MrSteam CU SteamHead Installation & Operation Manual

Type
Installation & Operation Manual

MrSteam CU SteamHead is a device designed to be installed in steam rooms and provide steam for a comfortable and relaxing bathing experience. It features a durable construction with a heat-resistant finish, ensuring longevity and resistance to the high temperatures and humidity levels of a steam room environment.

The SteamHead's design allows for easy installation, with clear instructions provided in the manual. It can be mounted on walls made of tile, marble, or similar non-porous materials, and should be placed 12 inches above the floor and away from seating areas or traffic patterns. Proper sealing is crucial, and the manual emphasizes the use of Teflon or equivalent sealant on pipe threads and silicone sealant around the SteamHead's perimeter to prevent moisture penetration.

MrSteam CU SteamHead is a device designed to be installed in steam rooms and provide steam for a comfortable and relaxing bathing experience. It features a durable construction with a heat-resistant finish, ensuring longevity and resistance to the high temperatures and humidity levels of a steam room environment.

The SteamHead's design allows for easy installation, with clear instructions provided in the manual. It can be mounted on walls made of tile, marble, or similar non-porous materials, and should be placed 12 inches above the floor and away from seating areas or traffic patterns. Proper sealing is crucial, and the manual emphasizes the use of Teflon or equivalent sealant on pipe threads and silicone sealant around the SteamHead's perimeter to prevent moisture penetration.

CU Series Steambath Generators
__________________________________________________________
Steamhead Installation Instructions
PN 103984
mr.steam®steambaths
mr.steam®
www.mrsteam.com
43-20 34th Street
Long Island City, NY 11101
TEL: 800 76 STEAM
FAX: 718 472 3256
9410 S. La Cienega Blvd.
Inglewood CA 90301
TEL: 800 72 STEAM
FAX: 310 216 2944
Steam Head
(34” N.P.T.)
1
. For steam rooms constructed of tile, marble or similar non-porous
heat-resistant materials for the enclosure, locate steam head 12
inches above steam room floor and install Mr.Steam PN 103985
acrylic shield on each steamhead (provided).
IMPORTANT:
For Steam rooms using acrylic, fiberglass or other
non-heat resistant materials used for steam room enclosure, con-
sult the room manufacturer beofre installing the steamhead.
2.
Locate each steamhead away from bather seating area and away
from traffic patterns where incidental contact may occur.
3.
Install each steamhead with steam slots facing to the left and
right as shown in the diagrams.
4. NOTE:
To preserve the steamhead finish, do not use wrench or
other tools to tighten. Use of proper thread sealant and hand
tightening is usually sufficient.
5.
Apply a bead of silicone around the steamhead where it meets
the wall.
Acrylic Shield
Apply a small bead of silicone in the grooves on the top and bottom
of the steamhead. Place the provided Acrylic Shield (PN 103985) over
the steamhead until the tabs engage the grooves in the steamhead.
Steamheads get hot. Operation of the steam
room without an acrylic shield may expose users to the steamhead’s
hot surfaces. Do not operate steam room without an acrylic shield on
each steamhead.
IMPORTANT:
Do not use with water soluble fragrance or fra-
grance containing emulsifiers or aldehydes. Acrylic Shield dam-
age may result. Mr.Steam oils are approved for use with this
acrylic shield.
!WARNING
Fully Assembled
Assembly
Steam Head
Steam Pipe
Acrylic Sheild
Use Teflon or equal
sealant on pipe threads
Steam
Supply Pipe
Fill gap with silicone or
equal sealant as required
for moisture seal
Diagram A
Steam Head
3/4”
Finished interior face
of steam room wall
Diagram B
PUR 100427 REV 5/22
  • Page 1 1

MrSteam CU SteamHead Installation & Operation Manual

Type
Installation & Operation Manual

MrSteam CU SteamHead is a device designed to be installed in steam rooms and provide steam for a comfortable and relaxing bathing experience. It features a durable construction with a heat-resistant finish, ensuring longevity and resistance to the high temperatures and humidity levels of a steam room environment.

The SteamHead's design allows for easy installation, with clear instructions provided in the manual. It can be mounted on walls made of tile, marble, or similar non-porous materials, and should be placed 12 inches above the floor and away from seating areas or traffic patterns. Proper sealing is crucial, and the manual emphasizes the use of Teflon or equivalent sealant on pipe threads and silicone sealant around the SteamHead's perimeter to prevent moisture penetration.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI