1. Introduction 1
2. Installation & Updates 1
2.1 Installation Instructions (Self-Hosted Only) 2
2.2 Set Language 14
2.3 Header and Footer Customization(Self-Hosted only) 15
3. Supported Web Browsers 16
4. Working with EasyFlux Web 16
4.1 Manage Users 16
4.2 Add Station 17
4.2.1 Manage Station Type 18
4.3 Add LoggerNet Datalogger 19
4.4 Manage Station Users 20
4.5 Manage Metadata 20
4.6 Station Info 21
4.7 Monitor Data 22
4.7.1 QA/QC 23
4.8 Download Data 23
4.9 Alerts 24
4.10 Add Alert 24
4.11 Map 25
4.12 Comparison 26
5. License Agreements 26
5.1 EasyFlux™ Web CSI-Hosted License Agreement 27
5.2 EasyFlux™ Web Self-Hosted License Agreement 35
5. Version 41
6. Index 42
Table of Contents - i
1. Introduction
EasyFlux™ Web is a web-based multiuser software system used for monitoring internet-
connected Campbell Scientific eddy-covariance stations.
EasyFlux Web functions with a Campbell Scientific CR6 running either the EasyFlux-CR6OP
program for open-path eddy-covariance systems or the EasyFlux-CR6CP program for closed-path
eddy-covariance systems, or a CR3000 running the EasyFlux-DL program for open-path eddy-
covariance systems. When a station is added, EasyFlux Web automatically pulls station
information available from the program running in the datalogger (ecosystem, latitude, and
longitude).
After adding your stations, you can graphically monitor data including QA/QC values, download
data, compare data between stations, and set up alerts to notify you by email of data values
outside of user-entered thresholds.
An administrator can set up user accounts and control the rights of each user.
2. Installation & Updates
Installation
There are two installation options for EasyFlux™ Web.
1. EasyFlux Web CSI-Hosted: Campbell Scientific can install the software for you in an Azure-
based environment and provide a link to access the software.
2. EasyFlux Web Self-Hosted: You can install the software directly on your server. When
installing the software on your server, the installation process will also install SQL Server
Express. EasyFlux Web is then accessed by typing the IP address of the server into a web
browser. If EasyFlux Web is installed on your local machine, you can access it by typing
localhost into a web browser or by clicking Launch Browser from the EasyFlux Web Server
Administration Utility.
Updates
EasyFlux Web CSI-Hosted comes with automatic updates as part of your annual subscription cost.
Your purchase of EasyFlux Web Self-Hosted allows you to receive updates for one year free of
charge. From the CSIEasyFlux Web Server Administration Utility
a
, press Check for Updates and
EasyFlux™ Web 1
follow the prompts to update your software. After one year, you are required to purchase yearly
maintenance agreements to continue receiving updates. After purchasing a maintenance
agreement, open the CSIEasyFlux Web Server Administration Utility, and select Manage License |
Register Add-On to input your maintenance license key. You can then press Check for Updates
to see if there is an update available.
Add Station Licenses
If additional station licenses are purchased for EasyFlux Web CSI-Hosted, Campbell Scientific will
add the licenses for you.
If additional station licenses are purchased for EasyFlux Web Self-Hosted, you must add them by
using the CSIEasyFlux Web Server Administration Utility
a
. After opening the utility, select
Manage License |Register Add-On to input the license key. Copy and paste the key from your
customer page on the Campbell Scientific website.
a
CSIEasyFlux Web Server Administration Utility is a separate application. Use the desktop icon to
open the application.
2.1 Installation Instructions (Self-Hosted
Only)
Performing a self-installation on your own machine is very simple. Run your executable file and
follow the prompts, using the default settings shown.
Following is a step-by-step guide to help you through the installation process. Follow each step
making sure that what you see is similar to that shown in the following screenshots. At each
screen, click Next to resume.
EasyFlux™ Web 2
At the following step, input a User Name and Company name. Any name you would like will
work. Input the installation key provided to you in the CDKey field (note: this is not the same as
your station license key).
EasyFlux™ Web 3
EasyFlux™ Web 4
EasyFlux™ Web 5
EasyFlux™ Web 6
EasyFlux™ Web 7
EasyFlux™ Web 8
EasyFlux™ Web 9
EasyFlux™ Web 10
Once you click Finish, you will notice two desktop icons have been created on your machine that
look like the following image :
The top icon is the EasyFlux™ Web Server Administration Utility. This is the utility you will use to
activate your station license keys (note: this is not the same as your installation key you input
during installation), adjust your server settings, start and stop the service, select a database,
perform scheduled backups, and check for updates. Select any option and refer to the help box
at the bottom of the screen for more information. The bottom icon is the LNDB (Loggernet
Database) Manager that shouldn’t require any attention. Please do not adjust any settings within
the LNDB Manager without contacting a Campbell Scientific employee.
Before trying to access your EasyFlux Web account in a web browser, open the EasyFlux Web
Server Administration Utility (shown in the following image). None of the defaults on this page
should require editing. The possible exception is the Port Number, and then only if the default
Port Number is taken by another web server installation.
EasyFlux™ Web 11
To add your station license key click Manage License… and then click Register Add-On…. The
next prompt will allow you to input your station license key. Once this is completed, you can
open your web browser and type in the IP address of your computer or simply type “localhost”
into your browser. This should pull up the main EasyFlux Web page. If a different web page is
pulled up (not EasyFlux Web), you may have a conflicting port number. This will require you
changing your port number, as mentioned above, to one that is not being used. If you are still
having trouble accessing the web page, contact a Campbell Scientific employee.
EasyFlux™ Web 12
EasyFlux™ Web 13
2.2 Set Language
The EasyFlux™ Web user interface text can be displayed in different languages. The Set
Language button (highlighted in the following image) on the navigation bar allows you to select
from a list of installed languages. If your preferred language is not listed, please contact
Campbell Scientific. After receiving a language pack from Campbell Scientific, press Upload
Language Pack to upload the language file.
EasyFlux™ Web 14
2.3 Header and Footer Customization(Self-
Hosted only)
The user can create their own header and footer for EasyFlux™ Web by creating text files with a
text editor. These files must be saved to the EasyFlux Web working directory. (By default, the
working directory is C:\Campbellsci\EasyFlux-Web.)
The files must be named:
l PageHeader.snippet
l PageFooter.snippet
HTML code can be added to these files to display logos, hyperlinks, images, or perform other
html customization as needed.
Contact Campbell Scientific for example files as well as general help on how to customize the
interface to your preference.
EasyFlux™ Web 15
3. Supported Web Browsers
EasyFlux Web has been tested with the following web browsers:
l Chrome
l Firefox
l Safari
Current versions of these web browsers should be used.
4. Working with EasyFlux Web
4.1 Manage Users 16
4.2 Add Station 17
4.2.1 Manage Station Type 18
4.3 Add LoggerNet Datalogger 19
4.4 Manage Station Users 20
4.5 Manage Metadata 20
4.6 Station Info 21
4.7 Monitor Data 22
4.7.1 QA/QC 23
4.8 Download Data 23
4.9 Alerts 24
4.10 Add Alert 24
4.11 Map 25
4.12 Comparison 26
.
4.1 Manage Users
To add user accounts, click on the User Info button in the top right corner.
EasyFlux™ Web 16
In the resulting window, click Manage Users, and then Add User. Fill in the requested
information. Note that the email address you provide will be used to send the alerts that a user is
subscribed to.
The Is Administrator checkbox gives a user the ability to add, edit, and delete users, stations, and
alerts, as well as edit metadata. If the Is Administrator checkbox is not checked, by default, the
user is able to view data, download data, and subscribe to alerts for any station they are
associated with. A user can be associated with a station and their permissions can be changed
from the Manage Station Users dialog box (see Manage Station Users (p. 20) for more
information).
An email will be sent to the new user, when an account is created. The email will contain a link
that the new user will follow where they will be instructed to create a password.
If you forget your password, go to the Login screen and select Forgot Password.
By default, there is a Public user that is able to view and download data for each station that it is
associated with.
NOTE:
You must be an administrator in order to manage users. If an administrative account has not
been set up, a Create User box will be displayed when EasyFlux™ Web is opened to allow you
to create an administrator.
You can also click Station Permissions to select any other enabled, non-admin user and to set the
rights for the selected user on all visible stations.
4.2 Add Station
A station can be added by clicking Add Station from the Map or Stations view to display the New
Station dialog box. If the datalogger has already been added to LoggerNet, you can select it from
the Manage LoggerNet Dataloggers drop-down list. If the datalogger has not been added to
LoggerNet, select Add LoggerNet Datalogger from the list. The Add LoggerNet Datalogger
dialog box will be displayed (see Add LoggerNet Datalogger (p. 19) for more information). After
EasyFlux™ Web 17
adding the LoggerNet datalogger, you will be returned to the Add Station dialog box with the
newly added LoggerNet datalogger selected.
On the left side of the screen, you can load an image or a video and provide a Description for the
station.
If available in the datalogger program, the Ecosystem, Latitude, Longitude, and Elevation fields
will be automatically filled in. (Note that the program is only checked for these fields when the
station is first added to EasyFlux™ Web. They can be modified by the user at any time in EasyFlux
Web.)
The default name of the EasyFlux Web station will be the same as its LoggerNet name. You can
give it a unique name in the Name field.
Select the Type of station: Select the Type of station. There are two types by default: EasyFlux DL
CR6 or EasyFlux DL CR3000. These types of stations are associated with dataloggers that have an
EasyFlux DL program running on them. Alerts, Data Monitors, and Metadata are all populated
based off of the information within the EasyFlux DL program. If this site's datalogger has a
different program then a new Type of site will need to be manually created. To create a new Type
of station see Manage Station Type below.
If not filled in automatically, specify the Ecosystem, the Latitude and Longitude in decimal, and
the Elevation of the station in meters, .
You can optionally enter an Abbreviation, Institution, and Location. (Clicking the icon next to
Location will fill in the information based on your current location. This will also override the
Latitude and Longitude obtained from the datalogger program.)
Press Save to save the information and exit the dialog box.
To delete a station or modify its settings, go to the Station Info, click on the station of interest on
the station dropdown, navigate to the Manage Station dropdown. Select Delete Station to delete
the station. Select Edit Properties to open the Edit Station dialog box which will allow you to
modify the settings of the station. From the Edit Station dialog box, you can use the
Enabled/Disabled toggle to choose whether a station is enabled. A disabled station will show up
with a black slash on the map. When a station is disabled, data will not be collected and alerts
will not be sent.
4.2.1 Manage Station Type
From the Edit Station dialogue box click on Manage Station Types. From here you can select
either New Type from this Station or Edit Station Types. If you select New Type from this Station a
prompt will appear that will allow you to name this station type. The station type will be created
based upon the configuration (Alerts, Data Monitors, and Metadata) of the site selected. Once
the type template has been created, it can be used to specify the configuration of new stations
EasyFlux™ Web 18
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45

Campbell Scientific EasyFlux Owner's manual

Type
Owner's manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI