Intermec MobileLAN access 2102 S Mounting & Installation

Category
Bridges & repeaters
Type
Mounting & Installation

This manual is also suitable for

Installation Instruc-
tions
MobileLAN™
access 2102
Mounting Kit for
EasyCoder Printers
Information in this manual is subject to change without prior notice and does not represent a commitment
on the part of Intermec Printer AB.
© Copyright Intermec Printer AB, 2002. All rights reserved. Published in Sweden.
EasyCoder and EasyLAN are registered trademarks of Intermec Technologies Corp. The word Intermec,
the Intermec logo, and MobileLAN are trademarks of Intermec Technologies Corp.
Torx is a registered trademark of Camcar Division onf Textron, Inc.
1
MobileLAN
access 2102 Mounting Kit for EasyCoder Printers – Installation Instructions
Chapter 1
Description
The MobileLAN
access 2102 Mounting Kit is an optional
device that makes it possible to fi t and connect an Intermec
MobileLAN
access 2102 device to any EasyCoder printer that
is already fi tted with an EasyLAN 10i or 100i interface board.
MobileLAN
access 2102
The kit consists of
one metal bracket for EasyLAN 10i-equipped printers
(EasyCoder 3240, 3400, 3440, 3600, 4420, and 4440)
one metal bracket for EasyLAN 100i-equipped printers
(EasyCoder F2, F4, 501 XP, and 601 XP)
one RJ-45 to RJ-45 communication cable
two screws
a Torx driver
this installation instruction booklet
The MobileLAN
access 2102 mounting bracket (plastic) is
packed with the MobileLAN
access 2102 device.
For instructions on how to con gure, connect, and use the
MobileLAN
access 2102 device, refer to the MobileLAN
access
21XX System Manual (P/N 067150) published by Intermec in
U.S.A.
Refer to the manuals that came with the EasyLAN 10i or 100i
interface board for information on how to install and use the
EasyLAN interface
.
Application of Use
Installation Kit
Manuals
MobileLAN
access 2102 Mounting Kit for EasyCoder Printers Installation Instructions
2
Chapter 2
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
O
I
Power
Network
T
est
EasyLAN 10i Interface Board
Remove the two Phillips screws that hold the cover plate of
the EasyLAN 10i interface board.
Fit the correct type of metal bracket (see illustration) to the
cover plate using the same screws.
Using the two #T10 Torx screws included in the kit, attach
the MobileLAN
access 2102 mounting bracket (plastic) to
the metal bracket.
Fitting the Brackets
#T10 Torx screws
(2 places)
Installation
Metal Bracket
EasyLAN 10i Board
MobileLAN
access 2102
Mounting Bracket
RJ-45 Connector
Phillips screws
(2 places)
The illustrations shows an EasyCoder
3400 printer. However, the same prin-
ciples apply to EasyCoder 3240, 3440,
3600, 4420, and 4440.
3
MobileLAN
access 2102 Mounting Kit for EasyCoder Printers Installation Instructions
Chapter 2 Installation
EasyLAN 100i Interface Board
Remove the two #T10 Torx screws that hold the cover plate
of the EasyLAN 100i interface board.
Fit the correct type of metal bracket (see illustration) to the
cover plate using the same screws.
Using the two #T10 Torx screws included in the kit, attach
the MobileLAN
access 2102 mounting bracket (plastic) to
the metal bracket.
Fitting the Brackets,
cont.
#T10 Torx screws
(4 places)
The illustrations shows an EasyCoder
F-series printer. However, the same
principles apply to EasyCoder XP-
series printers.
Metal Bracket
EasyLAN 100i Board
RJ-45 Connector
MobileLAN
access 2102
Mounting Bracket
MobileLAN
access 2102 Mounting Kit for EasyCoder Printers Installation Instructions
4
Chapter 2 Installation
Fit the slots on the back of the MobileLAN
access 2102
device over the hooks on the mounting bracket. Slide the
MobileLAN
access 2102 up slightly and the press the base
until it clicks into the clip at the bottom of the mounting
bracket.
Using the RJ-45/RJ-45 cable included in the kit, connect the
MobileLAN
access 2102 and the EasyLAN 10i or 100i inter-
face board installed in the printer.
Connect the MobileLAN
access 2102 to power using the
transformer/cable included in the kit.
Fitting the
MobileLAN
access
2102
Clip
Slots
Hooks
Mounting Bracket
MobileLAN
access 2102
MobileLAN
access 2102
RJ-45/RJ-45 Cable
Power to
MobileLAN
access
2102
5
MobileLAN
access 2102 Mounting Kit for EasyCoder Printers Installation Instructions
Chapter 3
Setting Up the Connection
General Description
The MobileLAN
access 2102 uses an IEEE 802.11B master/
slave connection.
The master is a MobileLAN
access 21XX connected to an Eth-
ernet network via a cable.
The slave is the MobileLAN
access 2102 tted on the printer
and connected to the printers EasyLAN 10i or 100i interface
board via a cable. The master and slave communicate via
radio.
Set up the master rst and then the slave using a Web browser
as described below.
Start a Web browser on a PC connected to a network:
Log in as intermec. Default password is intermec.
Master
It is important that you start by setting
up the Master and continue by setting
up the Slave!
MobileLAN
access 2102 Mounting Kit for EasyCoder Printers Installation Instructions
6
Chapter 3 Setting Up the Connection
Master, cont.
Set Node type to <Master>.
Set Wireless Hops to <Enabled>.
The Spanning Tree Settings/Global Flooding should now be
as follows:
7
MobileLAN
access 2102 Mounting Kit for EasyCoder Printers Installation Instructions
Chapter 3 Setting Up the Connection
Master, cont.
Select the Save/Discard Changes option.
Click on Save Changes and Reboot.
Note that this document only describes the steps necessary to
set up a wireless access point to connect with a printer. Other
parameters may need to be set in the access point to conform
to the network. Refer to the MobileLAN access 21XX System
Manual (P/N 067150) for further information.
MobileLAN
access 2102 Mounting Kit for EasyCoder Printers Installation Instructions
8
Chapter 3 Setting Up the Connection
Slave
Use a Web browser to set up the slave, that is, the
MobileLAN
access 2102 connected to your printer.
Log in as intermec. Default password is intermec.
Set the Node type to <Station>. Note that after changing
this parameter, the MobileLAN
access 2102 will not be able to
relay radio communications to other slaves.
9
MobileLAN
access 2102 Mounting Kit for EasyCoder Printers Installation Instructions
Chapter 3 Setting Up the Connection
Slave, cont.
Go to the Spanning Tree Settings and set the Secondary
LAN Bridge Priority to 1, Root priority to 0, and Second-
ary LAN Flooding to Enabled.
Also refer to the MobileLAN access 21XX System Manual (P/N
067150) for further information.
Master
Wireless Hops Enabled
Root Priority 0
Multicast Flood Mode Universal
Slave
Node type Station
Root Priority 0
Secondary LAN Bridge Priority 1
Secondary LAN Flooding Enabled
Setup Summary
MobileLAN
access 2102 Mounting Kit for EasyCoder Printers Installation Instructions
10
Notes
Intermec Printer AB
Idrottsvägen 10, P.O. Box 123
S-431 22 Mölndal, Sweden
tel +46 31 869500
fax +46 31 869595
www.intermec.com
*1-960547-02*
MobileLAN access 2102 Mounting Kit for EasyCoder Printers, Installation Instructions
*1-960547-02*
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14

Intermec MobileLAN access 2102 S Mounting & Installation

Category
Bridges & repeaters
Type
Mounting & Installation
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI