Sub-Zero BW30OLH Installation guide

Type
Installation guide

This manual is also suitable for

BUILT-IN EXTENDED HEIGHT GRILLE
INSTALLATION GUIDE
SPECIFICATIONS, INSTALLATION, AND MORE
EXTENDED HEIGHT GRILLE
Contents
3 Built-In Extended Height Grille
4 Air Flow Requirements
5 Functional Panel
6 Grille Hinging System
Features and specications are subject to change at any
time without notice. Visit subzero.com/specs for the most
up-to-date information.
Important Note
To ensure this product is installed and operated as safely
and efciently as possible, take note of the following types
of highlighted information throughout this guide:
IMPORTANT NOTE highlights information that is especially
important.
CAUTION indicates a situation where minor injury or product
damage may occur if instructions are not followed.
WARNING states a hazard that may cause serious injury or
death if precautions are not followed.
IMPORTANT NOTE: Throughout this guide, dimensions in
parentheses are millimeters unless otherwise specied.
2
|
Sub-Zero Customer Care 800.222.7820
subzero.com
|
3
Built-In Extended Height Grille
WARNING
This design feature involves potentially hazardous ele-
ments consisting of large, heavy panels located over-
head. It is the responsibility of the designer to specify
panel support components suitable for this use and the
installer to use proper workmanship during construc-
tion. Sub-Zero cannot be liable for custom applications
beyond its control.
FLUSH INSET
All built-in ush inset models have the option of extending
the height of the decorative grille panel. This application is
used when the kitchen design calls for a decorative panel
taller than the standard grille for an 84"
(2134) nished height
or the optional grille for an 88"
(2235) nished height. With an
extended height grille panel, the nished height of the unit
can be 88"
(2235) or more to match surrounding cabinetry.
The decorative grille panel and support hinges are provided
by the customer. The factory-supplied grille frame is tted
with a functional panel that serves as an air bafe. The grille
frame also acts as a support to hold the decorative panel
open for condenser cleaning, water lter replacement, and
service.
The decorative panel and grille frame are supported by two
separate hinge systems and are only connected by a cleat
when open and a catch when closed.
EXTENDED HEIGHT GRILLE
FLUSH INSET PANELS
The ush inset design allows for custom grille and door
panels to be completely ush, blending more seamlessly
with surrounding cabinetry.
Flush inset panels.
4
|
Sub-Zero Customer Care 800.222.7820
EXTENDED HEIGHT GRILLE
Space must be maintained between the decorative grille
panel and surrounding cabinetry for air ow. Refer to the
illustrations below.
IMPORTANT NOTE: If space is not provided directly above
the top of the grille panel, it must be provided above the
upper molding of the elevation as shown in the illustration
below.
Air Flow Requirements
Allow for at least
1
/2" (13) space on all four sides of the grille
panel for proper air ow to the refrigeration system. For
ush inset models, this is around the sides, top and bottom
of the decorative grille panel. Refer to the illustration below.
CABINETRY
CABINETRY
Air ow above grille panel.
Air ow above molding.
1
/2" (13) MIN SPACE
ALL SIDES
DECORATIVE
GRILLE PANEL
Air ow.
subzero.com
|
5
EXTENDED HEIGHT GRILLE
Functional Panel
A
1
/4" (6) thick functional panel must be installed in the inner
grille frame (the part that ips up) to prevent warm air dis-
charge from short-circuiting back into the system. Refer to
the illustration below.
Use sizing for the “backer panel” found in the panel
congurator or Sub-Zero design guide. Visit our website,
subzero.com.
FUNCTIONAL
PANEL
Functional panel (side view).
6
|
Sub-Zero Customer Care 800.222.7820
EXTENDED HEIGHT GRILLE
Grille Hinging System
HINGING SYSTEM
Specify the customer-supplied hinging system consistent
with cabinetry and with sufcient capacity to support the
weight of the decorative grille panel. Refer to the illustration
below.
IMPORTANT NOTE: If refrigeration components must be
removed for service, the standard grille frame will need to be
removed rst for sufcient access to the machine compart-
ment. To avoid an unsupported load, the decorative panel
will need to be removed from the cabinetry rst.
CLEAT
Field install a cleat to the back side of the decorative grille
panel to hold the ip-up inner grille frame in position when
raised. Follow dimensions in the inset illustration below for
the 10"
(254) long cleat. For location of the cleat, also refer to
the illustration on the following page. For a dual installation,
use two cleats.
CAUTION
The cleat must include a lip as shown, to prevent unin-
tentional separation of the decorative panel and grill
frame.
HINGING FOR
DECORATIVE
GRILLE PANEL
STANDARD GRILLE
FRAME IN CLOSED
POSITION
HINGING FOR
DECORATIVE
GRILLE PANEL
STANDARD GRILLE
FRAME IN FULLY
RAISED POSITION
GRILLE CLEARANCE
REQUIRED FOR SERVICE
CLEAT
CLEAT END VIEW
1
/2" (13)
2" (51)
1
1
/2"
(38)
1
/
2
"
(13) LIP
2" (51)
1
1
/
2
"
(38)
Grille hinging system (side view).
Depending on the design and size of the catch, it will need
to be recessed into the functional grille panel and possibly
partially into the decorative grille panel.
subzero.com
|
7
EXTENDED HEIGHT GRILLE
Grille Hinging System
INSTALL CLEAT AND CATCH
The cleat must be located to the left of a line 3" (76) to the
right of the center of the built-in unit to clear the system fan
shroud. Refer to the illustration below.
Cut a rectangular clearance hole in the functional grille panel
to allow the cleat to extend through when the decorative
grille panel is closed.
Install a customer-supplied catch between the back of the
decorative grille panel and the functional grille panel to pre-
vent noise caused by vibration.
Sub-Zero, Sub-Zero & Design, Sub-Zero & Snowake Design, Dual Refrigeration, The Living Kitchen, Great American Kitchens The Fine Art of Kitchen Design, Wolf, Wolf &
Design, Wolf Gourmet, W & Design, red colored knobs, Cove, and Cove & Design are registered trademarks and service marks of Sub-Zero Group, Inc. and its subsidiaries.
All other trademarks are property of their respective owners in the United States and other countries.
C
L
FUNCTIONAL GRILLE PANEL
CATCH
CLEARANCE HOLE
CLEAT
2
1
/2" (64) MIN
2
1
/2" (64) MIN
3" (76)
DECORATIVE GRILLE PANEL
Install cleat and catch.
CATCH
Catch (side view).
SUB-ZERO, INC. P.O. BOX 44848 MADISON, WI 53744 SUBZERO.COM 800.222.7820
0000000 REV-A 5/2018
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Sub-Zero BW30OLH Installation guide

Type
Installation guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI