LG Electronics LW6013ER User manual

Type
User manual
OWNER’S MANUAL
AIR CONDITIONER
Please read this manual carefully before operating
your air conditioner and retain it for future reference.
P/NO MFL67653901
www.lgappliances.com
TYPE WINDOW
MODEL LW6013ER
LW6012ER
Before Operation
7
16
19
Safety Precautions
Introduction
Electrical Safety
Installation
Operating Instructions
Maintenance and Service
Do not store flammables like
gasoline benzene thinner
etc. near the air conditioner.
No correlation between fan
usage and oxygen depletion.
Unplug the unit when not
using it for a long time.
For inner cleaning, contact an Authorized Service Center or a dealer.
Do not use harsh detergent that causes corrosion or damage on the unit.
Harsh detergent may also cause failure of prod
uct, fire, or electric shock.
Hold the plug by the head
it out.
not the cable when taking
Never touch the metal parts
of the unit when removing
the filter.
Install the product so the exhaust and noise
are not aimed directly at the neighbors.
When gas leaks, open the
window for ventilation before
operating the unit.
Be considerate.
Follow installation instructions exactly.
y
If you eat the liquid from the battery,brush
your teeth and see doctor.Do not use the
remote if the battery has leaked.
y
Do not use this appliance for
special purposes such as
cooling pets
foods
precision
machinery or objects of art
You will feel better.
Instead of running air conditioning
constantly
open a window
for fresh air occasionally.
You will feel better.
If the liquid from the battery gets onto your skin
or clothers
wash it well with clean water. Do
not use the remote if the battery has leaked.
2. No correlation between fan usage and oxygen depletion.
3.
RESET
TEST
9
should be
Avoid shock hazard. This unit cannot
be user-serviced. Do NOT open the
tamper-resistant sealed portion.
All warranties and performance will
be voided. This unit is not intended
to be used as an ON/OFF switch.
10
Left Guide Panel
Right Guide Panel
Curtain
Phillips head
screwdriver
Scissors or
knife
11
12
Clearance
(Type D)
drawing
in the drawing.
upper and bottom guide.
with 4 screws (Type A) on each side.
(Type D)
13
Bottom Guide
Left Guide panel
Right Guide
panel
(Type A)
Screws
Curtain
1-1. Set the air conditioner in the window
so that is centered. Place the air
conditioner so that front edge of the
bottom guide is against the back
edge of the sill.
(Type G)
4
(Type B) to secure them.
1-2. Bring the window down so that the
front edge of the upper guide is in
front of the window. Make sure that
air conditioner is level or tilting
slightly to the outside.
CAUTION
To prevent broken glass or
damage to windows, on vinyl or
other similarly constructed
windows, attach the window
locking bracket to the window
side jamb with one Type A screw.
Bracket
Bottom Guide
14
15
3-4
3-3.
Remove the screw from the right
side of cabinet.
(Type H)
16
POWER
Operation starts when this button is pressed and stops when you
press the button again.
- when the air conditioner is off,it can be set to automatically turn
Delay OFF
- when the air conditioner is on,it can be set to automatically turn
on from 1 to 12 hours at its previous mode and fan settings.
off from 1 to 12 hours.
Delay ON
ON/OFF TIMER
FAN SPEED SELECTOR
Use to set the fan speed to
Low (F1), MED (F2), High (F3).
OPERATION MODE SELECTOR
the desired fan speed.
Everytime you push this button it will toggle between Cool Fan, and Dry.
Cool - Compressor runs and cools the room. Use the
and FAN buttons to
set the desied temperature and circulation fan speed.
Fan - Fan circulates air but compressor does not run. Use the FAN button to set
17
During operation in failure of electric power, the unit runs as previous setting operation.
y
Do not use rechargeable batteries. Make sure that the batteries are new.
Do not mix alkaline, standard (Carbon-zinc) or rechargeable (Nickel-cadmium)
batteries.
- In order to prevent discharge, remove the batteries from the remote control if
the air conditioner is not going to be used for an extended period of time.
To maintain optimal operation of the remote control, the remote sensor should
not be exposed to direct sunlight.
Keep the remote control away from extremely hot or humid places.
1. Push out the cover on the back of the remote control with your thumb.
2. Pay attention to polarity and insert two new AAA 1.5V batteries.
3. Reattach the cover.
Once the set temperature is reached the compressor and circulation fan turns off.
Dry
- Dry mode is used to remove humidity from the room without additional cooling.
Fan speed is pre-set and cannot be adjusted.
TEMPERATURE CONTROL
The thermostat monitors room temperature to maintain the desired temperature.
The thermostat can be set between 60
F~86 F (16 C~30 C).
The fan stops when the compressor stops cooling.
Approximately every 3 minutes the fan will turn on and check the room air
temperature if cooling is needed.
Energy Saver
drain
base pan
base pan
18
Inlet Grille
19
1. Pull the inlet grille forward.
2. Remove the air filter from the front grille by pulling the air filter up slightly.
3. Wash the filter using lukewarm water below 40
4.Gently shake the excess water from the filter and replace.
18
an outlet of the proper
voltage and amperage.
call 1-800-243-0000.
20
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44

LG Electronics LW6013ER User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI

in other languages