(105) MODEL 637R FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 04/22/2015
105
SAVE THESE INSTRUCTIONS
English
Page 8
TROUBLESHOOTING GUIDE
• Filtercordmustbepluggedintoa3
wire outlet that is protected by a Class
AGroundFaultCircuitInterrupter.
• Resetcircuitbreaker.Ifcircuitbreaker
trips repeatedly, your electrical system
may have a defect. Turn off circuit
breaker and call an electrician to
correct the problem.
• Letmotorcooldown.
• AdjustthechlorineandpHlevel.Consult
your local swimming pool supply stores.
• Cleanorreplacecartridge.
• Checkthecartridgeforholes.Replaceif
damaged.
• Operatethefilterforlongerperiods.
• Cleanthestrainerscreenattheinlet.
• Clearanyobstructionsintheintake
hose by discharging it inside pool wall.
• Tightenhoseclamps,checkhosesfor
damage, check pool water level.
• Replacecartridge.
• Cleancartridgemoreoften.
• Installthenozzleattheupperposition
of the pool inlet, and the strainer at the
lower position of the pool outlet.
• Fillpooltocorrectwaterlevel.
• Cleanstrainerscreensatpoolinlet.
• Tightenhoseclamps,checkhosefordamage.
• Clearanysticksorleavesinthe intakehose.
• Openthereleasevalveattopofpump.
• Removecover&checkforO-ring.
• Tightencoverorvalve(Manually).
• Tightenorreinstallhoseclamps.
• Puttheo-ringbackintothegroove.
• Replaceanewhose.
• Openairreleasevalve,liftandlower
the inlet hose until water starts to flow
out of air release valve, close air release valve.
FILTER MOTOR
FAILS TO START
FILTER DOESN’T
CLEAN POOL
FILTER DOESN’T
PUMP WATER OR
FLOW IS VERY
SLOW
PUMP DOESN’T
WORK
TOP COVER
LEAKING
HOSELEAKING
AIRLOCK
• Themotorisnotpluggedin.
• TheGFCIcircuitbreaker
is tripped.
• Motortoohotandoverload
protection shut motor off.
• ImproperchlorineorpHlevels.
• Filtercartridgeisdirty.
• Damagedcartridge.
• Excessivelydirtypool.
• Thestrainerscreenis
restricting the water flow.
• Cloggedinletordischarge.
• Anairleakontheintakeline.
• Scaleorbuilduponcartridge.
• Excessivelydirtypool.
• Dirtyfiltercartridge.
• Thenozzleandstrainer
connection are reversed.
• Lowwaterlevel.
• Strainerscreenpluggedup.
• Anairleakontheintakehose.
• Faultymotorortheimpeller
is jammed.
• Anairlockinsidethecartridge
chamber.
• O-ringmissing.
• Coverorairreleasevalvearenot
tight.
• Hoseclampsarenotwell-fitted.
• Hoseo-ringdislodgedwhen
connecting the hose.
• Hosebroken.
• There’sairtrappedinthe
pump housing and inlet hose.
TROUBLE