49-3000279 Rev 0 9
USING THE DRYER
Administrator Mode
With Administrator Mode, the administrator can check the cycle parameters, adjust cycle parameters, and manage
coin pricing.
Enter Administrator Mode
There are two methods to enter Administrator Mode:
Method 1: Button matrix on control panel (with PIN)
Press and hold High, No Heat and Start/Pause buttons at the same time for 10 seconds. On the display, “0000” is
shown and a PIN is required to enter Administrator Mode. The LED indicators will blink to indicate the buttons that
are used to edit content on the display. In this mode, the control will accept entry of a 4-digit PIN code (as described
below) providing access to Administrator Mode (default PIN code 1234).
How to input PIN
Each press of the No Heat button will increment the units PIN code digit from “0” to “9” and repeating, without
incrementing the tens digit. The Low button will increment the tens digit from “0” to ”9” and repeating, without
incrementing the hundreds digit. The Medium button will increment the hundreds digit from “0” to ”9” and repeating,
without incrementing the thousands digit. The High button will increment the thousands digit from “0” to ”9”. Once
4-digit number is ready, press Start/Pause button to confirm, if the 4 digit PIN is correct it will enter the "register
navigation mode” and “Ad” will flash on the screen. Otherwise, it will beep twice and wait for correct PIN.
Method 2: Press the Reset button on UI board (without PIN)
Single press of the reset button on the board would enter Administrator Mode, this will not require a pin. To access the
reset button, refer to the Reset Button section at the end of Administrator Mode section.
View and Edit Administrator Mode Parameters
When Administrator Mode is activated “Ad” will flash in the display and then “000” will be displayed as the first
accessible register. Press Low or No Heat buttons to navigate forward or backward thorough the registers.
NOTE: LEDs above pushbuttons will blink when a button is available for activating a function or changing a value.
How to Navigate Parameter Registers:
The Low (step down) and No Heat (step up) buttons will be used to navigate the different register addresses.
Pressing and holding either of these buttons will result in an increasingly faster decrement or increment of the register
address (without beep for repeated steps). The register address will cycle from highest register back to “000” when
the limits have been reached. Register numbers that are not assigned a function in this specification will be skipped
over when navigating.
How to View and Edit a Parameter:
When a register address is selected, press Start/Pause button to view a particular register’s contents, to save
the new value, and return to "register navigation mode". For registers whose contents are editable, the LEDs
corresponding to the buttons that can be used to edit the content will flash. The No Heat, Low, Medium, and High
buttons will increment the one’s, ten’s, hundred’s, and thousand’s digits of the display, respectively. For binary values,
the button corresponding to the display digit where the value is shown will toggle the value 0 / 1 / 0 / 1. All changes
made to editable registers can be saved by pressing the Start/Pause button to return to “register navigation mode”.
If the register value is “read only” no LEDs will be blinking and control will make a chime sound when an attempt is
made to change the value.
Exit Administrator Mode
There are 3 methods to exit Administrator Mode:
Method 1: Pressing the Reset button again will allow you to exit the Administrator Mode.
Method 2: Press and hold High and No heat and Start/Pause button for 10 seconds during the parameter selection
mode will exit the Administrator Mode and enter standby mode.
Method 3: When no OUTPUTS are active (machine is in standby mode), and there is no control pushbutton pressed
for 15 minutes, Administrator Mode will automatically terminate, and the control system will return to standby mode.