ข DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury.
โ€ข WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury.
โ€ข CAUTION! Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
โ€ข NOTICE: Used to address practices not related to personal injury.
Note: The term โ€œrecommendโ€ or โ€œrecommendedโ€ does not indicate a requirement. It is a best practice suggested by
Hearth & Home Technologiesยฎ.
Table of Contents
A. Congratulations .................................2
B. Limited Lifetime Warranty ..........................5
1 Listing and Code Approvals
A. Appliance Certi๎‚ฟcation ............................7
B. Glass Speci๎‚ฟcations .............................. 7
C. BTU Speci๎‚ฟcations ............................... 7
D. High Altitude Installations .......................... 7
E. Non-Combustible Materials Speci๎‚ฟcation. . . . . . . . . . . . . . 7
F. Combustible Materials Speci๎‚ฟcation ................. 7
G. Electrical Codes .................................7
H. California ......................................7
I. Requirements for the Commonwealth of Massachusetts ..8
User Guide
2 Operating Instructions
A. Gas Fireplace Safety .............................9
B. Your Fireplace .................................10
C. Fan Kit .......................................10
D. Clear Space ...................................10
E. Decorative Doors and Fronts ......................10
F. Fixed Glass Assembly ........................... 10
G. Remote Controls, Wall Controls and Wall Switches ..... 10
H. Before Lighting Fireplace .........................10
I. Lighting Instructions (IPI) ......................... 11
J. After Fireplace is Lit ............................. 12
K. Frequently Asked Questions ......................12
3 Maintenance and Service
A. Maintenance Tasks-Homeowner ...................13
B. Maintenance Tasks-Quali๎‚ฟed Service Technician ......14
Installer Guide
4 Getting Started
A. Typical Appliance System. . . . . . . . . . . . . . . . . . . . . . . . . 16
B. Design and Installation Considerations ..............17
C. Tools and Supplies Needed .......................17
D. Inspect Appliance and Components ................. 17
5 Framing and Clearances
A. Selecting Appliance Location ......................18
B. Constructing the Appliance Chase .................. 19
C. Clearances ....................................19
D. Mantel and Wall Projections ....................... 20
E. Hearth Extension ...............................21
6 Termination Locations
A. Vent Termination Minimum Clearances ..............22
7 Vent Information and Diagrams
A. Approved Pipe .................................24
B. Vent Table Key .................................24
C. Use of Elbows .................................24
D. Measuring Standards ............................24
E. Adding Vent Components. . . . . . . . . . . . . . . . . . . . . . . . . 25
F. Install Support Brackets ..........................26
8 Vent Clearances and Framing
A. Pipe Clearances to Combustibles .................. 30
B. Wall Penetration Framing ......................... 30
C. Install the Ceiling Firestop ........................31
D. Install Attic Insulation Shield ....................... 31
E. Installing the Optional Heat-Zoneยฎ Gas Kit ...........32
9 Appliance Preparation
A. Removing Non-combustible Facing Material Assembly .. 33
B. Securing and Leveling the Appliance ................ 33
C. Installing Non-combustible Facing Material ...........34
D. Installing Flue Restrictors ......................... 35
10 Installing Vent Pipe (DVP Pipe)
A. Assemble Vent Sections (DVP Pipe Only) ............36
B. Assemble Slip Sections ..........................37
C. Secure the Vent Sections ......................... 37
D. Disassemble Vent Sections .......................38
E. Install Decorative Ceiling Components .............. 38
F. Install Metal Roof Flashing ........................ 39
G. Assemble and Install Storm Collar ..................39
H. Install Vertical Termination Cap ....................40
I. Heat Shield Requirements for Horizontal Termination ...40
J. Install Horizontal Termination Cap ..................41
11 Gas Information
A. Fuel Conversion ................................42
B. Gas Pressure ..................................42
C. Gas Connection ................................42
D. High Altitude Installations ......................... 42
12 Electrical Information
A. Wiring Requirements ............................43
B. Connecting to the Appliance. . . . . . . . . . . . . . . . . . . . . . . 43
C. IntelliFireยฎ Ignition System Wiring .................. 43
D. Optional Accessories Requirements ................ 43
E. Electrical Service and Repair ......................43
๏ƒจ
๏ƒจ
Heat & Glo โ€ข Cerona-36, Cerona-42 โ€ข 2106-900 Rev. AF โ€ข 5/204
๏ƒจ = Contains updated information.
13 Finishing
A. Splatter Guard .................................45
B. Mantel Projections ..............................46
C. Facing Material .................................47
D. Finishing Material Options ........................48
E. Hearth Extension ...............................49
14 Appliance Setup
A. Remove Fixed Glass Assembly .................... 50
B. Remove the Shipping Materials ....................50
C. Inspect Firebox .................................50
D. Clean the Appliance ............................. 50
E. Accessories ...................................50
F. Ember Placement ...............................50
G. Positioning the Logs ............................. 51
H. Fixed Glass Assembly ...........................55
I. Grilles and Trim ................................ 55
J. Air Shutter Setting ..............................56
K. Install Mesh ...................................56
L. Install Trim and/or Surround ....................... 56
15 Troubleshooting
A. Intelli๎‚ฟre Ignition System ......................... 57
16 Reference Materials
A. Appliance/Decorative Front Dimension Diagrams ......59
B. Vent Components Diagrams ......................61
C. Service Parts ..................................68
D. Contact Information .............................72
5Heat & Glo โ€ข Cerona-36, Cerona-42 โ€ข 2106-900 Rev. AF โ€ข 5/20
B. Limited Lifetime Warranty
Hearth & Home Technologies
LIMITED LIFETIME WARRANTY
Hearth & Home Technologies, on behalf of its hearth brands (โ€œHHTโ€), extends the following warranty for HHT gas, wood, pellet and
electric hearth appliances that are purchased from an HHT authorized dealer.
WARRANTY COVERAGE:
HHT warrants to the original owner of the HHT appliance at the site of installa๎†Ÿon, and to any transferee taking ownership of the
appliance at the site of installa๎†Ÿon within two years following the date of original purchase, that the HHT appliance will be free from
defects in materials and workmanship at the ๎†Ÿme of manufacture. A๎…Œer installa๎†Ÿon, if covered components manufactured by HHT
are found to be defec๎†Ÿve in materials or workmanship during the applicable warranty period, HHT will, at its op๎†Ÿon, repair or replace
the covered components. HHT, at its own discre๎†Ÿon, may fully discharge all of its obliga๎†Ÿons under such warran๎†Ÿes by replacing the
product itself or refunding the veri๎„ฎed purchase price of the product itself. The maximum amount recoverable under this warranty
is limited to the purchase price of the product. This warranty is subject to condi๎†Ÿons, exclusions and limita๎†Ÿons as described below.
WARRANTY PERIOD:
Warranty coverage for consumers begins at the date of installa๎†Ÿon. In the case of new home construc๎†Ÿon, warranty coverage begins
on the date of ๎„ฎrst occupancy of the dwelling or six months a๎…Œer the sale of the product by an independent, authorized HHT dealer/
distributor, whichever occurs earlier. However, the warranty shall commence no later than 24 months following the date of product
shipment from HHT, regardless of the installa๎†Ÿon or occupancy date. The warranty period for parts and labor for covered components
is produced in the following table.
The term โ€œLimited Life๎†Ÿmeโ€ in the table below is de๎„ฎned as: 20 years from the beginning date of warranty coverage for gas appliances,
and 10 years from the beginning date of warranty coverage for wood and pellet appliances. These ๎†Ÿme periods re๎…‡ect the minimum
expected useful lives of the designated components under normal opera๎†Ÿng condi๎†Ÿons.
Page 1 of 2
4021-645K 1/20
Parts Labor Gas Pellet Wood Electric Venting Components Covered
X X
Igniters, Auger Motors, Electronic Components, and
Glass
X
Electrical components limited to modules, remotes/wall
switches, valves, pilots, blowers, junction boxes, wire
harnesses, transformers and lights (excluding light bulbs)
X X Molded Refractory Panels, Glass Liners
XVent Free Burners, Vent Free Logs
X X Castings, Medallions and Baffles
6 years 3 years XCatalyst - Limitations Listed
7 years 3 years X X Manifold tubes, HHT Chimney and Terminations
10 years 1 year XBurners, logs and refractory
Limited
Lifetime 3 years X X X Firebox and heat exchanger, FlexBurnยฎ System
(engine, inner cover,access cover and fireback)
1 Year None XXXXXAll replacement parts beyond warranty period
Warranty Period HHT Manufactured Appliances and Venting
All parts including handles, external enamaled
components and other material except as covered by
Conditions, Exclusions, and Limitations listed
2 years
3 years X
X1 Year X X X X
5 years 1 year
Firepots, burnpots, mechanical feeders/auger
assemblies
See conditions, exclusions and limitations on the next page
๏ƒจ
Heat & Glo โ€ข Cerona-36, Cerona-42 โ€ข 2106-900 Rev. AF โ€ข 5/206
B. Limited Lifetime Warranty (continued)
WARRANTY CONDITIONS:
โ€ข This warranty only covers HHT appliances that are purchased through an HHT authorized dealer or distributor. A list of HHT
authorized dealers is available on the HHT branded websites.
โ€ข This warranty is only valid while the HHT appliance remains at the site of original installa๎†Ÿon.
โ€ข This warranty is only valid in the country in which the HHT authorized dealer or distributor that sold the appliance resides.
โ€ข Contact your installing dealer for warranty service. If the installing dealer or distributor is unable to provide necessary parts,
contact the nearest HHT authorized dealer or supplier. Addi๎†Ÿonal service fees may apply if you are seeking warranty service from
a dealer other than the dealer from whom you originally purchased the product.
โ€ข Check with your dealer in advance for any costs to you when arranging a warranty call. Travel and shipping charges for parts are not
covered by this warranty.
โ€ข Limited Catalyst Warranty
o For wood burning products containing a catalyst, the catalyst will be warranted for a six-year period to the original purchaser at
the site of original installa๎†Ÿon. The purchaser must provide the name, address, and telephone number of the loca๎†Ÿon where
the product is installed, proof of original purchase date, date of failure, and any relevant informa๎†Ÿon regarding the failure of the
catalyst.
WARRANTY EXCLUSIONS:
This warranty does not cover the following:
โ€ข Changes in surface ๎„ฎnishes as a result of normal use. As a hea๎†Ÿng appliance, some changes in color of interior and exterior surface
๎„ฎnishes may occur. This is not a ๎…‡aw and is not covered under warranty.
โ€ข Damage to printed, plated, or enameled surfaces caused by ๎„ฎngerprints, accidents, misuse, scratches, melted items, or other
external sources and residues le๎…Œ on the plated surfaces from the use of abrasive cleaners or polishes.
โ€ข Repair or replacement of parts that are subject to normal wear and tear during the warranty period are not covered. These parts
include: paint, wood and pellet gaskets, ๎„ฎrebricks, grates, ๎…‡ame guides, ba๎†ฉeries and the discolora๎†Ÿon of glass.
โ€ข Expansion, contrac๎†Ÿon, or movement of certain parts causing noise. These condi๎†Ÿons are normal and complaints related to this
noise are not covered by this warranty.
โ€ข Damages resul๎†Ÿng from: (1) failure to install, operate, or maintain the appliance in accordance with the installa๎†Ÿon instruc๎†Ÿons,
opera๎†Ÿng instruc๎†Ÿons, and lis๎†Ÿng agent iden๎†Ÿ๎„ฎca๎†Ÿon label furnished with the appliance; (2) failure to install the appliance in
accordance with local building codes; (3) shipping or improper handling; (4) improper opera๎†Ÿon, abuse, misuse, con๎†Ÿnued opera๎†Ÿon
with damaged, corroded or failed components, accident, or improperly/incorrectly performed repairs (5) environmental condi๎†Ÿons,
inadequate ven๎†Ÿla๎†Ÿon, nega๎†Ÿve pressure, or dra๎…Œing caused by ๎†Ÿghtly sealed construc๎†Ÿons, insu๎„ธcient make-up air supply, or
handling devices such as exhaust fans or forced air furnaces or other such causes; (6) use of fuels other than those speci๎„ฎed in
the opera๎†Ÿon instruc๎†Ÿons; (7) installa๎†Ÿon or use of components not supplied with the appliance or any other components not
expressly authorized and approved by HHT; (8) modi๎„ฎca๎†Ÿon of the appliance not expressly authorized and approved by HHT in
wri๎†Ÿng; and/or (9) interrup๎†Ÿons or ๎…‡uctua๎†Ÿons of electrical power supply to the appliance.
โ€ข Non-HHT ven๎†Ÿng components, hearth connec๎†Ÿons or other accessories used in conjunc๎†Ÿon with the appliance.
โ€ข Any part of a pre-exis๎†Ÿng ๎„ฎreplace system in which an insert or a decora๎†Ÿve gas appliance is installed.
โ€ข
HHTโ€™s obliga๎†Ÿon under this warranty does not extend to the applianceโ€™s capability to heat the desired space. Informa๎†Ÿon is provided
to assist the consumer and the dealer in selec๎†Ÿng the proper appliance for the applica๎†Ÿon. Considera๎†Ÿon must be given to the
appliance loca๎†Ÿon and con๎„ฎgura๎†Ÿon, environmental condi๎†Ÿons, insula๎†Ÿon and air ๎†Ÿghtness of the structure.
This warranty is void if:
โ€ข The appliance has been over-๎„ฎred, operated in atmospheres contaminated by chlorine, ๎…‡uorine, or other damaging chemicals.
Over-๎„ฎring can be iden๎†Ÿ๎„ฎed by, but not limited to, warped plates or tubes, deforma๎†Ÿon/warping of interior cast iron structure or
components, rust colored cast iron, bubbling, cracking and discolora๎†Ÿon of steel or enamel ๎„ฎnishes.
โ€ข The appliance is subjected to prolonged periods of dampness or condensa๎†Ÿon.
โ€ข There is any damage to the appliance or other components due to water or weather damage which is the result of, but not limited
to, improper chimney or ven๎†Ÿng installa๎†Ÿon.
LIMITATIONS OF LIABILITY
โ€ข The ownerโ€™s exclusive remedy and HHTโ€™s sole obliga๎†Ÿon under this warranty, under any other warranty, express or implied, or in
contract, tort or otherwise, shall be limited to replacement, repair, or refund, as speci๎„ฎed above. In no event will HHT be liable for
any incidental or consequen๎†Ÿal damages caused by defects in the appliance. Some states do not allow exclusions or limita๎†Ÿon of
incidental or consequen๎†Ÿal damages, so these limita๎†Ÿons may not apply to you. This warranty gives you speci๎„ฎc rights; you may also
have other rights, which vary from state to state. EXCEPT TO THE EXTENT PROVIDED BY LAW, HHT MAKES NO EXPRESS WARRANTIES
OTHER THAN THE WARRANTY SPECIFICED HEREIN. THE DURATION OF ANY IMPLIED WARRANTY IS LIMITED TO DURATION OF THE
EXPRESSED WARRANTY SPECIFIED ABOVE.
Page 2 of 2
4021-645K 1/20
๏ƒจ
7Heat & Glo โ€ข Cerona-36, Cerona-42 โ€ข 2106-900 Rev. AF โ€ข 5/20
C.๎€ƒ BTU๎€ƒSpeci๎‚ฟcations
This product is listed to ANSI standards for โ€œVented Gas
Fireplace Heatersโ€ and applicable sections of โ€œGas Burn-
ing Heating Appliances for Manufactured Homes and
Recreational Vehiclesโ€, and โ€œGas Fired Appliances for
Use at High Altitudesโ€.
A.๎€ƒ Appliance๎€ƒCerti๎‚ฟcation
E.๎€ƒ Non-Combustible๎€ƒMaterials๎€ƒSpeci๎‚ฟcation
Material which will not ignite and burn. Such materials are
those consisting entirely of steel, iron, brick, tile, concrete,
slate, glass or plasters, or any combination thereof.
Materials that are reported as passing ASTM E 136,
Standard Test Method for Behavior of Materials in
a Vertical Tube Furnace at 750 ยบC shall be considered
non-combustible materials.
F.๎€ƒ Combustible๎€ƒMaterials๎€ƒSpeci๎‚ฟcation
Materials made of or surfaced with wood, compressed pa-
per, plant ๎‚ฟbers, plastics, or other material that can ignite
and burn, whether ๎ƒ€ame proofed or not, or plastered or
unplastered shall be considered combustible materials.
G. Electrical Codes
NOTICE: This appliance must be electrically wired
and grounded in accordance with local codes or, in the
absence of local codes, with National Electric Code
ANSI/NFPA 70-latest edition or the Canadian Electric
Code CSA C22.1.
โ€ข A 110-120 VAC circuit for this product must be pro-
tected with ground-fault circuit-interrupter protection,
in compliance with the applicable electrical codes,
when it is installed in locations such as in bathrooms
or near sinks.
H. California
NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.
This appliance is tested and approved as either supplemen-
tal room heat or as a decorative appliance. It should not be
factored as primary heat in residential heating calculations.
D. High Altitude Installations
NOTICE: If the heating value of the gas has been reduced,
these rules do not apply. Check with your local gas utility
or authorities having jurisdiction.
When installing above 2000 feet elevation:
โ€ข In the USA: Reduce input rate 4% for each 1000 feet
above 2000 feet.
โ€ข In CANADA: Reduce input rate 10% for elevations
between 2000 feet and 4500 feet. Above 4500 feet,
consult local gas utility.
Check with your local gas utility to determine proper
ori๎‚ฟce size.
NOTICE: This installation must conform with local codes.
In the absence of local codes you must comply with the
National Fuel Gas Code, ANSI Z223.1-latest edition in
the U.S.A. and the CAN/CGA B149 Installation Codes in
Canada.
1 1 Listing and Code Approvals
B.๎€ƒ Glass๎€ƒSpeci๎‚ฟcations
This appliance is equipped with 5 mm ceramic glass. Re-
place glass only with 5 mm ceramic glass. Please contact
your dealer for replacement glass.
MODELS: CERONA-36, CERONA-42
LABORATORY: Underwriters Laboratories, Inc. (UL)
TYPE: Direct Vent Heater
STANDARD: CSA / ANSI Z21.88:19 โ€ข CSA 2.33:19
Model
(U.S. or Canada)
Maximum
Input BTU/h
Minimum
Input BTU/h
Ori๎‚ฟce๎€ƒ
Size
(DMS)
Cerona-36 (NG)
US
(0-2000 FT) 37,500 25,000 32
CAN
(2000-4500 FT) 33,750 22,300 33
Cerona-42 (NG)
US
(0-2000 FT) 48,000 32,000 29
CAN
(2000-4500 FT) 40,500 28,800 30
Cerona-36
(PROPANE)
US
(0-2000 FT) 36,500 23,000 50
CAN
(2000-4500 FT) 32,850 20,700 51
Cerona-42
(PROPANE)
US
(0-2000 FT) 42,000 27,000 48
CAN
(2000-4500 FT) 37,800 25,200 49
WARNING: This product and the fuels used to
operate this product (liquid propane or natural
gas), and the products of combustion of such fuels, can
expose you to chemicals including benzene, which is
known to the State of California to cause cancer and
reproductive harm. For more information go to: www.
P65Warnings.ca.gov.
๏ƒจ
Heat & Glo โ€ข Cerona-36, Cerona-42 โ€ข 2106-900 Rev. AF โ€ข 5/208
I. Requirements for the Commonwealth of
Massachusetts
For all side wall horizontally vented gas fueled equipment
installed in every dwelling, building or structure used in
whole or in part for residential purposes, including those
owned or operated by the Commonwealth and where the
side wall exhaust vent termination is less than seven (7)
feet above ๎‚ฟnished grade in the area of the venting, in-
cluding but not limited to decks and porches, the following
requirements shall be satis๎‚ฟed:
Installation of Carbon Monoxide Detectors
At the time of installation of the side wall horizontal vented
gas fueled equipment, the installing plumber or gas ๎‚ฟtter
shall observe that a hard wired carbon monoxide detector
with an alarm and battery back-up is installed on the ๎ƒ€oor
level where the gas equipment is to be installed. In addi-
tion, the installing plumber or gas ๎‚ฟtter shall observe that
a battery operated or hard wired carbon monoxide detec-
tor with an alarm is installed on each additional level of
the dwelling, building or structure served by the side wall
horizontal vented gas fueled equipment. It shall be the
responsibility of the property owner to secure the services
of quali๎‚ฟed licensed professionals for the installation of
hard wired carbon monoxide detectors.
In the event that the side wall horizontally vented gas fu-
eled equipment is installed in a crawl space or an attic,
the hard wired carbon monoxide detector with alarm and
battery back-up may be installed on the next adjacent
๎ƒ€oor level.
In the event that the requirements of this subdivision can
not be met at the time of completion of installation, the
owner shall have a period of thirty (30) days to comply
with the above requirements; provided, however, that dur-
ing said thirty (30) day period, a battery operated carbon
monoxide detector with an alarm shall be installed.
Approved Carbon Monoxide Detectors
Each carbon monoxide detector as required in accor-
dance with the above provisions shall comply with NFPA
720 and be ANSI/UL 2034 listed and IAS certi๎‚ฟed.
Signage
A metal or plastic identi๎‚ฟcation plate shall be permanent-
ly mounted to the exterior of the building at a minimum
height of eight (8) feet above grade directly in line with the
exhaust vent terminal for the horizontally vented gas fu-
eled heating appliance or equipment. The sign shall read,
in print size no less than one-half (1/2) in. in size, โ€œGAS
VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OB-
STRUCTIONSโ€.
Inspection
The state or local gas inspector of the side wall horizon-
tally vented gas fueled equipment shall not approve the
installation unless, upon inspection, the inspector ob-
serves carbon monoxide detectors and signage installed
in accordance with the provisions of 248 CMR 5.08(2)(a)1
through 4.
Exemptions
The following equipment is exempt from 248 CMR
5.08(2)(a)1 through 4:
โ€ข The equipment listed in Chapter 10 entitled โ€œEquipment
Not Required To Be Ventedโ€ in the most current edition
of NFPA 54 as adopted by the Board; and
โ€ข Product Approved side wall horizontally vented gas fu-
eled equipment installed in a room or structure separate
from the dwelling, building or structure used in whole or
in part for residential purposes.
MANUFACTURER REQUIREMENTS
Gas Equipment Venting System Provided
When the manufacturer of Product Approved side wall
horizontally vented gas equipment provides a venting
system design or venting system components with the
equipment, the instructions provided by the manufacturer
for installation of the equipment and the venting system
shall include:
โ€ข Detailed instructions for the installation of the venting
system design or the venting system components; and
โ€ข A complete parts list for the venting system design or
venting system.
Gas Equipment Venting System NOT Provided
When the manufacturer of a Product Approved side wall
horizontally vented gas fueled equipment does not pro-
vide the parts for venting the ๎ƒ€ue gases, but identi๎‚ฟes
โ€œspecial venting systemsโ€, the following requirements
shall be satis๎‚ฟed by the manufacturer:
โ€ข The referenced โ€œspecial venting systemโ€ instructions
shall be included with the appliance or equipment in-
stallation instructions; and
โ€ข The โ€œspecial venting systemsโ€ shall be Product Ap-
proved by the Board, and the instructions for that sys-
tem shall include a parts list and detailed installation
instructions.
A copy of all installation instructions for all Product Ap-
proved side wall horizontally vented gas fueled equip-
ment, all venting instructions, all parts lists for venting
instructions, and/or all venting design instructions shall
remain with the appliance or equipment at the completion
of the installation.
See Gas Connection section for additional Common-
wealth of Massachusetts requirements.
Note: The following requirements reference various
Massachusetts and national codes not contained in this
document.
9Heat & Glo โ€ข Cerona-36, Cerona-42 โ€ข 2106-900 Rev. AF โ€ข 5/20
Figure 2.1 General Operating Parts
DECORATIVE DOORS
(NOT SHOWN)
SECTION 2.E.
FIXED GLASS ASSEMBLY
(NOT SHOWN)
SECTION 14.J.
GRATE
SECTION 2.B.
MANTEL
HEARTH
FAN KIT
SECTION 2.C
CLEAR SPACE
SECTION 2.D.
A. Gas Fireplace Safety
2 2 Operating Instructions
User Guide
Young children should be carefully supervised when they
are in the same room as the appliance. Toddlers, young
children and others may be susceptible to accidental
contact burns.
โ€ข A physical barrier is recommended if there are at risk
individuals in the house.
โ€ข To restrict access to a ๎‚ฟreplace or stove, install an
adjustable safety gate to keep toddlers, young children
and other at risk individuals out of the room and away
from hot surfaces.
โ€ข Install a switch lock or a wall/remote control with child
protection lockout feature.
โ€ข Keep remote controls out of reach of children.
โ€ข Never leave children alone near a hot ๎‚ฟreplace, whether
operating or cooling down.
โ€ข Teach children to NEVER touch the ๎‚ฟreplace.
โ€ข Consider not using the ๎‚ฟreplace when children will be
present.
Contact your dealer for more information, or visit: www.
hpba.org/Product-Info/Fireplace-Stove-Heater/Glass-
Fronts-Safety.
To prevent unintended operation when not using your ๎‚ฟre-
place for an extended period of time (summer months,
vacations, trips, etc):
โ€ข Remove batteries from remote controls.
โ€ข Turn o๏‚‡ wall controls.
โ€ข Unplug 3 volt adapter plug and remove batteries on IPI
models.
WARNING! DO NOT operate ๎‚ฟreplace before reading
and understanding operating instructions. Failure
to operate ๎‚ฟreplace according to operating instructions
could cause ๎‚ฟre or injury.
A barrier designed to reduce the risk of burns from the
hot viewing glass is provided with this appliance and
must be installed for the protection of children and other
at-risk individuals. DO NOT operate the appliance with
the barrier removed. If the barrier becomes damaged,
the barrier must be replaced with the manufacturerโ€™s
barrier for this appliance.
Contact your dealer or Hearth & Home Technologies if the
barrier is not present or help is needed to properly install one.
DANGER
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
โ€ข Keep children away.
โ€ข CAREFULLY SUPERVISE children in same room
as ๎‚ฟreplace.
โ€ข Alert children and adults to hazards of high
temperatures.
High temperatures may ignite clothing or other
๎ƒ€ammable๎€ƒmaterials.
โ€ข Clothing, furniture, draperies, and other ๎ƒ€ammable
materials must not be placed on or near the
appliance.
๏ƒจ
๏ƒจ
Heat & Glo โ€ข Cerona-36, Cerona-42 โ€ข 2106-900 Rev. AF โ€ข 5/2010
D. Clear Space
WARNING! DO NOT place combustible objects in front
of the ๎‚ฟreplace or block louvers. High temperatures may
start a ๎‚ฟre. See Figure 2.2.
Avoid placing candles and other heat-sensitive objects on
mantel or hearth. Heat may damage these objects.
Figure 2.2 Clear Space
C. Fan Kit
A fan is shipped with this appliance.
F. Fixed Glass Assembly
See Section 14.G.
E. Decorative Doors and Fronts
WARNING! Risk of Fire! Install ONLY doors or fronts
approved by Hearth & Home Technologies. Unapproved
doors or fronts may cause ๎‚ฟreplace to overheat.
This fireplace has been supplied with an integral
barrier to prevent direct contact with the ๎‚ฟxed glass
panel. DO NOT operate the ๎‚ฟreplace with the barrier
removed.
Contact your dealer or Hearth & Home Technologies if
the barrier is not present or help is needed to properly
install one.
For more information refer to the instructions supplied with
your decorative door or front.
G. Remote Controls, Wall Controls and Wall
Switches
Follow the instructions supplied with the control installed
to operate your ๎‚ฟreplace:
For safety:
โ€ข Install a switch lock or a wall/remote control with child
protection lockout feature.
โ€ข Keep remote controls out of reach of children.
See your dealer if you have questions.
CLEAR SPACE
3 FT. IN FRONT OF FIREPLACE
H. Before Lighting Fireplace
Before operating this ๎‚ฟreplace for the ๎‚ฟrst time, have a
quali๎‚ฟed๎€ƒservice๎€ƒtechnician:
โ€ข Verify all shipping materials have been removed from
inside and/or underneath the ๎‚ฟrebox.
โ€ข Review proper placement of logs, ember material and/or
other decorative materials.
โ€ข Check the wiring.
โ€ข Check the air shutter adjustment.
โ€ข Ensure that there are no gas leaks.
โ€ข Ensure that the glass is sealed and in the proper position
and that the integral barrier is in place.
WARNING! Risk of Fire or Asphyxiation! DO NOT op-
erate ๎‚ฟreplace with ๎‚ฟxed glass assembly removed.
B. Your Fireplace
WARNING! DO NOT operate ๎‚ฟreplace before read-
ing and understanding operating instructions. Failure
to operate ๎‚ฟreplace according to operating instructions
could cause ๎‚ฟre or injury.
11Heat & Glo โ€ข Cerona-36, Cerona-42 โ€ข 2106-900 Rev. AF โ€ข 5/20
I. Lighting Instructions (IPI)
The IPI system may be operated with two D-cell batteries. When using batteries, unplug the transformer. To prolong battery
life, remove them when using the transformer.
FOR YOUR SAFETY READ BEFORE LIGHTING
TO TURN OFF GAS TO APPLIANCE
1. This appliance is equipped with an ignition device which
automatically lights the burner. DO NOT try to light the burner by hand.
1. Equipped with wall switch: Turn ON/OFF switch to OFF.
Equipped with remote or wall control: Press OFF button.
Equipped with thermostat: Set temperature to lowest setting.
WARNING
WARNING:
NOT FOR USE WITH SOLID FUEL
GAS
VALVE
For additional information on operating your
refer to www.hearthnhome.com.
A. This appliance is equipped with an intermittent pilot ignition (IPI) device which
automatically lights the burner. DO NOT try to light the burner by hand.
B. BEFORE LIGHTING, smell all around the appliance area for gas. Be sure to smell
WHAT TO DO IF YOU SMELL GAS
โ€ขDO NOT try to light any appliance.
โ€ขDO NOT touch any electric switch; do not use any phone in your building.
DO NOT CONNECT LINE VOLTAGE (110/120 VAC OR 220/240 VAC) TO THE CON-
TROL VALVE.
Improper installation, adjustment, alteration, service or maintenance can cause injury
or property damage. Refer to the ownerโ€™s information manual provided with this ap-
agency or the gas supplier.
This appliance needs fresh air for safe operation and must be installed so there are
provisions for adequate combustion and ventilation air.
Hot while in operation. DO NOT touch. Keep children, clothing, furniture, gasoline
DO NOT operate the appliance with removed, cracked or
broken. Replacement of the should be done by a licensed or
โ€ข Immediately call your gas supplier from a neighborโ€™s phone. Follow the gas sup-
plierโ€™s instructions.
โ€ข
C. Use only your hand to push in or turn the gas control knob. Never use tools. If
the knob will not push in or turn by hand, DO NOT
D. DO NOT use this appliance if any part has been under water. Immediately call
the control system and any gas control which has been under water.
For use with natural gas and propane. A conversion kit, as supplied by the manufac-
turer, shall be used to convert this appliance to the alternate fuel.
This appliance must be installed in accordance with local codes, if any; if none,
follow the National Fuel Gas Code, ANSIZ223.1/ NFPA 54, or the National Gas and
Propane Installation code, CSA B149.1.
LIGHTING INSTRUCTIONS (IPI)
2.
top of this label. If you do not smell gas, go to next step.
3. To light the burner:
Equipped with wall switch: Turn ON/OFF switch to ON.
Equipped with remote or wall control: Press ON or FLAME button.
Equipped with thermostat: Set temperature to desired setting.
4. If the appliance does not light after three tries, call your service technician or gas
supplier.
2. Service technician should turn off electric power to the control when performing
service.
DANGER
HOT GLASS WILL CAUSE BURNS.
DO NOT TOUCH GLASS UNTIL COOLED.
NEVER ALLOW CHILDREN TO TOUCH GLASS.
CAUTION:
A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this
appliance and shall be installed for the protection of children and other at-risk individuals.
WARNING: This product and the fuels used to operate this
product (liquid propane or natural gas), and the products
of combustion of such fuels, can expose you to chemicals
including benzene, which is known to the State of California to cause
cancer and reproductive harm. For more information go to: www.
P65Warnings.ca.gov.
Keep burner and control compartment clean. See installation and operating instructions
accompanying appliance.
Heat & Glo โ€ข Cerona-36, Cerona-42 โ€ข 2106-900 Rev. AF โ€ข 5/2012
J. After Fireplace is Lit
Initial Break-in Procedure
โ€ข The fireplace should be run three to four hours
continuously on high.
โ€ข Turn the ๎‚ฟreplace o๏‚‡ and allow it to completely cool.
โ€ข Remove ๎‚ฟxed glass assembly. See Section 14.G.
โ€ข Clean ๎‚ฟxed glass assembly. See Section 3.
โ€ข Replace the ๎‚ฟxed glass assembly and run continuously
on high an additional 12 hours.
This cures the materials used to manufacture the ๎‚ฟre-
place.
NOTICE! Open windows for air circulation during ๎‚ฟre-
place break-in.
โ€ข Some people may be sensitive to smoke and odors.
โ€ข Smoke detectors may activate.
K. Frequently Asked Questions
ISSUE SOLUTIONS
Condensation on the glass This is a result of gas combustion and temperature variations. As the ๎‚ฟreplace warms, this
condensation will disappear.
Blue ๎ƒ€ames This is a result of normal operation and the ๎ƒ€ames will begin to yellow as the ๎‚ฟreplace is al-
lowed to burn for 20 to 40 minutes.
Odor from ๎‚ฟreplace
When ๎‚ฟrst operated, this ๎‚ฟreplace may release an odor for the ๎‚ฟrst several hours. This is caused
by the curing of the paint and the burning o๏‚‡ of any oils remaining from manufacturing. Odor may
also be released from ๎‚ฟnishing materials and adhesives used around the ๎‚ฟreplace.
Film on the glass
This is a normal result of the curing process of the paint and logs. Glass should be cleaned
within 3 to 4 hours of initial burning to remove deposits left by oils from the manufacturing
process. A non-abrasive cleaner such as gas ๎‚ฟreplace glass cleaner may be necessary. See
your dealer.
Metallic noise
Noise is caused by metal expanding and contracting as it heats up and cools down, similar to
the sound produced by a furnace or heating duct. This noise does not a๏‚‡ect the operation or
longevity of the ๎‚ฟreplace.
Is it normal to see the pilot ๎ƒ€ame burn
continually?
In an intermittent pilot ignition system (IPI), the pilot ๎ƒ€ame should turn o๏‚‡ when appliance is
turned o๏‚‡. Some optional control systems available with IPI models may allow pilot ๎ƒ€ame to
remain lit.
13Heat & Glo โ€ข Cerona-36, Cerona-42 โ€ข 2106-900 Rev. AF โ€ข 5/20
Glass Cleaning
Frequency: Seasonally
By: Homeowner
Tools Needed: Protective gloves, glass cleaner, drop
cloth and a stable work surface.
CAUTION! Handle ๎‚ฟxed glass assembly with care.
Glass is breakable.
โ€ข Avoid striking, scratching or slamming glass
โ€ข Avoid abrasive cleaners
โ€ข DO NOT clean glass while it is hot
โ€ข Prepare a work area large enough to accommodate ๎‚ฟxed
glass assembly and door frame by placing a drop cloth
on a ๎ƒ€at, stable surface.
Note: Fixed glass assembly and gasketing may have res-
idue that can stain carpeting or ๎ƒ€oor surfaces.
โ€ข Remove door or decorative front from ๎‚ฟreplace and set
aside on work surface.
โ€ข See Section 14.G for instructions to remove ๎‚ฟxed glass
assembly.
โ€ข Clean glass with a non-abrasive commercially available
cleaner.
- Light deposits: Use a soft cloth with soap and water
- Heavy deposits: Use commercial fireplace glass
cleaner (consult with your dealer)
โ€ข Carefully set ๎‚ฟxed glass assembly in place on ๎‚ฟreplace.
Hold glass in place with one hand and secure glass
latches with the other hand.
3 3 Maintenance and Service
A. Maintenance Tasks-Homeowner
The following tasks may be performed annually by the
homeowner. If you are uncomfortable performing any of
the listed tasks, please call your dealer for a service ap-
pointment.
More frequent cleaning may be required due to lint from
carpeting or other factors. Control compartment, burner
and circulating air passageway of the ๎‚ฟreplace must be
kept clean.
CAUTION! Risk of Burns! The ๎‚ฟreplace should be turned
o๎ฏบ and cooled before servicing.
When properly maintained, your ๎‚ฟreplace will give you
many years of trouble-free service. We recommend an-
nual service by a quali๎‚ฟed service technician. Doors, Surrounds, Fronts
Frequency: Annually
By: Homeowner
Tools needed: Protective gloves, stable work surface
โ€ข Assess condition of screen and replace as necessary.
โ€ข Inspect for scratches, dents or other damage and repair
as necessary.
โ€ข Check that louvers are not blocked.
โ€ข Vacuum and dust surfaces.
Remote Control
Frequency: Seasonally
By: Homeowner
Tools needed: Replacement batteries and remote con-
trol instructions.
โ€ข Locate remote control transmitter and receiver.
โ€ข Verify operation of remote. Refer to remote control
operation instructions for proper calibration and setup
procedure.
โ€ข Place batteries as needed in remote transmitters and
battery-powered receivers.
โ€ข Place remote control out of reach of children.
If not using your ๎‚ฟreplace for an extended period of time
(summer months, vacations/trips, etc), to prevent unin-
tended operation:
โ€ข Remove batteries from remote controls.
โ€ข Unplug 3 volt adapter plug on IPI models.
Any safety screen or guard removed for servicing must be
replaced prior to operating the ๎‚ฟreplace.
Installation and repair should be done by a quali๎‚ฟed service
technician only. The ๎‚ฟreplace should be inspected before
use and at least annually by a professional service person.
โ€ข Inspect and operate all glass latches to ensure they
move freely and no obstructions are present.
โ€ข Reinstall door or decorative front.
Heat & Glo โ€ข Cerona-36, Cerona-42 โ€ข 2106-900 Rev. AF โ€ข 5/2014
Venting
Frequency: Seasonally
By: Homeowner
Tools needed: Protective gloves and safety glasses.
โ€ข Inspect venting and termination cap for blockage or
obstruction such as plants, bird nests, leaves, snow,
debris, etc.
โ€ข Verify termination cap clearance to subsequent construc-
tion (building additions, decks, fences, or sheds). See
Section 6.
โ€ข Inspect for corrosion or separation.
โ€ข Verify weather stripping, sealing and ๎ƒ€ashing remains
intact.
โ€ข Inspect draft shield to verify it is not damaged or missing.
B.๎€ƒ Maintenance๎€ƒTasks-Quali๎‚ฟed๎€ƒService๎€ƒ
Technician
The following tasks must be performed by a quali๎‚ฟed ser-
vice technician.
Gasket Seal and Glass Assembly Inspection
Frequency: Annually
By: Quali๎‚ฟed Service Technician
Tools needed: Protective gloves, drop cloth and a stable
work surface.
โ€ข Inspect gasket seal and its condition.
โ€ข Inspect ๎‚ฟxed glass assembly for scratches and nicks that
can lead to breakage when exposed to heat.
โ€ข Con๎‚ฟrm there is no damage to glass or glass frame.
Replace as necessary.
โ€ข Verify that ๎‚ฟxed glass assembly is properly retained and
attachment components are intact and not damaged.
Replace as necessary.
Logs
Frequency: Annually
By: Quali๎‚ฟed Service Technician
Tools needed: Protective gloves.
โ€ข Inspect for damaged or missing logs. Replace as neces-
sary. Refer to Section 14 for log placement instructions.
โ€ข Verify correct log placement and no ๎ƒ€ame impingement
causing sooting. Correct as necessary.
Control Compartment and Firebox Top
Frequency: Annually
By: Quali๎‚ฟed Service Technician
Tools needed: Protective gloves, vacuum cleaner, dust
cloths
โ€ข Vacuum and wipe out dust, cobwebs, debris or pet hair.
Use caution when cleaning these areas. Screw tips that
have penetrated the sheet metal are sharp and should
be avoided.
โ€ข Remove all foreign objects.
โ€ข Verify unobstructed air circulation.
Burner Ignition and Operation
Frequency: Annually
By: Quali๎‚ฟed Service Technician
Tools needed: Protective gloves, vacuum cleaner, whisk
broom, ๎ƒ€ashlight, voltmeter, indexed drill bit set, and a
manometer.
โ€ข Verify burner is properly secured and aligned with pilot
or igniter.
โ€ข Clean o๏‚‡ burner top, inspect for plugged ports, corrosion
or deterioration. Replace burner if necessary.
โ€ข Replace Glowing embers with new dime-size pieces.
DO NOT block ports or obstruct lighting paths. Refer to
Section 14 for proper ember placement.
โ€ข Verify batteries have been removed from battery back-
up IPI systems to prevent premature battery failure or
leaking.
โ€ข Check for smooth lighting and ignition carryover to all
ports. Verify that there is no ignition delay. Inspect and
ensure the lighting of the main burner occurs within four
seconds of the main gas valve opening.
โ€ข Inspect for lifting or other ๎ƒ€ame problems.
โ€ข Verify air shutter setting is correct. See Section 14 for
required air shutter setting. Verify air shutter is clear of
dust and debris.
โ€ข Inspect ori๎‚ฟce for soot, dirt and corrosion. Verify ori๎‚ฟce
size is correct. See Service Parts List for proper ori๎‚ฟce
sizing.
โ€ข Verify manifold and inlet pressures. Adjust regulator as
required.
โ€ข Check all accessible gas-carrying tubes, connections,
pipes and other components for leaks.
โ€ข Inspect pilot ๎ƒ€ame pattern and strength. See Figure 3.1
for proper pilot ๎ƒ€ame pattern. Clean or replace ori๎‚ฟce
spud as necessary.
โ€ข Inspect IPI ๎ƒ€ame sensing rod for soot, corrosion and
deterioration. Polish with ๎‚ฟne steel wool or replace as
required.
โ€ข Verify that there is not a short in ๎ƒ€ame sense circuit
by checking continuity between pilot hood and ๎ƒ€ame
sensing rod. Replace pilot as necessary.
15Heat & Glo โ€ข Cerona-36, Cerona-42 โ€ข 2106-900 Rev. AF โ€ข 5/20
Figure 3.1 IPI Pilot Flame Patterns
Firebox
Frequency: Annually
By: Service Technician
Tools needed: Protective gloves, sandpaper, steel wool,
cloths, mineral spirits, primer and touch-up paint.
โ€ข Inspect for paint condition, warped surfaces, corrosion
or perforation. Sand and repaint as necessary.
โ€ข Replace appliance if ๎‚ฟrebox has been perforated.
Surface cracking or crazing of ๎‚ฟrebrick material is normal
and expected. All cracks are acceptable and do not require
replacement of the unit or the ๎‚ฟrebox with the exception of:
โ€ข Cracks compromising the surface plane of the ๎‚ฟrebox.
See Figure 3.2.
Figure๎€ƒ3.2.๎€ƒ๎€ƒSurface๎€ƒplane๎€ƒof๎€ƒ๎‚ฟrebox๎€ƒis๎€ƒcomprised๎€ƒ and๎€ƒ should๎€ƒ be๎€ƒ
replaced.
Heat & Glo โ€ข Cerona-36, Cerona-42 โ€ข 2106-900 Rev. AF โ€ข 5/2016
A. Typical Appliance System
NOTICE: Illustrations and photos re๎ƒ€ect typical installations and are for design purposes only. Illustrations/diagrams are not
drawn to scale. Actual product may vary from pictures in manual.
Figure 4.1 Typical System
CEILING FIRESTOP
ON FLOOR OF ATTIC
(SECTION 8.C. )
VERTICAL TERMINATION CAP
(SECTION 10.H. )
VENT PIPE PENETRATES ROOF
PREFERABLY WITHOUT AFFECTING
ROOF RAFTERS (SECTION 10.F.)
FRAMING HEADED OFF
IN CEILING JOISTS
(SECTION 8.B AND 8.C. )
GAS LINE
(SECTION 11.C)
MANTEL AND
MANTEL LEG
(SECTION 5.D.)
HEARTH EXTENSION
(SECTION 5.E.)
VENT PIPE (SECTIONS 7 and 8)
STORM COLLAR
(SECTION 10.G.)
NON-COMBUSTIBLE ROOF FLASHING
MAINTAINS MINIMUM CLEARANCE
AROUND PIPE (SECTION 10.F)
FRAMING/HEADER
(SECTION 5.B and 5.C.)
ATTIC INSULATION SHIELD (NOT SHOWN)
MUST BE USED HERE TO KEEP
INSULATION AWAY FROM VENT PIPE IF
ATTIC IS INSULATED (SECTION 8.D.)
4 4 Getting Started
Installer Guide
17Heat & Glo โ€ข Cerona-36, Cerona-42 โ€ข 2106-900 Rev. AF โ€ข 5/20
B. Design and Installation Considerations
Heat & Glo direct vent gas appliances are designed to
operate with all combustion air siphoned from outside of
the building and all exhaust gases expelled to the outside.
No additional outside air source is required.
Installation MUST comply with local, regional, state and
national codes and regulations. Consult insurance carrier,
local building inspector, ๎‚ฟre o๏‚ˆcials or authorities having
jurisdiction over restrictions, installation inspection and
permits.
Before installing, determine the following:
โ€ข Where the appliance is to be installed.
โ€ข The vent system con๎‚ฟguration to be used.
โ€ข Gas supply piping requirements.
โ€ข Electrical wiring requirements.
โ€ข Framing and ๎‚ฟnishing details.
โ€ข Whether optional accessoriesโ€”devices such as a fan,
wall switch, or remote controlโ€”are desired.
D. Inspect Appliance and Components
โ€ข Carefully remove the appliance and components from
the packaging.
โ€ข The vent system components and decorative doors and
fronts may be shipped in separate packages.
โ€ข If packaged separately, the log set and appliance grate
must be installed.
โ€ข Report to your dealer any parts damaged in shipment,
particularly the condition of the glass.
โ€ข Read all of the instructions before starting the instal-
lation. Follow these instructions carefully during the
installation๎€ƒto๎€ƒensure๎€ƒmaximum๎€ƒsafety๎€ƒand๎€ƒbene๎‚ฟt.
WARNING! Risk of Fire or Explosion! Damaged parts
could impair safe operation. DO NOT install damaged, in-
complete or substitute components. Keep appliance dry.
C. Tools and Supplies Needed
Before beginning the installation be sure that the following
tools and building supplies are available.
Tape measure Framing material
Pliers Hammer
Phillips screwdriver Manometer
Gloves Framing square
Voltmeter Electric drill and bits (1/4 in.)
Plumb line Safety glasses
Level Reciprocating saw
Flat blade screwdriver
Non-corrosive leak check solution
1/2 - 3/4 in. length, #6 or #8 Self-drilling screws
Caulking material (300 ยบF minimum continuous exposure
rating)
One 1/4 in. female connection (for optional fan).
Hearth & Home Technologies disclaims any responsibility for,
and the warranty will be voided by, the following actions:
โ€ข Installation and use of any damaged appliance or vent
system component.
โ€ข Modi๎‚ฟcation of the appliance or vent system.
โ€ข Installation other than as instructed by Hearth & Home
Technologies.
โ€ข Improper positioning of the gas logs or the glass door.
โ€ข Installation and/or use of any component part not approved
by Hearth & Home Technologies.
Any๎€ƒsuch๎€ƒaction๎€ƒmay๎€ƒcause๎€ƒa๎€ƒ๎‚ฟre๎€ƒhazard.
WARNING! Risk of Fire, Explosion or Electric Shock!
DO NOT use this appliance if any part has been under
water. Call a quali๎‚ฟed service technician to inspect the
appliance and to replace any part of the control system
and/or gas control which has been under water.
Improper installation, adjustment, alteration, service or
maintenance can cause injury or property damage. For
assistance or additional information, consult a quali๎‚ฟed
service technician, service agency or your dealer.
Installation and service of this appliance should be performed by
quali๎‚ฟed personnel. Hearth & Home Technologies recommends
HHT Factory Trained or NFI certi๎‚ฟed professionals.
Heat & Glo โ€ข Cerona-36, Cerona-42 โ€ข 2106-900 Rev. AF โ€ข 5/2018
ALCOVE
INSTALLATION
A
H
B
C
D
E
F
G
B
A
5 5 Framing and Clearances
A. Selecting Appliance Location
When selecting a location for the appliance it is important to
consider the required clearances to walls (see Figure 5.1).
WARNING! Risk of Fire or Burns! Provide adequate
clearance around air openings and for service access.
Due to high temperatures, the appliance should be locat-
ed out of tra๎ฏปc and away from furniture and draperies.
NOTICE: Illustrations re๎ƒ€ect typical installations and are
FOR DESIGN PURPOSES ONLY. Illustrations/diagrams
are not drawn to scale. Actual installation may vary due to
individual design preference.
Figure 5.1 Appliance Locations
In addition to these framing dimensions, also reference the following sections:
โ€ข Clearances and Mantel Projections (Sections 5.C, 5.D and 5.E)
โ€ข Vent Clearances and Framing (Section 8).
CERONA-36 A B C D E F G H
Inches 51 42-1/8 73-1/4 36 65-1/2 1/2 22-1/4 16
Millimeters 1295 1070 1861 914 1664 13 565 406
CERONA-42 A B C D E F G H
Inches 56-5/8 49-1/8 80-1/8 36 72-1/2 1/2 22-1/4 18-3/4
Millimeters 1438 1248 2035 914 1842 13 565 476
19Heat & Glo โ€ข Cerona-36, Cerona-42 โ€ข 2106-900 Rev. AF โ€ข 5/20
B. Constructing the Appliance Chase
A chase is a vertical box-like structure built to enclose the
gas appliance and/or its vent system. In cooler climates
the vent should be enclosed inside the chase.
NOTICE: Treatment of ceiling ๎‚ฟrestops and wall shield
๎‚ฟrestops and construction of the chase may vary with the
type of building. These instructions are not substitutes
for the requirements of local building codes. Therefore,
you MUST check local building codes to determine the
requirements to these steps.
NOTICE: When installing a sprinkler head in a ๎‚ฟreplace
chase, it is recommended to use a sprinkler head with a
sprinkler activation temperature classi๎‚ฟed as Extra High.
Keep sprinkler head away from vent and chimney.
Chases should be constructed in the manner of all out-
side walls of the home to prevent cold air drafting prob-
lems. The chase should not break the outside building
envelope in any manner.
Walls, ceiling, base plate and cantilever ๎ƒ€oor of the chase
should be insulated. Vapor and air in๎‚ฟltration barriers
should be installed in the chase as per regional codes for
the rest of the home. Additionally, in regions where cold
air in๎‚ฟltration may be an issue, the inside surfaces may be
sheetrocked and taped for maximum air tightness.
Figure 5.2 Clearances to Combustibles
C. Clearances
NOTICE: Install appliance on hard metal or wood surfaces
extending full width and depth. DO NOT install directly
on carpeting, vinyl, tile or any combustible material other
than wood.
WARNING! Risk of Fire! Maintain speci๎‚ฟed air space
clearances to appliance and vent pipe:
โ€ข Insulation and other materials must be secured to prevent
accidental contact.
โ€ข The chase must be properly blocked to prevent blown
insulation or other combustibles from entering and
making contact with ๎‚ฟreplace or chimney.
โ€ข Failure to maintain airspace may cause overheating and
a ๎‚ฟre.
To further prevent drafts, the wall shield and ceiling ๎‚ฟre-
stops should be caulked with caulk with a minimum of 300
ยบF continuous exposure rating to seal gaps. Gas line holes
and other openings should be caulked with caulk with a
minimum of 300 ยบF continuous exposure rating or stu๏‚‡ed
with unfaced insulation. If the appliance is being installed
on a cement surface, a layer of plywood may be placed
underneath to prevent conducting cold up into the room.
A
B
C
D
F
G
H
J
I
E
CLEARANCES TO COMBUSTIBLES:
A B C D E F G H I J
Rough
Opening
(Vent Pipe)
Rough
Opening
(Height)
Rough
Opening
(Depth)
Rough
Opening
(Width)
Clearance to
Ceiling from Top
of Arch Opening
Combustible
Floor
Combustible
Flooring
Behind
Appliance
Sides of
Appliance
Front of
Appliance
Cerona-36 in 10 50-1/2 22-1/4 42-1/8 49 0 8 1/2 1/2 36
mm 254 1283 565 1070 1245 0 203 13 13 914
Cerona-42 in 10 54-1/2 22-1/4 49-1/8 45-1/4 0 8 1/2 1/2 36
mm 254 1384 565 1248 1149 0 203 13 13 914
Heat & Glo โ€ข Cerona-36, Cerona-42 โ€ข 2106-900 Rev. AF โ€ข 5/2020
D. Mantel and Wall Projections
WARNING! Risk of Fire! Comply with all minimum clear-
ances as speci๎‚ฟed. Framing or ๎‚ฟnishing material closer than
the minimums listed must be constructed entirely of non-
combustible materials (i.e., steel studs, concrete board, etc).
Figure 5.3 Clearances to mantels or other combustibles
above appliance
Figure 5.4 Clearances to Mantel Legs or Wall Projections
(Acceptable on both sides of opening.)
NON-COMBUSTIBLE
FACING MATERIAL
COMBUSTIBLE
FACING MATERIAL
1 in.
TYPICAL
D
MINIMUM
FROM TOP OF ARCH
OPENING TO FIRST
MANTEL PROJECTION
E
MINIMUM
FROM TOP OF ARCH
OPENING TO CEILING
FIREPLACE HEADER
1"
2"
3"
4"
5"
6"
7"
8"
9"
10"
11"
12"
TOP OF ARCH OPENING
CEILING
A
B
C
MAXIMUM
A B C D E
Cerona-36 in. 32-1/4 16-3/4 16 11 49
mm 819 425 406 279 1245
Cerona-42 in. 28-1/2 16-3/4 16 11 45-1/4
mm 724 425 406 279 1149
A
TOP VIEW
B
MANTEL LEG OR
WALL PROJECTIONS
INTERIOR WALL
If A minimum is _____, then B maximum is ______.
A
in. 1 2 3 4 5 6 7 8 9 10 11 12
mm 25 51 76 102 127 152 178 203 229 254 279 305
B
in. 1 2 3 4 5 6 7 8 9 10 11
โˆž
mm 25 51 76 102 127 152 178 203 229 254 279
โˆž
A B C
Cerona-36 in. 49 16-3/4 43-5/8
mm 1245 425 1108
Cerona-42 in. 45-1/4 16-3/4 50-5/8
mm 1149 425 1286
Note: If using the Apollo Mantel System, the appliance must
be raised 1-1/4 in. from ๎ƒ€oor.
A
B
1 in.
(25)
C
CEILING
COMBUSTIBLE
SHEATHING
NON-COMBUSTIBLE
FACING MATERIAL
IN SHADED AREAS
FIREPLACE
ARCH OPENING
CLEARANCE
TO CEILING
MINIMUM
BOTTOM OF FIREPLACE
TO BOTTOM OF
NON-COMBUSTIBLE
FACING MATERIAL
Figure 5.5
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68

Heat & Glo Cerona-36/42 User manual

Category
Fireplaces
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI