Features
The Wire Wizard HHSS is a battery operated, handheld,
microprocessor-controlled contact type tachometer. It
incorporates the latest micro-circuit technology and offers:
Multi-mode capability measures RPM, FPM, YPM, mPM
and other units without special accessories
Large memory capacity
Wide speed range with automatic floating decimal point
C-MOS single chip microprocessor for high reliability and
low maintenance
Rugged construction - die-cast aluminum housing
NOTE: When using master wheel, accuracy can be affected
as much as 0.3% of reading
CAUTION: Although tachometer alone is able to achieve
above ranges, the master wheel has a maximum speed limitation
of 5,000 FPM (for safety reasons).
HHSSLEDOM
Display Range 0.10 to 25,000 rpm with floating decimal
Accuracy ±0.06 rpm: 0.10 to 999.99 rpm
± 0.6 rpm: 1,000.0 to 9,999.9 rpm
±0.006% of reading ±1 digit (or ±2rpm max.): 10,000 to 25,000 rpm
Display 5 digit 0.47" (12mm) high LCD
Measuring Units Revolutions: RPH, RPM Feet: FPH, FPM Miles: MPH
Yards: YPH, YPM Inches: IPM Meters: mPH, mPM
Length: m, cm, inches, feet, yards Total revolutions: REV
Memory System 13 readings are stored in memory and retained for
5 minutes (last, max., min. and 10 extra measurements)
Detection Optical coupler , 60 pulses/rev
System Control Single chip C-MOS microprocessor
Over Range Indicator Flashing numerals
Update Time 1 second (typical)
Batteries Included Size: 2 AA 1.5V
Life: Approx. 65 hrs
Low Voltage Indicator Flashing “LO BAT” display
Operating Temperature 32° to 113°F (0° to 45°C)
Construction Die-cast aluminum housing
Weight 0.9 lbs (400g)
Dimensions 7.3"L x 2.4"W x 1.8"H (185mm x 60mm x 45.7mm)
Warranty 1 year
STANDARD ACCESSORIES 2 cone adapters, 1 funnel adapter, 3-1/2" extension shaft,
carrying case and 1 master wheel (6" cir.)
Using the master wheel and proper mode selector switch,
the following industrial units of measurement are achieved.
Range and Accuracy
Specifications
HHSSLEDOM
R: REVOLUTIONS SINGLE RANGE ACCURACY RESOLUTION
Contact RPM (rev./min.) 0.10 - 999.99 ± 0.06 0.01
1,000.0 - 9,999.9 ± 0.6 0.1
10,000 - 25,000 ±0.006% of reading ±1digit 1
(or ±2 rpm max.)
Contact RPH (rev./hour) 6 - 99,999 ±0.006% of reading ±1digit 1
(or ±6 rpm max.)
REV (total revolution) 0.1 - 9,999.9 ± 0.1 0.1
10,000 - 99,999 ± 1 1
F: FEET SINGLE RANGE ACCURACY RESOLUTION
F/M (feet/min) 0.05 - 999.99 ± 0.06 0.01
1,000.0 - 9,999.9 ± 0.6 0.1
10,000 - 12,500 ± 1 1
F/H (feet/hour) 3 - 99,999 ±0.006% of reading ±1digit 1
(or ±6 FPH max.)
FT (length) 10.099.999 - 10.0
1.09.999,9 - 0.000,1
1999,99 - 000,01
Y: YARDS SINGLE RANGE ACCURACY RESOLUTION
Y/M (yards/min.) 0.02 - 999.99 ± 0.06 0.01
1,000.0 - 4,167.0 ± 0.3 0.1
Y/H (yards/hour) 1.0 - 9,999.9 ±0.6 0.1
10,000 - 99,999 ±0.006% of reading ±1digit 1
(or ±6 YPH max.)
YRd (length) 500.0599.99 - 500.0
10.099.999 - 00.001
1.09.999,9 - 0.000,1
1999,99 - 000,01
I: INCHES SINGLE RANGE ACCURACY RESOLUTION
I/M (inches/min.) 0.6 - 9,999.9 ±0.6 0.1
10,000 - 99,999 ±0.006% of reading ±1digit 1
(or ±6 IPM max.)
IN (length) 1.09.999,9 - 1.0
1999,99 - 000,01
m: METERS SINGLE RANGE ACCURACY RESOLUTION
m/M (meters/min.) 0.02 - 999.99 ± 0.06 0.01
1,000.0 - 3,810.0 ± 0.3 0.1
m/H (meters/hour) 0.9 - 9,999.9 ± 0.6 0.1
10,000 - 99,999 ±0.006% of reading ±1digit 1
(or ±6 mPH max.)
m (length) 500.0599.99 - 500.0
10.099.999 - 00.001
1.09.999,9 - 0.000,1
1999,99 - 000,01
cm (length) 5.05.999,9 - 5.0
1999,99 - 000,01
M: MILES SINGLE RANGE ACCURACY RESOLUTION
M/H (miles/hour) 0.0006 - 9.9999 ± 0.0006 0.0001
10.000 - 99.999 ± 0.006 0.001
100.00 - 142.05 ± 0.01 0.01
Top View
Wire Feed >
Tension Knob >
Memory Recall
A. AUTOMATIC MEMORY
The following are automatically stored in memory for 5 minutes
following release of the power switch:
Last reading
Maximum reading
Minimum reading
These readings will be displayed in the following order when
the memory switch is pressed:
Last reading
Maximum reading
Minimum reading
To fill all three memory spaces, unit must operate for about 5
seconds. If any of the above memory readings are missing,
unit must operate a few seconds longer.
B. MEMORY SELECTION
The HHSS has the capability of storing 10 extra readings in
its memory. These readings can be obtained from the same
machine or many machines (up to 10) by pressing the memory
switch momentarily as the reading you wish stored appears on
the display. An "M" with an integer will appear on the top of
the display momentarily, and will be stored in memory. Up to
10 readings can be stored.
NOTE: All memory data will be erased if automatic shut-off
has occurred. To recall a specific reading, press the memory
switch until the desired reading shows up on the display along
with its memory position. To erase all data from the memory,
press the memory switch for at least 5 seconds until display
shows CCCCC. If you hold the memory switch, the display
will continue to show CCCCC until the switch is released, then
will default to 0.00.
Battery Replacement
Low battery voltage is
indicated by LO BAT on
the display. Remove end
cover by using a coin or
appropriate screwdriver
and replace both batteries.
Please note polarity.
Operating Procedure
1. Run wire through the two
wheels at the top of the
unit (as shown).
The HHSS may be attached to
a male disconnect on the side
with the pull pin.
3. Begin feeding wire through the unit. Ensure the wheels
are turning as the wire is moving. If there is slippage,
tighten the front tension knob to increase tension.
4. Press and hold the on-of f switch.
Display will update approximately
every second.
5. Observe speed for as long as it is desired.
6. On-off switch must be released prior to removal of tachometer
from rotating object if last reading must be captured.
7. After release of power switch, the last reading will be displayed
for approximately 5 minutes. Readings will be retained in
memory for 5 minutes and can be extended any number of
additional 5 minute periods by re-pressing the memory switch.
Surface Speed Metric Conversion
Conversions such as YPM to mPM or mPM to YPM may be
obtained from the memory only by switching from one mode
to another.
2. Turn selector switch to desired unit.
Top View
On/Off Switch
Wire Feed >
Pin for
male QD
attachment
Tension Knob >
On/Off
ELCo Enterpises, Inc. • 5750 Marathon Drive • Jackson, MI USA 49201 • (517) 782-8040 • Fax (517) 782-8039
www.wire-wizard.com
  • Page 1 1
  • Page 2 2

Wire wizard HHSS User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI