Pulsar AMC INSIDE 130 User manual

Type
User manual

This manual is also suitable for

1
The exclusive distributor of AMC products
INSIDE 130
External optical and acoustic signaling device (PIEZO
transducer, 105dB; LED; no metal enclosure; optional
connection of the 12V/2,2Ah battery)
CODE
INS130
In accordance with the
EN 50131-4 standard
MANUAL EN
Edition: 2 from 07.03.2014
Supersedes: 1 from 10.02.2014
1. Introduction
The external optical and acoustic signaling device INSIDE130 is designed for Intrusion Detection Systems. It
is available in one color: white enclosure, red optical indicator.
Acoustic indication is based on a piezoelectric transducer. The sound intensity, generated by signaling
device, is 105 dB at 1 meter distance.
Optical indication uses modern super-bright LEDs instead of the usual light bulbs so that the light of the
signaling device is clearly visible and the device is characterized by a low level of power consumption and
high reliability.
2
2. Installation
The signaling device should be mounted by a qualified installer, holding relevant permits and licenses
(applicable and required for a given country) for Intrusion Detection Systems.
The mounting location of the signaling device should be inaccessible in order to minimize the risk of
tampering. The signaling device should be mounted on a flat surface using expansion bolts.
In order to open the enclosure of the INSIDE 130, bend the cap (Fig. 1a) unscrew the locking screw and
bend the upper part of the enclosure (lid) upwards.
Caution! When mounting, keep an appropriate distance (minimum 5 cm) between the top edge of the
enclosure of the signaling device and the ceiling or other structures located above, so that re-mounting of the
enclosure after installation and configuration of the device will be possible. When mounting, pay attention to
correct positioning of the tamper.
The view of the signaling device is shown in the pictures below.
Fig. 1a
The signaling device – front view
Fig. 1b
The signaling device without enclosure
Fig. 1c
The printed circuit board of the signaling device.
3
Description of terminals:
TAMPER: tamper terminals (N.C.) of the signaling device (indicating enclosure opening and detachment
from the wall)
S – the triggering signal terminal (see Table 2)
- + –13,8VDC power supply input (battery operation)
- BAT + – wires for connecting the batteries (12VDC / 2,2Ah)
Power supply of the signaling device is supplied to the „+” and „- terminals
The signaling device can operate with or without the 12V/2,2Ah battery. The battery should be
connected to the „-BAT+” socket.
Caution! During battery operation, the power supply voltage should be between 13V and 13.8V to ensure
proper charging process.
3. Configuration of the signaling device
The configuration of the INSIDE 130 signaling device is using the DIP-SWITCH switches
(see Table 1a and 1b), which are placed on the Printed Circuit Board (Fig. 1c).
DIP SWICH OFF
DIP SWICH ON
The standby mode (Standby) - DIP1
Due to the low level of power consumption, the manufacturer introduced an additional indication of
the Intrusion Detection System status. The DIP1 dip-switch allows launching the so-called standby mode. In
this mode, the signaling device emits light at a fixed frequency (1 flash every 4 seconds) to indicate that the
system is powered on and working properly.
Table 1a
Activating the signaling device - DIP1, DIP2
The DIP2 and DIP3 micro switches are used to select a method for activating the signaling device
(see Table 1b).
Table 1b
ACTIVATION OF THE SIGNALING DEVICE
the DIP switch
Position
DIP 2 DIP 3
2 3
OFF OFF Removing the „+ from the S contact
ON OFF Giving a „+” to the S contact
OFF ON Giving a „-” to the S contact (shorting the contact
to ground)
ON ON Removing the „-” from the S contact (opening the
contact from ground)
the DIP switch
Position
STANDBY MODE (standby)
1
DIP 1 ON – standby mode ON,
OFF – standby mode OFF
4
The diagram of connecting the signaling device to the control panel.
The control panel outputs OUT3 and OUT5 enable the +12V power supply of the signaling device.
The OUT3 output is programmed as power supply output. The "S" control input, which is shorted to ground, is
used to control the signaling device. Normally, when the signaling device is inactive (no alarm) there is +12 V
supplied at the "S" input via the 1 bias resistor from the OUT3 output. By controlling the OUT5 output
(shorting the output to ground), which is connected via the 1kΩ resistor, it is possible to force the "S" input to
a low state, which results in activation of the signaling device.
4. Technical data
Signaling device type INSIDE130
Supply voltage 13,8VDC
Permissible supply voltage range 11VDC÷15VDC
Maximum current consumption 800mA
Power consumption in standby mode 8mA
Sound intensity 105dB at 1m distance (Un=13,8VDC) 5’ ± 20%
In accordance with the standard EN 50131-4 Grade 2
optional connection of the battery YES (12VDC/ 2,2 Ah battery), not included
Dimensions (H x W x D) 220 x 330 x 60mm
Weight 0,7kg
Operating temperature - 40°C÷55°C
In accordance with the standards:
CEI EN 50131-4:2010-08
Grade 2
Class 4
RoHS
Additional information
The manufacturer takes no responsibility for the defects that result from the damaging, malfunctioning or
inability to operate the equipment especially when resulting from failure to comply with the recommendations
and requirements contained in the manual.
It is necessary to periodically test the signaling device. The majority of Intrusion Detection Systems
indicates malfunctioning of the signaling devices and informs the user with an appropriate message on the
LCD keypad or LED light on the LED display. In case of such situation, the system installer shall be
immediately notified. Testing and control methods of Intrusion Detection Systems are specifically determined
by the installer.
The INSIDE signaling device was made in accordance with the requirements of the EEC and 99/5/CE
directives. The Declaration of Conformity is available at www.pulsar.pl
5
WEEE LABEL
Waste electrical and electronic equipment must not be disposed of with normal
household waste. According to the European Union WEEE Directive, waste electrical
and electronic equipment should be disposed of separately from normal household
waste.
The exclusive distributor of AMC products:
Pulsar K. Bogusz Sp.j.
Siedlec 150, 32-744 Łapczyca, Poland
Phone (+48) 14-610-19-40, Fax (+48) 14-610-19-50
E-mail: biuro@pulsar.pl, sales@pulsar.pl
www.pulsar.pl, www.zasilacze.pl
GENERAL WARRANTY CONDITIONS
1. Pulsar K. Bogusz Sp.j. (manufacturer) grants a two-year quality warranty for the equipment, starting from the production
date.
2. The warranty includes free-of-charge repair or replacement with an appropriate equivalent (selected by the manufacturer) if
the malfunction is due to the manufacturer. It includes manufacturing or material defects, provided that such defects have
been reported within the warranty period (point.1).
3. The equipment subjected to warranty should be brought to the place of purchase or directly to the main office of the
manufacturer.
4. The warranty applies to complete equipment, accompanied by a properly filled warranty claim with a description of the
defect.
5. Should the claim be accepted, the manufacturer is obliged to provide warranty repairs, at the earliest convenience,
however not later that within 14 days from the delivery to the service centre of the manufacturer.
6. The repair period mentioned in point 5 may be prolonged, if there are no technical possibilities to carry out the repairs, or if
the equipment has been conditionally accepted, due to the breaking warranty terms by the claimant.
7. All the services are carried out at the service centre of the manufacturer, exclusively.
8. The warranty does not cover the defects of the equipment, resulting from:
- reasons beyond the manufacturer's control,
- mechanical damage,
- improper storage and transport,
- use that violates the operation manual or equipment’s intended use
- fortuitous events, including lightning discharges, power failures, fire, flood, high temperatures and chemical agents,
- improper installation and configuration (failure to follow instruction).
9. The warranty is void in case of construction changes and repairs carried out by any unauthorized service center or in case
of damage or modifications to warranty stickers and serial numbers.
10. The liability of the manufacturer towards the buyer is limited to the value of the equipment determined according to the
wholesale prices suggested by the manufacturer on the day of purchase.
11. The manufacturer takes no responsibility for the defects that result from the damaging, malfunctioning or inability to
operate the equipment especially when resulting from failure to comply with the recommendations and requirements
contained in the manual.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5

Pulsar AMC INSIDE 130 User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI