Verstellbereiche min./max.
Femureinstellbereich: ca.  cm
Unterschenkel einstellbereich: ca.  cm
Genauigkeit Messwerte
Winkelmesser im Messbereich: von  ° bis + °
Genauigkeit: +/ °
Gewicht:  kg
Materialien: ABS, POM, PUR, PA, FR, Aluminium, Edelstahl,
Messing
MPG: Klasse IIa
Konform zu:
//EEC //EG
IEC : +A: +A: S <.
IEC : S >.
IEC :
IEC :
IEC : S >.
IEC :
IEC :
EN ISO :
ANSI/UL  S <.
CAN/CSA C. No. .M S <.
ANSI AAMI ES  st Edition S >.
CAN CSA . No.  S >.
EMV
Elektromagnetische Verträglichkeit
IEC : S <.
IEC : S >.
Hergestellt unter Anwendung von: EN ISO : +AC:
Umgebungsbedingungen Lagerung, Transport
Umgebungs temperatur:
Relative Luftfeuchtigkeit:
Luftdruck:
 °C bis + °C
bei  °C bis  % ohne Kondensation
 hPa bis  hPa
Umgebungsbedingungen Betrieb
Umgebungs temperatur:
Relative Luftfeuchtigkeit:
Luftdruck:
+ °C bis + °C
 % bis  %
 hPa bis  hPa
______________________________
Technische Änderungen vorbehalten. /
ORMBS-12006_Artromot_K1_Comfort_2012_rz.indb 27 18.05.12 17:27

Deutsch
Konformitätserklärung
Geß den Bestimmungen der EG Richtlinie über
Medizinprodukte //EWG vom .. für
Medizinprodukte, erklärt die Firma
ORMED GmbH
Merzhauser Straße 
D Freiburg
dass die Produkte der Produktlinie
ARTROMOT® gemäß Anhang
mit der Richtlinie //EWG vom .. Anhang II
sowie den grundlegenden Anforderungen des Anhang I
übereinstimmen.
Bezug nehmend auf die Regel  der Richtlinie //EWG
handelt es sich um ein Produkt der Risikoklasse IIa.
Benannte Stelle:
DQS Medizinprodukte GmbH
AugustSchanzStraße 
 Frankfurt am Main

Freiburg, den . März 

 Qualitätsmanagement Beauftragter QMB
 Bernhard Krohne 
Dieses Zertifikat ist gültig bis zum Ablauf des bezugsnehmenden Zertifikats.
Zertifikat abzurufen unter: https://de.dqsul.com/kunden/kundendatenbank.html
Anhang:
ARTROMOT®SPRO
ARTROMOT®S
ARTROMOT®S Comfort
ARTROMOT® ACTIVEK
ARTROMOT®K
ARTROMOT®K
ARTROMOT®KPRO
ARTROMOT®KPRO Chip
ARTROMOT®K
ARTROMOT®K
ARTROMOT®SP
ARTROMOT®SP
ARTROMOT®E
ARTROMOT®E compact
ORMBS-12006_Artromot_K1_Comfort_2012_rz.indb 35 18.05.12 17:27

Contents
Device description ARTROMOT®K III
Symbol overview ARTROMOT®K V
Figures ARTROMOT®K VIII
. How to use the CPM device 
. Fields of application
. Therapy objectives 
. Indications 
. Contraindications 
. ARTROMOT®K description 
. Description of the device components 
. Description of the programming unit 
. Explanation of symbols 
. Explanation of symbols connections and nameplate 
. Safety information
. Adjusting the device 
. Connecting the device, performance check
.Connecting the external muscle stimulator ¹ 
.Adjusting the device to the femur length 
. Adapting the leg support assemblies/footplate 
. Setting the treatment values 
. General information on programming ARTROMOT®K
.Programming ARTROMOT®K standard models 
.Treatment value details  standard models 
.Programming ARTROMOT®K Comfort models 
.Protocol details  Comfort models
. Care, Maintenance 
. Care 
.Maintenance fuse replacement 
.. Transport 
. Environmental protection statement 
. Specifications 
. IEC : and IEC : 
. Electromagnetic emissions
. Electromagnetic immunity 
. Recommended separation distances 
. How to reach us 
. Technical Service 
. Technical Hotline 
. Shipment 
. Spare parts
. Declaration of conformity
ORMBS-12006_Artromot_K1_Comfort_2012_rz.indb 36 18.05.12 17:27

English
. How to use the CPM device
. Fields of application
ARTROMOT®K is a motoroperated
Continuous Passive Motion CPM device
used to mobilize knee and hip joints.
Suitable for use in hospitals, clinics,
general practices and rental services, it is
an important supplement to medical and
therapeutic treatment.
. Therapy objectives
CPM therapy with ARTROMOT®K is
mainly used to prevent the negative eects
of immobilization, to allow patients to
regain painless mobility of joints at an early
stage and to promote healing and achieve
a positive functional result.
Other objectives of therapy include:
improvement of joint metabolism
prevention of joint stiness
promotion of the regeneration and heal
ing of cartilage and damaged ligaments
faster hematoma/fluid resorption
improved lymph and blood circulation
thrombosis and embolism prophylaxis
. Indications
The CPM device is indicated in the treat
ment of most injuries and diseases of
the knee and hip joints as well as in the
postoperative treatment after knee and
hip joint surgery. Examples:
joint distortion and contusion
arthrotomy and arthroscopy procedures
in combination with synovectomy,
arthrolysis or other intraarticular
interventions
mobilization of joints in anesthetized
patients
operative treatment of fractures, pseu
doarthrosis and osteotomy
cruciate ligament replacement or
reconstruction
endoprosthetic implant
. Contraindications
Do NOT use ARTROMOT®K on patients
with:
acute inflammatory processes in the
joints, unless on the order of a physician
spastic paralysis
unstable osteosynthesis
ORMBS-12006_Artromot_K1_Comfort_2012_rz.indb 37 18.05.12 17:27

. ARTROMOT®-K description
The motorized CPM device permits exten
sion and flexion of the knee joint in the
range of °/°/°, and of the hip joint in
the range of °/°/°.
These are some of the outstanding
ARTROMOT®K features:
anatomically correct setup
physiological movements
programming unit for precise adjust
ment of patientspecific therapy
parameters
symbols for easy operation of the pro
gramming unit
programmed therapy parameters saved
to chip card
Biocompatibility
The parts of the ARTROMOT®K device
that come in contact with the patient dur
ing the intended use, are designed to fulfill
the biocompatibility requirements of the
applicable standards.
.Description of the
device components
Note: Please fold out page III!
. Thigh support assembly
. Clamping lever to adjust the height of
the thigh support assembly
. Thigh length scale
femur length scale
. Thigh length fixation screws
femur length
. Knee hinge
. Calf support assembly
. Clamping lever to adjust the height of
the calf support assembly
. Calf length fixation screws
tibia length
. Calf length scale tibia length scale
. Strap to secure the foot to the footplate
. Footplate
. Footplate angle fixation screw
. Clamping lever to adjust footplate
rotation and level and to remove the
footplate
. Connection for ARTROSTIM®
FOCUS®plus control cable²
. Connection for programming unit
. Connection for power cord
. Fuse cap
. Power switch ON/OFF
. Nameplate
. Programming unit
. Patient chip car
. Compartment for storage of
programming unit
¹ ARTROMOT®K devices with patient
chip card only.
² ARTROMOT®K Comfort devices only.
ORMBS-12006_Artromot_K1_Comfort_2012_rz.indb 38 18.05.12 17:27

English
patient chip card¹
selected angle of
the CPM device
therapy timer
set flexion value
parameter keys
MENU key
START key
STOP key
“” minus key
“+” plus key
selected direction
of motion
set extension
value
selected therapy
protocol
¹ ARTROMOT®K devices
with patient chip card only.
. Description of the programming unit
.. Programming unit in normal mode
ORMBS-12006_Artromot_K1_Comfort_2012_rz.indb 39 18.05.12 17:27

set angle of
the CPM device
set flexion value
parameters
available for
selection,
corres ponding
selection keys
set extension
value
selected
MENU level
set value of
selected function
here: flexion angle
selected parameter
here: flexion
selected
function
.. Programming unit in MENU selection mode
.. Programming unit in programming mode
ORMBS-12006_Artromot_K1_Comfort_2012_rz.indb 40 18.05.12 17:27

English
. Explanation of symbols
Standard protocols:
extension
stretching the knee
flexion
bending the knee
speed
warm up protocol
extension pause
flexion pause
therapy timer
reverse on load
feature for patient safety
transport setting
new patient
total therapy time
service menu
Comfort protocols:
stretch extension
stretch flexion
workout protocol
Comfort protocol
EROM
repeat extension
EROM
repeat flexion
EMS control
therapy documentation
Also refer to symbol overview on page V / VI !
ORMBS-12006_Artromot_K1_Comfort_2012_rz.indb 41 18.05.12 17:27

alternating current
for serial numbers < ,:
protection class I equipment. The medical device must be connected to a
system with protective earth conductor!
for serial numbers > ,:
protection class II equipment. The medical device has a double or reinforced
insulation.
type B applied part
power switch OFF
power switch ON
The number next to this factory symbol is the year of manufacture
The name next to this factory symbol is the manufacturer
The number next to this symbol is the article reference number
Device complies with Council Directive //EEC about medical devices,
tested and approved by DQS Medizinprodukte GmbH
The number next to this symbol is the serial number
m
Caution! Observe warnings set forth in operation manual!
Observe Operation Manual
Do not dispose with unsorted municipal waste
Protect from moisture
. Explanation of symbols (connections and nameplate)
ORMBS-12006_Artromot_K1_Comfort_2012_rz.indb 42 18.05.12 17:27

English
IP
The IP rating indicates the level of protection and thus the suitability of the
device for use under dierent ambient conditions.
The rating IP means:
 is the level of protection against contact and solid objects
The digit  means:
 Protection from contact: protected from contact with a finger
 Protection against foreign object: protected against solid foreign object
diameter of . mm and greater
 indicates the degree of protection against water
The digit  means: protection against vertically falling water drops
Warning! Depending on the device settings, the moving parts of the device
present pinch points! Pay particular attention to small children and babies!
ORMBS-12006_Artromot_K1_Comfort_2012_rz.indb 43 18.05.12 17:27
. Safety information
Introduction and definitions
Read the safety statements before use of
the CPM device. The safety statements are
classified as follows:
m Danger!
Indicates an imminent hazard. If not
avoided, this hazard will result in death
or serious injury.
m Warning!
Indicates a hazard. If not avoided, this
hazard can result in death or serious
injury.
m Caution!
Indicates a potential hazard. If not
avoided, this hazard can result in minor
personal injury and/or product/property
damage.
Safety information
m Danger!
Explosion hazard 
ARTROMOT®K is not designed for use
in areas where an explosion hazard may
occur. An explosion hazard may result
from the use of flammable anesthetics,
skin cleansing agents and disinfectants.
m Warning!
Patient hazard 
Only authorized individuals
are allowed to operate the
ARTROMOT®K device. Indi vi duals
are authorized after receiving train
ing in the operation of the device and
reading this operation manual.
Before using the device, the ope rator
must ascertain that it is in correct
working order and operating condi
tion. In particular, the cables and
connectors must be checked for signs
of damage. Damaged parts must be
replaced immediately, before use.
Before therapy, a test run consist
ing of several exercise cycles must
be completed, first without and then
with the patient. Check that all fixa
tion screws are tightened.
Stop therapy immediately, when you
have doubts about the device set
tings and/or the therapy protocol.
ORMBS-12006_Artromot_K1_Comfort_2012_rz.indb 44 18.05.12 17:27

English
m Warning!
Patient hazard 
It is important that the patient’s
position is anatomically correct.
Therefore, carefully verify the follow
ing settings/positions:
. femur length
. knee joint axis
. tibia length and leg rotation
. leg support assemblies
Movements must not cause pain or
irritation.
Patients must be fully conscious
while being instructed in the use of
the CPM device and during therapy.
Only the responsible physician or
therapist is able and allowed to
choose the therapy parameters and
protocols to use. It is the physician’s
or therapist’s decision whether or not
to use the CPM device on a specific
patient.
The patient must be familiar with the
functions of the ARTROMOT®K
programming unit and the unit must
be within easy reach of the patient,
allowing him or her to stop therapy, if
needed. Patients unable to operate
the programming unit, e.g. paralytic
patients, must never be left unatten
ded during therapy.
After data storage, write the patient’s
name on the patient chip card. The
card should only be used for this pa
tient. If the patient chip card is used
for another patient, be sure to delete
the previous patient’s data from the
card first see: section . Program
ming: “New Patient.
Use original chip cards only
Any accessories used with
ARTROMOT®K must first be ap
proved by DJO Global.
Modifications to the medical device
described in this document without
the manufacturer’s written consent is
prohibited.
The simultaneous treatment of both
legs by simultaneous use of two CPM
devices is not permitted because the
motion elements might interfere
with each other.
Stability of the physiotherapy unit
must always be ensured while it is in
use. The ARTROMOTK must only
be set up on surfaces that guaran
tee its stability. Very soft or instable
surfaces such as waterbeds are NOT
suitable.
Do not allow parts of the body or
objects such as blankets, cushions,
or cables to get caught in the mov
ing parts of the CPM device.
m Warning!
Extreme caution should be taken
when in use around small children
and babies! Sucient distance to the
device is mandatory for their safety!
Never leave the device unattended
when it is switched on! Switch the
device o and disconnect the power
line from the wall outlet!
After use, store the device in a safe
place! Ensure device stability also
during storage!
¹ ARTROMOT®K devices with
patient chip card only.
ORMBS-12006_Artromot_K1_Comfort_2012_rz.indb 45 18.05.12 17:27
m Warning!
Shock hazard 
Strictly observe the following warnings.
Failure to do so endangers the lives of
the patient, the user and other persons
involved.
Allow ARTROMOT®K to reach
room temperature before use. If the
device has been transported at tem
peratures below  °C/ °F, leave it
to dry at room temperature for about
 hours, until any condensation has
disappeared.
The ARTROMOT®K device must
only be operated in dry rooms.
When disconnecting the device from
the power line, remove the plug from
the wall outlet first, before discon
necting the cable from the device.
When connecting the device to other
equipment or when creating a medi
cal system, check that the sum of
leakage currents will not cause any
hazard. Please contact DJO Global,
if you have questions in this matter.
Do not use multiple portable socket
outlets MPSO to connect the device
to the power line. ARTROMOT®K
must be connected to a properly in
stalled wall outlet with a nonfused
earthed wire. Before connecting the
power cord, it must be completely
unrolled and placed such that it will
not get caught by the moving parts
of the device.
Before cleaning and service interven
tions, disconnect the device from the
power line by removing the power
cord from the wall outlet.
Liquids must not be allowed to enter
the CPM device or the programming
unit. If liquids have entered into the
devices, ARTROMOT®K must be
immediately checked by a service
technician, before it can be reused.
m Warning!
Equipment malfunction 
Magnetic and electrical fields are
capable of interfering with the proper
performance of the device. For this
reason make sure that all external
devices operated in the vicinity of the
CPM device comply with the relevant
EMC requirements. Xray equipment,
MRI devices and radio systems are
possible sources of interference as
they may emit higher levels of elec
tromagnetic radiation. Keep the CPM
device away from these devices and
verify its performance before use.
Refer repair and maintenance to
authorized persons.
Persons are authorized after training
by a specialist trained and commis
sioned by the manufacturer.
Route all cables below the device
frame to either side, ensuring that
they cannot get caught by the mo
ving parts during operation.
Inspect ARTROMOT®K for da mage
and loose connections at least once a
year. Damaged and worn parts must
immediately be replaced with original
spare parts by authorized sta.
m Caution!
Preventing chafing and pressure sores 
When your patient is adipose, very
tall or very short, be sure to prevent
chafing and pressure sores. Place the
leg concerned in a moderate abduction
position, if deemed appropriate.
ORMBS-12006_Artromot_K1_Comfort_2012_rz.indb 46 18.05.12 17:27

English
m Caution!
Equipment damage 
Check that the voltage and frequency
ratings of your local power line are
those indicated on the nameplate.
The leg support element withstands
a maximum continuous load of
 kg, S <, /  kg, S >,.
Do not allow any objects such as
blankets, cushions, or cables to get
caught in the moving parts of the
CPM device.
Do not expose the ARTROMOT®K
device to direct sunlight, because
some of the components may reach
inadmissibly high temperatures.
Furthermore, the device must be set
up at a safe distance from radiators to
prevent excessive temperature rises.
The presence of children, pets and
rodents does not normally impair the
functioning of the device. However,
avoid contamination of the device by
children or animals, from dust and
lint, and keep them at a safe distance
from the device. The safety state
ments set forth apply.
ORMBS-12006_Artromot_K1_Comfort_2012_rz.indb 47 18.05.12 17:27
. Adjusting the device
Note: For a better understanding of each
step, please fold out pages III and VIII.
.Connecting the device,
performance check
The equipment supplied includes these
items:
base unit, programming unit , patient
chip card   ARTROMOTK versions
with chip card only, power cord not
shown, operating instructions
. Connect the programming unit  to
the provided socket  by plugging it in
and closing the bayonet lock. With pa
tient chip card versions, insert the chip
card into the slot in the programming
unit
. Connect the power cord to socket 
of the device and mains plug to a wall
outlet with a nonfused earthed wire
 to  Volt, / Hz.
. Turn the power switch  on.
. Follow these steps to set the carriage to
the home position.
ARTROMOT®-K
without patient chip card
Press the MENU key on the pro gram ming
unit until you reach program level  stand
ard model or program level  Comfort
model.
Press the “New Patient” parameter key.
.
Press the START key. The CPM device au
tomatically enters the home position.
ARTROMOT®-K
with patient chip card
Initial adjustment for new patients Insert
the original patient chip card  into the
programming unit .
Press the MENU key on the pro gramming
unit until you reach program level  stand
ard model or program level  Comfort
model. Press the “New Patient” parameter
key.
Press the START key. The CPM device au
tomatically enters the home position.
Adjustment with programmed chip card
Insert the original patient chip card 
into the programming unit .
Press the START key.
The CPM device automatically enters the
home position.
Performance check
If the programming unit can be operated
as described above and ARTROMOT®K
enters the home position for home posi
tion values, refer to sections . and .,
the device has passed the performance
check.
The device also runs performance checks
regularly during operation. This is what
happens, if a problem is identified:
An audio signal sounds.
The device switches o immediately.
The message “ERR”, accompanied by a
code number e.g. ERR , appears on
the display.
In this situation, you may attempt to
restart the unit by turning it briefly o and
on again with the power switch. With the
unit switched o, check that all plugs are
correctly connected. Switch the unit on
again: if the error message persists, have
the unit inspected by a Service technician,
before using it again.
ORMBS-12006_Artromot_K1_Comfort_2012_rz.indb 48 18.05.12 17:27

English
.Connecting the external
muscle stimulator ¹
m Caution!
Patient hazard, equipment
malfunction 
Only the ARTROSTIM®FOCUS®
plus muscle stimulator with EN
 approval, manufactured by
DJO Global, may be connected to the
ARTROMOT®K device.
Use the “muscle stimulation” cable
part no. .. to connect the
muscle stimulator. Other cables are
not approved. The cable can be ordered
separately from DJO Global.
. Connect the jack plug to the
ARTROSTIM®FOCUS® plus muscle
stimulator.
. Connect the round plug to connector
 of the ARTROMOT®K and turn it a
short way clockwise to lock.
. Turn on ARTROMOT®K and then the
muscle stimulator.
Note!
For information on connecting and pro
gramming the muscle stimulator, refer
to the operation manual that comes
with the ARTROSTIM®FOCUS®plus.
.Adjusting the device
to the femur length
. Measure the length of the patient’s
thigh femur from the greater tro
chanter to the lateral knee joint cavity
Fig. A.
. Set the carriage to the home position
see ..
. Set the measured value at the femur
scale  of the carriage.
Loosen the two fixation screws .
Extend the scale  to the required
length.
Tighten the fixation screws  to set
the scale to the new length.
m Caution!
Equipment damage 
Do not attempt to extend the femur
scale beyond the stop.
¹ For control of an external muscle
stimulator an ARTROMOT®K
Comfort device and the corresponding
connector are required.
ORMBS-12006_Artromot_K1_Comfort_2012_rz.indb 49 18.05.12 17:27

. Adapting the leg support
assemblies/footplate
. Set the leg support assemblies and
the footplate , ,  to the expected
positions before accommodating the
patient.
Loosen fixation screws  to adjust
the footplate  to the length of the
patient’s lower leg Fig. C.
Loosen clamping lever  and adapt the
footplate’s rotation and height to the
patient Fig. D.
Loosen fixation screw  and adapt
the angle to the patient’s foot turn the
screw a few revolutions until the foot
plate can be easily adjusted.
For short patients you can reverse the
footplate’s bracket ° Fig. H to adapt
the footplate to shorter calves:
Loosen clamping lever  and
remove the footplate .
Loosen the fixation screws .
Reverse the bracket °.
Screw the footplate to the bracket
and tighten the clamping lever.
Note!
When reversing the footplate, ensure
that the pins below the clamping lever
engage with the recesses in the bracket.
To adjust the height of the support
assemblies for calf  and thigh ,
loosen clamping levers  and 
Figs. E/F.
. Place the patient’s leg on the carriage
and repeat the steps outlined under
 above to adjust the device to the
patient.
m Caution!
Equipment damage 
Cover the leg support assemblies
with disposable tissues when using
ARTROMOT®K immediately after sur
gery. This helps prevent discoloration.
m Caution!
Patient hazard 
Ensure that the rotational axes of
the CPM device and of the knee joint
coincide both in the vertical and in the
horizontal plane Fig. G.
Symbol :
Measurement of
the patient’s femur
length from the
grea ter trochanter to
the knee joint cavity.
Symbol :
Set the carriage to
the home position
see . and adjust
it to the measured
femur length.
Symbol :
Adjust height of calf
and thigh support
assemblies. Adjust
the footplate to the
height and length of
the lower leg.
ORMBS-12006_Artromot_K1_Comfort_2012_rz.indb 50 18.05.12 17:27

English
. Setting the treatment values
m Warning!
Patient hazard 
Before therapy, a test run consisting of
several exercise cycles must be com
pleted without the patient. Then repeat
the test run with the patient and check
that the movement does not cause any
pain.
Note!
See also . and . as well as page VIII !
.General information
on programming
ARTROMOT®-K
. You activate the programming mode by
briey pressing the MENU key on the
programming unit.
. The various treatment parameters and
functions are allocated to three stand
ard model or five Comfort model
programming levels four per level.
To be able to program a parameter you
will have to access the corresponding
programming level. This is also done
with the MENU key. With each key press
you advance one level. The code M, M,
etc. that appears in the middle of the
display indicates the programming level.
. You activate the treatment parameters
and functions with the four parameter
keys below the display. The symbols
above the four parameter keys indicate
the assigned parameters and functions.
This is what happens when you press
one of the parameter keys to select a
parameter:
The corresponding symbol appears on
the display in a larger format.
The set value is displayed.
The symbol above the parameter key
appears in reverse video.
. With the +/ keys plus/minus you
change the displayed value. When you
press and hold the key, the value will
change at a higher rate.
Some of the special functions will only
be enabled and disabled. This is done by
pressing the corresponding parameter
key or with the +/ keys. Activated
parameters are identified with a check
mark in the circle next to the symbol.
. Having programmed all parameters,
press the STOP key to save the values.
. Then press the START key to start
therapy.
Note!
Refer to sections . and . for a
description of the parameters.
To view the set parameter values,
press the corresponding parameter
key. However, this is only possible
when you press the STOP key first.
To prevent accidental changes of the
parameter settings, you can lock the
keys. To do so, simultaneously press
keys + and  for approx.  seconds.
Press both keys again for approx.
 seconds to unlock.
Selecting the “New Patient” function
will automatically delete the data on
the patient chip card. When you have
finished programming the unit and
press the STOP key, the settings will
automatically also be saved to the
patient chip card.
Emergency stop function:
ARTROMOT®K will stop immedi
ately, when any of the keys is pressed
during therapy. Patient treatment
can be resumed by pressing the
START key. The device will automati
cally change the direction.
ORMBS-12006_Artromot_K1_Comfort_2012_rz.indb 51 18.05.12 17:27

Patients with
a programmed chip card
Insert the chip card the patient is not
yet positioned on the CPM device.
Perform the mechanical adjustments of
the CPM device femur length, etc..
Position the patient on the CPM device
and press the START key to initiate
therapy.
.Programming
ARTROMOT®-K
standard models
Dierent programming levels are provided
to program the ARTROMOT®K Standard
models.
You change between levels by pressing the
MENU key.
The display always indicates on which level
you are.
The following treatment values, settings
and information can be entered/viewed
on the programming unit :
LEVEL :
extension
stretching the knee
flexion
bending the knee
− speed
− warm up protocol
LEVEL :
MENU
− extension pause
− flexion pause
− therapy timer
reverse on load
feature for patient safety
MENU
LEVEL :
− transport setting
− new patient
− total therapy time
− Service menu
Note!
While you adjust the extension/
flexion values, the CPM device will
move to the set range. This allows
you to easily and quickly determine
the ROM where the patient does not
experience pain.
S
pecial functions can be programmed
and retrieved with ARTROMOT®K
Comfort devices see sections . and
.
.
Only ARTROMOT®K chip card
models allow therapy protocols to be
saved to an inserted chip card.
ORMBS-12006_Artromot_K1_Comfort_2012_rz.indb 52 18.05.12 17:27
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149
  • Page 150 150
  • Page 151 151
  • Page 152 152
  • Page 153 153
  • Page 154 154
  • Page 155 155
  • Page 156 156
  • Page 157 157
  • Page 158 158
  • Page 159 159
  • Page 160 160
  • Page 161 161
  • Page 162 162
  • Page 163 163
  • Page 164 164
  • Page 165 165
  • Page 166 166
  • Page 167 167
  • Page 168 168
  • Page 169 169
  • Page 170 170
  • Page 171 171
  • Page 172 172
  • Page 173 173
  • Page 174 174
  • Page 175 175
  • Page 176 176
  • Page 177 177
  • Page 178 178
  • Page 179 179
  • Page 180 180
  • Page 181 181
  • Page 182 182
  • Page 183 183
  • Page 184 184
  • Page 185 185
  • Page 186 186
  • Page 187 187
  • Page 188 188
  • Page 189 189
  • Page 190 190
  • Page 191 191
  • Page 192 192
  • Page 193 193
  • Page 194 194
  • Page 195 195
  • Page 196 196
  • Page 197 197
  • Page 198 198
  • Page 199 199
  • Page 200 200
  • Page 201 201
  • Page 202 202
  • Page 203 203
  • Page 204 204
  • Page 205 205
  • Page 206 206
  • Page 207 207
  • Page 208 208
  • Page 209 209
  • Page 210 210
  • Page 211 211
  • Page 212 212
  • Page 213 213
  • Page 214 214
  • Page 215 215
  • Page 216 216
  • Page 217 217
  • Page 218 218
  • Page 219 219
  • Page 220 220
  • Page 221 221
  • Page 222 222
  • Page 223 223
  • Page 224 224
  • Page 225 225
  • Page 226 226

ARTROMOT K1 Operating Instructions Manual

Type
Operating Instructions Manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI

in other languages