Eaton CHU1S Specification

Type
Specification
Power
Outlet
Panels
Product Guide
Construction and Recreational Vehicle (RV) Power Outlet Panels
Vehicle Power (RV) Power Outlet Panels
Marina Power Outlet Panels
1 POWER OUTLET PANELS PG.33.01.P.K – January 2011 www.eatoncanada.ca
Power Outlet Panels
Construction and RV Power Outlet Panels
Construction and RV Power
Outlet Panels
Product Description
A Power Outlet Panel (or
POP) is a device designed
for outdoor service to meet
temporary power requirements
at construction sites and
recreational vehicle (RV) parks.
Construction sites and RV
parks need to provide a safe
and reliable means for users to
access electricity and Power
Outlet Panels provide the outlets
for electrical access.
Application Description
Power Outlet Panels (POPs)
are also sometimes called
Temporary Power Panels,
Temporary Site Service
Equipment or RV (Recreational
Vehicle) Panels.
When Power Outlet Panels are
used at a construction site, they
are installed on a temporary
basis until electrical power is
available at the building. The
most common reason for
needing a Power Outlet Panel
at a construction site is to
provide a power source for the
contractor’s tools.
When POPs are used at an RV
park, they are installed for more
permanent use and serve the
purpose of providing power to
a vehicle’s appliances. Many
RV parks now supply users
with lighted POPs with TV
and telephone jacks. A move
towards offering more amenities
at RV parks.
Features, Functions, and
Benefits
• Designedforoutdoor
service to meet power outlet
requirements.
• Receptaclesconform
to NEMA
®
and/or ANSI
configurations.
• Includesafactoryinstalled
insulated neutral bar.
• 125ampereratedmeter
socket.
• FactoryinstalledtypeBR
(Non-GFCI) or type GFCB
(Ground Fault) circuit breakers.
• Panelscomefromthefactory
completely assembled,
prewired with 100 percent
copper wire, and tested ready
for easy installation.
• Doorswingsupandopenfor
user convenience and ease
of access to breakers and
receptacles.
• Panelscanbebottomfed
through knockouts in endwall
or top fed using a bolt-on
raintight hub.
• Two-piecedeadfrontcover
allows field wiring without
interfering with factory wiring.
• Lowerdeadfrontcover
permits easy field wiring to
circuit protective devices.
• GFI(groundfaultinterrupter)
1- and 2-pole protection
through 50 amperes.
• Enclosuresaremanufactured
from 16 gauge G90 galvanized
steel
• Pedestalmountstyleunits
come standard with loop
feed lug assembly that
accommodates #6-350MCM
cabling.
Standards and Certifications
• cUL
®
rated
• CSA
®
Certified, File Number
077961
• ULStandard231
• ULFileNumberE163588
• Receptaclesconform
to NEMA
®
and/or ANSI
configurations as specified
bytheUSNationalElectrical
Code (NEC)
•100percentgalvanizedsteel
with baked-on polyester
powder coating.
•Three-pointmounting.
•One-piececasebackforme-
tered and unmetered panels.
•Lightedoptionforsitelocation
and nighttime panel operations.
•GFIcircuitbreakersavailable
through 50 amperes (Type
GFCB).
•Uniquesteelbarrierprevents
unauthorized operation of
breakers when door is closed
and padlocked.
•Meteredunitsavailablewith
meter on top or on bottom.
Figure 1. Power Outlet Panel Features (Surface Mount Unit Pictured)
•NEMA3Rconstructionfor
rainproof installation.
•Utilitygrademeteringavail-
able for construction site RV
park applications.
•Doorswingsupandpushes
in to lock in the open position.
Pull out and push down to
close door.
•Removableupperdeadfront
cover for easy incoming wire
connections to breaker
terminals.
•Lowerdeadfrontcoverrotates
90 degrees or can be removed
for easy routing of incoming
wires or receptacle changeouts.
•Padlockprovisionstoprevent
unauthorized entry.
•Unitsarefactorywiredand
assembled.
•Unitsaredesignedfortopor
bottom cable entry.
Note: NEMA
®
is a registered trademark and service mark of the National Electrical
Manufacturers’ Association.
CSA
®
and UL
®
are federally registered trademarks of the Canadian Standards Association and
Underwriters Laboratories Inc. respectively.
All other trademarks are property of their respective owners.
Note: This product is not service
entrance approved..
POWER OUTLET PANELS PG.33.01.P.K – January 2011 www.eatoncanada.ca 2
Power Outlet Panels
Construction and RV Power Outlet Panels
Product Specifications
The power outlet panels shall
be designed for outdoor service
to meet temporary power outlet
requirements at construction
sites and provide high quality,
economical power to individual
sites at recreational vehicle (RV)
parks. RV panels shall have a
factory-installed insulated neutral
bar.
Receptacles and Circuit
Protection
The circuit protection shall be
Eaton’sCSA/ULlistedfull-size
type BR or, half-size type DNPL
circuit breakers. The receptacles
shall be NEMA commercial/
industrial grade and come in a
variety of configurations. Ground
fault protection can be provided
at the 20 ampere NEMA 5-20R
receptacle or, at the circuit
breaker for all other receptacles.
Construction
The power outlet panel pedestal
shall be of deadfront design and
constructed of heavy gauge,100
percent galvanized steel. Baked-
on polyester powder coating
shall be used for excellent
mechanical strength, plus
resistance to chalking caused
by the sun’s ultraviolet rays. The
power outlet panel surface and
pedestal units shall have NEMA
Type 3R rainproof enclosures.
Ease of Installation
Panels shall ship from the
factory completely assembled,
prewired with 100 percent
copper wire, and tested in
accordancewithULStandard
231. Door shall swing up and
open for user convenience and
ease of access to breakers and
receptacles. When required, a
means for securing the door
in the open position shall be
provided. Panels shall be bottom
fed through knockouts in
endwall or top fed using a bolt-
on raintight hub. Knockouts shall
range from 1/2-inch (12.7 mm) to
1-1/2 inches (38.1 mm). #4 – 14
Cu/Al grounding provisions shall
be provided on all panels.
Single Receptacle Style Surface Mount Unmetered
Style
Surface Mount Metered Style Pedestal Mount Unmetered
Style
3 POWER OUTLET PANELS PG.33.01.P.K – January 2011 www.eatoncanada.ca
Power Outlet Panels
Construction and RV Power Outlet Panels
Product Selection
When quoting or selecting a Power Outlet Panel, the following items
should be considered:
• Unmetered,Metered.
• Numberandtypeofreceptacles(6standardand8twist-lock
options).
• StandardorGroundFaultCircuitBreakers.
• Additionalspaceforeldmountedcircuitbreakers.
• Surface,Pedestal,orBack-to-BackMounting.
Table 1. Construction and RV Power Outlet Panel Catalogue
Number System
Metering Type
U = Unmetered
M = Metered
Left Position
Receptacle Type
1 = NEMA 14-50R
3 = NEMA 14-30R
4 = NEMA TT-30R
5 = NEMA 6-20R2
6 = NEMA 5-20R2
7 = NEMA 5-20R2GFI
A = NEMA L14-50R
B = NEMA L6-50R
C = NEMA L5-50R
D = NEMA L14-30R
E = NEMA L6-30R
F = NEMA L5-30R
G = NEMA L6-20R
H = NEMA L5-20R
Blank = No Receptacle
Centre Position
Receptacle Type
1 = NEMA 14-50R
3 = NEMA 14-30R
4 = NEMA TT-30R
5 = NEMA 6-20R2
6 = NEMA 5-20R2
7 = NEMA 5-20R2GFI
A = NEMA L14-50R
B = NEMA L6-50R
C = NEMA L5-50R
D = NEMA L14-30R
E = NEMA L6-30R
F = NEMA L5-30R
G = NEMA L6-20R
H = NEMA L5-20R
Blank = No Receptacle
Right Position
Receptacle Type
1 = NEMA 14-50R
3 = NEMA 14-30R
4 = NEMA TT-30R
5 = NEMA 6-20R2
6 = NEMA 5-20R2
7 = NEMA 5-20R2GFI
A = NEMA L14-50R
B = NEMA L6-50R
C = NEMA L5-50R
D = NEMA L14-30R
E = NEMA L6-30R
F = NEMA L5-30R
G = NEMA L6-20R
H = NEMA L5-20R
Blank = No Receptacle
Circuit Breaker Type
Position 1
N = Non-Ground Fault
G = Ground Fault
Circuit Breaker Type
Position 2
N = Non-Ground Fault
G = Ground Fault
Circuit Breaker
Type Position 3
N = Non-Ground Fault
G = Ground Fault
Mounting Style
S = Surface Mount
P = Pedestal Mount
B = Back-to-Back Pedestal Mount
Circuit Breaker Interior
X = Six Circuit
Blank = Four Circuit (Standard)
Illumination Option
L = Lighted
Blank = No Lighting
Pedestal Extension
TZ = Factory Installed Extension
Blank = No Extension
CH U 1 N 7 N 4 N P X L TZ
Not all option combinations are possible. Contact your Eaton sales rep for confirmation of
correct catalogue number selection.
For receptacle configurations, see table 2.
POWER OUTLET PANELS PG.33.01.P.K – January 2011 www.eatoncanada.ca 4
Power Outlet Panels
Construction and RV Power Outlet Panels
Product Selection Continued
Table 2. Standard Receptacle Configurations
Catalogue Number Code Blade Arrangement NEMA Designation Description Feeder Circuit Breaker
1 14-50R 50 Amperes, 125/250 Volts, 3-Pole, 4-Wire 2-Pole 50 Amperes
3 14-30R 30 Amperes, 125/250 Volts, 3-Pole, 4-Wire 2-Pole 30 Amperes
4 TT-30R 30 Amperes, 125/250 Volts, 2-Pole, 3-Wire 1-Pole 30 Amperes
5 6-20R2 20 Amperes, 250 Volts, 2-Pole, 3-Wire 2-Pole 20 Amperes
6 5-20R2 20 Amperes, 125 Volts, 2-Pole, 3-Wire (Non-GFI) 1-Pole 20 Amperes
7 5-20R2GFI 20 Amperes, 125 Volts, 2-Pole, 3-Wire (w/GFI) 1-Pole 20 Amperes
Table 3. Locking Receptacle Configurations
Catalogue Number Code Blade Arrangement NEMA Designation Description Feeder Circuit Breaker
A L14-50R 50 Amperes, 125/250 Volts, 3-Pole, 4-Wire, Grounding 2-Pole 50 Amperes
B L6-50R 50 Amperes, 125/250 Volts, 2-Pole, 3-Wire, Grounding 2-Pole 50 Amperes
C L5-50R 50 Amperes, 125 Volts, 2-Pole, 3-Wire, Grounding 2-Pole 50 Amperes
D L14-30R 30 Amperes, 125/250 Volts, 3-Pole, 4-Wire, Grounding 2-Pole 30 Amperes
E L6-30R 30 Amperes, 250 Volts, 2-Pole, 3-Wire, Grounding 1-Pole 30 Amperes
F L5-30R 30 Amperes, 125 Volts, 2-Pole, 3-Wire, Grounding 1-Pole 30 Amperes
G L6-20R 20 Amperes, 250 Volts, 2-Pole, 3-Wire, Grounding 2-Pole 20 Amperes
H L5-20R 20 Amperes, 125 Volts, 2-Pole, 3-Wire, Grounding 1-Pole 20 Amperes
Breakers used are BR type.
5 POWER OUTLET PANELS PG.33.01.P.K – January 2011 www.eatoncanada.ca
Power Outlet Panels
Construction and RV Power Outlet Panels
Product Selection Continued
Table 4. Construction and RV Power Outlet Panel Catalogue Number Selection Examples
Mounting Metering Catalogue Receptacle and Circuit Breaker Description Light Factory 2, 4, Dim.
Number Left Position Centre Position Right Position Pedestal or 6 Figure
Extension Circuit
Interior
Surface Unmetered CHU1S Receptacle NA 50A, 14-50R NA NA NA NA 2
Circuit Breaker NA NA NA
Surface Unmetered CHUDS Receptacle NA 30A, L14-30R NA NA NA NA 2
Circuit Breaker NA NA NA
Surface Unmetered CHU4N7NS Receptacle 30A, TT-30R 20A, 5-20R2GFI No NA 2 3
Circuit Breaker BR130 BR120
Surface Unmetered CHUFN6G6GS Receptacle 30A, L5-30R 20A, 5-20R2 20A, 5-20R2 No NA 4 4
Circuit Breaker BR130 BR120
Surface Metered CHM1N7NS Receptacle 50A , 14-50R 20A, 5-20R2GFI No NA 4 5
Circuit Breaker BR250 BR120
Surface Metered CHM1N7N4NSL Receptacle 50A , 14-50R 20A, 5-20R2GFI 30A, TT-30R Yes NA 4 5
Circuit Breaker BR250 BR120 BR130
Pedestal Unmetered CHU4G6GP Receptacle 30A, TT-30R 20A, 5-20R2 No No 4 6
Circuit Breaker GFCB130 GFCB120
Pedestal Unmetered CHU1N7N4NPTZ Receptacle 50A , 14-50R 20A, 5-20R2GFI 30A, TT-30R No Yes 4 6
Circuit Breaker BR250 BR120 BR130
Pedestal Metered CHMAN6GP Receptacle 50A , L14-50R 20A, 5-20R2 No No 4 7
Circuit Breaker BR250 GFCB120
Pedestal Metered CHM1N7N4NPX Receptacle 50A , 14-50R 20A, 5-20R2GFI 30A, TT-30R No No 6 7
Circuit Breaker BR250 BR120 BR130
Back-to-Back Unmetered CHU6G6GB Receptacle 20A, 5-20R2 20A, 5-20R2 No No 4 8
Circuit Breaker GFCB120 GFCB120
Back-to-Back Unmetered CHU4N7N4NBTZ Receptacle 30A, TT-30R 20A, 5-20R2GFI 30A, TT-30R No Ye
s 4 8
Circuit Breaker BR130 BR120 BR130
Back-to-Back Metered CHM4N6GB Receptacle 30A, TT-30R 20A, 5-20R2 No No 4 9
Circuit Breaker BR130 GFCB120
Back-to-Back Metered CHM1N7N4NBLTZ Receptacle 50A , 14-50R 20A, 5-20R2GFI 30A, TT-30R Yes Yes 4 9
Circuit Breaker BR250 BR120 BR130
POWER OUTLET PANELS PG.33.01.P.K – January 2011 www.eatoncanada.ca 6
Power Outlet Panels
Construction and RV Power Outlet Panels
Dimensions
Figure 2. Single Receptacle Style Power Outlet Panel (In [mm])
7 POWER OUTLET PANELS PG.33.01.P.K – January 2011 www.eatoncanada.ca
Power Outlet Panels
Construction and RV Power Outlet Panels
Dimensions Continued
Figure 3. Surface Mount Unmetered Style Power Outlet Panel (Two Circuit Interior) (In [mm])
Figure 4. Surface Mount Unmetered Style Power Outlet Panel (Four or Six Circuit Interior)
(In [mm])
11.75
(298.5)
6.25
(158.8)
4.25
(108.0)
POWER OUTLET PANELS PG.33.01.P.K – January 2011 www.eatoncanada.ca 8
Power Outlet Panels
Construction and RV Power Outlet Panels
Figure 5. Surface Mount Metered Style Power Outlet Panel (In [mm])
Figure 6. Pedestal Mount Unmetered Style Power Outlet
Panel (In [mm])
Figure 7. Pedestal Mount Metered Style Power Outlet Panel
(In [mm])
Dimensions Continued
Sealing
Provision
25.80
(655.3)
16.90
(429.3)
44.50
(1130.3)
52.00
(1320.8)
9.50
(241.3)
5.00
(127.0)
6.80
(172.7)
4.30
(109.2)
Locking
Provision
22.00
(558.8)
9 POWER OUTLET PANELS PG.33.01.P.K – January 2011 www.eatoncanada.ca
Power Outlet Panels
Construction and RV Power Outlet Panels
Dimensions Continued
13.60
(345.4)
8.60
(218.4)
19.20
(487.7)
3.30
(83.8)
.75
(19.1)
17.10
(434.3)
9.50
(241.3)
Locking
Provision
52.00
(1320.8)
25.80
(655.3)
16.90
(429.3)
44.50
(1130.3)
9.50
(241.3)
Sealing Provision
3.30
(83.8)
.75
(19.1)
22.00
(558.8)
19.30
(490.2)
22.50
(571.5)
Sealing
Provision
41.80
(1061.7)
30.00
(762.0)
Locking
Provision
8.60
(218.4)
9.90
(251.5)
13.60
(345.4)
9.50
(241.3)
Figure 8. Back-to-Back Mount Unmetered Style Power Outlet Panel (In [mm])
Figure 9. Back-to-Back Mount Metered Style Power Outlet Panel (In [mm])
POWER OUTLET PANELS PG.33.01.P.K – January 2011 www.eatoncanada.ca 10
Power Outlet Panels
Construction and RV Power Outlet Panels
Accessories
Table 5. Construction and RV Power Outlet Panel Accessories
1-Phase 2-Wire – 240V AC
Catalogue Number Description
CHPEDEXT Underground Pedestal Extension
CHPEDEXTSS Underground Pedestal Extension (Stainless Steel)
CHPADEXT Pad Mounting Bracket
CHTELTV Cable TV and Telephone Bracket
DS075H1 Rainproof Conduit Hub 0.75 Inch (19.1mm)
DS100H1 Rainproof Conduit Hub 1 Inch (25.4mm)
DS125H1 Rainproof Conduit Hub 1.25 Inch (31.8mm)
DS150H1 Rainproof Conduit Hub 1.5 Inch (38.1mm)
CHFLGTKIT
Fluorescent Light Kit (Converts A Power Outlet Panel To A Lighted Unit)
Pedestal Extension
Pad Mounting Bracket
Cable TV and Telephone
Bracket
Conduit Hub
11 POWER OUTLET PANELS PG.33.01.P.K – January 2011 www.eatoncanada.ca
Power Outlet Panels
Construction and RV Power Outlet Panels
Catalogue Number Description
CHPOPMS
Replacement Meter Socket
CHPOPMSN
Replacement Meter Socket
ARP00039CH
Replacement Meter Socket (1 Block Assembly Per Kit)
1MM5JKOP
5th Jaw Kit
ARP00035CHJ

5th Jaw Kit
CHBONDST Bonding Strap and Mounting Hardware
CHINLENS Inner Lens for Lighted Power Outlet Panels
CHLOOPFDP Loop Feed Lug Assembly for Single Pedestal
CHLOOPFDB Loop Feed Lug Assembly for Back-to-Back Pedestal
CHLDFCVR Blank Lower Deadfront Cover
CHLDFCVR1 Lower Deadfront Cover with Duplex Receptacle Opening
CHLDFCVR2 Lower Deadfront Cover with Duplex, Duplex Receptacle Opening
CHLDFCVR3 Lower Deadfront Cover with Duplex, Duplex, Duplex Receptacle Opening
CHLDFCVR4 Lower Deadfront Cover with Rectangle Receptacle Opening
CHLDFCVR5 Lower Deadfront Cover with Rectangle, Rectangle Receptacle Opening
CHLDFCVR6 Lower Deadfront Cover with Rectangle, Rectangle, Rectangle Receptacle Opening
CHLDFCVR7 Lower Deadfront Cover with Duplex, Rectangle Receptacle Opening
CHLDFCVR8 Lower Deadfront Cover with Duplex, Rectangle, Duplex Receptacle Opening
CHLDFCVR9 Lower Deadfront Cover with Rectangle, Rectangle, Duplex Receptacle Opening
CHLDFCVR10 Lower Deadfront Cover with Round Receptacle Opening
CHLDFCVR11 Lower Deadfront Cover with Round, Round Receptacle Opening
CHLDFCVR12 Lower Deadfront Cover with Round, Duplex Receptacle Opening
CHLDFCVR13 Lower Deadfront Cover with Round, Duplex, Duplex Receptacle Opening
CHLDFCVR14 Lower Deadfront Cover with Round, Duplex, Round Receptacle Opening
CHLDFCVR15 Lower Deadfront Cover with Round, Rectangle Receptacle Opening
CHLDFCVR16 Lower Deadfront Cover with Round, Rectangle, Rectangle Receptacle Opening
CHLDFCVR17 Lower Deadfront Cover with Round, Rectangle, Round Receptacle Opening
CHLDFCVR18 Lower Deadfront Cover with Round, Rectangle, Duplex Receptacle Opening
CHUDFCVR Upper Deadfront Cover with Six Breaker Twistouts
CHUDFCVRL Upper Deadfront Cover with Provisions for Lighted Option
CHOUTCVR Power Head Outer Cover
CHOUTCVRL Power Head Outer Cover with Lens
CHNEUT 6-Hole Neutral Assembly with 2/0 Lug
CHNEUT1 7-Hole Neutral Assembly with 2/0 Lug
GBK5 5-Hole Ground Bar Kit
GBK10 10-Hole Ground Bar Kit
CHPOPRMC Replacement Meter Cover
For Power Outlet Panels manufactured before December 1, 2002.
For Power Outlet Panels manufactured after December 1, 2002.
For Power Outlet Panels with a date code ending in “L”.
For Power Outlet Panels with a date code not ending in “L”.
For Power Outlet Panels ordered after January 1, 2005.
Table 6. Construction and RV Power Outlet Panel Replacement Parts
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

Eaton CHU1S Specification

Type
Specification

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI