Installation & Maintenance Manual
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result in serious injury,
death, or property damage.
—Donotstoreorusegasolineorotherammablevaporsand
liquidsinthevicinityofthisoranyotherappliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phoneinyourbuilding.
• Leavethebuildingimmediately.
• Immediatelycallyourgassupplierfromaneighbour's
phone. Follow the gas supplier’s instructions.
• Ifyoucannotreachyourgassupplier,callthere
department.
—Installationandservicemustbeperformedbyaqualied
installer,serviceagencyorthegastter.
BVK35 Kit
DIRECT VENT ADAPTER TO 5” B-VENT
Applicable for:
Installation and service must be performed by a qualied installer,
service agency or the gas tter. Check local codes and read all
instructions prior to installation.
Some materials used in the manufacturing process of this product can
expose you to Benzene which is known in the State of California to
cause cancer and birth defects or other reproductive harm. For more
information go to www.P65warnings.ca.gov
WARNING
Installer: Leave this manual with the appliance. Please refer to the
Montigo website for the most current version of the replace manual
Consumer: Retain this manual for future reference. Please refer to the
Montigo website for the most current version of the replace manual
NOTICE
DRL3613NI / DRL3613NI-2
DRL4813NI / DRL4813NI-2
DRL6013NI / DRL6013NI-2
DRSQ34NI / DRSQ34NI-2
DRSQ38NI / DRSQ38NI-2
Listed direct vent appliances can be installed on existing 5" Certied
B-Vent system by using BVK35 kit and inserting a 3" aluminum ex liner
within the B-vent and utilizing the space between the ex and B-Vent
for combustion air.
The BVK35 kit and listed replace models could also be connected to
existing 6" Certied B-Vent system by using Certied 5" to 6" B-Vent
increaser (not provided with the BVK35 kit).
The BVK35 kit is approved for use with following NG models only: DRL36,
DRL48, DRL60, DRSQ34, DRSQ38. LP CONVERSION IS NOT ALLOWED
WHEN RETROFITTING INTO EXISTING B-VENT.
The dimensions of the appliance and the clearances to combustibles
are listed in the installation manuals packaged with the appliance.
Venting must terminate through the roof, no side venting allowable.
4"x7" coaxial vent rigid or ex pipe can be used to extend from top of
replace to Lower B-Vent adapter attached to existing B-Vent. If 4"x
7" ex pipe is used then existing B-Vent must be properly strapped to
support its weight.
INSTALLERS RESPONSIBILITIES BEFORE AND AFTER CONVERSION
TO DIRECT VENT COMPLETED:
• Inspect existing B-Vent conguration allows installation of 3" ex
liner without damage to the existing vent system.
• Inspect existing B-Vent is damage free and adequately supported.
• Conrm existing B-Vent has minimum l" clearance to combustible
materials through all vent length.
• Conrm existing venting dual wall pipe, not single wall pipe.
• Direct vent replace is installed as prescribed in the installation
manual packaged with the replace