NuTone 695 is a powerful bathroom fan designed for rooms up to 85 square feet. With a 70 CFM airflow rating and a quiet operation at 6.0 Sones, it effectively removes moisture and odors from your bathroom. The fan features a plug-in motor, extra-large junction box, and a damper that opens and closes automatically. It can be installed in ceilings or walls and comes with torsion springs to adjust for thickness variances. NuTone 695 is suitable for use over tub or shower enclosures when installed in a GFI Branch Circuit.

NuTone 695 is a powerful bathroom fan designed for rooms up to 85 square feet. With a 70 CFM airflow rating and a quiet operation at 6.0 Sones, it effectively removes moisture and odors from your bathroom. The fan features a plug-in motor, extra-large junction box, and a damper that opens and closes automatically. It can be installed in ceilings or walls and comes with torsion springs to adjust for thickness variances. NuTone 695 is suitable for use over tub or shower enclosures when installed in a GFI Branch Circuit.

Architectural & Engineering Specifications
March 2004
Bathroom Fan
MODEL: 695
DESCRIPTION
• For baths up to 65 sq. ft., other rooms up to 85 sq. ft.
• Slotted mounting brackets for easy installation.
• Plug-in motor, extra large junction box.
• Damper opens when fan is turned on; shuts when
fan is off.
• Discharge is through 3" round duct through roof or wall.
• Attractive white polymeric grille with torsion springs
to adjust for thickness variances in ceiling or wall.
• Refer to NuTone's catalog for a complete listing of
accessories to effectively adapt this Bathroom Fan
to your construction requirements.
DESIGN FEATURES
Air Delivery: 70 CFM at 0.10" S.P.
Sound Level: 6.0 Sones.
Dimensions: Housing: 7
1
2
" long x 7
1
4
" wide x 3
5
8
"
high.
Grille: 9
1
2
" long x 8
11
16
" wide x
17
32
" thick.
Material & Finish: Housing: Galvanized steel.
Grille: White Polymeric.
Motor: Single coil, thermally protected,
115vAC, 60 Hz, 1.2 amp.
Blower Wheel: One-piece polypropylene,
4
3
4
" diameter.
Duct Size: 3" diameter.
ARCHITECT'S SPECIFICATIONS
Exhaust Fan shall be NuTone Model Number 695 as
manufactured by NuTone according to listed specifications.
Fan shall ventilate 70 CFM at 0.10" S.P. at a sound level of
6.0 Sones. Housing shall be 7
1
2
" x 7
1
4
" x 3
5
8
" and connect
to 3" duct.
INSTALLATION
• Not for use in kitchens.
• Suitable for use over tub or shower enclosure when
installed in a GFI Branch Circuit.
• Not for use with solid-state speed controls.
• Unit installs in ceiling or 2" x 4" wall construction. “A” unit
housing installed during rough-in stage of construction.
Power unit assembly and grille are installed when ceiling
or wall is finished.
• Unit mounts on 16" – 24" O.C. joists or studs. Housing
has collar for 3" round duct, and discharges vertically
or horizontally. Power unit snaps into housing for quick
assembly. Torsion springs on grille adjust for thickness
variances in ceiling or wall.
• Use a standard on-off toggle switch (purchase
separately).
• Installation Instructions are included with each unit.
CERTIFIED TEST DATA
HVI-2100 CERTIFIED RATINGS comply with new
testing technologies and procedures prescribed by the
Home Ventilating Institute, for off-the-shelf products, as
they are available to consumers. Product performance is
rated at 0.1 in. static pressure, based on tests conducted in
AMCA's state-of-the-art test laboratory. Sones are a
measure of humanly-perceived loudness, based on
laboratory measurements. This NuTone model is listed by
Underwriters' Laboratories Inc.
10 050
0
0.00
0.10
0.20
0.30
0.40
0.50
STATIC PRESSURE–INCHES OF WATER
50 Feet 40 Feet 30 Feet 20 Feet
10 Feet
CFM CUBIC FEET PER MINUTE
75 12525
AIR PERFORMANCE CURVE
(3 In. Duct to 10 Foot Lengths)
STATIC PRESSURE
INCHES OF WATER
CFM
0.05
74 71 68 66 63 60 56 49 43
0.1 0.15 0.2 0.25 0.3 0.35 0.4 0.45
The air delivery of a ventilating system may be
determined by:
1. Determine the equivalent duct length for each 90 degree
elbow by adding one foot of duct length for each inch of
duct diameter, i.e., a 4 inch diameter duct elbow equals
4 feet equivalent duct length and an 8 inch diameter
duct elbow equals 8 feet equivalent duct length.
2. Add the total straight length of duct and the equivalent
length for each elbow to obtain the total equivalent duct
length.
3. Locate the intersection of the fan performance curve and
the total equivalent duct length curves and draw a
vertical line down to the CFM scale and read the system
air performance.
(NOTE: 3
1
4
" x 10" duct equals 6 inch diameter duct.)
DIMENSIONS
7
1
4
"
3
5
8
"
7
1
2
"
8
11
16
"
9
1
2
"
Product specifications subject to change without notice.
NuTone, Inc., 4820 Red Bank Road, Cincinnati, Ohio 45227
Printed in U.S.A.
  • Page 1 1
  • Page 2 2

NuTone 695 User manual

Type
User manual
This manual is also suitable for

NuTone 695 is a powerful bathroom fan designed for rooms up to 85 square feet. With a 70 CFM airflow rating and a quiet operation at 6.0 Sones, it effectively removes moisture and odors from your bathroom. The fan features a plug-in motor, extra-large junction box, and a damper that opens and closes automatically. It can be installed in ceilings or walls and comes with torsion springs to adjust for thickness variances. NuTone 695 is suitable for use over tub or shower enclosures when installed in a GFI Branch Circuit.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI