ZALMAN ZM500-ST User manual

Type
User manual

This manual is also suitable for

Users Manual
ZM500-ST / ZM600-ST
Ver. 1.1
www.ZALMAN.com
To ensure safe and easy installation,
please read the following precautions.
11
1. Warnings and Safety Precautions
2. Components
Opening the cover of the product while the power cord is plugged into an outlet
may cause electrocution or critical damage to the product.
Handling the power cord with wet hands may cause electrocution.
Insertingngersormetallicobjectsintothecoolingfanmaycauseinjuryor
electrocution.
Operating the product in an extremely cold or hot environment can degrade
product performance and lifespan.
Exposure to liquids may cause malfunction.
Operation in a humid or non-ventilated environment may reduce product lifespan.
PluggingthemainpowerconnectorP1intothemotherboardwhiletheproductis
connectedtotheACpowersourcemaycausedamagetothemotherboard.
Make sure that the connectors are connected to their designated locations, and
that the connectors are not oriented in the wrong direction when connecting the
DC output connectors.
Pleaseuseglovestopreventinjuriesduringinstallation.
Productdesignsandspecicationsmayberevisedwithoutpriornoticationto
improve quality and performance.
Neglectingthefollowingmaycauseseriousinjuryordeath.
Neglectingthefollowingmaycauseminorinjuries,degradeproduct
conditions or cause malfunction.
Caution
Warning
Power Supply
AC Power Cable
Five (5) Cable Ties
Four (4) Fixing Bolts
User’s Manual
Disclaimer)ZalmanTechCo.,Ltd.isnotresponsibleforanydamagesdue
toexternal causes,including butnot limited to,improper use,
problemswith electrical power, accident, neglect, alteration,
repair, improper installation, or improper testing.
22
3. Specications
1)Electrical&PhysicalSpecications
2)OutputPowerCableSpecications
ZM500-ST ZM600-ST DC OUTPUT
AC Input Range
Voltage 100~240VAC 115~240VAC ZM500-ST
Frequency 47~63 Hz
Vout
Output Load Rating
Combined
Power
AC Input Currnet
(Rated)
115VAC 10A I
min
I
max
I
peak
230VAC 5A +3.3V 0.1A 24A
130W
500W
PFC Type Active PFC +5V 0.2A 20A
Power Factor MAX 99% +12V1 0.1A 20A
360W
Inrush Current Limit
(@ Cold start at 25
)
115VAC 50A +12V2 0.5A 20A
230VAC 100A -12V 0.0A 0.3A
Efciency MAX 86% @ 230VAC, Typical load +5VSB 0.0A 2.5A 3.5A
DC Output Voltage
Regulation
Vout Specications
At Full
Load
ZM600-ST
+3.3VDC ±5% +3.14~+3.47V
Vout
Output Load Rating
Combined
Power
+5VDC ±5% +4.75~+5.25V I
min
I
max
I
peak
+12V1DC ±5% +11.4~+12.6V +3.3V 0.1A 24A
140W
600W
+12V2DC ±5% +11.4~+12.6V +5V 0.2A 24A
-12VDC ±10% -10.8~-13.0V +12V1 0.1A 30A
500W
+5VSB ±5% +4.75~-5.25V +12V2 0.5A 30A
DC Output Ripple
&
Noise
Vout Specications
At Full
Load
-12V 0.0A 0.3A
+3.3VDC 50mV +5VSB 0.0A 2.5A 3.5A
+5VDC 50mV AmbientTemperature
+12V1DC 120mV Operation 0 ~ +40
+12V2DC 120mV Stored -20 ~ +80
-12VDC 120mV AmbientHumidity
+5VSB 50mV Operation 5 ~ 95% RH
Safety Features
Over-Voltage Protection & Over-Current Protection Stored 5 ~ 95% RH
Under-Voltage Protection
Dimensions
Short-Circuit Protection ZM500-ST / ZM600-ST
Over-Temperature Protection 140(L) x 150(W) x 86(H) mm
MainboardPower
Connector
CPU Power
Connector
S-ATA Power
Connector
S-ATA Power
Connector
ODD/HDD Power
Connector
ODD/HDD Power
Connector
ODD/HDD Power
Connector
PCI Express2
Power Connector
PCI Express1
Power Connector
ODD/HDD Power
Connector
ODD/HDD Power
Connector
ODD/HDD Power
Connector
FDD Power
Connector
33
4. Certications
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

ZALMAN ZM500-ST User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI