Klimaire KSID022-H115 -O / -I User manual

Category
Split-system air conditioners
Type
User manual
0
Model Numbers:
KSID012-H115Q KSID016-H215Q
KSID022-H215Q
KSID MINI
Split DC Inverter
QUICK CONNECT Air Conditioner
SERVICE
MANUAL
Table of Contents
1. Precaution
2. Part names and functions
3. Dimension
4. Refrigerant Cycle Diagram
5. Wiring Diagram
6. Installation Details
7. Operation Characteristics
8. Electronic function
9. Troubleshooting
10. Exploded view
11. Disassembly Instructions
WARNING
Installation MUST conform with local building codes or, in the absence of local codes, with the
National Electrical Code NFPA70/ANSI C1-1993 or current edition and Canadian Electrical
Code Part1 CSA C.22.1.
The information contained in the manual is intended for use by a qualified service technician
familiar with safety procedures and equipped with the proper tools and test instruments
Installation or repairs made by unqualified persons can result in hazards to you and others.
Failure to carefully read and follow all instructions in this manual can result in equipment
malfunction, property damage, personal injury and/or death.
This service is only for service engineer to use.
CONTENTS
1. Precaution ..................................................................................................................................................... 1
1.1 Safety Precaution .......................................................................................................................... 1
1.2 Warning ......................................................................................................................................... 1
2. Part Names And Functions .......................................................................................................................... 2
2.1 Model Names of Indoor/Outdoor units .......................................................................................... 2
2.2 Part names of Indoor/Outdoor units .............................................................................................. 2
2.3 Functions of Indoor/Outdoor units ................................................................................................ 3
3. Dimension ..................................................................................................................................................... 6
3.1 Indoor Unit ..................................................................................................................................... 6
3.2 Outdoor Unit .................................................................................................................................. 8
4. Refrigerant Cycle Diagram .......................................................................................................................... 9
5. Wiring Diagram ...........................................................................................................................................10
5.1 Indoor Unit ................................................................................................................................... 10
5.2 Outdoor Unit ................................................................................................................................ 13
6 Installation Details .......................................................................................................................................16
6.1 Wrench torque sheet for installation ........................................................................................... 16
6.2 Connecting the cables ................................................................................................................ 16
6.3 Installation for the first time ......................................................................................................... 16
6.4 Adding the refrigerant after running the system for many years ................................................ 17
6.5 Re-installation while the indoor unit need to be repaired ........................................................... 18
6.6 Re-installation while the outdoor unit need to be repaired ......................................................... 19
7. Operation Characteristics ..........................................................................................................................20
8. Electronic Function ....................................................................................................................................21
8.1 Abbreviation ................................................................................................................................ 21
8.2 Display function ........................................................................................................................... 21
8.3 Main Protection ........................................................................................................................... 22
8.4 Operation Modes and Functions................................................................................................. 23
9. Troubleshooting..........................................................................................................................................30
9.1 Indoor Unit Error Display ............................................................................................................ 31
9.2 Outdoor unit error display ........................................................................................................... 32
9.3 Diagnosis and Solution ............................................................................................................... 36
10. Exploded View ..........................................................................................................................................57
10.1 Indoor unit ................................................................................................................................. 57
10.2 Outdoor unit .............................................................................................................................. 63
11 Disassembly Instructions .........................................................................................................................68
11.1 Indoor unit ................................................................................................................................. 69
11.2 Outdoor unit ............................................................................................................................... 73
1
1. Precaution
1.1 Safety Precaution
To prevent injury to the user or other
people and property damage, the following
instructions must be followed.
Incorrect operation due to ignoring
instruction will cause harm or damage.
Before service the unit, be sure to
read this service manual at first.
1.2 Warning
Installation
Do not use a defective or underrated
circuit breaker. Use this appliance on a
dedicated circuit.
There is risk of fire or electric shock.
For electrical work, contact the dealer,
seller, a qualified electrician, or an
authorized service center.
Do not disassemble or repair the product,
there is risk of fire or electric shock.
Always ground the product.
There is risk of fire or electric shock.
Install the panel and the cover of
control box securely.
There is risk of fire of electric shock.
Always install a dedicated circuit and
breaker.
Improper wiring or installation may cause
electric shock.
Use the correctly rated breaker of
fuse.
There is risk of fire or electric shock.
Do not modify or extend the power
cable.
There is risk of fire or electric shock.
Do not install, remove, or reinstall the
unit by yourself (customer).
There is risk of fire, electric shock, explosion,
or injury.
Be caution when unpacking and
installing the product.
Sharp edges could cause injury, be especially
careful of the case edges and the fins on the
condenser and evaporator.
For installation, always contact the
dealer or an authorized service center.
Do not install the product on a
defective installation stand.
Be sure the installation area does not
deteriorate with age.
If the base collapses, the air conditioner could
fall with it, causing property damage, product
failure, and personal injury.
Do not let the air conditioner run for a
long time when the humidity is very high
and a door or a window is left open.
Take care to ensure that power cable
could not be pulled out or damaged during
operation.
There is risk of fire or electric shock.
Do not place anything on the power
cable.
There is risk of fire or electric shock.
Do not plug or unplug the power
supply plug during operation.
There is risk of fire or electric shock.
Do not touch (operation) the product
with wet hands.
Do not place a heater or other
appliance near the power cable.
There is risk of fire and electric shock.
Do not allow water to run into
electrical parts.
It may cause fire, failure of the product, or
electric shock.
Do not store or use flammable gas or
combustible near the product.
There is risk of fire or failure of product.
Do not use the product in a tightly
closed space for a long time.
Oxygen deficiency could occur.
When flammable gas leaks, turn off
the gas and open a window for ventilation
before turn the product on.
If strange sounds or smoke comes
from product, turn the breaker off or
disconnect the power supply cable.
2
There is risk of electric shock or fire.
Stop operation and close the window
in storm or hurricane. If possible, remove
the product from the window before the
hurricane arrives.
There is risk of property damage, failure of
product, or electric shock.
Do not open the inlet grill of the
product during operation. (Do not touch the
electrostatic filter, if the unit is so equipped.)
There is risk of physical injury, electric shock,
or product failure.
When the product is soaked, contact
an authorized service center.
There is risk of fire or electric shock.
Be caution that water could not enter
the product.
There is risk of fire, electric shock, or product
damage.
Ventilate the product from time to
time when operating it together with a stove
etc.
There is risk of fire or electric shock.
Turn the main power off when
cleaning or maintaining the product.
There is risk of electric shock.
When the product is not be used for a
long time, disconnect the power supply plug
or turn off the breaker.
There is risk of product damage or failure, or
unintended operation.
Take care to ensure that nobody
could step on or fall onto the outdoor unit.
This could result in personal injury and
product damage.
CAUTION
Always check for gas (refrigerant)
leakage after installation or repair of
product.
Low refrigerant levels may cause failure of
product.
Install the drain hose to ensure that
water is drained away properly.
A bad connection may cause water leakage.
Keep level even when installing the
product.
It can avoid vibration of water leakage.
Do not install the product where the
noise or hot air from the outdoor unit could
damage the neighborhoods.
It may cause a problem for your neighbors.
Use two or more people to lift and
transport the product.
Do not install the product where it will
be exposed to sea wind (salt spray) directly.
It may cause corrosion on the product.
Corrosion, particularly on the condenser and
evaporator fins, could cause product
malfunction or inefficient operation.
Operational
Do not expose the skin directly to
cool air for long time. (Do not sit in the
draft).
Do not use the product for special
purposes, such as preserving foods, works
of art etc. It is a consumer air conditioner,
not a precision refrigerant system.
There is risk of damage or loss of property.
Do not block the inlet or outlet of air
flow.
Use a soft cloth to clean. Do not use
harsh detergents, solvents, etc.
There is risk of fire, electric shock, or damage
to the plastic parts of the product.
Do not touch the metal parts of the
product when removing the air filter. They
are very sharp.
Do not step on or put anything on the
product. (outdoor units)
Always insert the filter securely.
Clean the filter every two weeks or more
often if necessary.
A dirty filter reduces the efficiency of the air
conditioner and could cause product
malfunction or damage.
Do not insert hands or other objects
through air inlet or outlet while the product
is operated.
Do not drink the water drained from
the product.
3
Use a firm stool or ladder when
cleaning or maintaining the product.
Be careful and avoid personal injury.
Replace the all batteries in the remote
control with new ones of the same type. Do
not mix old and new batteries or different
types of batteries.
There is risk of fire or explosion.
Do not recharge or disassemble the
batteries. Do not dispose of batteries in a
fire.
They may burn of explode.
If the liquid from the batteries gets
onto your skin or clothes, wash it well with
clean water. Do not use the remote of the
batteries have leaked.
2
2. Part Names And Functions
2.1 Model Names of Indoor/Outdoor units
DC
Inverter
Capacity Indoor units Outdoor units
12k
KSID012-H115Q-I KSID012-H115Q-O
16k
KSID016-H215Q-I KSID016-H215Q-O
22k
KSID022-H215Q-I KSID022-H215Q-O
2.2 Part names of Indoor/Outdoor units
3
2.3 Functions of Indoor/Outdoor units
Ionizer(O)
Silver Ion Filter
Vitamin C Filter(O)
3M HAF Filter(O)
Bio Filter(O)
Golden Fin(O)
Cold Catalyst Filter
Compressor Crankcase Heater
(standard for 16k,21k)
Self Clean(O)
Follow Me(O)
8 Degree Heating(O)
Heat Compensation(O)
Self-diag. Function
PTC Heating Belt(O)
Filter
Louver Position Memory Function
Refrigerant Leakage Detect
O: optional function
4
Cold Catalyst Filter:
Eliminate formaldehyde and other volatile organic compounds as well as harmful gases and odors.
Ionizer:
Release negative ions, eliminate odor, dust, smoke and pollen particles to give you fresh and healthy air.
Silver Ion Filter:
Sterilize bacteria effectively by decomposing cell wall of bacteria.
Vitamin C Filter:
Release Vitamin C which can eliminate active oxygen to beautify the skin.
3M HAM Filter:
Open-hole-structure with charged electrostatic effectively capture dust and particles, ensure maximum air
flow and minimum pressure drop.
Bio Filter(O):
Bio filter consists of a specialized biological enzyme and Eco filter. The Eco filter catches very small
airborne dust particles and bacteria, fungi and microbes. Biological enzyme kills bacteria by dissolving their
cell wall thus eliminating the problem of re-pollution.
Golden Fin:
The Golden hydrophilic condenser can improve the heating efficiency by accelerating the defrosting
process. The unique anticorrosive golden coating on the condenser can withstand the salty air, rain and
other corrosive elements.
Self Clean:
When this function is activated, firstly the indoor unit operates as Fan-only mode with low fan speed, during
this period the condensed water will take some dust on evaporator fins away. After that the unit turns to
heating operation with low fan speed which dries the inside of indoor unit. Finally it turns to fan-only mode
and blows away the wet air. The whole process cleans the internal side of indoor unit and prevents the
breeding of bacteria.
Follow me:
With this technology, a temperature sensor is built in the remote control when you stay close to the remote
control, the unit will automatically change the operation mode to supply comfortable temperature just like
the air conditioner is following you.
Louver position memory function:
When starting the unit again after shutting down, its louver will restore to the angle originally set by the user
Refrigerant leakage detect:
The refrigerant leakage detect function can better prevent the compressor being damaged by refrigerant
leakage or compressor overload.
8 Degree Heating:
In heating operation, the preset temperature of the air conditioner can be as lower as 8°C, which keeps
the room temperature steady at 8°C for in winter.
Heat compensation:
Based on different installation height of indoor unit, the temperature deviation of the sensor sensed against
the actual floor temperature always is different. Changing the jumping wires combination on the indoor PCB
is possible to compensate the deviation. This could be achieved by installer in the installation field.
Self-diag.Function:
Monitoring some abnormal operations or parts failures, microcomputer of the air conditioner will switch off
and protect the system automatically.Meanwhile, the error or protection code will be displayed on the indoor
unit.
5
PTC heating belt:
With a PTC heating belt fitted on the base plate of the outdoor unit, the rain, snow or defrosted water
accumulating on the base plate is avoided.
Compressor crankcase heater:
The oil dissolves easily in refrigerant, especially in low temperature condition. The crankcase heating belt
can heat the bottom of the compressor to avoid pumping out too much oil with the refrigerant, which helps
to protect the compressor.
6
3. Dimension
3.1 Indoor Unit
W
D
H
Model W D H
KSID012-H115Q-I
770mm
(30.3in)
188mm
(7.4in)
255mm
(10.0in)
KSID016-H215Q-I
905mm
(35.6in)
198mm
(7.8in)
275mm
(10.8in)
KSID022-H215Q-I
1030mm
(40.6in)
218mm
(8.6in)
315mm
(12.4in)
7
L
R
H
Model R L H
Dimension of installation
hole
KSID012-H115Q-I
95mm
(3.7in)
170mm
(6.7in)
45mm
(1.8in)
Φ65mm(2.56in)
KSID216-H215Q-I
80mm
(3.1in)
100mm
(3.9in)
45mm
(1.8in)
Model R L H Dimension of installation hole
KSID022-H215Q-I
163mm
(6.4in)
293mm
(11.5in)
45mm
(1.8in)
Φ65mm(2.56in)
8
3.2 Outdoor Unit
More than 60cm(23.6in)
More than 70cm(27.6in)
More than 30cm(11.8in)
More than 60cm(23.6in)
(Service space)
Fence or
obstacles
More than 30cm(11.8in)
Note: The above drawing is only for reference. The appearance of your units may be different.
Model W D H W1 A B
KSID012-H115Q-O
660mm
(26.0in)
265mm
(10.4in)
540mm
(21.3in)
732mm
(28.8in)
458mm
(18.0in)
276mm
(10.9in)
KSID016-H215Q-O
760mm
(29.9in)
285mm
(11.2in)
590mm
(23.2in)
823mm
(32.4in)
530mm
(20.9in)
290mm
(11.4in)
KSID022-H215Q-O
845mm
(33.3in)
320mm
(12.6in)
700mm
(27.6in)
908mm
(35.7in)
560mm
(22.0in)
335mm
(13.2in)
9
4. Refrigerant Cycle Diagram
INDOOR OUTDOOR
LIQUID SIDE
GAS SIDE
HEAT
EXCHANGE
(EVAPORATOR)
HEAT
EXCHANGE
(CONDENSER)
COMPRESSOR
2-WAY VALVE
3-WAY VALVE
CHECK VALVE
(Heating Model only)
CAPILIARY TUBE
REVERSING VALVE
(Heating Model only)
COOLING
HEATING
ACCUMULATOR
10
5. Wiring Diagram
5.1 Indoor Unit
KSID012-H115Q-I
11
KSID216-H215Q-I
12
KSID022-H215Q-I
13
5.2 Outdoor Unit
KSID012-H115Q-O
14
KSID016-H215Q-O
15
KSID022-H215Q-O
16
6 Installation Details
6.1 Wrench torque sheet for
installation
Outside diameter Torque
Additional tightening
torque
Ф6.35mm 1/4in 1500N.cm(153kgf.cm) 1600N.cm(163kgf.cm)
Ф9.52mm 3/8in 2500N.cm(255kgf.cm) 2600N.cm(265kgf.cm)
Ф12.7mm 1/2in 3500N.cm(357kgf.cm) 3600N.cm(367kgf.cm)
Ф15.9mm 5/8in 4500N.cm(459kgf.cm) 4700N.cm(479kgf.cm)
Ф19mm 3/4in 6500N.cm(663kgf.cm) 6700N.cm(683kgf.cm)
6.2 Connecting the cables
The power cord should be selected according
to the following specifications sheet.
Appliance Amps AWG Wire Size
10 18
13 16
18 14
25 12
30 10
The cable size and the current of the fuse or
switch are determined by the maximum
current indicated on the nameplate which
located on the side panel of the unit. Please
refer to the nameplate before selecting the
cable, fuse and switch.
6.3 Installation for the first time
Air and moisture in the refrigerant system have
undesirable effects as below:
Pressure in the system rises.
Operating current rises.
Cooling or heating efficiency drops.
Moisture in the refrigerant circuit may
freeze and block capillary tubing.
Water may lead to corrosion of parts in the
refrigerant system.
Therefore, the indoor units and the pipes
between indoor and outdoor units must be leak
tested and evacuated to remove gas and
moisture from the system.
Gas leak check (Soap water method):
Apply soap water or a liquid neutral
detergent on the indoor unit connections or
outdoor unit connections by a soft brush to
check for leakage of the connecting points of
the piping. If bubbles come out, the pipes have
leakage.
1. Air purging with vacuum pump
1) Completely tighten the flare nuts of the
indoor and outdoor units, confirm that both
the 2-way and 3-way valves are set to the
closed position.
2) Connect the charge hose with the push pin
of handle lo to the 3-way valves gas service
port..
3) Connect the charge hose of handle hi
connection to the vacuum pump.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95

Klimaire KSID022-H115 -O / -I User manual

Category
Split-system air conditioners
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI