5
6
Ethernet Lighting control connection (not applicable
for 0-10 V)
0-10 V Lighting control connection (not applicable for
Ethernet)
6NatureConnect - Installation guide - February 2023
BRI
CG#
0-10V
0-10V
SCENE
NEUT
GND
CG#
+24V
234 5
1
Label Color Description
1BRI Blue Brightness 0-10V positive
2CG# Gray Brightness 0-10V negative
3SCENE Blue Scene select 0-10V positive
4CG# Gray Scene select 0-10V negative
5+24V Orange +24V (do not connect)
A cabinet uses either this 0-10V lighting control connection, or it
uses an Ethernet lighting control connetion. Refer to the lighting
plan to see which one applies.
Ethernet connection to lighting control system
Ethernet internal
A cabinet uses either this Ethernet lighting control connection, or it
uses a 0-10V lighting control connetion. Refer to the lighting plan to
see which one applies.
When using a Dynalite lighting control system, connect the Ethernet
internal port to the network port of a Dynalite PDEG.
Terminal block
inside cabinet