MV510130 Push Button Combifix

Grothe MV510130 Push Button Combifix Installation guide

  • Hello! I've reviewed the user manual for the GROTHE Combifix push button. This document provides detailed installation instructions, including wiring and mounting procedures. The manual also specifies technical details such as voltage, wiring size, and temperature limits. I'm here to assist you with any questions you may have about this device.
  • What is the required voltage for the push button?
    What is the recommended wire size?
    What is the operating temperature range?
Klingeltaster / Push button Combifix
Installation
* 8 - 12 V ~ (AC 5 mA - 1,5 A)
* 8 - 12 V = (DC 5 mA - 1,0 A)
* Nur Schutzkleinspannung! Protect. low volt. only!
* Druckkraft/Op. force ca. 6 N
* IP41
* Leiter/Wire 0,6 - 0,8 mm
* -20°C...60°C
MV 510130
02/23
!
Installation must be carried out in deenergized condition by an electricial!
Montage muss im spannungslosen Zustand durch eine Elektrofachkraft erfolgen!
GB
D
Ding
Dong1
C
8-12V~
Ding
Dong2
C 0
0
Taster/
Push 1
Taster/
Push 2
(Norm EN61558-2-6/-2-8)
Transform. -> SELV
Drähte abisolieren (6mm)
Strip the wires (6mm)
Drähte anschließen
Connect wires
Namensschild einlegen, schließen
Insert name plate, close cover
36 mm
67
58
Electr. “L”
Electr. “L”
Electr. “0”
Electr. “0”
Entfernen/
remove
C 0
4
Anreihung mehrerer Taster
Combinat. several pushes
2 Stege im Unterteil entfern.
Remove 2 ribs in the base
Drähte anschließen etc.
Connect wires etc.
+
+
L C 0
Option
LED /
Gehäuse öffnen
Open the casing
1
Oder /or
Festschrauben (Dist. 32mm)
Wall fixation (Dist. 32mm)
2
+
+
53773 Hennef
Löhestraße 22
Grothe GmbH
Technische Daten / Technical data
+
+
/