Supero SuperServer 5016I-MRF User manual

Category
Server barebones
Type
User manual

This manual is also suitable for

SUPER
SuperServer 5016I-MR
SuperServer 5016I-MRF
®
USER’S MANUAL
Revision 1.0b
The information in this User’s Manual has been carefully reviewed and is believed to be accurate.
The vendor assumes no responsibility for any inaccuracies that may be contained in this document,
makes no commitment to update or to keep current the information in this manual, or to notify any
person or organization of the updates. Please Note: For the most up-to-date version of this
manual, please see our web site at www.supermicro.com.
Super Micro Computer, Inc. ("Supermicro") reserves the right to make changes to the product
described in this manual at any time and without notice. This product, including software and docu-
mentation, is the property of Supermicro and/or its licensors, and is supplied only under a license.
Any use or reproduction of this product is not allowed, except as expressly permitted by the terms
of said license.
IN NO EVENT WILL SUPERMICRO BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL,
SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OR INABILITY TO
USE THIS PRODUCT OR DOCUMENTATION, EVEN IF ADVISED OF THE POSSIBILITY OF
SUCH DAMAGES. IN PARTICULAR, SUPERMICRO SHALL NOT HAVE LIABILITY FOR ANY
HARDWARE, SOFTWARE, OR DATA STORED OR USED WITH THE PRODUCT, INCLUDING THE
COSTS OF REPAIRING, REPLACING, INTEGRATING, INSTALLING OR RECOVERING SUCH
HARDWARE, SOFTWARE, OR DATA.
Any disputes arising between manufacturer and customer shall be governed by the laws of Santa
Clara County in the State of California, USA. The State of California, County of Santa Clara shall
be the exclusive venue for the resolution of any such disputes. Super Micro's total liability for all
claims will not exceed the price paid for the hardware product.
FCC Statement: This equipment has been tested and found to comply with the limits for a Class A
digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a commercial environ-
ment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the manufacturer’s instruction manual, may cause harmful interference
with radio communications. Operation of this equipment in a residential area is likely to cause harmful
interference, in which case you will be required to correct the interference at your own expense.
California Best Management Practices Regulations for Perchlorate Materials: This Perchlorate warn-
ing applies only to products containing CR (Manganese Dioxide) Lithium coin cells. “Perchlorate
Material-special handling may apply. See www.dtsc.ca.gov/hazardouswaste/perchlorate”
WARNING: Handling of lead solder materials used in this
product may expose you to lead, a chemical known to the
State of California to cause birth defects and other repro-
ductive harm.
Manual Revision 1.0b
Release Date: December 21, 20121
Unless you request and receive written permission from Super Micro Computer, Inc., you may not
copy any part of this document.
Information in this document is subject to change without notice. Other products and companies
referred to herein are trademarks or registered trademarks of their respective companies or mark
holders.
Copyright © 2012 by Super Micro Computer, Inc.
All rights reserved.
Printed in the United States of America
Preface
About This Manual
This manual is written for professional system integrators and PC technicians. It
provides information for the installation and use of the SuperServer 5016I-MR/5016I-
MRF. Installation and maintenance shall be performed by experienced technicians
only.
The SuperServer 5016I-MR/5016I-MRF is a single processor system based on the
SC512-200mini-tower chassis and the Super X8SIL/X8SIL-F motherboard.
Manual Organization
Chapter 1: Introduction
The rst chapter provides a checklist of the main components included with the
system and describes the main features of the Super X8SIL/X8SIL-F motherboard
and the SC512-200chassis.
Chapter 2: Installation
This chapter describes the steps necessary to setup the system. If your server was
ordered without the processor and memory components, this chapter will refer you
to the appropriate sections of the manual for their installation.
Chapter 3: System Interface
Refer to this chapter for details on the system interface, which includes the functions
and information provided by the control panel on the chassis as well as other LEDs
located throughout the system.
Chapter 4: System Safety
You should thoroughly familiarize yourself with this chapter for a general overview
of safety precautions that should be followed when installing and servicing the
SuperServer 5016I-MR/5016I-MRF.
iii
Preface
iv
Chapter 5: Advanced Motherboard Setup
Chapter 5 provides detailed information on the X8SIL/X8SIL-F motherboard, in-
cluding the locations and functions of connectors, headers and jumpers. Refer
to this chapter when adding or removing processors or main memory and when
recon guring the motherboard.
Chapter 6: Advanced Chassis Setup
Refer to Chapter 6 for detailed information on the SC512-200 chassis. You should
follow the procedures given in this chapter when installing, removing or recon gur-
ing Serial ATA or peripheral drives and when replacing system power supply units
and cooling fans.
Chapter 7: BIOS
The BIOS chapter includes an introduction to BIOS and provides detailed informa-
tion on running the CMOS Setup Utility.
Appendix A: POST Error Beep Codes
Appendix B: Installing Windows
Appendix C: System Speci cations
SUPERSERVER 5016I-MR/5016I-MRF User's Manual
v
Preface
Notes
vi
Table of Contents
Chapter 1 Introduction
1-1 Overview .........................................................................................................1-1
1-2 Motherboard Features .....................................................................................1-2
Processors ......................................................................................................1-2
Memory ...........................................................................................................1-2
Serial ATA .......................................................................................................1-2
PCI Expansion Slots .......................................................................................1-2
I/O Ports .......................................................................................................... 1-2
Other Features ................................................................................................ 1-2
1-3 Server Chassis Features ................................................................................1-3
System Power ................................................................................................. 1-3
Serial ATA Subsystem .....................................................................................1-3
Control Panel .................................................................................................. 1-3
Rear I/O Panel ................................................................................................1-3
Cooling System ............................................................................................... 1-3
1-4 Contacting Supermicro ....................................................................................1-5
Chapter 2 Server Installation
2-1 Overview .........................................................................................................2-1
2-2 Unpacking the System ....................................................................................2-1
2-3 Preparing for Setup .........................................................................................2-1
Choosing a Setup Location ............................................................................. 2-1
2-4 Warnings and Precautions .............................................................................. 2-2
Rack Precautions ............................................................................................ 2-2
Server Precautions ..........................................................................................2-2
Rack Mounting Considerations .......................................................................2-3
Ambient Operating Temperature ................................................................2-3
Reduced Air ow .........................................................................................2-3
Mechanical Loading ...................................................................................2-3
Circuit Overloading .....................................................................................2-3
Reliable Ground ......................................................................................... 2-3
2-5 Installing the System into a Rack ................................................................... 2-4
Basic Installation Procedure ...........................................................................2-4
Installing with Rackmount Kit .......................................................................... 2-4
Installing the Chassis Rails .............................................................................2-5
Installing the Rack Rails .................................................................................2-5
Installing the Server into the Rack .................................................................. 2-6
SUPERSERVER 5016I-MR/5016I-MRF User's Manual
vii
Table of Contents
Installing the Server into a Telco Rack ...........................................................2-7
2-6 Checking the Motherboard Setup ................................................................... 2-8
2-7 Checking the Drive Bay Setup ...................................................................... 2-10
Chapter 3 System Interface
3-1 Overview .........................................................................................................3-1
3-2 Control Panel Buttons .....................................................................................3-1
Reset ...............................................................................................................3-1
Power ..............................................................................................................3-1
3-3 Control Panel LEDs ........................................................................................3-2
Overheat ..........................................................................................................3-2
NIC2 ................................................................................................................3-2
NIC1 ................................................................................................................3-2
HDD .................................................................................................................3-2
Power ..............................................................................................................3-3
Chapter 4 Standardized Warning Statements for AC Systems
4-1 About Standardized Warning Statements ....................................................... 4-1
Warning De nition ...........................................................................................4-1
Installation Instructions ....................................................................................4-4
Circuit Breaker ................................................................................................ 4-5
Power Disconnection Warning ........................................................................ 4-6
Equipment Installation ..................................................................................... 4-8
Restricted Area ................................................................................................ 4-9
Battery Handling ............................................................................................4-10
Redundant Power Supplies ..........................................................................4-12
Backplane Voltage ........................................................................................4-13
Comply with Local and National Electrical Codes ........................................ 4-14
Product Disposal ........................................................................................... 4-15
Hot Swap Fan Warning ................................................................................. 4-16
Power Cable and AC Adapter ...................................................................... 4-18
Chapter 5 Advanced Motherboard Setup
5-1 Handling the Motherboard ..............................................................................5-1
Precautions .....................................................................................................5-1
Unpacking .......................................................................................................5-1
5-2 Motherboard Installation ..................................................................................5-2
5-3 Connecting Cables ..........................................................................................5-2
Connecting Data Cables .................................................................................5-2
Connecting Power Cables ..............................................................................5-3
Connecting the Control Panel ......................................................................... 5-3
viii
5-4 I/O Ports ..........................................................................................................5-4
5-5 Processor and Heatsink Installation................................................................5-4
Installing the LGA1156 Processor .................................................................5-5
Installing a Passive CPU Heatsink ................................................................. 5-7
5-6 Installing Memory ............................................................................................ 5-9
DIMM Installation ............................................................................................5-9
Memory Support ..............................................................................................5-9
Memory Population Guidelines ..................................................................... 5-10
5-7 Installing PCI Add-On Cards ......................................................................... 5-12
5-8 Motherboard Details ......................................................................................5-13
5-9 Connector De nitions ...................................................................................5-15
Main ATX Power Supply Connector ......................................................... 5-15
Processor Power Connector .................................................................... 5-15
Power Button ...........................................................................................5-15
Reset Button ........................................................................................... 5-15
Overheat (OH)/Fan Fail ............................................................................ 5-16
NIC1/NIC2 (LAN1/LAN2) .......................................................................... 5-16
HDD LED ..................................................................................................5-16
Power On LED .........................................................................................5-16
Chassis Intrusion ...................................................................................... 5-17
ATX PS/2 Keyboard and PS/2 Mouse Ports ............................................ 5-17
Fan Headers .............................................................................................5-17
Onboard Speaker ..................................................................................... 5-17
Speaker ....................................................................................................5-18
Serial Ports ............................................................................................... 5-18
Universal Serial Bus (USB) ...................................................................... 5-18
LAN1/LAN2 (Ethernet Ports) .................................................................... 5-18
Onboard Power LED ................................................................................5-19
Power Supply I2C Connector....................................................................5-19
T-SGPIO 0/1 Headers ..............................................................................5-19
Alarm Reset ..............................................................................................5-19
5-10 Jumper Settings ............................................................................................5-20
Explanation of Jumpers ............................................................................5-20
CMOS Clear ............................................................................................. 5-20
VGA Enable .............................................................................................. 5-20
LAN1/LAN2 Enable/Disable ....................................................................5-21
PCI Slot SMB Enable ...............................................................................5-21
USB Wake-Up .........................................................................................5-21
SUPERSERVER 5016I-MR/5016I-MRF User's Manual
ix
BMC Jumper ............................................................................................ 5-21
5-11 Onboard Indicators ........................................................................................5-22
LAN1/2 LEDs ............................................................................................5-22
IPMI Dedicated LAN LEDs ..................................................................... 5-22
Onboard Power LED ............................................................................................................ 5-22
IPMI Heartbeat LED .................................................................................5-22
5-12 SATA and Floppy Drive Connections ............................................................5-23
SATA Ports ............................................................................................... 5-23
Floppy Connector ..................................................................................... 5-23
5-13 Installing Software .........................................................................................5-24
Super Doctor III ............................................................................................. 5-25
Chapter 6 Advanced Chassis Setup
6-1 Static-Sensitive Devices ..................................................................................6-1
Precautions .....................................................................................................6-1
Unpacking .......................................................................................................6-1
6-2 Control Panel ..................................................................................................6-2
6-3 System Fans ...................................................................................................6-3
System Fan Failure ......................................................................................... 6-3
6-4 Drive Bay Installation/Removal .......................................................................6-4
Accessing the Drive Bays ...............................................................................6-4
6-5 Power Supply .................................................................................................. 6-6
Power Supply Failure ......................................................................................6-6
Chapter 7 BIOS
7-1 Introduction ......................................................................................................7-1
Starting BIOS Setup Utility ..............................................................................7-1
How To Change the Con guration Data ......................................................... 7-1
How to Start the Setup Utility ......................................................................... 7-2
7-2 Main Setup ...................................................................................................... 7-2
7-3 Advanced Setup Con gurations......................................................................7-4
7-4 Security Settings ...........................................................................................7-19
7-5 Boot Settings ................................................................................................ 7-20
7-6 Exit Options ...................................................................................................7-21
Appendix A POST Error Beep Codes
Appendix B Installing Windows
Appendix C System Speci cations
Table of Contents
Notes
SUPERSERVER 5016I-MR/5016I-MRF User's Manual
x
Chapter 1
Introduction
1-1 Overview
The SuperServer 5016I-MR/5016I-MRF is 1U server comprised of two main sub-
systems: the SC512-200 mini 1U chassis and the X8SIL/X8SIL-F motherboard.
Please refer to our web site for information on operating systems that have been
certi ed for use with the SuperServer 5016I-MR/5016I-MRF (www.supermicro.com).
Note: a complete list of safety warnings is provided on the Supermicro web site at
http://www.supermicro.com/about/policies/safety_information.cfm
In addition to the motherboard and chassis, various hardware components have
been included with the SuperServer 5016I-MR/5016I-MRF, as listed below:
One cooling fan (FAN-0059L4)
One passive heatsink (SNK-P0046P)
One riser card (CSE-RR1U-E8)
SATA Accessories
One SATA cable (CBL-0061L)
One SuperServer 5016I-MR/5016I-MRF User's Manual
Optional
One slim DVD-ROM drive (DVM-LITE-DVDRW-SBT or DVM-PNSC-DVD-
SBT)
One DVD-ROM drive cable (CBL-0341L)
One DVD USB adapter (CDM-USATA-G)
Chapter 1: Introduction
1-1
1-2
SUPERSERVER 5016I-MR/5016I-MRF User's Manual
1-2 Motherboard Features
At the heart of the SuperServer 5016I-MR/5016I-MRF lies the X8SIL/X8SIL-F, a
single processor motherboard based on the Intel® 3400 chipset. Below are the
main features of the X8SIL/X8SIL-F. (See Figure 1-1 for a block diagram of the
chipset).
Processors
The X8SIL/X8SIL-F supports a single Intel® 3400 series processor in an LGA1156
socket. Please refer to the motherboard description page on our web site for a
complete listing of supported processors (www.supermicro.com).
Memory
The X8SIL/X8SIL-F has four DIMM slots that can support up to 16 GB of UDIMM
(unbuffered DIMMs) or up to 32 GB or RDIMM (registered DIMMs) DDR3-
1333/1066/800 memory. Dual-channel con gurations are supported. Memory mod-
ules of the same size and speed should be used. See Chapter 5 for details.
Serial ATA
A SATA controller is integrated into the chipset to provide a 3 Gb/s Serial ATA sub-
system, which is RAID 0, 1, 10 and (Windows only) 5 capable. The SATA drives
are hot-swappable units. The X8SIL/X8SIL-F has four SATA ports.
PCI Expansion Slots
The X8SIL/X8SIL-F has two PCI-Express 2.0 x8 slots, one PCI-Express 2.0 x4 (in
a x8 slot) and one 32-bit PCI 33 MHz slot.
I/O Ports
The color-coded I/O ports include a COM port, two USB 2.0 ports, PS/2 mouse
and keyboard ports and two Gb Ethernet ports. An IPMI LAN port is also included
on the X8SIL-F.
Other Features
Other onboard features that promote system health include onboard voltage moni-
tors, a chassis intrusion header, 3-phase switching voltage regulators, chassis and
CPU overheat sensors, Thermal Monitor 2 (TM2) support and a BIOS ash upgrade
utility.
1-3
Chapter 1: Introduction
1-3 Server Chassis Features
The SC512-200 is a mini 1U rackmount server platform con guration. The following
is a general outline of the main features of the SC512-200 chassis.
System Power
When con gured as a SuperServer 5016I-MR/5016I-MRF, the SC512-200 chassis
includes a single 200W power supply.
Serial ATA Subsystem
The SC512-200 chassis was designed to support one internal 3.5" Serial ATA hard
drive. This Serial ATA drive is not hot-swappable; power must be removed from the
system before installing or replacing.
Control Panel
The control panel on the SC512-200 provides important system monitoring and
control information. LEDs indicate power on, network activity, hard disk drive activity,
overheat warning and fan failure. A main power button and a system reset button are
also included. Below the control panel are two USB ports for front side access.
Rear I/O Panel
The rear I/O panel on the SC512-200 provides one motherboard expansion slot, one
COM port (another is internal), two USB ports, PS/2 mouse and keyboard ports, a
graphics port and two Gb Ethernet ports.
Cooling System
The SC512-200 chassis has an innovative cooling design that features one 10-cm
blower-type system cooling fan. The blower fan plugs into a chassis fan header
on the motherboard and an air shroud channels the air ow to ef ciently cool the
processor area.
A fan speed control setting in BIOS allows fan speed to be determined by system
temperature [the recommended setting is 3-pn (Server)].
1-4
SUPERSERVER 5016I-MR/5016I-MRF User's Manual
Figure 1-1. Intel 3400 Chipset:
System Block Diagram
Note: This is a general block diagram. Please see Chapter 5 for details.
IBexPeak
DDR3 (CHA)
PCIe2.0_x8
VRM 11.1
VID[0-7]
LPC I/O
W83627DHG
PCIe x8 SLOT
RJ45
RJ45
DDR3 (CHB)
DIMM1(Far)
DIMM2
DIMM1(Far)
DIMM2
4 UDIMM
MISC VRs
1333/1066MHz
1333/1066MHz
5.0Gb
x4 DMI
2.5Gb
PCH
2.5Gbps
PCIe_x4
PCIe x8 SLOT
PCI 32
1 PCI 32 SLOT
4/6 SATA PORTS
SATA-II
300MB/s
5/7 USB PORTS
USB2.0
480Mbps
FLASH
SPI 16Mb
SPI
PCIe_x1
2.5Gbps
GLAN1
82574L
CK505
Rev1.0 CLOCK
COM1,2
P/S2
LPC
HEALTH
INFO
LPC TPM1.2
P15
LPC
PCIe_x1
2.5Gbps
PCIe2.0_x8
PCIe x8 SLOT
5.0Gb
Intel 3400/3420
GLAN2
82574L
RMII
VGA
PORT
RTL8201N
PHY
RJ45
HERMON WPCM450
WINBOND
PCI32
Xeon 3400
Series
4 RDIMM
(4 Quad rank
RDIMM run on
800MHz)
(option)
1-5
Chapter 1: Introduction
1-4 Contacting Supermicro
Headquarters
Address: Super Micro Computer, Inc.
980 Rock Ave.
San Jose, CA 95131 U.S.A.
Tel: +1 (408) 503-8000
Fax: +1 (408) 503-8008
Email: [email protected] (General Information)
[email protected] (Technical Support)
Web Site: www.supermicro.com
Europe
Address: Super Micro Computer B.V.
Het Sterrenbeeld 28, 5215 ML
's-Hertogenbosch, The Netherlands
Tel: +31 (0) 73-6400390
Fax: +31 (0) 73-6416525
Email: [email protected] (General Information)
[email protected] (Technical Support)
[email protected] (Customer Support)
Asia-Paci c
Address: Super Micro Computer, Inc.
4F, No. 232-1, Liancheng Rd
Chung-Ho Dist., New Taipei City 235
Taiwan
Tel: +886-(2) 8226-3990
Fax: +886-(2) 8226-3991
Web Site: www.supermicro.com.tw
Technical Support:
Tel: +886-(2)-8226-3990
1-6
SUPERSERVER 5016I-MR/5016I-MRF User's Manual
Notes
Chapter 2: Server Installation
2-1
Chapter 2
Server Installation
2-1 Overview
This chapter provides a quick setup checklist to get your SuperServer 5016I-
MR/5016I-MRF up and running. Following the steps in the order given should
enable you to have the system operational within a minimal amount of time. This
quick setup assumes that your server system has come to you with the proces-
sor and memory preinstalled. If your system is not already fully integrated with a
motherboard, processor, system memory etc., please turn to the chapter or section
noted in each step for details on installing speci c components.
2-2 Unpacking the System
You should inspect the box the SuperServer 5016I-MR/5016I-MRF was shipped
in and note if it was damaged in any way. If the server itself shows damage, you
should le a damage claim with the carrier who delivered it.
Decide on a suitable location for the rack unit that will hold the server. It should
be situated in a clean, dust-free area that is well ventilated. Avoid areas where
heat, electrical noise and electromagnetic elds are generated. You will also need
it placed near a grounded power outlet. Read the Rack and Server Precautions
in the next section.
2-3 Preparing for Setup
The SuperServer 5016I-MR/5016I-MRF does not ship with a rack rail hardware
package as the system can be rack mounted without the use of rails. An optional
rack rail package is available if you wish to order from Supermicro. Follow the steps
in the order given to complete the installation process in a minimal amount of time.
Please read this section in its entirety before you begin the installation procedure
outlined in the sections that follow.
Choosing a Setup Location
Leave enough clearance in front of the rack to enable you to open the front door
completely (~25 inches) and approximately 30 inches of clearance in the back
of the rack to allow for suf cient air ow and ease in servicing.This product is for
2-2
SUPERSERVER 5016I-MR/5016I-MRF User's Manual
installation only in a Restricted Access Location (dedicated equipment rooms,
service closets and the like).
This product is not suitable for use with visual display work place devices
acccording to §2 of the the German Ordinance for Work with Visual Display
Units.
2-4 Warnings and Precautions
Rack Precautions
Ensure that the leveling jacks on the bottom of the rack are fully extended to
the oor with the full weight of the rack resting on them.
In single rack installation, stabilizers should be attached to the rack. In multiple
rack installations, the racks should be coupled together.
Always make sure the rack is stable before extending a component from the
rack.
You should extend only one component at a time - extending two or more si-
multaneously may cause the rack to become unstable.
Server Precautions
Review the electrical and general safety precautions in Chapter 4.
Determine the placement of each component in the rack before you install the
rails.
Install the heaviest server components on the bottom of the rack rst, and then
work up.
Use a regulating uninterruptible power supply (UPS) to protect the server from
power surges, voltage spikes and to keep your system operating in case of a
power failure.
Allow the hot plug SATA drives and power supply modules to cool before touch-
ing them.
Chapter 2: Server Installation
2-3
Always keep the rack's front door and all panels and components on the servers
closed when not servicing to maintain proper cooling.
Rack Mounting Considerations
Ambient Operating Temperature
If installed in a closed or multi-unit rack assembly, the ambient operating tempera-
ture of the rack environment may be greater than the ambient temperature of the
room. Therefore, consideration should be given to installing the equipment in an
environment compatible with the manufacturer’s maximum rated ambient tempera-
ture (Tmra).
Reduced Air ow
Equipment should be mounted into a rack so that the amount of air ow required
for safe operation is not compromised.
Mechanical Loading
Equipment should be mounted into a rack so that a hazardous condition does not
arise due to uneven mechanical loading.
Circuit Overloading
Consideration should be given to the connection of the equipment to the power
supply circuitry and the effect that any possible overloading of circuits might have
on overcurrent protection and power supply wiring. Appropriate consideration of
equipment nameplate ratings should be used when addressing this concern.
Reliable Ground
A reliable ground must be maintained at all times. To ensure this, the rack itself
should be grounded. Particular attention should be given to power supply connec-
tions other than the direct connections to the branch circuit (i.e. the use of power
strips, etc.).
2-4
SUPERSERVER 5016I-MR/5016I-MRF User's Manual
2-5 Installing the System into a Rack
(Rack hardware optional)
This section provides information on installing the SuperServer 5016I-MR/5016I-
MRF into a rack unit. If the system has already been mounted into a rack, you can
skip ahead to Sections 2-5 and 2-6.
Basic Installation Procedure
The 5016I-MR/5016I-MRF server comes with two rack mounting brackets, which
are located on each side at the front of the chassis. To mount the system into a
rack, simply screw these brackets directly to the front of the rack (two screws for
each bracket).
Installing with Rackmount Kit
This section is only for customers that have the optional rack mount kit (CSE-PT8).
Each of these assemblies consist of two sections: an inner rail that secures to the
chassis and an outer rail that secures directly to the rack itself (see Figure 2-1).
This is a guideline for installing the unit into a rack with the optional rack kit. You
should also refer to the installation instructions that came with the rack unit you
are using. Be aware that there are a variety of rack units on the market, which may
mean the assembly procedure will differ slightly.
Figure 2-1. Identifying the Sections of the Rack Rails
A
B
Warning! Stability hazard. The rack stabilizing mechanism must be in
place, or the rack must be bolted to the oor before you slide the unit out
for servicing. Failure to stabilize the rack can cause the rack to tip over.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114

Supero SuperServer 5016I-MRF User manual

Category
Server barebones
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI