Genie GCL-T is a heavy-duty, trolley-style garage door opener designed for commercial applications. It boasts a powerful 1/2 HP motor capable of lifting doors weighing up to 600 lbs. It features adjustable speed and force settings, allowing for precise control over the door's movement. The GCL-T includes a wireless keypad and two pre-programmed remotes for easy access. It also has a built-in obstruction detection system to ensure safe operation.

Genie GCL-T is a heavy-duty, trolley-style garage door opener designed for commercial applications. It boasts a powerful 1/2 HP motor capable of lifting doors weighing up to 600 lbs. It features adjustable speed and force settings, allowing for precise control over the door's movement. The GCL-T includes a wireless keypad and two pre-programmed remotes for easy access. It also has a built-in obstruction detection system to ensure safe operation.

www.GenieCompany.com/commercial | 800.843.4084
Wiring Diagram
GCL-GT
HEAVY-DUTY GEAR HEAD TROLLEY OPERATOR
©2012 The Genie Company
Single PhaSe Wiring Diagram
36423 ORIGINAL ISSUE
A 36496 CHANGED MOTOR VOLTAGES
RJS 9-5-08
B 36497 REMOVED OPTIONAL TRANSFORMER
RJS 10-23-08
X
8 PT C1S TAG MATERIAL WITH PERMANENT
ADHESIVE. UV GLAZEKOTE FINISH. SLIT BACK.
LABELS SUPPLIED FLAT.
VERTICAL SLIT 1.25” FROM LEFT EDGE
BLACK ON WHITE
RJS
4/07/08
DECAL, WIRING
DIAGRAM, 1 PHASE
15.25 X 7.0
1 OF 1
NTS
B
111209.0001
.25 TYPICAL
EXTRA
BACKING
15.25" +/- .060"
LABEL SIZE
7.00" +/- .060"
LABEL SIZE
1-BTN
STATION
KEY
SWITCH
STATION
CARD
READER
O/C
PULL
SWITCH
N/O
N/O
N/O
N/O
REMOVE
JUMPER
WHEN
INSTALLING
EXTERNAL
INTERLOCK
+24
VDC
STB
ENAB
TROUBLESHOOTING LED’s
EXTERNAL WIRING DIAGRAM
+ 24 VOLTS
DC
STB
ENABLE
ON
=
STB ENABLED
OFF
=
STB DISABLED
ON
=
POWER AVAILABLE
OFF
=
CHECK AC POWER
SUPPLY. CHECK FUSES
GDB - 2.5A OR
S500 - 2.5A
EXTERNAL
RADIO
CONNECTOR
INTERNAL
RADIO BOARD
BRAKE
CONNECTOR
CIRCUIT BREAKER
(CERTAIN MODELS ONLY)
TRANSFORMER
CONNECTORS
SECONDARY FUSE
RADIO FUSE
EXTERNAL ANTENNA
CONNECTION
INPUT POWER
TERMINALS
HOIST
INTERLOCK
CONNECTOR
EXPANSION
BOARD PORT
TROUBLE-
SHOOTING
LEDs
EXPANSION
MODULE
MOUNTING
LOCATIONS
LIMIT SENSOR
CONNECTOR
LINE
GROUND
TRANSFORMER
CONTROL WIRE
TERMINALS
ROUTE HIGH
VOLTAGE WIRES
THROUGH THIS
SHADED AREA
ROUTE LOW
VOLTAGE WIRES
THROUGH THIS
SHADED AREA
(PLUG UNUSED HOLES)
(PLUG UNUSED HOLES)
MOTOR
CONNECTORS
GDB - 250 mA OR
S504 - 250 mA
(CLASS 2 CONNECTIONS)
(COAX)
LINE IN
POWER CONNECTIONS
MULTIPLE
3-BUTTON
STATION
INSTALLATIONS
REQUIRE THE
STOP BUTTON
TO BE WIRED
IN SERIES.
See Fig. 5, pg 5.4
*
L1/ L1
N/ L2
GND
LINE
(HOT)
NEUTRAL
LINE 1
LINE 2
115V
208/230V
EXT
INTLK
EXT
INTLK
N-O
REVERSE
N-O
REVERSE
ODC
STB
ODC
STB
1-BTNGNDSTOPCLOSEOPEN
EXT RADIO CONNECTOR
SENSING EDGE SWITCH
(DO NOT CONNECT
2-WIRE MONITORED
SENSING EDGE SWITCH
TO THESE INPUTS)
PWR
RAD
GND
GND
THRU-BEAM
PHOTOCELLS
+
-
+
-
PWR
20-40 VDC @ 250mA
MAX CURRENT
RELAY
GND
NOM
+ 24VDC
RADIO
SERIES II SAFE-T-BEAM
®
(STB)
(
*
CONNECT STB WIRES
TO EITHER TERMINAL)
*
OPEN
CLOSE
STOP
REMOVE
JUMPER
IF STOP
BUTTON
IS USED
3-BUTTON
STATION
*
NOT FOR RESIDENTIAL USE
WARNING: FOR CONTINUED PROTECTION AGAINST FIRE, REPLACE FUSES ONLY WITH THE SAME TYPE AND RATING
P/N 111209.0001
208/230V 1PH 115V 1PH
NOTE: CIRCLED DIMENSIONS DESIGNATE CTQ,
(CRITICAL TO QUALITY) SPECIFICATIONS
RCA
9/8/08
RCA 10/24/08
www.GenieCompany.com/commercial | 800.843.4084
Wiring Diagram
GCL-GT
HEAVY-DUTY GEAR HEAD TROLLEY OPERATOR
©2012 The Genie Company
Single PhaSe Wiring Diagram
36423 ORIGINAL ISSUE
A 36496 CHANGED MOTOR VOLTAGES
RJS 9-5-08
B 36497 REMOVED OPTIONAL TRANSFORMER
RJS 10-23-08
X
8 PT C1S TAG MATERIAL WITH PERMANENT
ADHESIVE. UV GLAZEKOTE FINISH. SLIT BACK.
LABELS SUPPLIED FLAT.
VERTICAL SLIT 1.25” FROM LEFT EDGE
BLACK ON WHITE
RJS
4/07/08
DECAL, WIRING
DIAGRAM, 1 PHASE
15.25 X 7.0
1 OF 1
NTS
B
111209.0001
.25 TYPICAL
EXTRA
BACKING
15.25" +/- .060"
LABEL SIZE
7.00" +/- .060"
LABEL SIZE
1-BTN
STATION
KEY
SWITCH
STATION
CARD
READER
O/C
PULL
SWITCH
N/O
N/O
N/O
N/O
REMOVE
JUMPER
WHEN
INSTALLING
EXTERNAL
INTERLOCK
+24
VDC
STB
ENAB
TROUBLESHOOTING LED’s
EXTERNAL WIRING DIAGRAM
+ 24 VOLTS
DC
STB
ENABLE
ON
=
STB ENABLED
OFF
=
STB DISABLED
ON
=
POWER AVAILABLE
OFF
=
CHECK AC POWER
SUPPLY. CHECK FUSES
GDB - 2.5A OR
S500 - 2.5A
EXTERNAL
RADIO
CONNECTOR
INTERNAL
RADIO BOARD
BRAKE
CONNECTOR
CIRCUIT BREAKER
(CERTAIN MODELS ONLY)
TRANSFORMER
CONNECTORS
SECONDARY FUSE
RADIO FUSE
EXTERNAL ANTENNA
CONNECTION
INPUT POWER
TERMINALS
HOIST
INTERLOCK
CONNECTOR
EXPANSION
BOARD PORT
TROUBLE-
SHOOTING
LEDs
EXPANSION
MODULE
MOUNTING
LOCATIONS
LIMIT SENSOR
CONNECTOR
LINE
GROUND
TRANSFORMER
CONTROL WIRE
TERMINALS
ROUTE HIGH
VOLTAGE WIRES
THROUGH THIS
SHADED AREA
ROUTE LOW
VOLTAGE WIRES
THROUGH THIS
SHADED AREA
(PLUG UNUSED HOLES)
(PLUG UNUSED HOLES)
MOTOR
CONNECTORS
GDB - 250 mA OR
S504 - 250 mA
(CLASS 2 CONNECTIONS)
(COAX)
LINE IN
POWER CONNECTIONS
MULTIPLE
3-BUTTON
STATION
INSTALLATIONS
REQUIRE THE
STOP BUTTON
TO BE WIRED
IN SERIES.
See Fig. 5, pg 5.4
*
L1/ L1
N/ L2
GND
LINE
(HOT)
NEUTRAL
LINE 1
LINE 2
115V
208/230V
EXT
INTLK
EXT
INTLK
N-O
REVERSE
N-O
REVERSE
ODC
STB
ODC
STB
1-BTNGNDSTOPCLOSEOPEN
EXT RADIO CONNECTOR
SENSING EDGE SWITCH
(DO NOT CONNECT
2-WIRE MONITORED
SENSING EDGE SWITCH
TO THESE INPUTS)
PWR
RAD
GND
GND
THRU-BEAM
PHOTOCELLS
+
-
+
-
PWR
20-40 VDC @ 250mA
MAX CURRENT
RELAY
GND
NOM
+ 24VDC
RADIO
SERIES II SAFE-T-BEAM
®
(STB)
(
*
CONNECT STB WIRES
TO EITHER TERMINAL)
*
OPEN
CLOSE
STOP
REMOVE
JUMPER
IF STOP
BUTTON
IS USED
3-BUTTON
STATION
*
NOT FOR RESIDENTIAL USE
WARNING: FOR CONTINUED PROTECTION AGAINST FIRE, REPLACE FUSES ONLY WITH THE SAME TYPE AND RATING
P/N 111209.0001
208/230V 1PH 115V 1PH
NOTE: CIRCLED DIMENSIONS DESIGNATE CTQ,
(CRITICAL TO QUALITY) SPECIFICATIONS
RCA
9/8/08
RCA 10/24/08
www.GenieCompany.com/commercial | 800.843.4084
Wiring Diagram
GCL-GT
HEAVY-DUTY GEAR HEAD TROLLEY OPERATOR
©2012 The Genie Company
Three PhaSe Wiring Diagram
36423 ORIGINAL ISSUE
A 36496 CHANGED MOTOR VOLTAGES
RJS 9-5-08
X
8 PT C1S TAG MATERIAL WITH PERMANENT
ADHESIVE. UV GLAZEKOTE FINISH. SLIT BACK.
LABELS SUPPLIED FLAT.
VERTICAL SLIT 1.25” FROM LEFT EDGE
BLACK ON WHITE
RJS
DECAL, WIRING
DIAGRAM, 3 PHASE
15.25 X 7.0
1 OF 1
NTS
B
111281.0001
15.25" +/- .060"
LABEL SIZE
7.00" +/- .060"
LABEL SIZE
.25 TYPICAL
EXTRA
BACKING
+24
VDC
STB
ENAB
TROUBLESHOOTING LED’s
+ 24 VOLTS
DC
STB
ENABLE
ON
=
STB ENABLED
OFF
=
STB DISABLED
ON
=
POWER AVAILABLE
OFF
=
CHECK AC POWER
SUPPLY. CHECK FUSES
GDB - 2.5A or
S500 - 2.5A
EXTERNAL
RADIO
CONNECTOR
BRAKE
CONNECTOR
SECONDARY FUSE
RADIO FUSE
EXTERNAL ANTENNA
CONNECTION
HOIST
INTERLOCK
CONNECTOR
EXPANSION
BOARD PORT
LIMIT SENSOR
CONNECTOR
LINE
GROUND
TRANSFORMER
CONTROL WIRE
TERMINALS
ROUTE HIGH
VOLTAGE WIRES
THROUGH THIS
SHADED AREA
ROUTE LOW
VOLTAGE WIRES
THROUGH THIS
SHADED AREA
MOTOR
CONNECTORS
208/230V 3PH 460V 3PH
GDB - 250 mA OR
S504 - 250 mA
(COAX)
TRANSFORMER
CONNECTORS
INPUT POWER
TERMINALS
INTERNAL
RADIO BOARD
LINE IN
POWER CONNECTIONS
L1
L2
GND
LINE 1
LINE 2 LINE 3
L3
(PLUG UNUSED HOLES)
(
PLUG UNUSED HOLES)
NOT FOR RESIDENTIAL USE
1-BTN
STATION
KEY
SWITCH
STATION
CARD
READER
O/C
PULL
SWITCH
N/O
N/O
N/O
N/O
REMOVE
JUMPER
WHEN
INSTALLING
EXTERNAL
INTERLOCK
EXTERNAL WIRING DIAGRAM
MULTIPLE
3-BUTTON
STATION
INSTALLATIONS
REQUIRE THE
STOP BUTTON
TO BE WIRED
IN SERIES.
See Fig. 5, pg 5.4
*
EXT
INTLK
EXT
INTLK
N-O
REVERSE
N-O
REVERSE
ODC
STB
ODC
STB
1-BTNGNDSTOPCLOSEOPEN
EXT RADIO CONNECTOR
SENSING EDGE SWITCH
(DO NOT CONNECT
2-WIRE MONITORED
SENSING EDGE SWITCH
TO THESE INPUTS)
PWR
RAD
GND
GND
THRU-BEAM
PHOTOCELLS
+
-
+
-
PWR
20-40 VDC @ 250mA
MAX CURRENT
RELAY
GND
NOM
+ 24VDC
RADIO
SERIES II SAFE-T-BEAM
®
(STB)
(
*
CONNECT STB WIRES
TO EITHER TERMINAL)
*
OPEN
CLOSE
STOP
REMOVE
JUMPER
IF STOP
BUTTON
IS USED
3-BUTTON
STATION
*
WARNING: FOR CONTINUED PROTECTION AGAINST FIRE, REPLACE FUSES ONLY WITH THE SAME TYPE AND RATING
P/N 111281.0001
EXPANSION
MODULE
MOUNTING
LOCATIONS
TROUBLE-
SHOOTING
LEDs
NOTE: CIRCLED DIMENSIONS DESIGNATE CTQ,
(CRITICAL TO QUALITY) SPECIFICATIONS
L1 L2 L3
208/230—460V
RCA
B 36497 REMOVED OPTIONAL TRANSFORMER
RJS 10-23-08
4/07/08
9/8/08
RCA 10/24/08
www.GenieCompany.com/commercial | 800.843.4084
Wiring Diagram
GCL-GT
HEAVY-DUTY GEAR HEAD TROLLEY OPERATOR
©2012 The Genie Company
Three PhaSe Wiring Diagram
36423 ORIGINAL ISSUE
A 36496 CHANGED MOTOR VOLTAGES
RJS 9-5-08
X
8 PT C1S TAG MATERIAL WITH PERMANENT
ADHESIVE. UV GLAZEKOTE FINISH. SLIT BACK.
LABELS SUPPLIED FLAT.
VERTICAL SLIT 1.25” FROM LEFT EDGE
BLACK ON WHITE
RJS
DECAL, WIRING
DIAGRAM, 3 PHASE
15.25 X 7.0
1 OF 1
NTS
B
111281.0001
15.25" +/- .060"
LABEL SIZE
7.00" +/- .060"
LABEL SIZE
.25 TYPICAL
EXTRA
BACKING
+24
VDC
STB
ENAB
TROUBLESHOOTING LED’s
+ 24 VOLTS
DC
STB
ENABLE
ON
=
STB ENABLED
OFF
=
STB DISABLED
ON
=
POWER AVAILABLE
OFF
=
CHECK AC POWER
SUPPLY. CHECK FUSES
GDB - 2.5A or
S500 - 2.5A
EXTERNAL
RADIO
CONNECTOR
BRAKE
CONNECTOR
SECONDARY FUSE
RADIO FUSE
EXTERNAL ANTENNA
CONNECTION
HOIST
INTERLOCK
CONNECTOR
EXPANSION
BOARD PORT
LIMIT SENSOR
CONNECTOR
LINE
GROUND
TRANSFORMER
CONTROL WIRE
TERMINALS
ROUTE HIGH
VOLTAGE WIRES
THROUGH THIS
SHADED AREA
ROUTE LOW
VOLTAGE WIRES
THROUGH THIS
SHADED AREA
MOTOR
CONNECTORS
208/230V 3PH 460V 3PH
GDB - 250 mA OR
S504 - 250 mA
(COAX)
TRANSFORMER
CONNECTORS
INPUT POWER
TERMINALS
INTERNAL
RADIO BOARD
LINE IN
POWER CONNECTIONS
L1
L2
GND
LINE 1
LINE 2 LINE 3
L3
(PLUG UNUSED HOLES)
(
PLUG UNUSED HOLES)
NOT FOR RESIDENTIAL USE
1-BTN
STATION
KEY
SWITCH
STATION
CARD
READER
O/C
PULL
SWITCH
N/O
N/O
N/O
N/O
REMOVE
JUMPER
WHEN
INSTALLING
EXTERNAL
INTERLOCK
EXTERNAL WIRING DIAGRAM
MULTIPLE
3-BUTTON
STATION
INSTALLATIONS
REQUIRE THE
STOP BUTTON
TO BE WIRED
IN SERIES.
See Fig. 5, pg 5.4
*
EXT
INTLK
EXT
INTLK
N-O
REVERSE
N-O
REVERSE
ODC
STB
ODC
STB
1-BTNGNDSTOPCLOSEOPEN
EXT RADIO CONNECTOR
SENSING EDGE SWITCH
(DO NOT CONNECT
2-WIRE MONITORED
SENSING EDGE SWITCH
TO THESE INPUTS)
PWR
RAD
GND
GND
THRU-BEAM
PHOTOCELLS
+
-
+
-
PWR
20-40 VDC @ 250mA
MAX CURRENT
RELAY
GND
NOM
+ 24VDC
RADIO
SERIES II SAFE-T-BEAM
®
(STB)
(
*
CONNECT STB WIRES
TO EITHER TERMINAL)
*
OPEN
CLOSE
STOP
REMOVE
JUMPER
IF STOP
BUTTON
IS USED
3-BUTTON
STATION
*
WARNING: FOR CONTINUED PROTECTION AGAINST FIRE, REPLACE FUSES ONLY WITH THE SAME TYPE AND RATING
P/N 111281.0001
EXPANSION
MODULE
MOUNTING
LOCATIONS
TROUBLE-
SHOOTING
LEDs
NOTE: CIRCLED DIMENSIONS DESIGNATE CTQ,
(CRITICAL TO QUALITY) SPECIFICATIONS
L1 L2 L3
208/230—460V
RCA
B 36497 REMOVED OPTIONAL TRANSFORMER
RJS 10-23-08
4/07/08
9/8/08
RCA 10/24/08
www.GenieCompany.com/commercial | 800.843.4084
Wiring Diagram
GCL-GT
HEAVY-DUTY GEAR HEAD TROLLEY OPERATOR
©2012 The Genie Company
575 VolT PhaSe Wiring Diagram
36423 ORIGINAL ISSUE
X
8 PT C1S TAG MATERIAL WITH PERMANENT
ADHESIVE. UV GLAZEKOTE FINISH. SLIT BACK.
LABELS SUPPLIED FLAT.
VERTICAL SLIT 1.25” FROM LEFT EDGE
BLACK ON WHITE
RJS
RCA
DECAL, WIRING
DIAGRAM, 575V
15.25 X 7.0
1 OF 1
NTS
B
111379.0001
.25 TYPICAL
EXTRA
BACKING
15.25" +/- .060"
LABEL SIZE
7.00" +/- .060"
LABEL SIZE
+24
VDC
STB
ENAB
TROUBLESHOOTING LED’s
+ 24 VOLTS
DC
STB
ENABLE
ON
=
STB ENABLED
OFF
=
STB DISABLED
ON
=
POWER AVAILABLE
OFF
=
CHECK AC POWER
SUPPLY. CHECK FUSES
GDB - 2.5A or
S500 - 2.5A
EXTERNAL
RADIO
CONNECTOR
BRAKE
CONNECTOR
SECONDARY FUSE
RADIO FUSE
EXTERNAL ANTENNA
CONNECTION
HOIST
INTERLOCK
CONNECTOR
EXPANSION
BOARD PORT
LIMIT SENSOR
CONNECTOR
LINE
GROUND
TRANSFORMER
CONTROL WIRE
TERMINALS
ROUTE HIGH
VOLTAGE WIRES
THROUGH THIS
SHADED AREA
ROUTE LOW
VOLTAGE WIRES
THROUGH THIS
SHADED AREA
MOTOR
CONNECTOR
575V 3PH
GDB - 250 mA OR
S504 - 250 mA
(COAX)
TRANSFORMER
CONNECTORS
INPUT POWER
TERMINALS
INTERNAL
RADIO BOARD
LINE IN
POWER CONNECTIONS
L1
L2
GND
LINE 1
LINE 2 LINE 3
L3
(PLUG UNUSED HOLES)
(
PLUG UNUSED HOLES)
NOT FOR RESIDENTIAL USE
1-BTN
STATION
KEY
SWITCH
STATION
CARD
READER
O/C
PULL
SWITCH
N/O
N/O
N/O
N/O
REMOVE
JUMPER
WHEN
INSTALLING
EXTERNAL
INTERLOCK
EXTERNAL WIRING DIAGRAM
MULTIPLE
3-BUTTON
STATION
INSTALLATIONS
REQUIRE THE
STOP BUTTON
TO BE WIRED
IN SERIES.
See Fig. 5, pg 5.4
*
EXT
INTLK
EXT
INTLK
N-O
REVERSE
N-O
REVERSE
ODC
STB
ODC
STB
1-BTNGNDSTOPCLOSEOPEN
EXT RADIO CONNECTOR
SENSING EDGE SWITCH
(DO NOT CONNECT
2-WIRE MONITORED
SENSING EDGE SWITCH
TO THESE INPUTS)
PWR
RAD
GND
GND
THRU-BEAM
PHOTOCELLS
+
-
+
-
PWR
20-40 VDC @ 250mA
MAX CURRENT
RELAY
GND
NOM
+ 24VDC
RADIO
SERIES II SAFE-T-BEAM
®
(STB)
(
*
CONNECT STB WIRES
TO EITHER TERMINAL)
*
OPEN
CLOSE
STOP
REMOVE
JUMPER
IF STOP
BUTTON
IS USED
3-BUTTON
STATION
*
WARNING: FOR CONTINUED PROTECTION AGAINST FIRE, REPLACE FUSES ONLY WITH THE SAME TYPE AND RATING
P/N 111379.0001
EXPANSION
MODULE
MOUNTING
LOCATIONS
TROUBLE-
SHOOTING
LEDs
L1 L2 L3
NOTE: CIRCLED DIMENSIONS DESIGNATE CTQ,
(CRITICAL TO QUALITY) SPECIFICATIONS
575V
A 36497 REMOVED OPTIONAL TRANSFORMER
RJS 10-23-08
4/07/08
9/8/08
RCA 10/24/08
www.GenieCompany.com/commercial | 800.843.4084
Wiring Diagram
GCL-GT
HEAVY-DUTY GEAR HEAD TROLLEY OPERATOR
©2012 The Genie Company
575 VolT PhaSe Wiring Diagram
36423 ORIGINAL ISSUE
X
8 PT C1S TAG MATERIAL WITH PERMANENT
ADHESIVE. UV GLAZEKOTE FINISH. SLIT BACK.
LABELS SUPPLIED FLAT.
VERTICAL SLIT 1.25” FROM LEFT EDGE
BLACK ON WHITE
RJS
RCA
DECAL, WIRING
DIAGRAM, 575V
15.25 X 7.0
1 OF 1
NTS
B
111379.0001
.25 TYPICAL
EXTRA
BACKING
15.25" +/- .060"
LABEL SIZE
7.00" +/- .060"
LABEL SIZE
+24
VDC
STB
ENAB
TROUBLESHOOTING LED’s
+ 24 VOLTS
DC
STB
ENABLE
ON
=
STB ENABLED
OFF
=
STB DISABLED
ON
=
POWER AVAILABLE
OFF
=
CHECK AC POWER
SUPPLY. CHECK FUSES
GDB - 2.5A or
S500 - 2.5A
EXTERNAL
RADIO
CONNECTOR
BRAKE
CONNECTOR
SECONDARY FUSE
RADIO FUSE
EXTERNAL ANTENNA
CONNECTION
HOIST
INTERLOCK
CONNECTOR
EXPANSION
BOARD PORT
LIMIT SENSOR
CONNECTOR
LINE
GROUND
TRANSFORMER
CONTROL WIRE
TERMINALS
ROUTE HIGH
VOLTAGE WIRES
THROUGH THIS
SHADED AREA
ROUTE LOW
VOLTAGE WIRES
THROUGH THIS
SHADED AREA
MOTOR
CONNECTOR
575V 3PH
GDB - 250 mA OR
S504 - 250 mA
(COAX)
TRANSFORMER
CONNECTORS
INPUT POWER
TERMINALS
INTERNAL
RADIO BOARD
LINE IN
POWER CONNECTIONS
L1
L2
GND
LINE 1
LINE 2 LINE 3
L3
(PLUG UNUSED HOLES)
(
PLUG UNUSED HOLES)
NOT FOR RESIDENTIAL USE
1-BTN
STATION
KEY
SWITCH
STATION
CARD
READER
O/C
PULL
SWITCH
N/O
N/O
N/O
N/O
REMOVE
JUMPER
WHEN
INSTALLING
EXTERNAL
INTERLOCK
EXTERNAL WIRING DIAGRAM
MULTIPLE
3-BUTTON
STATION
INSTALLATIONS
REQUIRE THE
STOP BUTTON
TO BE WIRED
IN SERIES.
See Fig. 5, pg 5.4
*
EXT
INTLK
EXT
INTLK
N-O
REVERSE
N-O
REVERSE
ODC
STB
ODC
STB
1-BTNGNDSTOPCLOSEOPEN
EXT RADIO CONNECTOR
SENSING EDGE SWITCH
(DO NOT CONNECT
2-WIRE MONITORED
SENSING EDGE SWITCH
TO THESE INPUTS)
PWR
RAD
GND
GND
THRU-BEAM
PHOTOCELLS
+
-
+
-
PWR
20-40 VDC @ 250mA
MAX CURRENT
RELAY
GND
NOM
+ 24VDC
RADIO
SERIES II SAFE-T-BEAM
®
(STB)
(
*
CONNECT STB WIRES
TO EITHER TERMINAL)
*
OPEN
CLOSE
STOP
REMOVE
JUMPER
IF STOP
BUTTON
IS USED
3-BUTTON
STATION
*
WARNING: FOR CONTINUED PROTECTION AGAINST FIRE, REPLACE FUSES ONLY WITH THE SAME TYPE AND RATING
P/N 111379.0001
EXPANSION
MODULE
MOUNTING
LOCATIONS
TROUBLE-
SHOOTING
LEDs
L1 L2 L3
NOTE: CIRCLED DIMENSIONS DESIGNATE CTQ,
(CRITICAL TO QUALITY) SPECIFICATIONS
575V
A 36497 REMOVED OPTIONAL TRANSFORMER
RJS 10-23-08
4/07/08
9/8/08
RCA 10/24/08
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

Genie GCL-T Product information

Type
Product information
This manual is also suitable for

Genie GCL-T is a heavy-duty, trolley-style garage door opener designed for commercial applications. It boasts a powerful 1/2 HP motor capable of lifting doors weighing up to 600 lbs. It features adjustable speed and force settings, allowing for precise control over the door's movement. The GCL-T includes a wireless keypad and two pre-programmed remotes for easy access. It also has a built-in obstruction detection system to ensure safe operation.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI