  • Hello! I am an AI chatbot trained to assist you with the Electrolux 20 GN 2/1 User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
From the Electrolux Group
DOC. NO. 5958 932 00
EDITION 1 E 0410 LA
- GAS STEAM/CONVECTION OVENS
INSTALLATION, OPERATION AND MAINTENANCE Page 9
- FORNI CONVEZIONE/VAPORE A GAS
INSTALLAZIONE, USO E MANUTENZIONE Pagina 33
- FOURS À CONVECTION/VAPEUR À GAZ
INSTALLATION, UTILISATION ET ENTRETIEN Page 57
- HORNOS DE CONVECCIÓN/VAPOR DE GAS
INSTALACIÓN, USO Y MANTENIMIENTO Pág. 81
IT
CDN
ES
USA
2
5958 932 00
INSTALLATION DIAGRAM
SCHEMI DI INSTALLAZIONE
SCHEMAS D'INSTALLATION
ESQUEMA PARA LA INSTALACIÓN
SAFETY INSTRUCTIONS
Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance.
WARNING: Improper installation, adjustment, alteration, service or maintenance can cause property damage,
injury or death. Read the installation, operating and maintenance instructions thoroughly before installing or
servicing this equipment.
Danger! Explosion hazard.
In the event a gas odor is detected, shut down equipment at the main shut-off valve. Immediatly call the emergency phone number
of your gas supplier.
Read each section of this manual before installing and operating.
PER LA VOSTRA SICUREZZA
Non immagazzinare o usare benzina o altri materiali infiammabili o liquidi nelle vicinanze di questa o qualsiasi
altra apparecchiatura.
AVVERTENZA: Installazione impropria, adattamenti, modifiche o manutenzione possono causare danni alla
proprieta` o morte. Leggere attentamente le istruzioni per l'installazione, il funzionamento e la manutenzione prima di
installare questa apparecchatura.
Pericolo! Pericolo di esplosione.
Nel caso in cui venga avvertito odore di gas spegnere l'apparecchiatura chiudendo la valvola principale a monte della stessa. Immediatamente
telefonare al numero d'emergenza del vostro fornitore di gas.
Leggere tutte le parti di questo manuale prima di installare o mettere in funzione l'apparecchiatura.
POUR VOTRE SECURITE
Il ne faut pas emmagasiner ou utiliser l’essence ou d’autres matériaux inflammables ou liquides à côté de cet
appareil ou d’autres appareils.
AVERTISSEMENT: L’installation, l’adaptation, la modification et l’entretien inadéquats peuvent causer des
dommages aux structures ou aux personnes et la mort. Lire attentivement les instructions d’installation, de fonctionnement
et d’entretien avant d’installer cet appareil.
Danger! Danger d’explosion.
Si l’on sent l’odeur de gaz, arrêter l’appareil en fermant la soupape principale en amont. Téléphoner immédiatement au numéro
d’urgence de votre fournisseur de gaz.
Lire toutes les parties de ce mode d’emploi avant d’installer ou mettre en fonction l’appareil.
PARA SALVAGUARDAR VUESTRA SEGURIDAD
No almacenar o utilizar gasolina u otros materiales inflamables o líquidos cerca de este u otros aparatos.
ADVERTENCIA: Una instalación indacuada, lo mismo que modificaciones y operaciones de mantenimiento
incorrectas pueden causar daños a la estructura y a las personas y provocar la muerte. Antes de instalar el aparato leer con
mucha atención las instrucciones de la instalación, del funcionamiento y del mantenimiento.
Peligro! Peligro de explosión.
En el caso que se sienta olor de gas, apagar inmediatamente el aparato cerrando la válvula principal colocada aguas arriba de
la misma. Llamar inmediatamente el número de teléfono de emergencia de la compañía erogadora del gas.
Leer todas las partes de este manual antes de llevar a cabo la instalación o de poner en marcha el aparato.
IT
CDN
ES
USA
IT
CDN
ES
USA
3
5958 932 00
Mod.: 6 GN 1/1
1a
USA
H - Gas connection ø1/2" NPT gasline
I - Power supply cable inlet
B - Water supply connection (0.5- 5 °F) ø3/4" NPT gasline
C - Water drain connection ø1"1/4 NPT gasline
N - Steam condens. water connection ø3/4" NPT gasline
IT
H - Attacco gas ø1/2" NPT gasline
I - Entrata cavo elettrico
B - Attacco alim. acqua (0,5 - 5 °F) ø3/4" NPT gasline
C - Collettore scarico acqua ø1"1/4 NPT gasline
N - Attacco acqua Conden. fumane ø3/4" NPT gasline
CDN
H - Entée gaz ø1/2" NPT gasline
I - Entrée câble électrique
B - Entrée eau (0,5 - 5 °F) ø3/4" NPT gasline
C - Collecteur évacuation eau ø1"1/4 NPT gasline
N - Entrée eau Conden.vapeurs ø3/4" NPT gasline
ES
H - Conexión de gas ø1/2" NPT gasline
I - Ingreso cable eléctrico
B - Conexión de agua (0,5 - 5 °F) ø3/4" NPT gasline
C - Colector del desagüe ø1"1/4 NPT gasline
N - Entrada del agua de condensación ø3/4" NPT gasline
4
5958 932 00
1b
Mod.: 10 GN 1/1
USA
H - Gas connection ø1/2" NPT gasline
I - Power supply cable inlet
B - Water supply connection (0.5- 5 °F) ø3/4" NPT gasline
C - Water drain connection ø1"1/4 NPT gasline
N - Steam condens. water connection ø3/4" NPT gasline
IT
H - Attacco gas ø1/2" NPT gasline
I - Entrata cavo elettrico
B - Attacco alim. acqua (0,5 - 5 °F) ø3/4" NPT gasline
C - Collettore scarico acqua ø1"1/4 NPT gasline
N - Attacco acqua Conden. fumane ø3/4" NPT gasline
CDN
H - Entée gaz ø1/2" NPT gasline
I - Entrée câble électrique
B - Entrée eau (0,5 - 5 °F) ø3/4" NPT gasline
C - Collecteur évacuation eau ø1"1/4 NPT gasline
N - Entrée eau Conden.vapeurs ø3/4" NPT gasline
ES
H - Conexión de gas ø1/2" NPT gasline
I - Ingreso cable eléctrico
B - Conexión de agua (0,5 - 5 °F) ø3/4" NPT gasline
C - Colector del desagüe ø1"1/4 NPT gasline
N - Entrada del agua de condensación ø3/4" NPT gasline
5
5958 932 00
1c
Mod.: 10 GN 2/1
USA
H - Gas connection ø1/2" NPT gasline
I - Power supply cable inlet
B - Water supply connection (0.5- 5 °F) ø3/4" NPT gasline
C - Water drain connection ø1"1/4 NPT gasline
N - Steam condens. water connection ø3/4" NPT gasline
IT
H - Attacco gas ø1/2" NPT gasline
I - Entrata cavo elettrico
B - Attacco alim. acqua (0,5 - 5 °F) ø3/4" NPT gasline
C - Collettore scarico acqua ø1"1/4 NPT gasline
N - Attacco acqua Conden. fumane ø3/4" NPT gasline
CDN
H - Entée gaz ø1/2" NPT gasline
I - Entrée câble électrique
B - Entrée eau (0,5 - 5 °F) ø3/4" NPT gasline
C - Collecteur évacuation eau ø1"1/4 NPT gasline
N - Entrée eau Conden.vapeurs ø3/4" NPT gasline
ES
H - Conexión de gas ø1/2" NPT gasline
I - Ingreso cable eléctrico
B - Conexión de agua (0,5 - 5 °F) ø3/4" NPT gasline
C - Colector del desagüe ø1"1/4 NPT gasline
N - Entrada del agua de condensación ø3/4" NPT gasline
6
5958 932 00
1d
Mod.: 20 GN 1/1
USA
H - Gas connection ø1" NPT gasline
I - Power supply cable inlet
B - Water supply connection (0.5- 5 °F) ø3/4" NPT gasline
C - Water drain connection ø1"1/4 NPT gasline
N - Steam condens. water connection ø3/4" NPT gasline
IT
H - Attacco gas ø1" NPT gasline
I - Entrata cavo elettrico
B - Attacco alim. acqua (0,5 - 5 °F) ø3/4" NPT gasline
C - Collettore scarico acqua ø1"1/4 NPT gasline
N - Attacco acqua Conden. fumane ø3/4" NPT gasline
CDN
H - Entée gaz ø1" NPT gasline
I - Entrée câble électrique
B - Entrée eau (0,5 - 5 °F) ø3/4" NPT gasline
C - Collecteur évacuation eau ø1"1/4 NPT gasline
N - Entrée eau Conden.vapeurs ø3/4" NPT gasline
ES
H - Conexión de gas ø1" NPT gasline
I - Ingreso cable eléctrico
B - Conexión de agua (0,5 - 5 °F) ø3/4" NPT gasline
C - Colector del desagüe ø1"1/4 NPT gasline
N - Entrada del agua de condensación ø3/4" NPT gasline
7
5958 932 00
1e
Mod.: 20 GN 2/1
USA
H - Gas connection ø1" NPT gasline
I - Power supply cable inlet
B - Water supply connection (0.5- 5 °F) ø3/4" NPT gasline
C - Water drain connection ø1"1/4 NPT gasline
N - Steam condens. water connection ø3/4" NPT gasline
IT
H - Attacco gas ø1" NPT gasline
I - Entrata cavo elettrico
B - Attacco alim. acqua (0,5 - 5 °F) ø3/4" NPT gasline
C - Collettore scarico acqua ø1"1/4 NPT gasline
N - Attacco acqua Conden. fumane ø3/4" NPT gasline
CDN
H - Entée gaz ø1" NPT gasline
I - Entrée câble électrique
B - Entrée eau (0,5 - 5 °F) ø3/4" NPT gasline
C - Collecteur évacuation eau ø1"1/4 NPT gasline
N - Entrée eau Conden.vapeurs ø3/4" NPT gasline
ES
H - Conexión de gas ø1" NPT gasline
I - Ingreso cable eléctrico
B - Conexión de agua (0,5 - 5 °F) ø3/4" NPT gasline
C - Colector del desagüe ø1"1/4 NPT gasline
N - Entrada del agua de condensación ø3/4" NPT gasline
9
USA
5958 932 00
INSTRUCTIONS FOR INSTALLATION AND USE
Table of contents Page
- Installation diagram .......................................................... 2
- APPLIANCE IDENTIFICATION
air-o-steam® ELECTRIC COMBI OVENS
6 GN 1/1
260450 260462 260456
260451 260463 260457
°
**
°
**
°
**
400 230 200
2. TABLE 1: TECHNICAL DATA
260462
Rating plate
PNC 9PDX 260462 05
- CONTROL PANEL FIGURES .......................................... 105
- Appliance identification ................................................... 9
I. MAIN FEATURES ............................................................. 10
1. Description of appliance ............................................ 10
2. Table 1: Technical data ................................................. 11
3. Precautions .................................................................. 12
4. Safeguarding the environment................................... 13
4.1 Packaging .............................................................. 13
4.2 Use ......................................................................... 13
4.3 Cleaning ................................................................. 13
4.4 Disposal ................................................................. 13
II. INSTRUCTIONS FOR INSTALLATION ........................... 14
1. Place of Installation .................................................... 14
1.1 Ventilation ................................................................. 14
1.2 Reference standards ................................................ 14
1.3 Unpackaging ............................................................ 14
1.4 Immediately inspect for shipping damage ............... 14
2. Positioning .................................................................... 14
3. Combusted gas discharge .......................................... 14
3.1 Foreword .................................................................. 14
3.2
Installation of accessories ............................... 15
3.3 Warnings regarding the fluimg system .................. 15
4. Electrical connection .................................................. 15
4.1 Installing the power supply cable ........................... 16
5. Water mains connection ............................................. 16
5.1 Water supply characteristics .................................. 16
5.2 Water drain system ................................................ 16
6. Gas connection ........................................................... 17
6.1 Warning .................................................................. 17
6.2 Nominal heat output ............................................... 17
6.2 Checking the supply pressure ............................... 17
7. Safety devices ............................................................. 17
8. Operation check .......................................................... 17
9. Servicing ....................................................................... 17
10. Troubleshooting ........................................................... 18
11. Layout of main components ..................................... 18
III. INSTRUCTIONS FOR USE ............................................ 19
1. Opening the oven door ............................................... 19
1.1 6- and 10-grid models ............................................ 19
1.2 20-GRID models .................................................... 19
2. Closing the oven door ................................................ 19
2.1 6- and 10-GRID models ......................................... 19
2.2 20-GRID models .................................................... 19
3. Description of the control panel ................................ 20
3.1 Introduction ............................................................ 20
3.2 Main controls.......................................................... 20
3.3 Main cooking modes .............................................. 20
3.4 Special cooking modes .......................................... 20
3.5 Additional functions ................................................ 21
USING THE OVEN ................................................................. 22
4. Introduction ................................................................. 22
4.1 Switching the oven on ............................................ 22
4.2 Selecting the controls ............................................ 22
4.3 Manual controls...................................................... 22
4.4 Automatic controls ................................................. 26
5. Information and error codes ...................................... 29
6. SWITCHING off in the event of a fault ....................... 30
7. Care and maintenance ................................................ 30
7.1 Periodical maintenance of the BOILER ................. 31
7.2 Replacing CONSUMABLE components ................ 32
7.3 Special cleaning instructions ................................. 32
10
USA
5958 932 00
1. DESCRIPTION OF APPLIANCE
This booklet describes a number of appliance models.
For more detailed information about the model in your possession,
refer to "Technical Data" table 1.
The appliance has the following features:
Digital temperature controlle.
Thermostatic probe for measuring the core temperature of pro-
ducts (core temperature probe).
Automatic flush to drain every two hour to prevent the build-up of
lime-scale in the boiler.
Periodic draining and automatic washing of the boiler to prevent
the build-up of lime-scale.
Boiler lime-scale level indicator (see corresponding paragraph).
Oven chamber automatic fast steam drain device for gratins.
Air-break (anti-backup drain) device to prevent backflows from
the drain system from entering the oven.
Halogen lighting in the cooking chamber.
Double-action door opening safety mechanism designed to
protect the user from scalding steam.
Double-glazed oven door for reduced heat dispersion into the
kitchen and low temperatures on the exterior of the oven.
Self-diagnostics system indicating oven faults using error codes
(see "Information and error codes ").
I. MAIN FEATURES
11
USA
5958 932 00
2. TABLE 1: TECHNICAL DATA
PROPANE pressure
NATURAL pressure
Gas type
Construction type
Diagram of fumes
discharge system
ISO 7/1 gas
connectionDiameter
Nominal heat output
NATURAL
B
o
il
er un
i
t nom
i
na
l
heat output
NATURAL
Convector unit nominal
heat output
NATURAL
Shipping depth
CONVECTOR °
Net weight
Shipping weight
Shipping width
Nominal heat output
PROPANE
B
o
il
er un
i
t nom
i
na
l
heat output
PROPANE
Convector unit nominal
heat output
PROPANE
GRIDS
BOILER **
SUPPLY VOLTAGE
Maximum load capacities
(food)
Total Watts
PNC *
Shipping height
6 GN 1/1 10 GN 1/1 10 GN 2/1 20 GN 1/1 20 GN 2/1
260095 260148 260096 260149 260097 260150 260098 260151 260099 260152
° ° ° ° ° ° ° ° ° °
** ** ** ** ** ** ** ** ** **
208V 2ph
60Hz
6amps
120V 1ph
60Hz
10amp
208V 2ph
60Hz
6amps
120V 1ph
60Hz
10amps
208V 2ph
60Hz
6amps
120V 1ph
60Hz
10amps
208V 2ph
60Hz
10amps
120V 1ph
60Hz
16amps
208V 2ph
60Hz
15amps
120V 1ph
60Hz
20amps
0,25 kW 0,25 kW 0,3 kW 0,3 kW 1 kW 1 kW 0,5 kW 0,5 kW 2 kW 2 kW
66 lbs.
(30 kg)
66 lbs.
(30 kg)
110 lbs.
(50 kg)
110 lbs.
(50 kg)
220 lbs.
(100 kg)
220 lbs.
(100 kg)
220 lbs.
(100 kg)
220 lbs.
(100 kg)
440 lbs.
(200 kg)
440 lbs.
(200 kg)
253.53 lbs.
(115 kg)
253.53 lbs.
(115 kg)
319.67 lbs
(145 kg)
319.67 lbs
(145 kg)
504.86 lbs
(229 kg)
504.86 lbs
(229 kg)
533.52 lbs.
(242 kg)
533.52 lbs.
(242 kg)
551.16 lbs
(250 kg)
551.16 lbs
(250 kg)
295.42 lbs.
(134 kg)
295.42 lbs.
(134 kg)
363.76 lbs.
(165 kg)
363.76 lbs.
(165 kg)
538 lbs
(244 kg)
538 lbs
(244 kg)
639.34 lbs.
(290 kg)
639.34 lbs.
(290 kg)
573 lbs
(260 kg)
573 lbs
(260 kg)
37 1/64"inch
(940 mm)
37 1/64"inch
(940 mm)
37 1/64"inch
(940 mm)
37 1/64"inch
(940 mm)
50"inch
(1270 mm)
50"inch
(1270 mm)
37 1/64"inch
(940 mm)
37 1/64"inch
(940 mm)
47 5/8"inch
(1210 mm)
47 5/8"inch
(1210 mm)
40 15/16"inch
(1040 mm)
40 15/16"inch
(1040 mm)
49 5/8"inch
(1260 mm)
49 5/8"inch
(1260 mm)
52 3/8"inch
(1330 mm)
52 3/8"inch
(1330 mm)
79 1/2"inch
(2020 mm)
79 1/2"inch
(2020 mm)
70 7/8"inch
(1800 mm)
70 7/8"inch
(1800 mm)
38 9/16"inch
(980 mm)
38 9/16"inch
(980 mm)
38 9/16"inch
(980 mm)
38 9/16"inch
(980 mm)
44 7/8"inch
(1140 mm)
44 7/8"inch
(1140 mm)
42 1/2"inch
(1080 mm)
42 1/2"inch
(1080 mm)
41 3/4"inch
(1060 mm)
41 3/4"inch
(1060 mm)
1/2" M 1/2" M 1/2" M 1/2" M 1/2" M 1/2" M 1" M 1" M 1" M 1" M
81943
btu/h
(24 kW)
81943
btu/h
(24 kW)
163886
btu/h
(48 kW)
163886
btu/h
(48 kW)
218515
btu/h
(64 kW)
218515
btu/h
(64 kW)
218515
btu/h
(64 kW)
218515
btu/h
(64 kW)
443859
btu/h
(130 kW)
443859
btu/h
(130 kW)
40972
btu/h
(12 kW)
40972
btu/h
(12 kW)
78529
btu/h
(23 kW)
78529
btu/h
(23 kW)
105843
btu/h
(31 kW)
105843
btu/h
(31 kW)
105843
btu/h
(31 kW)
105843
btu/h
(31 kW)
204858
btu/h
(60 kW)
204858
btu/h
(60 kW)
40972
btu/h
(12 kW)
40972
btu/h
(12 kW)
85358
btu/h
(25 kW)
85358
btu/h
(25 kW)
112672
btu/h
(33 kW)
112672
btu/h
(33 kW)
112672
btu/h
(33 kW)
112672
btu/h
(33 kW)
239001
btu/h
(70 kW)
239001
btu/h
(70 kW)
75115
btu/h
(22 kW)
75115
btu/h
(22 kW)
146815
btu/h
(43 kW)
146815
btu/h
(43 kW)
194615
btu/h
(57 kW)
194615
btu/h
(57 kW)
194615
btu/h
(57 kW)
194615
btu/h
(57 kW)
392645
btu/h
(115 kW)
392645
btu/h
(115 kW)
37557
btu/h
(11 kW)
37557
btu/h
(11 kW)
68286
btu/h
(20 kW)
68286
btu/h
(20 kW)
92186
btu/h
(27 kW)
92186
btu/h
(27 kW)
92186
btu/h
(27 kW)
92186
btu/h
(27 kW)
187787
btu/h
(55 kW)
187787
btu/h
(55 kW)
37557
btu/h
(11 kW)
37557
btu/h
(11 kW)
78529
btu/h
(23 kW)
78529
btu/h
(23 kW)
102429
btu/h
(30 kW)
102429
btu/h
(30 kW)
102429
btu/h
(30 kW)
102429
btu/h
(30 kW)
204858
btu/h
(60 kW)
204858
btu/h
(60 kW)
NATURA L
PROPA NE
NATURAL
PROPANE
NATURAL
PROPANE
NATURAL
PROPANE
NATURAL
PROPANE
NATURAL
PROPANE
NATURAL
PROPANE
NATURAL
PROPANE
NATURAL
PROPANE
NATURAL
PROPANE
A3
B13
A3
B13
A3
B13
A3
B13
A3
B13
A3
B13
A3
B13
A3
B13
A3
B13
A3
B13
7"w c
(17,4mbar)
7"w c
(17,4mbar)
7"w c
(17,4mbar)
7"w c
(17,4mbar)
7"w c
(17,4mbar)
7"w c
(17,4mbar)
7"w c
(17,4mbar)
7"w c
(17,4mbar)
7"w c
(17,4mbar)
7"w c
(17,4mbar)
11"w c
(27,4mbar)
11"w c
(27,4mbar)
11"w c
(27,4mbar)
11"w c
(27,4mbar)
11"w c
(27,4mbar)
11"w c
(27,4mbar)
11"w c
(27,4mbar)
11"w c
(27,4mbar)
11"w c
(27,4mbar)
11"w c
(27,4mbar)
1a-1b-1c 1a-1b-1c 1a-1b-1c 1a-1b-1c1a-1b-1c
Noise emission data: Noise emissions generated by the appli-
ances described in this booklet do not exceed 70 dB (A).
*
Your appliance model is indicated in the box marked PNC on
the Identification dataplate affixed to the bottom left hand side of
the oven.
12
USA
5958 932 00
3. PRECAUTIONS
• The following terms alert you to potentially dangerous conditions
to the operator, service personnel or to the equipment.
Danger! This term warns of immediate hazards which will result in
severe injury or death.
Warning! This term refers to a potential hazard or unsafe
practice which could result in injury or death.
Notice. This term refers to information that needs special
attention or must be fully understood, even though not dangerous.
Keep the appliance area free and clear from combustibles.
Warning
Fire hazard.
For your safety, do not store or use gasoline or other
flammable, vapors and liquids in the vicinity of this or any other
appliance.
Keep area around appliances free and clear of combustibles
Warning!
Failure to properly vent the oven can be hazardous to the
health of the operator; and will result in operational problems,
unsatisfactory baking, and possible damage to the equipment.
Damage sustained as a direct result of improper ventilation will
not be covered by the Manufacturer's warranty.
NOTICE: INTENDED FOR COMMERCIAL USE ONLY. NOT
FOR HOUSEHOLD USE.
CAUTION HOT SURFACES
CAUTION RISK ELECTRIC SHOCK
CAUTION: Do not locate unit adjacent to any high heat or
grease producing piece of equipment, such as a range top,
griddle, fryer, etc., that could allow radiant heat to raise the
exterior temperature of the Air-O-Steam Oven.
Carefully read this instruction booklet, as it contains important
advice for safe installation, operation and maintenance.
Keep this instruction booklet in a safe place for future reference.
• The installation of this unit must conform to local codes or, in the
absence of local codes, to all National Codes governing plumbing,
sanitation, safety and good trade practices.
WARNING: The equipment warranty is not valid unless the
appliance is installed, started and demonstrated under the
supervision of a factory trained installer.
WARNING: The unit must be installed by Personnel who are
qualified to work with electricity and plumbing. Improper installation
can cause injury to personnel and/or damage to the equipment.
The unit must be installed in accordance with applicable codes.
Important: The installation instructions contained herein
are for the use of qualified installation and service
personnel only. Installation or service by other than
qualified personnel may result in damage to the appliance
and/or injury to the operator. FAILURE TO COMPLY
WITH INSTALLATION INSTRUCTION OR IMPROPER
INSTALLATION WILL VOID WARRANTY AND
RESPONSIBLITIES OF THE MANUFACTURE.
• Our appliances have been studied and optimized to give the
highest performance. This appliance is intended for industrial use
only and is specifically designed to cook food. Any other use will be
considered “improper use” and will void the warranty and
manufacturer liability.
WARNING: ANY POTENTIAL USER OF THE EQUIPMENT
SHOULD BE TRAINED IN SAFE AND CORRECT OPERATIONG
PROCEDURES.
WARNING: BEFORE SERVICING, DISCONNET THE
ELECTRICAL SERVICE AND PLACE A RED TAG AT THE
DISCONNECT SWITCH TO INDICATED WORK IS BEING DONE
ON THAT CIRCUIT.
NOTICE: Using any parts other than OEM original spare parts
relieves the manufacturer of all warranty and liability.
NOTICE: Manufacturer reserves the right to change specifications
at any time without notice.
Failure to comply with the above requirement may jeopardise
the safety of the appliance and invalidate the guarantee.
WARNING: DO NOT SPRAY THE OUTSIDE OF THE
APPLIANCE WITH WATER OR CLEAN WITH A WATER JET.
CLEANING WITH A WATER JET CAN IMPREGNAT
CHLORIDES INTO THE STAINLESS STEEL, CAUSING THE
ONSET OF CORROSION.
WARNING: DO NOT USE PRODUCTS CONTAINING
CHLORINE (BLEACH, HYDROCHLORIC ACID ETC.) EVEN
DILUTED, TO CLEAN STEEL SURFACES.
WARNING: DO NOT USE CORROSIVE SUBSTANCES (E.G.
MURIATIC ACID) TO CLEAN THE FLOOR UNDER THE
APPLIANCE.
13
USA
5958 932 00
4. SAFEGUARDING THE ENVIRONMENT
4.1 PACKAGING
• All the packaging materials used are environmentally safe and
friendly. They may be stored without fear or danger. They may be
recycled or burned in a special waste incineration plant. Recyclable
plastic components are marked as follows:
polyethylene : external wrapping film, instructions
PE booklet bag and gas injectors bag
polypropylene: top packaging panels and straps
pp
expanded polystyrene: protective surround elements
PS
4.2 USE
• The appliance has been designed and perfected under laboratory
testing conditions to offer exceptional levels of performance.
However, to minimise energy consumption (electricity, gas and
water), do not leave the appliance in operation for long periods
without food in the oven chamber and avoid conditions that
reduce efficiency (e.g. door open). We also recommend preheating
the appliance immediately prior to use.
4.3 CLEANING
• To minimise the emission of pollutants into the environment,
clean the appliance (externally and, where necessary, internally)
with products that are at least 90% biodegradable.
4.4 DISPOSAL
• Appliances that have reached the end of their service life should
be suitably disposed of.
• The appliance is made from more than 90% recyclable materials
(stainless steel, iron, aluminium, galvanised sheet steel, etc.).
These materials may therefore be scrapped in accordance with
local waste disposal regulations at a conventional recycling plant.
• Make the appliance unusable by cutting off the power cord. Also
remove any compartment or interior closure device fitted on the
appliance to prevent persons from becoming trapped inside.
14
USA
5958 932 00
1.4 IMMEDIATELY INSPECT FOR SHIPPING DAMAGE
The container should be examined for damage before and during
unloading. The freight carrier has assumed responsibility for its
safe transit and delivery. If damaged equipment is received,
either apparent or concealed, a claim must be made with the
delivering carrier. Apparent damage or loss must be noted on the
freight bill at the time of delivery. The freight bill must then be
signed by the carrier representative (Driver). If the bill is not
signed, the carrier may refuse the claim. The supply can supply
the necessary forms. A request for inspection must be made to
the carrier within 15 days if there is concealed damage or loss that
is not apparent until after the equipment is uncrated. The carrier
should arrange an inspection. Be certain to hold all contents plus
all packing material. Under no circumstances should a damaged
appliance be returned to the manufacturer without prior notice
and written authorization.
2. POSITIONING
Refer to the installation diagrams at the beginning of this
booklet for the space requirements and connection dimensions of
the appliance.
Clearance of approximately 23.62" (50cm) must be left between
the appliance’s left side panel and adjacent structures in order to
provide space for maintenance operations when needed; the
right side panel and the rear panel of the appliance must be at
least 1.97" (5cm) from adjacent structures.
Place the appliance in the required position and level the oven
with a slight pitch toward the rear to help drain water from
chamber using the appropriate bullet feet.
The appliance is not suitable for built-in installation.
Warning: The oven must be installed on an even (level) non-
flammable flooring and any adjacent walls must be non-flammable.
Recommended minimum clearance are specified in this manaul.
Important
:
Make sure steam from the oven’s drain or adjacent
appliances does not enter the aeration vents under the
appliance, designed to cool internal components
located at the bottom of the appliance.
3. COMBUSTED GAS DISCHARGE
3.1 FOREWORD
In relation to the combustion technology utilised, gas fired steam/
convection ovens are classified in accordance with their
"Construction Type". For each of these types of appliances
applicable regulations stipulate a specific type of combusted gas
discharge system.
Consequently, before installing the discharge system:
a) identify the "Construction type" of your model in Table 1
(technical data) or by checking the appliance identification
dataplate;
b) choose the diagram with the type of construction among
those shown as follows (fig. 1a-1b-1c), depending on how you
intend to exhaust the appliance fumes from the place of installation
(e.g. discharge under extraction hood, direct to the outside, or in
a central flue).
II. INSTRUCTIONS FOR INSTALLATION
Important
: The oven outer panels must be removed to
perform the operations described in this chapter
.
Since the
appliance must be switched on to make certain
adjustments, exercise the utmost care when working in the
vicinity of live electrical parts.
1. PLACE OF INSTALLATION
1.1 VENTILATION
The necessity for a properly designed and installed ventilation
system cannot be over emphasized. The ventilation system will
allow the unit to function properly while removing unwanted vapors
and products of combustion from the operating area.
The appliance must be vented with a properly designed mechanically
driven exhaust hood. The hood should be sized to completely
cover the equipment plus an overhang of a least 6"/15.3cm on all
sides not adjacent to a wall. The capacity of the should be sized
appropriately and provisions for adequate makeup air.
Refer to your local ventilation codes. In the absence of local codes,
refer to the National ventilation code titled, “Standard for the
Installation of Equipment for the Removal of Smoke and Grease
Laden Vapors from Commercial Cooking Equipment”, NFPA-96-
Latest Edition.
It is recommended that the ventilation system and duct work be
checked at prevailing intervals as specified by the hood manufactured
The appliance must only be installed in adequately ventilated
premises.
NOTICE: Proper ventilation is the owner's is responsibility. Any
problem due to improper ventilation will not be covered by the
warranty.
1.2 REFERENCE STANDARDS
Note: The electric supply installation must satisfy the requirements
of the appropriate statutory authority, such as the National
Electrical Code (NEC) ANSI/NFPA70, (U.S.A..): the Canadian
Electrical Code, CSA C22.2; or other applicable regulations.
Note: The electric supply connection must meet all national and
local electrical code requirements.
Note: The installation of this unit must conform to local codes or,
in the absence of local codes, to all National Codes governing
plumbing, sanitation, safety and good trade practices, and to the
National Gas Code ANSI Z223.1.
• Local codes regarding installation vary greatle from one area to
another. This equipment is to be installed to comply with the
applicable federal, state or local codes.
The installation instructions contained herein are for the use of
qualified installation and service personnel only. Installation or
service by other than qualified personnel may result in damage to
the appliance and/or injury to the operator.
FAILURE TO COMPLY WITH INSTALLATION INSTRUCTION
OR IMPROPER INSTALLATION WILL VOID WARRANTY AND
RESPONSIBLITIES OF THE MANUFACTURE.
The National Fire Protection Association, Inc states in its NFPA
96 latest edition that local codes are the "authority having
jurisdiction" when it comes to installation requirements for
equipment. Therefore, installations should comply with all local
codes.
1.3 UNPACKAGING
• Remove the appliance from the packaging and take away the
protective film that covers the appliance's external panels care-
fully to avoid leaving any trace of glue. If necessary remove the
glue using an a non-corrosive solvent, rinsing it off and drying
carefully.
• Dispose of packaging material in compliance with the regulations
in force in the country where the product is to be used.
15
USA
5958 932 00
F
F
E
C
ø D
2D
A
G
*
Tmax=662˚F
SILICONE
B
H
G
H
A
G
Tmax=662˚F
9 feet MAX
*
SILICONE
F
C
H
F
E
B
G
H
Tmax=932˚F
ø D
2D
*
G
C
H
B
F
F
H
CONSTRUCTION TYPE
B13
CONSTRUCTION TYPE
B13
CONSTRUCTION TYPE
A3
DISCHARGE TO THE OUTSIDE OR CENTRAL FLUE WITH
SHROUD
DISCHARGE WITH SHROUD UNDER EXTRACTOR HOOD
DIRECT UNDUCTED DISCHARGE UNDER EXTRACTOR
HOOD
1a 1b
1c
KEY:
A: Cam / draught damper accessory F: Conical connections for single outlet (supplied)
(to be ordered from manufacturer) (always install)
B: Boiler combusted gas discharge G: Fixing screws (supplied);
C: Oven chamber convector combusted gas discharge *: Commercial extension pipes (not supplied)
E: Adapter ring for commercial ducts SILICONE: Apply silicone sealant between contact surfaces
(to be ordered from manufacturer) H: Gasket (supplied)
3.2 INSTALLATION OF ACCESSORIES
Accessories can be easily installed by following the figures below
together with the relative key.
The screw holes for fixing accessories "A" and "F" are 0.14"(3.5
mm) in diameter and they must be drilled in-situ on the oven cover
in correspondence with the punch marks.
3.3 WARNINGS REGARDING THE FLUING SYSTEM
Before installation check, on the basis of the contents of the
reference standard, to ensure that the volume aspirated by the
fumes exhausting system is greater than the volume of combusted
gas produced by the appliance (see point 1.1).
If the solution of combusted gas discharge under an extractor
hood is chosen, observe the distance (shown in the figure)
between the top of the discharge pipe and the lowest point of the
hood filters. This distance is defined on the basis of discharge
pipe diameter "D".
In the case of discharge direction to the outside or into a central
flue (Fig. "1c"), the discharge ducts must NOT present an overall
length in excess of 762"(3 metres), must NOT have any reductions
in diameter, and must be subjected to periodic inspection and,
when necessary, cleaning.
Warning:
Since combusted gas (see figure) can reach very
high temperatures, check the heat resistant properties of
extension ducts if fitted and the filters in the extractor hood
to ensure the materials are compatible with the temperature
conditions. In addition, periodically check the condition of
the filters which, if excessively fouled with fat and dirt, will
reduce the efficiency of the suction system and may catch
fire.
4. ELECTRICAL CONNECTION
A fused disconnect switch or main circuit breaker (customer
furnished) MUST be installed in the electric supply line for the
appliance. It is recommended that this switch/circuit breaker
have lockout/tagout capability. Before making any electrical
connections to this appliance, check that the power supply is
adequate for the voltage, amperage, and phase requirements
on the rating plate.
A safety cutout switch of suitable capacity with a contact
breaking distance of at least 3 mm must be fitted upstream of
the appliance.
The cutout switch must be installed near the appliance in the
permanent electrical system of the premises.
The appliance must be electrically grounded in accordance
with local codes, or in the absence of local codes, with the
National Electrical Code, ANSI/NFPA 70, or the Canadian
Electrical Code, CSA C22.2, as applicable.
The grounding conductor must therefore be connected to the
terminal marked Gon the connection terminal board. The
appliance must also be connected to an earth grounding
system.
This connection is made using the stop screw marked E
located on the outside of the appliance near the power cable
inlet.
The grounding wire must have a minimum cross-section of
8 AWG (10 mm
2
).
RATING PLATE
16
USA
5958 932 00
4.1 INSTALLING THE POWER SUPPLY CABLE
To access the power supply cable connection terminal board,
proceed as follows:
Model 6 - 10 - 20 GN
Remove the left side panel.
Connect the power supply cable to the terminal board accord-
ing to the instructions given in the wiring diagram and fasten the
power supply cable by means of strain-relief fitting (not furnished
with the oven).
Failure to comply with safety rules and regulations relieves
the manufacturer of all liability.
The manufacturer requires when stacking units each appliance
have its own branch circuit protection. An air-o-steam® unit
stacked with an air-o-chill® unit should have a separate protection
for the upper and lower units.
5. WATER MAINS CONNECTION
(Refer to the installation diagrams at the beginning of this book-
let).
This equipment is to be installed to comply with the applicable
Federal, State, Local plumbing codes, or the Basic Plumbing
Code of the Building Officials and Code Administrators
International Inc. (BOCA) and Food Service Sanitation Manual
of the Food and Drug Administration (FDA).
The appliance is fitted with two separate water inlets ("B" and "N").
The water lines supplying both inlets must be fitted with a
mechanical filter and shut-off valve (keeping with local plumbing
codes).
Before fitting the filters allow the water to flow out for sufficient time
to flush any solid particles from the piping.
5.1 WATER SUPPLY CONNECTIONS
5.1.1 WATER INLET "N".
Attention
The water supply pipe (not supplied) must have a 3/4" dia (20
mm) pipe and must be without elbow fittings.
The steam condensation system must be connected to a cold
quality water supply in keeping with local plumbing codes, with
the following characteristics:
- total hardness: up to 400ppm (40°fH) .
- pressure: 22 to 36 psi (150-250 kPa); higher pressure
values result in increased water consumption.
Note:
To check correct water installation, make sure the rotating wash
arm (CLEANING SYSTEM) does not turn below 100 rpm (120
max).
5.1.2 WATER INLET "B".
(water pipe supplied)
The steam production system must be connected to a quality
water supply in keeping with local plumbing codes, with the
following characteristics:
- total hardness:
5 - 50ppm (0.5 - 5 °fH) to reduce the
build-up of lime-scale inside the boiler.
On request the oven is supplied with an optional water softener
with automatic regeneration which must be installed on inlet line
"B". This device can also be fitted with an optional resin sanitizer
kit.
- pressure: 22 to 36 psi (150-250 kPa); higher pressure
values result in increased water consumption.
- chlorine ion concentration (Cl -): not more than ~10 ppm
(acceptable value) to avoid damaging the oven's internal steel
parts.
- pH: over 7.
The oven can be equipped with an optional special filtration unit
which is installed on inlet line "B". This unit also acts as a water
softener, reducing water hardness to less than
50ppm (5 °fH)
(optimum value).
- electrical conductivity: 50 to 2000 µS/cm (68°F)(20°C).
Important: The use of water treatment systems featuring
technology that differs from that of the systems supplied by the
manufacturer is prohibited and will automatically invalidate the
warranty.
The use of dosing systems designed to prevent the build-
up of lime-scale in pipes (i.e. polyphosphate dosing
systems) is also prohibited since such systems may impair
the performance of the appliance.
5.2 WATER DRAIN SYSTEM
The oven is supplied with an air-break system to prevent any
backflow from the drainage system from reaching the oven’s in-
ternal circuits and the cooking chamber. The presence of this
system means that the drain pipe can be connected directly to
the mains drainage system or routed to a floor gulley with grat-
ing.
The flexible drainage hose or rigid pipe can be directed to the
side or rear of the appliance if the oven is not positioned against
a wall; this line must not be directed towards the front of the appli-
ance to prevent interference with roll-in grid racks. The drainage
pipe internal diameter must be no smaller than the oven drain
outlet (1 1/4"), no longer than 3 feet (1 metre) and must resist
temperatures of up to at least 212°F (100°C). Avoid restrictions
in the case of flexible hose pipes, do not fit elbows on metal
pipes anywhere along the drainage line. Also avoid horizontal
sections in which water might collect (minimum gradient 5%).
WARING: BLOCKING THE DRAIN IS HAZARDOUS.
Note:
If water flows out of the air-break system (near the oven drainage
pipe) remove any obstructions clogging the drain.
This water outlet pipe should be extended and directed to the
side or rear of the appliance if the oven is not positioned against
a wall; this line must not be directed towards the front of the appli-
ance to prevent interference with roll-in grid racks.
max 39"37
max 212˚F
17
USA
5958 932 00
6. GAS CONNECTION
6.1 WARNINGS
Make sure the appliance is set up for the type of gas with
which it will be supplied.
The gas inlet connector is yellow in colour.
Before installing consult your local gas utility company to check
the compatibility between the available supply and the
consumption of the appliance.
Before hooking up the appliance to the gas pipeline remove the
plastic protective plug from the gas connector.
Fit a rapid gas shut-off cock upline from the appliance in an
easily accessible position.
On completion of installation, use soapy water to check gas
connections for leaks.
It is not possible to adjust the combustion air ventilation
capacity.
If the appliance is hooked up to a supply with a different gas type
with respect to the factory setting, after making the necessary
changes check that it is working correctly (see heading 8
"Operation Check").
6.2 NOMINAL HEAT OUTPUT
For data concerning the nominal heat output refer to "Technical
Data" in Table 1.
This parameter is determined by the pressure of the gas supply
and the diameter of the gas valve diaphragm (nozzle).
The appliance nominal heat output must always be checked (by
the authorised installer or by the gas utility company), both in the
case of new installations or following maintenance work.
It is strictly prohibited to make changes to the nominal heat
output.
6.3 CHECKING THE SUPPLY PRESSURE (Fig. 2a)
The gas supply pressure must be measured upline from the gas
shut-off cock with the appliance operating, using a pressure
gauge with minimum resolution of 0.1 mbar and proceeding as
outlined below:
1) Remove the left hand side panel to gain access to the gas
valve;
2) Loosen sealing screw "C" from the gas valve pressure test
point and connect the pressure gauge hose in its place;
3) Open the gas shut-off cock;
4) Start a mixed cooking cycle (see "Instructions for use") in
such a way that all the burners can be lit;
5) Check that the pressure reading is within the values given in
the following table:
GAS TYPE PRESSURE (MBAR)
Nom. Min. Max.
NATURAL
PROPANE
7"wc (17,4mbar) 3"wc (8,7mbar) 10"wc (26,1mbar)
11"wc (27,4mbar) 8"wc (19,9mbar) 13"wc (32,3,4mbar)
If the values are not within the values shown in the table the
appliance will not function.
In this case inform your gas utility company of the problem;
6) Once you have measured the supply pressure stop the cooking
cycle and close the gas shut-off cock.
7) Disconnect the pressure gauge and carefully refit and tighten
sealing screw "C";
8) Refit the previously removed side panel.
C
E
neywell_sigma
D
E1
2a
7. SAFETY DEVICES
The appliance is fitted with the following safety devices:
- Fuses (see electrical circuit diagram) located behind the control
panel.
To change a fuse unscrew and remove the retainer cap and
replace the blown fuse with an identically rated component; the
fuse rating value is specified on the relative dataplate.
- Oven chamber safety thermostat with manual reset, located
behind the control panel; when this device trips, convection
heating power is disconnected.
Notice: CONTACT YOUR AUTHORIZED SERVICE COMPANY
TO PERFORM MANINTENANCE AND REPAIRS.
- Automatic reset thermal protection inside the cavity fan
motor: this device trips in the event of overheating of the cavity
fan motor; this cut-out protects the appliance by disconnecting
the power supply to the main PC board and an error message is
display EFUN.
8. OPERATION CHECK
- Switch on the appliance in accordance with the following
section "Instructions for use".
- With the aid of the Instruction Booklet, explain operation,
routine maintenance, and cleaning to the user.
Important
:
- Exercise due care since certain areas of the oven exterior
become hot during use.
- Do not cover the exhaust outlets on top of the appliance.
9. SERVICING
All components requiring routine maintenance may be easily
reached by opening the control panel, removing the left side
panel, or removing the rear panel.
Danger: Live voltage is present with panels removed and unit
switch on. Exercise extreme caution when work with live voltage.
NOTICE: Using any parts other than OEM original spare parts
relieves the manufacturer of all warranty and liability.
18
USA
5958 932 00
10. TROUBLESHOOTING
Malfunctions may occur even when the appliance is used correctly.
Burner fails to light (message "burn" appears on display TM ,
see "Instructions for use" chapter 5).
Possible causes:
- The ignition electrode is incorrectly positioned or the insulation
is damaged. The optimum distance from the outside of the
electrode to the boiler burner is approximately 5 mm(8mm Mod.
20 GN1/1), while the equivalent distance for the convector burner
is approximately 4.5 mm.
- The ignition / flame control device is damaged.
- The ignition electrode high tension lead is broken or shorting to
ground.
- Insufficient gas pressure.
- Faulty gas valve.
- Burner fan unit damaged, insufficient air pressure in combustion
chamber.
- Electronic control panel is damaged.
- Blown fuse, check electrical diagram.
- Oven chamber temperature probe damaged (error EPt1 - see
"Instructions for use" chapter 5).
- Temperature limiter trip.
- High room air humidity (condensation): ventilate the kitchen.
Burner flame extinguishes (message "burn" appears on display
TM, see "Instructions for use" chapter 5).
Possible causes:
- Power supply polarity (Phase/Neutral) inverted.
- Electrical supply to oven is "Phase/Phase" type. In this case fit
the special "Transformer Kit" available from the manufacturer on
request.
- Faulty gas valve.
- Flame detector electrode incorrectly positioned or in open
circuit.
- Burner fan unit damaged (lockout situation).
- Flame control device damaged
- High room air humidity (condensation): ventilate the kitchen.
Oven chamber temperature thermostat control is incorrect.
Possible causes:
- Electronic control panel faulty.
- Oven chamber temperature probe is dirty, faulty, or interrupted,
see error EPt1 (see "Instructions for use" chapter 5).
Oven fails to turn on. Possible causes:
- Electronic control panel is damaged.
- Fuse F2 blown due to damaged control circuit components.
Oven chamber lamps damaged
CAUTION: Before changing oven chamber lamps switch off the
appliance.
11. LAYOUT OF MAIN COMPONENTS
(All work inside the appliance must be carried out exclusively
by a trained installer authorised by the manufacturer)
Removing the control panel provides access to the following
components:
Danger: Live voltage is present with panels removed and unit
switch on. Exercise extreme caution when work with live voltage.
- Electronic circuit boards
- Oven chamber temperature limit thermostat
- Fuses
- Door microswitch
- Oven chamber lamp transformer
- Geared motor for the oven chamber pressure relief butterfly
valve.
WARNING: Before servicing unit switch off power at the main
circuit breaker and place a red tag on the breaker to indicate work
is being done on the circuit.
Remove the appliance left hand side panel to gain access to all
the other components.
19
USA
5958 932 00
Before switching on the appliance, read this instruction booklet
carefully because it contains important information concerning
correct use of the appliance. If you require further information
about the oven's features and cooking performance, consult your
local dealer.
ANY POTENTIAL USER OF THE EQUIPMENT SHOULD BE
TRAINED IN SAFE AND CORRECT OPERATING PROCEDURES.
This appliance is intended for industrial use only and is specifically
designed to cook food. Any other use will be considered "improper
use" and will void the warranty and manufacturer liability.
• Do not place pans or utensils on top of the oven. Avoid
obstructing the fumes and steam exhaust outlets.
• Periodically the appliance should undergo a general inspection.
For this purpose we recommend taking out a service contract.
• The core temperature probe is a precision instrument and must
be handled with care. Avoid knocks, do not apply excessive force
when inserting the probe, and do not pull on the lead (take care
particularly when using roll-in racks). The warranty e does not
cover damage to the temperature probe caused by improper
use.
• When using the mixed cooking cycle, do not exceed cooking
temperatures of 392-410°F. Higher temperatures might impair the
performance of the oven chamber seals.
• When placing food in the oven leave a gap of at least 1.5"(40
mm) between each pan to facilitate circulation of hot air.
• Do not add salt to foods when inside the oven chamber,
particularly during cooking cycles with humidification.
• Do not cook with flammable liquids such as alcoholic spirits.
Attention
Cooking containers can not be inserted at a height greater than
63" (1.6m) from the level where the user operate.
If supporting accessories other than the original ones are to be
used, do not exceed the above specified height since this
could result a spill hazard caused by hot cooking liquids
(sauces, oil, melted fat, etc...) contained in the uppermost pans,
which are not visible during handling operations.
1. OPENING THE OVEN DOOR
The oven is equipped with a safety system to protect the user
against scalding steam when the door is opened wide. Proceed
as follows, depending on the model:
1.1 6- AND 10-GRID MODELS
Important
! Risk of burns.
Open the door with due care when the appliance is hot.
a) Turn the oven door handle in either direction as far as it will go.
The door opens slightly and is stopped by the door safety
device.
If there is a cooking program in progress it will be interrupted but
will continue when door is closed.
b) Release the handle, then turn handle in either either direction as
far as it will go to open the door.
1.2 20-GRID MODELS
Important
! Risk of burns.
Open the door with due care when the appliance is hot.
a) Turn the oven door handle counter-clockwise as far as it will
go.
The door opens slightly and is stopped by the door safety
device.
If there is a cooking program in progress it will be interrupted but
will continue when door is closed.
b) Turn the door handle to the vertical position and then pull
outwards, the door will offer light resistance and then open
completely.
2. CLOSING THE OVEN DOOR
2.1 6- AND 10-GRID MODELS
To close the oven door press it until it locks.
2.2 20-GRID MODELS
a) Turn the door handle counter-clockwise as far as it will go and
press the door closed against the oven.
b) Keeping the door pressed closed, lock it by turning the handle
to the vertical position.
III. INSTRUCTIONS FOR USE
20
USA
5958 932 00
3. DESCRIPTION OF THE CONTROL PANEL
3.1 INTRODUCTION
To aid understanding of the operation of the oven, find the folding
double page showing the control panel for your model among
those included at the back of this handbook and then open it out
and keep it open while reading this section.
The following headings describe all the functions available on the
various models in the range.
Some functions are shared by all models, others are available
on specific models.
3.2 MAIN CONTROLS
Main switch
Cooking cycle/program start/stop.
3.3 MAIN COOKING MODES
Air-convection cycle: To roast and gratin with a maximum
temperature of 572°F(300°C) (for 10 minutes max, 483°...
572°F)(251...300°C).
Mixed cycle: superheated steam. Uses the oven chamber heaters
and steam generation system at the same time to keep food soft
(maximum temperature 482°F)(250°C).
Steaming cycle: ideal for steam cooking (operating temperature
automatically set at 212°F)(100°C).
You can set low temperature steam for gentle cooking of foods
in vacuum packs and for thawing (temperature from 77°F to
210°F)(25° to 99°C).
Displaying the humidity value: allows you to display the humidity
level of the air-convection, mixed and regeneration cycles.
Digital thermometer/thermostat: to control the temperature in
the oven chamber.
Timer to control cooking time.
Digital thermometer/thermostat: to control product core tem-
perature.
3.4 SPECIAL COOKING MODES
Utilities
Functions useful for the type of cooking to be executed.
Pause phase: set a time in this mode to delay the start of cooking
programs or to set a pause interval between two cooking cycles
(e.g. for dough proving).
Regeneration cycle: gives ideal humidity conditions for rapid
heating of products to be regenerated (maximum temperature
482°F)(250°C).
The regeneration program is composed of a single phase with the
following characteristics:
- a special cycle with controlled humidity of 60 % (adjustable if
required);
- preset temperature of 356°F (180°C)(can be altered if necessary);
- use of maximum power;
- a preset time of 30 minutes (adjustable if required) and once
started, remains active with door open or closed.
DANGER: CAVITY FAN AND STEAM WILL CONTINUE TO
OPERATE WHEN DOOR IS OPEN. WHEN IN
REGENERATION CYCLE. OPEN DOOR SLOWLY TO
AVOID THE RISK OF BURNS.
Alternatively to the set cooking time it can also accept Cont
cooking time or the core probe.
HOLD
Cook and hold cycle: for long slow cooking, typically for meat
(
large piece of meat for roasting).
It can be used in combination with convection, mixed, steam
and regeneration modes.
HACCP
HACCP: serves to record the cooking program in compliance with
HACCP standards (Hazard Analysis and Critical Control
Points). Depending on the system requested you can record
cooking data on a dedicated printer or directly on a PC.
Clean Cycle: semiautomatic oven cleaning cycle (see section 7.
CARE AND MAINTENANCE).
21
USA
5958 932 00
Low speed cycle (fan): for delicate cooking such as for baking
cakes. Can be combined with any other cycle.
Reduced power cycle (heating): for delicate cooking such as for
baking cakes. Can be combined with any other cycle.
Cooking with ECO-DELTA: for cooking large pieces of food (5kg
and above, e.g. whole turkey, leg of pork, etc.).
In this cooking mode a temperature setting of between 1°C and
120°C is chosen.
In this case, cooking is moderate and long, because the CHAM-
BER temperature is automatically adjusted according to that
inside the food (CORE PROBE), maintaining a constant differ-
ence (ECO-DELTA) between them, from start to end of cooking.
E.g:
COOKING: START ...... END
ECO-DELTA = 80°... 80...80... 80... 80°C (set)
CORE PROBE = 10°... 11...12... 40... 60°C (set)
CHAMBER = 90°... 91...92... 120... 140°C
(result)
Air-convection cycle with oven chamber vent open: suitable
for very dry cooking cycles; allows evacuation of humidity when
necessary (maximum temperature 572°F)(300°C).
Door open indicator LED.
Limescale LED: when this LED starts flashing the boiler needs to
be descaled. Follow the instructions in section 7.
Boiler status LED:
- LED off: boiler ready;
- LED flashing: boiler filling or no water. Make sure the oven
water supply is working!
Cooking parameter adjustment: allows adjustment of cooking
values (humidity, temperature and time).
3.5 ADDITIONAL FUNCTIONS
Set of controls for management of the programs library:
control keys to store, edit or delete cooking programs.
Program selector : to find and select the cooking programs stored
in the memory.
Manual water injection into cooking chamber: serves to boost
humidity levels during the cooking cycle.
Boiler manual water draining: press this button to drain the water
from the boiler.
Important
! To prevent the build-up of lime-scale inside the
boiler:
Make sure the water supply corresponds with the required
characteristics - see Installation.
Always empty the boiler at the end of each day.
Rapid oven cooling: useful for passing from one type of cooking to
another that requires a lower temperature; it allows the fan to run and
automatic water (TS < 356°F)(180°C) injection even when oven
door is open.
Important
! Risk of burns.
Open the door with due care when the appliance is hot.
Before using the oven check that:
- the external safety electric switch is on;
- the water and gas supply valve is open;
- the fumes and steam discharge outlets are not blocked.
/