Whirlpool WHD3090GW Dimensions Guide

Type
Dimensions Guide
Heat Pump Dryer
PRODUCT MODEL NUMBERS
W10858718B
11/2016
WHD3090G WHD5090G
DRYER DIMENSIONS
33
1
/2" Min.
(851 mm)
33
3
/4" Max.
(857 mm)
24"
(610 mm)
Front view:
24"
(610 mm)
33
1
2" Min.
(851 mm)
34
1
2" Max.
(876 mm)
Side view:
Back view:
7
1
/4 "
(184 mm)
4"
(102 mm)
3
/4"
(18 mm)
NOTES:
Allow clearance
behind dryer for
proper drain hose
routing and cooling
fan ventilation. Push
dryer back as far as
possible and make
sure drain hose
is not crushed
or kinked.
Water can be
drained into an
alternate location.
Remove the top
end of the white
hose from the water
tank and install,
for example, in
a floor standpipe
(see “Drain System”).
Grey
water
drain
Cooling
fan
IMPORTANT: Do not block cooling fan as your dryer may not
operate properly.
Power cord/
cable
41
1
/2"
(1054 mm)
24"
(610 mm)
3
/4"
(18 mm)
43
5
16"
(1100 mm)
26"
(654 mm)
White
hose from pump
to water tank
Installation spacing for recessed area
or closet installation
All dimensions show recommended and minimum spacing
allowed.
Additional spacing should be considered for ease of
installation and servicing.
Additional clearances might be required for wall, door,
floor, moldings, and drain system.
Additional spacing should be considered on all sides
of the dryer to reduce noise transfer.
For closet installation with a door, minimum ventilation
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilation openings are
acceptable.
Companion appliance spacing should also be considered.
Recommended installation clearances (dryer only):
Mobile home – Additional installation requirements:
This dryer is suitable for mobile home installations.
The installation must conform to the Manufactured
Home Construction and Safety Standard, Title 24 CFR,
Part 3280 (formerly the Federal Standard for Mobile
home construction and Safety, Title 24, HUD Part 280)
or Standard CAN/CSA-Z240 MH.
18" min.
(457 mm)
1"
(25 mm)
0" - 5"*
(0 mm - 127 mm)
24 in.
2
min.
(155 cm
2
)
48 in.
2
min.
(310 cm
2
)
3"
(76 mm)
3"
(76 mm)
1"
(25 mm)
*NOTE: 0"–5"
(0 mm–127 mm)
spacing is allowed
behind dryer, providing
drain hose is not kinked
or pinched.
Minimum diameter for a standpipe drain: 2" (51 mm). Top of
standpipe must be at least 30" (762 mm) high; install no higher
than 36" (910 mm) from bottom of dryer.
Floor standpipe drain system
Drain system can be installed by routing the white hose to
a floor drain, wall standpipe, floor standpipe, or laundry tub
instead of to the water tank. Select the method you need.
IMPORTANT: To avoid siphoning, only 4.5" (114 mm) of drain
hose should be inside standpipe; do not force excess hose
into standpipe. Always secure drain hose with a cable tie
(not supplied).
4.5"
(114 mm)
4.5"
(114 mm)
max. 48"
(1219 mm)
min. 30"
(762 mm)
Custom under-counter installation:
34
1
2" Min.
(876 mm)
1" Min.
(25 mm)
1" Min.
(25 mm)
max. 36"
(910 mm)
min. 30"
(762 mm)
0" Min.
(0 mm)
DRAIN SYSTEM
Because Whirlpool Corporation policy includes a continuous commitment to improve Dimensions are for planning purposes only. For complete details, see Installation
our products, we reserve the right to change materials and specications without notice. Instructions packed with product. Specications subject to change without notice.
To supply the required 3- or 4-wire, single-phase, 120-/240-volt, 60 Hz., AC-only electrical supply (or 3- or 4-wire, 120-/208-volt
electrical supply, if specied on the serial/rating plate) on a separate 30-amp circuit, fused on both sides of the line. A time-delay
fuse or circuit breaker is recommended. Connect to an individual branch circuit. Do not have a fuse in the neutral or grounding circuit.
Do not use an extension cord.
ELECTRICAL REQUIREMENTS
  • Page 1 1
  • Page 2 2

Whirlpool WHD3090GW Dimensions Guide

Type
Dimensions Guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI