MD30 Measurements
• When using RoadAI services, the default settings are the following (not adjustable):
• The data transfer interval from the mobile sensor to RoadAI is 100 ms.
The RoadAI phone app shows data with a 200 ms interval.
• When implementing the MD30 interface, you can set the data transfer interval from the mobile
sensor to the data collection system to 25 ms ... 5 s.
For more information, see Vaisala Mobile Detector MD30 Interface Description.
Table 1 MD30 Measurements
Measurement Parameter
Unit
1)
Description/Value Measurement
Int
erval
Grip − 0 ... 1 25 ms
Surface state − Dry, moist, wet, ice, snow, slush 25 ms
Surface layer thickness mm/in 25 ms
Surface temperature °C/°F
Freely configurable oset
1)
150 ms
Air t
emperature °C/°F
Freely configurable oset
1)
1 s
De
w/frost point temperature °C/°F 1 s
Relative humidity %RH 1 s
1) Available in MD30 interface.
Reference Guide M212339EN-B
2
Safety
MD30 is classified as a Class 1 laser device in accordance with International Standard IEC/EN 60825-1.
This means that it is eye-safe under reasonably foreseeable conditions of operation, including the use
of optical instruments for intrabeam viewing.
The device is equipped with the following information on the bottom of MD30:
CLASS 1 LASER PRODUCT